EXECUTIVE ENGINEER (SDW)-II
S.T.P. OKHLA MATHURA ROAD NEW DELHI-110025
Electrification with other allied works at newly constructed building at Laboratory of STP Okhla.
2021_DJB_211662_4
NIT No-13 EE (SDW) II/ (21-22)
Open Tender
Electrical Works
Works
20 days
S.T.P. OKHLA MATHURA ROAD NEW DELHI-110025
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
Yes
6 Dec 2021
26 Nov 2021
2 Dec 2021
26 Nov 2021
2 Dec 2021
26 Nov 2021
1.10.0 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. ( DSR-2018) 1.10.3 Group C.
1.14 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018) 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1.25 S/F Two module Stepped type Electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. (DSR 2018)
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR - 2018)
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(DSR-2018)
1.34 S&F of brass batten/angle holder i/c connection etc. as reqd.
1.33 S/F 3 pin 5 amps ceiling rose on existing switch box/wooden box i/c connection etc as reqd
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as reqd
1.5 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as reqd. 1.50.1 up to 450mm sweep
2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (DSR-2018) 2.5.2 8 way (4 + 24), Double door
2.10.0 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCBDB complete with connections, testing and commissioning etc as reqd. DSR-2018 2.10.2 Single pole and neutral
2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required..DSR-2018 2.2.1 100 A, 16KA TPMCCB
2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc as reqd
Market Rate Supplying, Installation, Testing and Commissioning of 4 feet nominal size LED having extruded aluminum housing, colour temperature 6500K having wattage 18-24 Watt and Lumen output not less than 2000 Lumens directly on ceiling/wall i/c connection with 1.5 sq mm FRLS PVC insulated copper conductor , Single Core Cable and earthing etc as reqd.
Market Rate Supply of 380 mm sweep, 900 rpm heavy duty exhaust fan operation on 230V, 50 Hz AC single phase supply etc. as reqd.
Market Rate Supplying, Installation, testing and commissioning of energy efficient surface/recess mounted type 34W to 38W PMMA diffuser LED panel luminaries of size 2ft x 2 ft (nominal size with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system colour temperature 5500K to 6500K, CRI (Ra)>70-75, operating voltage 100-300 volts with Class-I protection.
Market Rate Supply of 1200mm white ceiling fan complete with capacitor, double ball bearing standard size of down rod, canopies, three nos. Suitable for operation on single phase 220-240Volt AC 50 HZ, (Without regulator)
Market Rate Individual/ LED surface Track light wall Mounting with high lumen efficacy, Beam angle 38 degree, 20W. Cool White/ Neutral white/ Warm white as per instructions of engineer-in-charge. Make of above material/items:- North-West/Havells/Crompton or its equivalent and after approval of the engineer-in-charge.
ISHIKA ASSOCIATES
ztp corporation
Volts And Watts Electronics Pvt. ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .