| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | ₹14.0 L Quoted ₹14.4 L | L1 | Accepted-AOC L1 QUOTED |
| 2 | L2₹15.8 L+₹1.4 L (10.0%)Rejected-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹15.8 L+₹1.4 L (10.0%) | L2 | Rejected-AOC L2 QUOTED |
| 3 | L3₹16.4 L+₹2.0 L (14.2%)Rejected-AOC | ₹16.4 L+₹2.0 L (14.2%) | L3 | Rejected-AOC L3 QUOTED |
| 4 | L4₹18.4 L+₹4.1 L (28.2%)Rejected-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹18.4 L+₹4.1 L (28.2%) | L4 | Rejected-AOC L4 QUOTED |
| 5 | L5₹19.2 L+₹4.8 L (33.4%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹19.2 L+₹4.8 L (33.4%) | L5 | Rejected-AOC L5 QUOTED |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh, 12 Wings Air Force, Chandigarh-160003
REPAIR TO INTERNAL ELECTRIFICATION IN OTM ACCN INCLUDING SUBMAIN AND DISTRIBUTION UNDER GE (AF) CHANDIGARH
2024_MES_670163_1
GE(AF)/CHD/T-16/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF Chandigarh
₹40,000
Yes
16 Nov 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
17 Sept 2024
2 Sept 2024 - 9 Sept 2024
Amount
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including medium grade non metallic rigid PVC conduit 19mm dia or higher fixed on surface/ concealed with all standard fittings such as Tee junction, bends, on existing sunken terminal boxes for mounting modular switch/ sockets etc. including PVC insulated un-shearthed 1.5 sqmm multi-stranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity including taking down old copper/ aluminium point wiring (light, fan, socket or power) complete, including conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. for the following complete all as specified and directed:-
One light point controlled by one switch/ fan point controlled by one switch .
One three pin 6 amp socket outlet multipurpose on independent board.
One three pin 6 Amp switch socket outlet on the same board with other switches.
All as per item No 1.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete. Note for item No. 1.01 to 1.03 & 2.00 : Sunken terminal boxes/ cover plates etc. if required shall be measured and paid separately under respective item.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including PVC casing caping of suitable size with all standard fittings and existing sunken terminal boxes for mounting modular switch/ sockets etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity including taking down old copper/aluminium point wiring (light, fan, socket or power) complete and conduits/casing capings etc including making good disturbed surfaces of walls, floors etc for the following complete all as specified and directed:-
One light point controlled by one switch/ fan point controlled by one switch .
One three pin 6 amp socket outlet multipurpose on independent board.
One three pin 6 Amp switch socket outlet on the same board with other switches.
All as per item No 3.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete. Note for item No 3.01 to 3.04 & 4.00: Sunken terminal boxes/ cover plates etc. if required shall be measured and paid separately under respective item.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLSH colour coded 1100 volts grade drawn in existing conduit fixed on surface/ concealed and existing sunken terminal boxes modular switch/ sockets etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLSH colour code cable 1100 volts grade for earth continuity including taking down old copper/ aluminium point wiring (light, fan, socket or power) complete from existing concealed/ surface conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. for the following complete all as specified and directed:-
One light point controlled by one switch/ fan point controlled by one switch .
One three pin 6 amp socket outlet multipurpose on independent board.
One three pin 6 Amp switch socket outlet on the same board with other switches.
All as per item No 5.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete. Note for item No 5.01 to 5.04 & 6.00: Sunken terminal boxes/ cover plates etc. if required shall be measured and paid separately under respective item.
S&F in repairs modular switch 1 way 6 A, 1 module all as specified and directed.
S&F in repairs modular socket outlet, 2/ 3 pins combined, 6 Amps, 2 module, 230 volts all as specified and directed.
S&F in repairs modular switch 1 way 16 A, 1 module all as specified and directed.
S&F in repairs modular socket outlet, 6/ 16 Amps, 2/3 pin combined, 230 volts, 2 module all as specified and directed
S&F in repairs modular type electronic ceiling fan step regulator, 120W, 2 module for 1200/ 1400mm sweep ceiling fan complete all as specified and directed.
M&L for submain wiring complete with two runs of 4.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductor shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 6.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length.
M&L for submain wiring complete with four runs of 10.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 10.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Four runs of 10.0 sqmm multi-stranded cable and one run of 10.0sqmm cable as earth continuity conductor shall be considered as one unit length.
S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed.
S&F in replacement sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc complete with & including SP MCB 6-32 Amps, 240 volts 10 KA all as directed .
S&F in replacement MCB SP 240 volts 6 to 32 Amps 'B' curve type all as specified and directed.
S&F in replacement MCB SP 240 volts 63 Amps 'B' curve type all as specified and directed.
S&F in replacement MCB SPN 240 volts 32 to 40 Amps ‘B’ curve complete all as specified and directed.
S&F in replacement MCB TPN 240 volts 32 to 40 Amps ‘B’ curve complete all as specified and directed.
S&F in replacement of MCCB TP 63 to 100 Amps, 415 volts AC, 25 KA with adjustable thermal and magnetic setting complete all as specified and directed.
S&F in replacement of MCCB FP 100 Amps, 415 volts AC, 25 KA with adjustable thermal and magnetic setting complete all as specified.
S&F in replacement of MCCB FP 125 Amps, 415 volts AC, 25 KA with adjustable thermal and magnetic setting complete all as specified.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 12 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 4 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement 04 feet 20 watt LED batten AC decorative box type with driver, holder etc colour temp 6500K, PF >0.9 complete all as specified and directed.
S&F in replacement 02 feet 10 watt LED batten AC decorative box type with driver, holder etc colour temp 6500K, PF >0.9 complete all as specified and directed
S&F in repairs LED light fitting 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs decorative wall light, gold finish fixture with white glass diffuser suitable for 7.5 W LED filament lamp E 27 base complete all as specified and directed.
S&F in repairs ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed.
S&F in replacement rigid non-metallic PVC conduit surface/concealed 25 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. incuding repairing the disturbed surface complete all as specified and directed.
S&F PVC channels with standard slots of size 100x100mm with cover of suitable size complete all as specified and directed.
S&F in replacement call bell AC 230 volts single pole complete all as specified and directed.
S&F in replacement slim design LED surface mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 18 watt complete all as specified and directed.
S&F in replacement slim design LED recessed round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 15 watt complete all as specified and directed.
S&F in replacement slim design LED recessed/surface mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 12 watt complete all as specified and directed.
S&F in replacement slim design LED recessed/surface mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 9 watt complete all as specified and directed.
S&F in replacement LED lamp 9 watt complete all as specified and directed.
S&F in replacement 18/ 20 watt LED tube rod 4’ long (as per existing) complete all as specified and directed.
S&F in replacement LED street light fitting 60 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement LED street light fitting 45 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement eco rounded highbay LED luminaries 150 watt in PDC housing for industrial application made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP-66 protection. System efficacy not less than 110 LPW with 10 KV complete with electrical complete all as specified & directed.
M&L for replacement of LED light fitting 2 x 16/ 20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories duly prewired including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S & F in replacement PVC insulated and sheathed twin core cable with aluminium conductor 10 sqmm size 1100 volts grade complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core including taking up/ down existing cable complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed.
Returning and filling in excavated soil in layer not exceeding 25cm thick in including spreading, levelling, watering and well ramming in soft/ loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid.
Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed.
S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC surface mounting type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in replacement of LED flood light luminaries 50W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed.
S&F in replacement of LED flood light luminaries 150W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed.
S&F in replacement of LED flood light luminaries 200W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed.
S&F in replacement of LED driver suitable for 35/ 36 watt LED panel of size 600mm x 600mm fittings complete all as specified and directed.
S&F in replacement LED Twister 10 watt IP 65 protection rated LED bollard with robust design and efficient light distribution ,glare free and better uniformity, complete with all accessories prewired with fixing arrangment and connected, complete all as specified and directed.
S & F in replacement air freshner fan polycarbonate body 250 mm sweep single phase 230 volts with and including PVC shutters complete all as directed.
S&F in replacement surface mounting type plastic gang box suitable for mounting modular switch/ sockets complete with fixing plate and cover plate, made from high impact plastic with metal thread inserts complete all as directed for the following :-
For two module
For three module
For four module
For six module
&F in replacement concealed type flush mounted GI sheet metal box 18 gauge thickness suitable for mounting modular switch/ sockets complete with fixing plate and cover plate, with earthing terminal and good quality thread including making good the disturbed surfaces complete all as directed for the following:-
For two module
For three module
For four module
For six module
For eight module
For twelve module
M&L for replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge incl necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note :- Earth lead strip 25 x 4mm and GI 40mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
All as per item No 64 here in before but with 4 mm dia GI wire as earthing lead and 15 mm dia GI medium grade protection pipe.
Jai Maa Electrical Works (BID ID -3120344)
MANSA ENTERPRISES (BID ID -3101281)
M/s APEX ENTERPRISES (BID ID -3100573)
SANJEEV ENTERPRISES (BID ID -3106638)
HARISH SALES CORPORATION (BID ID -3121865)
PARTAP ENGINEERING WORKS (BID ID -3108414)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .