Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹9.5 L+₹1.1 L (13.0%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹9.5 L+₹1.1 L (13.2%)Rejected-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹9.5 L+₹1.1 L (13.2%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹9.5 L+₹1.1 L (13.5%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹26,280
Closing Date
12 Nov 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
MANNING AND OPERATION OF SEWAGE TREATMENT PLANT AT CARRIAPPA VIHAR INCLUDING REPAIR WORK IN THE AREA OF AGE U W S II UNDER GE U WATER SUPPLY DELHI CANTT 10
2020_MES_389077_1
GE/WS/D-117 of 2020-21
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹26,280
Yes
5 Dec 2020
22 Oct 2020
16 Nov 2020
22 Oct 2020
12 Nov 2020
5 Nov 2020
Amount
PART-I OPERATION AND MAINTENANCE OF E/M INSTALLATIONS
Operation and Maintenance of sewage Treatment plant at Carriappa vihar STP of capacity 600 KLD by deploying experienced qualified one skilled operator/staff, round the clock including Sunday and holidays in three shifts per day of 08 hours each ( Ist shift from 0600 to 1400 hours,IInd shift from 1400 to 2200 hours and IIIrd shift from 2200 to 0600 hours) complete inclusive of daily, weekly , monthly, quarterly, Half yearly & Yearly maintenance of equipments. scope of work as described in notes given below complete all as specified and as directed .
Rates required to be quoted for executing the work as describrd in Srl.No. 2 here-in-before:-
Worker's wage per person as per existing rules
Employees Provident Fund as mentioned in the tender documents
Employees State Insurance Contribution as mentioned in the tender documents
Contribution of Bonus as mentioned in the tender documents
Over head & profit on srl No 3.01 to 3.04
LWC as mentioned in the tender documents
Notes for Srl No. 2 :- The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount to the workmen, ie proof of payment
Scope of Work for srl no. 2 comprises:- (i) Stacking the sludge cakes properly (ii) Cleaning the blockages in any pump/pipe line (iii) Supplying/distributing the treated water regularly as per the directions. (iv) Complete cleaning of grits and channels daily. (v) Brooms and cleaning materials will be arranged by the contractor (vi) During the cleaning safety equipments will be supplied/arranged by the contractor.
(vii) POL will be collected from MES store yard under Sch B free for use ,by the contractor at his own arrangements.For record purposes PRRB shall be maintained. (viii) Removing the algae/ sludge in the tube settler and keeping the surrounding area clean daily and removing vegetations etc failing which recovery of Rs. 200/- per day shall be made. (ix) Mixing of the chemicals as directed .
Notes for srl No 2 :- EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set
Notes for srl No 2 :- Maintaining the following records :- (i) Record of chemical consumption. (ii) Record of treated water and electricity consumption (log sheet) (iii) Record of DG set daily running (log sheet) (iv) Record of water meter reading
Notes for srl No 2:- (i) The Plant shall be run by the skilled operator minimum qualification ITI/ matric with minimum three year experience. Non submission of police verification with ID proof of operator(s), a panel recovery of Rs. 1000/- per person per month shall be made.
(ii) (a) Working hours of a particular team of workers shall not exceed 08 hrs per day and no workmen shall be allowed to work beyond 08 hrs per day. (b) In case the contractor fails to deploy requisite numbers of workmen, the operator / workmen against defficiency shall be deployed at risk and cost of the contractor through SPOT QUOTATION and no payment shall be made to the contractor for the shift involved. (c) In addition to above a recovery of Rs. 500 per shift per workman shall be made from contractor's dues as and when becomes due. (d) Duty roster of manpower deployed shall be displayed otherwise recovery of Rs 500/- per installation per day shall be made.
(iii) All the provisions of contract labour Act 1970 shall be strictly adhered to. (iv) For payment of minimum wages to the workers provisions of particular specifications shall be strictly adhered to. (v) Log sheet for records shall be supplied by the contractor after approval of format by GE/Engineer-in-charge.
(vii) Chemicals, Diesel and engine oil for DG set shall be issued under Sch 'B' as free for Use .
(viii) Contractor shall ensure that treated sewage water shall confirm to the following characteristics:- (i) TSS : < 10 mg/litre (ii) BOD : < 10 mg/litre (iii) COD : < 150 Mg/litre (iv) ph : 6.5 - 8.5 (v) Total Coliform : < 100 MPN/100 ml (desired nil) (vi) Residual CI < 1 mg/litre
Notes for srl No 2 :- (A) The rate quoted by the contractor shall also deemed to be included for all the aspects mentioned here-in-after. (B) (i) The tenderer shall upload and submit original copy of MOU executed / made with OEM such as M/s Hydrotech paryavaran India Pvt Ltd or M/s ION Exchange or M/s Fontus or M/s Thermax or M/s SIMA Labs Pvt Ltd or any other E-in-C’s approved firm in the office of GE(U) water supply, Delhi Cantt-10 before the scheduled bid opening date. (ii) The MOU shall be executed / made as per specimen MOU given at srl No 15 here-in-after. (iii) Please note that in absense of MOU executed as per specimen MOU, price bid will not be opened.
Specimen of MOU (For srl No 2) We, M/s [Name of the OEM] do hereby undertake the followings:- (i) STP will be operated and maintained under guidance & supervision of our experts and it will be ensured that plant is run by skilled workmen. (ii) We will inspect the plant monthly and submit the report for the efficient functioning of the plant. (iii) We will ensure that the test result of the treated water comply with the paramenters given in the contract agreement. (iv) We will provide commited technical support in the advert of any requirement of the same and proper operator training will be provided in order to run the plant effectively. (v) We will provide the details/ estimates of the chemicals required for the sewage treatment plant. Note :- (a) Inspection report of OEM shall be enclosed with each payment details, failing which no payment shall be made to the contractor. (b) The contractor's rates shall be deemed to be included for above aspect. Nothing extra shall be paid on this account.
PART-II REPAIR OF STP UNDER AGE (U) W/S-II
Carrying samples for Testing of treated water of STP ,submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE. Details are as under :- (a) Carrying out minimum essential testing of water as per IS 10500 of 1991 mandatory for chemicals, colour, odour, PH value, TSS, BOD, COD, Total residual chlorine, total Nitrogen, Sulphate, oil and grease , Ammonical Nitrogen (NH3-N) and Bacteriological total coliform organisms per 100 ml (MPN) and E colliie in 100 ml. Note:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
Testing of Sewage water as per relevant IS of STP , submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE Details are as under :- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Note:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
Periodical Cleaning of Sewage and removing of settled down Sewage sludge cum mud/De-Silting etc STP for Equalization tank of capacity upto 270 CUM complete all as specified and as directed. Note:- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
Periodical Cleaning of Sewage well and removing of settled down Sewage sludge cum mud/De-Silting etc of Sewage Well of size 7.5 mtr deep x 5 mtr dia complete all as specified and as directed.
Notes for srl item Nos 20 :- Rate quoted shall include the aspects:- (i) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes . (ii) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB . (iii) Sewage Sludge disposable tractor/truck with driver and POL required for the same (duly covered with necessary tarpaline ) and disposing the same to the location where approved by the Delhi Canttonment Board/PCB
(iv) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the Delhi Canttonment Board/PCB. (v) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank as directed. (vi) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site as directed.
Material and labour for cleaning of treated water tank of storage capacity 300000 ltrs, filter feed tank of capacity 69 Cum, chlorine contract tank of capacity 17 Cum thoroughly by removing mud, grits etc from STP complete all as specified and as directed.. Loc:-Carriappa Vihar Note:- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
Material and Labour for cleaning of MBBR-1 and MBBR-2 tank and taking out complete FAB PVC media from the tank and re-filling the same after washing/cleaning throughly of STP by removing mud, grits etc from the tank complete all as required at site and directed.
M&L for preparation of Old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying two coats of cement base paint including necessary scaffolding work etc. complete all as specified and directed.
M&L for preparation of Old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying one coat of distemper oil emulsion including necessary scaffolding work etc. complete all as specified and directed.
Material and labour for painting on steel and iron surfaces with one coat of synthetic enamel paint as per existing colour scheme or pattern after preperation of old painted surface of any description over 10cm in width or girth complete all as specified and directed.
Taking down existing LED street light fitting, model SLE UL, 90 Watts IP 66 LXN for servicing, calliberation and repair of CC LED driver (PCB) with input voltage 240 V AC 50 Hz and output voltage 21-36 V DC, 2.30 amp and refixing in position by providing LED 90 watts to make it fully functional complete all as specified and as directed.
Supply and fixing in repair 20W surface and wall mounted LED batten light fitting, extruded aluminium housing provided complete all as specified and directed.
Supply & fixing in replacement heat resistance , weather proof agro shed net for covering of tanks complete with fixing arrangement around the tank complete all as specified and directed.
Supply and fixing Switch piano,flush type,single pole one way for 5 amps including taking down existing Unsv switch piano complete all as specified and as directed.
Supply and fixing Switch piano,flush type,single pole one way for 15 amps including taking down existing Unsv switch piano complete all as specified and as directed.
Supply & fixing socket outlet 2 in 1, 3/5 pin of rating 5/15 Amp including taking down existing Unsv switch socket outlet complete all as specified and as directed.
PART-III SCH OF CREDIT TO BE QUOTED BY CONTRACTOR
Old UNSV LED Driver Streer light fitting
Old UNSV Batten light fitting
Old UNSV weather proof agro shed net
Old UNSV switch piano 5 amp
Old UNSV switch piano 15 amp
Old UNSV 5/15 amp socket
Notes for srl No. 35 to 40 :- Rate quoted in column 6 shall not be less than the estimated cost inserted by MES under column 5. In case bidder quotes rates less than the corresponding rate under column 5, the rate quoted shall be amended as per column 5 and total amount shall be amended accordingly.
SM CONSTRUCTION COMPANY
Rahul Enterprises
Microsys Controls India
HIND CONSTRUCTIONS
ONKAR ENGINEERS CONTRACTORS
AMIT ASSOCIATES
DHAIRYAE ENTERPRISES
V S BUILDER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .