Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 00 VIDYUT NAGAR MEERANPUR SADDARALI TANDA AMBEDKAR NAGAR UTTAR PRADESH 224238 | AMBEDKAR NAGAR | UTTAR PRADESH | 224238 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.2 L
EMD Value
₹10,500
Closing Date
27 Dec 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
OFFICE OF THE SE OMCIV BTPS PTPP PARICHHA
Routine and Electrical Breakdown Maintenance of various capacities of 6.6 KV motors Ranging from 340 KW to 3600 KW and 0.4 KV LT motors of Unit 3and4 of PTPP Parichha Jhansi
2021_RVUNL_654070_1
T-07/EMD-I/BTPS/PTPP/21-22
Open Tender
Electrical Works
Lump-sum
365 days
PTPP Parichha Jhansi
As per Tender
2 documents required · 2 mandatory
₹590
DY CAO PTPP PARICHHA
₹10,500
29 Dec 2021
10 Dec 2021
28 Dec 2021
10 Dec 2021
27 Dec 2021
10 Dec 2021
120 days
Amount
ROUTINE MAINTENANCE WORK OF 6.6 KV MOTORS OF 2X210 MW PTPP PARICHHA
Routine Maintenance of various capacities of 6.6 KV motors Ranging from 340 KW to 3600 KW of Unit # 3&4 PTPP Parichha Jhansi” as per scope of work Sl. No. 1 to 8
ELECTRICAL BREAKDOWN MAINTENANCE OF VARIOUS CAPACITIES OF 6.6 KV MOTORS (RANGING FROM 340 KW TO 3600 KW) Category – A: - 6.6 KV mill, FD, CEP, ACW, TAC motors and Category – B:- 6.6 KV PA, ID, CW, BFP motors.
Proper tightening of stator copper leads, Tail cables, brass connectors and main cables etc inside cable connection box of motor at motor end as per scope of works Sl. No. 1 to 6 for Category A motor
Proper tightening of cable connections at breaker end as per scope of works Sl. No. 1 to 6 for Category A motor.
Disconnection and re-connection of 6.6 KV cable connections at motor end as per scope of works Sl. No. 1 to 6 for Category A motor.
Disconnection and re-connection of 6.6 KV cable at breaker end as per scope of works Sl. No. 1 to 7 for Category A motor.
Measuring of 6.6 KV motor & cable insulation resistance (IR) value by 2.5/5 KV megger as per instruction of concerned AE/JE. Measuring IR value of motor for 1min and 10min time for measuring polarization index of motor to ascertain the healthiness of motor as per scope of works Sl. No. 1 to 10 for Category A motor.
Repairing of stator copper cable end of 6.6 KV Motor as per scope of work Sl. No. 1 to 8 for Category A motor.
Replacement of Brass terminal connector/tail copper cable/FRP moulding joint box/nylon gland part as per scope of work Sl. No. 1 to7 for Category A motor.
Proper tightening of stator copper leads, Tail cables, brass connectors and main cables etc inside cable connection box of motor at motor end as per scope of works Sl. No. 1to 6 For category B motor.
Proper tightening of cable connections at breaker end as per scope of works Sl. No. 1 to 6 For category B motor.
Disconnection and re-connection of 6.6 KV cable connections at motor end as per scope of works Sl. No. 1 to 6 For category B motor.
Disconnection and re-connection of 6.6 KV cable at breaker end as per scope of works Sl. No. 1 to 7 For category B motor.
Measuring of 6.6 KV motor & cable insulation resistance (IR) value by 2.5/5 KV megger as per instruction of concerned AE/JE. Measuring IR value of motor for 1min and 10min time for measuring polarization index of motor to ascertain the healthiness of motor as per scope of works Sl. No. 1 to 10 For category B motor.
Repairing of stator copper cable end of 6.6 KV Motor as per scope of work Sl. No. 1 to 8 for Category B motor.
Replacement of Brass terminal connector/tail copper cable/FRP moulding joint box/nylon gland part as per scope of work Sl. No. 1 to7 for Category B motor.
Replacement of C.T. of Neutral side as per scope of work Sl. No. 1 to 5 for Category B motor.
Removal & installation of neutral side CT connection box as per scope of work Sl. No. 1 to 9 for Category B motor.
BREAKDOWN MAINTENANCE OF 0.4 KV(LT) MOTORS
Removal of 3 Phase , 700 RPM, 240 Watt LT motor from its foundation and installation after completion of work
Removal of 3 Phase , 900 RPM, 500 Watt LT motor from its foundation and installation after completion of work
Removal of 3 Phase , 0.37 KW to 1.0 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 1.1 KW to 1.5 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 2.2 KW to 3.75 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 7.5 KW LT motor from its foundation and installation after completion of work
Removal and installation of 3 Phase , 0.37 KW to 1.0 KW LT motor fan/coupling/ bearing from /on rotor shaft.
Removal and installation of 3 Phase, 1.1 KW to 1.5 KW LT motor fan/coupling/ bearing from /on rotor shaft
Removal and installation of 3 Phase, 2.2 KW to 3.75 KW LT motor fan/coupling/ bearing from /on rotor shaft
Removal and installation of 3 Phase, 7.5 KW LT motor fan/coupling/ bearing from /on rotor shaft
O/H of 3 Phase , 700 RPM, 240 Watt LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase , 900 RPM, 500 Watt LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 0.37 KW to 1.0 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 1.1 KW to 1.5 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 2.2 KW to 3.75 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 7.5 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
Rewinding of 3 Phase , 700 RPM, 240 Watt LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase , 900 RPM, 500 Watt LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 0.37 KW to 1.0 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 1.1 KW to 1.5 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 2.2 KW to 3.75 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 7.5 KW LT motor with new copper wire exactly similar to original winding
Repairing of 3 Phase , 700 RPM, 240 Watt DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase , 900 RPM, 500 Watt DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 0.37 KW to 1.0 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 1.1 KW to 1.5 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 2.2 KW to 3.75 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 7.5 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Providing new shaft for 3 Phase , 700 RPM, 240 Watt motors
Providing new shaft for 3 Phase , 900 RPM, 500 Watt motors
Providing new shaft for 3 Phase, 0.37 KW to 1.0 KW motors
Providing new shaft for 3 Phase, 1.1 KW to 1.5 KW motors
Providing new shaft for 3 Phase, 2.2 KW to 3.75 KW motors
Providing new shaft for 3 Phase, 7.5 KW motors
Re-metalizing and machining of rotor shaft to get its original shape & size. (0.37 KW to 7.5 KW motors).
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (up to 1 KW motor)
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (1 KW to 5 KW motor)
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (5 KW to 10 KW motor)
Replacement of gasket of 6.6 KV motor’s CT box & cable connection box at motor end
Overhauling of bearing vapour exhauster fan & motor as per scope of work
Replacement of cooler grass and water pipes by new one of ID fan motor external cooler
M/S Vikas Electricals
M/S NOSAD CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .