| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Lowest BIdder | |
| 2 | L2₹26.0 L+₹1.2 L (4.89%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹27.1 L+₹2.4 L (9.56%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹27.5 L+₹2.7 L (11.0%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹28.6 L+₹3.8 L (15.4%)Rejected-Finance 29 GANDHI NAGAR VETERINARY COLLEGE ROAD BIKANER 334001 RAJ | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
17 Nov 2023, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin 305601
REPAIR/REPLACEMENT OF UNDERGROUND CABLE, LT PANEL, CABLE/MCCBs/SECURITY LIGHT, OVER HEAD CONDUCTOR/LIGHTENING CONDUCTOR/EARTHING AT AJMER MIL STN UNDER GE NASIRABAD. NASIRABAD
2023_MES_624328_1
8381/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b i having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹70,000
Yes
30 Nov 2023
20 Oct 2023
20 Nov 2023
20 Oct 2023
17 Nov 2023
3 Nov 2023
20 Oct 2023 - 27 Oct 2023
Amount
Dismantling of unserviceable worn out / weathered / damaged ACSR conductor, service feeder of any size and type from PCC/RCC/Steel pole after disconnecting jumpers and insulator bindings complete all as specified and directed.
Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel ) complete all as specified and directed.
Dismantling of Cross arms of MS channel or angle section etc complete all as specified and directed.
Dismantling stay assembely complete with stay wire complete all as specified and directed.
Disconnecting and taking out old existing unserviceable LT under ground cable of any description and in any position from trenches/ under floor,roads,paths or from walls / from poles/ from ducts etc.complete all as specified and directed of following cross sectional area below item No 6.00, 6.01, 6.02, 6.03, 6.04, 6.05 & 6.06
Supply, Laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross sectional area 10 Sqmm, 2 core , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Make:- Havells/KEI/Finolex Note :- (i)Excavation and earth work shall be measured and paid separately under BOQ
All as per descrition of serial item No 6.00 above here-in-before but size 16 Sq mm 4 core
All as per descrition of serial item No 6.00 above here-in-before but size 25 Sq mm 4 core
All as per descrition of serial item No 6.00 above here-in-before but size 35 Sq mm 3.5 core
All as per descrition of serial item No 6.00 above here-in-before but size 50 Sq mm 3.5 core
All as per descrition of serial item No 6.00 above here-in-before but size 70 Sq mm 3.5 core
All as per descrition of serial item No 6.00 above here-in-before but size 95 Sq mm 3.5 core
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, laying of cables/pipes/poles etc., and getting out in anytype of soil, complete all as specified and directed.
All as per description of serial item No.7.00 above but exc 1.50m and n.exc 3.0m deep complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding of 25 cm thick in soft/loose soil complete all as specified and directed
Removal of surplus soil as obtained from excavation to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point, all as specified and directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-charge Note:-Punned thickness only shall be measured and paid.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.
Dismantling of old unserviceable Steel tubular pole/ struts/PCC Poles any size any type and removing from site complete all as specified and directed.
Supply ,erecting and fixing the true vertical position,steel tubular swaged pole(410 SP-31),09 mtr long, complete with cast iron base plate,pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire lenght of pole ,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.(Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed. Note:- (a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately. Make :- National Tubing Co Kanpur/Kalinga Tubes/ Bombay Tubes
M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregates as in foundation of PCC pole/struts including necessary form work, complete, all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40mm graded stone aggregates as in foundation of stay assembly etc including necessary form work, complete, all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20mm graded stone aggregates as in coping around pole including necessary form work, finisged even and fair, complete, all as specified and directed.
Dismantling cable protection pipe 40/50/80/100 mm dia. complete all as specified and directed.
Supplying and fixing 100 mm bore light grade , Galvanised mild steel pipe / tubing, complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with including suitable mild steel clamps , bolts , nuts and washers complete for cable proction all as specified and directed of following sizes:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ) Make :- BST/JINDAL/TATA
All as per item No 19.00 above 80 mm bore
All as per item No 19.00 above 50 mm bore
All as per item No 19.00 above 40 mm bore
M&L for earthing complete with galvanized steei earth plate electrode 60cm X 60cmx 6-7mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level and connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm ’bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed.
Taking down old unserviceable Street Light fittings and S&F 90W LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 120 Lumen/Watt (Minimum lumen output of luminaire should be 10800 Lumens/watt ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 10 KV surge protection driver compartment, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be potted constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire complete all as specified and directed. Make: Havells/Crompton(Crompton Cat Part NoTRP-90-57-HL2-GL-NSG or equilent)/Philips
Taking down old unserviceable Street Light fittings and S&F 70W LED street light with pressure die cast aluminum housing & IP lens Module with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 120 Lumen/Watt (Minimum lumen output of luminaire should be 8400 Lumens/watt ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 10 KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a potted constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire complete all as specified and directed. Make: Havells/Crompton(Crompton Cat Part NoTRP-90-57-HL2-GL-NSG or equilent)/Philips
Supply and fix bracket for street light fittings made out GI pipe of light grade 1.2 m long 40 mm pipe each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Taking down old unsv and Supply and fix bracket for street light fittings made out GI pipe of light grade 1.2 m long 32 mm pipe each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm MS flat fixed iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Taking down old unserviceble post top lantern and Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make :- Havells/Bajaj/Crompton
Material & Labour for applying two coats of aluminium paint on Steel tubular LT poles including painting to cross arms and clamps etc., after necessary preparation of surfaces by scrubbing and cleaning with wire brush complete all as specified & directed.
S&F in repairs IP65/IP66 Thermoplastic Polycarbonate cable Junction box for street lights; size not less than 205mm x 255mm x 112 mm suitable for cable dimensions of size 10 to 25 sq mm, with 25 sqmm terminal of 32 Amps rating for three phase & neutral mounted on din rail with locking arrangement fixed to PSC/Steel Poles by means of suitable size of clamps made of MS flat 20 x 4mm - 2 Nos with nut, bolts & double washers and including provn for fixing 01 No. single pole, MCB, 10 amps,10KA, ‘B’ series with ON/OFF flap complete all as specified and directed. Make :- Hensel Cat part No:- DK2525 G or equivalent make and model as approved by GE.
M&L for laying ACSR conductor of any size including all binding wires and aluminium jointing, jumpering etc maintaining standard sag on LT OH lines complete all as specified and directed.
Restringing, tightening of ACSR conductor of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminum binding wire on LT over head lines and fixing of GI conductor complete all as specified and directed.
M & L for cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size with welding, bending cold or hot including painting two coats of aluminium paint over a coat of primer complete all as specified and directed.
S&F pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed. (Make : BHEL/Pactil/Jaypuria Brothers)
S&F shackle type insulator, porcelain, vitreous, white, brown or green, 75 mm height 90 mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3 mm, 12 mm dia of bolts, washers and nuts complete all as specified and directed. (Make : BHEL/Pactil/Jaypuria Brothers)
Supply and fix loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90 mm, clearance of hole 16mm complete all as directed.(Make : BHEL/Pactil/Jaypuria Brothers)
Taking down old unsv timer & Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW single phase 40 Amps complete with using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature Switch operation should be based on Nautral Light Lux* level. Required illuminance level for switching ON is ≤ 60 Lux and for swiching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure ( with Hinged LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option). Make - Kakatiya Energy system Model SWADEEP-02EC-5KW1P(With SMC Enclosure Confirmingto IP 54)/Havells
Taking down old unsv timer & Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW three phase 20 Amps per phase complete with using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature Switch operation should be based on Nautral Light Lux* level. Required illuminance level for switching ON is ≤ 60 Lux and for swiching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure ( with Hinged LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option). Make - Kakatiya Energy system Model SWADEEP-02EC-5KW3P(With SMC Enclosure Confirmingto IP 54)/Havells
Dismantling and disconnecting old unserviceable MCCBs of any capacity after disconnecting all electric connections and removal from site complete all as directed.
S&F in repair MCCB, 100 Amp, 3 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
S&F in repair MCCB, 125 Amp, 3 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
S&F in repair MCCB, 160 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
S&F in repair MCCB, 200 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
S&F in repair MCCB, 250 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
S&F in repair MCCB, 400 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make :- Havells / Legrand / Schneider
Materials & labour for preparton of old steel surfaces of panel board and applying one coat of aluminium paint including numbering of panel board using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. Note:- Including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size of fixing the damaged door of busbar and panel as directed by EIC.
S & F aluminum air termination,single pointed aluminium rod 12 mm dia and 300 mm length all as specifed and directed.
S & F aluminium strip of size 25 x 3.15 mm on wall / on roof with seasoned wood block support of size 100 mm x 100 mm x 150 mm fixed on wall by 200 mm long boltsgrouted in wall / on roof and over roof with proper junction joint & bonds fastened with nuts bolts & washers/screw of size as per site requirement including connecting one end to air termination rod & another end to test point terminal box complete all as specified and directed.
M/s SUNIL ENTERPRISES
DEMROT ELECTRICAL WORKS
M/S SHIVA TRADERS
MITTAL ENTERPRISES
Nvimal Engineers and Contractor
PD GUPTA AND COMPANY
Shikha Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .