Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.1 L+₹1.2 L (3.49%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.5 L+₹1.6 L (4.55%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹36.8 L+₹1.9 L (5.50%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹37.0 L+₹2.1 L (5.91%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER GOMANTAK
GARRISON ENGINEER GOMANTAK PIN 403802
Repairs Replacement Cleaning of Wornout Sewage Line Manhole including cleaning of Septic Tanks at Zone A and Zone B under AGE BR II in GE Gomantak Vasco
2023_MES_595310_1
8532/E8
Open Tender
Support/Maintenance Service
Item Rate
330 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹70,000
Yes
7 Aug 2023
13 May 2023
6 Jun 2023
13 May 2023
5 Jun 2023
25 May 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10 sqm on plan and getting out in hard/dense soil.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10 sqm on plan and getting out in soft/disintegrated rock.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Cleaning of sewage line of any diameter and of any description including manholes by manually or other means, to clear the sludge/blockage inside the sewage line and manholes and will be flushing with water to drain out sludge etc. inside the sewage line from manhole to ease the flow of sewage including removing the sludge and re- fixing the manhole cover complete all as specified and as directed. (Note : The lines measured once cannot measured again within 2 months. If blocks in the same lines re-occur within 2 months the contractor will be paid extra for this).
Demolition/breaking of drain pipes laid in trenches in foul condition of 150mm dia.
M&L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
Supply and fixing in repairs PVC (SWR) pipes 160 mm dia type 'A' single socketed in any length with rubber ring joints laid in trenches or in floors
M&L concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150/160 mm dia bore of pipe in cement concrete 1:3:6 type C-2 all as specified and directed
Demolition/breaking of drain pipes laid in trenches in foul condition of 300mm dia.
M&L for 300mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 300 mm dia bore of pipe in cement concrete 1:3:6 type C-2 all as specified and directed
Dismantling of cast iron drain pipe 100mm/75mm dia jointed in cement mortar and taking out of trenches/wall/floor etc incl fitting in foul condition.
Supply and fixing in repairs PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls in foul condition
Supply and fixing in repairs PVC (SWR) pipes 75 mm single socketed in any length with rubber ring joints fixed to walls in foul condition incl dismantling of old pipe.
Demolition of stone/brick masonry wall built in cement mortar
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level)
M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate
M & L for precast cement concrete block masonry with solid blocks in cement concrete 1:3:6, type C1 using 20 mm graded crushed stone aggregate exc10 cm in width and set in CM 1:6 complete.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Material and labour for rendering 15 mm thick in CM 1:4 on brick/precast block masonry surfaces finished even and smooth without using extra cement.
Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping including necessary form work.
Demolition of RCC in ground floors & pavings n exc 15 cm thickness (below or above ground level)
Material and labour for precast cement concrete slab for manhole covers slab 1:2:4 type B1 using 20 mm graded crushed stone aggregate set in CM 1:4
Supply and fix mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
Supply and fix mild steel TMT bars 6 to 8mm cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips for man hole cover handle.
Cleaning and dewatering of septic tanks of any size or depth including cleaning outlet and inlet chambers outlet inlet pipes grills etc of any description and removing mud solid sludge and finally washing with water for smooth functioning of sewage incl removing sludge out side MD land at places approved by Municipal authorities by Manually.
Cleaning and dewatering of Soakage well of any dia or depth including cleaning outlet and inlet chambers outlet inlet pipes grills etc of any description and removing mud solid sludge and finally washing with water for smooth functioning of sewage incl removing sludge out side MoD land at places approved by Municipal authorities by Mechanically
Supply and Fix in repair PVC (SWR) bends any radius 110mm
S&F in repair PVC (SWR) bends any radius 75mm dia
S&F in repair PVC (SWR) vent cowl 75mm dia
Supply and Fix in repair PVC (SWR) vent cowl any radius 110mm
M&L in repair PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement
M&L in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement
M&L in repair 75mm dia nahani trap, plain with grating including jointing with solvent cement
S&F (in repairs) Vitreous china, white, Squatting pan ,'Orrisa' pattern size 580x440mm with integral footrests water closet) , front or back inlet complete , connection to drain pipe and to flushing pipe , antisyphonage pipe etc complete including making good to floor to match with the exisitng all as specified
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white ( flushing cistern and flush pipe) complete all as specified
S&F in repair vitreous china wash basin (WHB) , white , flat back , size 550mmx400mm including CI cantilever brackets, 32 mm dia brass Chromium plated waste fittings with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply pipe and supply of taps complete all as specified fixed in repairs .
S & F in repair 32 mm bore low density polythene pipe (LDPE) of pressure rating 6 kgf / Sqcm for WHB and sink complete all as specified and directed.
S&F ( in repairs) Low level flushing cistern 10 ltr capacity moulded from virgin poly propylene Make Parry ware Brand Slimline Single flush including provision of 32 mm dia PVC flush pipe and making connections, ISI marked or equivalent of other make specified complete all as specified and directed. approved by GE
S&F SS Grating doom 100 mm dia with waste hole (min. weight 50 gms)
S&F in repair PVC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hanging devices.approved by GE
Taking down Chowkats or Frames, not exc. 1.50 SQUARE METRE Each with Shutters (without Taking Off Shutters from the Frames), complete all as specified and as directed.
S&F Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm palin colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section
S&F 100 mm long Stainless steel butt hinges medium weight clod rolled and fixed.
S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
S&F Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises.
S&F Non Skid white ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4)
M&L glazed ceramic white tiles 350x250x 6 to7 mm thick/450x350x6 to7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L rubber moulded chequered cement concrete tiles 30cm x 30cm x 25mm thick, with grey cement and pigment set, jointed and pointed in near cement slurry in floors over 15mm screed bed in CM ( 1 : 4)
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete.
Cleaning of blockage of WCs,bath room and blockage connected with WC sewage line to primary manholes any size and dry sewage line etc.day to day wise as per complaint slip received from concerned AGE B/R II located at NOFRA on all working day from 0900 hrs to 1700 hrs (Sunday and Holiday if any urgent requirement ) doing only by manually including all necessary T and P,contractor should provide 2 men minimum for cleaning all as specified and directed by Engr In Charge.
Dismantling water tanks & removing to store exc 250 Ltr & n exc 500 litres capacity
Dismantling water tanks & removing to store exc 500 & n exc 1000 litres
S&F Rotational moulded polythene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position 500 ltrs, including PVC float valve 20 mm bore, high pressure with polythene ball & float complete all as specified
S&F Rotational moulded polythene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position 1000 ltrs, including PVC float valve 20 mm bore, high pressure with polythene ball & float complete all as specified
S/F in repair 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified
S/F in repair 25mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified
Taking up or down 20 mm dia steel tubing and connection including cleaning for re-fixing or removal from site complete all as specified and directed
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors,including all fitttings complete all as specified. complete all as specified and directed
S & F in repair PVC sintex cover for 500 ltr / 1000 ltr PVC tank complete all as specified and as directed by Engr-in-charge.
Shine Enterprises
M/S jvsr constructions
Tara Construction
JINTECH
M/S Kartik Enterprises
M/S DUBAL CONSTRUCTION
SACHIN CONSTRUCTIONS
STAR FABRICATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .