| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.8 L+₹3.0 L (8.22%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹42.9 L+₹7.0 L (19.4%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹43.2 L+₹7.4 L (20.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER | |
| 5 | Rejected-Technical | - | Rejected-Technical Contractor requested not to open their Tech/Fin Bid vide letter no. Nil dated 30 Nov 2023 Uploaded |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Dec 2023, 6:00 pmClosed
GE Amritsar
GE Amritsar pin 143001
REPAIR AND MAINTENANCE OF DG SETS INCLUDING ATTENDING COMPLAINTS AND CONNECTED ITEMS AT GG FORT AND OLD AMRITSAR CANTT.
2023_MES_614597_2
GE/ASR-38/2023-24
Open Tender
Civil Works
Works
210 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
20 Sept 2024
7 Nov 2023
2 Dec 2023
7 Nov 2023
1 Dec 2023
18 Nov 2023
Amount
Material & Labour for supply, carrying out B check maintenance repairs in 250 KVA Cummins DG set including the replacement of fuel filters, lub oil filters, SLO by pass filters and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for supply, carrying out B check maintenance repairs in 160 KVA / 125 KVA Cummins DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for supply, carrying out B check maintenance repairs in 100 KVA / Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for supply, carrying out B check maintenance repairs in 63KVA / Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for supply, carrying out B check maintenance repairs in 35KVA / 25KVA Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for supply, carrying out B check maintenance repairs in 10 KVA Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Air cleaner elements for 250 KVA DG sets as per manufacture/make existing at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Air cleaner elements for 160/125 KVA DG sets of original make/manufacturer as per existing in DG Set at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Air cleaner elements for 100 KVA DG sets of original manufacture/make existing at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Air cleaner elements for 63 KVA DG sets of original manufacture/make existing at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Air cleaner elements for 10 to 35 KVA DG sets of original manufacture/make existing at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply only coolant concentrate for radiator of DG set of any capacity as per manufacture ; complete all as specified and directed by the Engineer-in-Charge. Make :- Indian Oil / Hindustan Petrolium / Castrol / Servo
Supply only distilled water for radiator and batteries of DG set ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling, transporting, repairs , calibration, testing and commissioning of PT fuel pump for 250 KVA DG set including the replacement of all service kits ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling, transporting, repairs and calibration, testing and commissioning of PT fuel pump for 160/125 KVA DG set including the replacement of all service kits ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling, transporting, repairs and calibration, testing and commissioning of PT fuel pump for 63/100 KVA DG set including the replacement of all service kits ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling, transporting, repairs and calibration, testing and commissioning of PT fuel pump for 10 to 35 KVA DG set including the replacement of all service kits ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement AVR suitable for 250 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge. Make; Kirloskar / Altex
Supply & Fixing in replacement AVR suitable for 160/125 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge. Make; Kirloskar / Altex
Supply & Fixing in replacement AVR suitable for 100/63 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge. Make; Kirloskar / Altex
Supply & Fixing in replacement AVR suitable for 10 to 35 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge. Make; Kirloskar / Altex
Material & Labour for painting incl cleaning of DG Set with canopy complete including alternator and Engine and all area of DG Set of Cap 250 KVA /160 KVA/125 KVAby applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting followed by two coats of primer after preparation of old paint surface cleaning and scrapping and sticker pasting of MES No., DG set ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for painting incl cleaning of DG Set with canopy complete including alternator and Engine and all area of DG Set of Cap 100/63 KVA by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting followed by two coats of primer after preparation of old paint surface cleaning and scrapping and sticker pasting of MES No., DG set specification, etc ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of lead acid battery 12 Volts DC 180 AH including the initial charge, terminals connector ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of lead acid battery 12 Volts DC 150 AH including the initial charge, terminals connector ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in servicing of alternator capacity 250 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, greasing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in servicing of alternator capacity 160/125 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, greasing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in servicing of alternator capacity 100 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, greasing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in servicing of alternator capacity 63 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, greasing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in servicing of alternator capacity 10 to 35 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, greasing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour in replacement of battery lead 1.25 metre long consisting of multistranded copper conductor PVC insulated single core cable of 25 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Fuel metalic braded Flexible Pipe for DG set of cap 250 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Fuel metalic braded Flexible Pipe for DG set of cap 160/125 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Fuel metalic braded Flexible Pipe for DG set of cap 100/63 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Fuel metalic braded Flexible Pipe for DG set of cap 10 to 35 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Hose Pipe for DG set of cap 250 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Hose Pipe for DG set of cap 160/125 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Hose Pipe for DG set of cap 100/63 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Hose Pipe for DG set of cap 10 to 35 KVA ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in replacement of Fan Belt ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for disconnecting , taking down , dismantling , opening up complete DG set of cap 63/100 KVA and carry out top overhauling of DG set to the entire satisfaction of AGE E/M and refixing the same at its positions ; complete all as specified and directed by the Engineer-in-Charge with & including following :- (i) Opening of top head of the engine. (ii) Replacement of valve guide set. (iii) Replacement of valve seat. (iv) Replacement of head gasket. (v) Replacement of tappet cover gasket. (vi) Tappet setting. (vii) Sealing with anabond liquid.
Material & Labour for disconnecting , taking down , dismantling , opening up complete DG set of cap125/160 KVA and carry out top overhauling of DG set to the entire satisfaction of AGE E/M and refixing the same at its positions ; complete all as specified and directed by the Engineer-in-Charge with & including following :- (i) Opening of top head of the engine. (ii) Replacement of valve guide set. (iii) Replacement of valve seat. (iv) Replacement of head gasket. (v) Replacement of tappet cover gasket. (vi) Tappet setting. (vii) Sealing with anabond liquid.
Material & Labour for disconnecting , taking down , dismantling , opening up complete DG set of cap 200/250 KVA and carry out top overhauling of DG set to the entire satisfaction of AGE E/M and refixing the same at its positions ; complete all as specified and directed by the Engineer-in-Charge with & including following :- (i) Opening of top head of the engine. (ii) Replacement of valve guide set. (iii) Replacement of valve seat. (iv) Replacement of head gasket. (v) Replacement of tappet cover gasket. (vi) Tappet setting. (vii) Sealing with anabond liquid.
Material & Labour for repairs/overhauling of self starter including replacement of armature, carbon brushes, brackets, bearings etc for 24 volt Lucas ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for repairs/overhauling of self starter including replacement of armature, carbon brushes, brackets, bearings etc for 12 volt Lucas ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for dismantling the battery charger alternator from engine, carry out repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 250/160 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for dismantling the battery charger alternator from engine, carry out repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 125/100 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for dismantling the battery charger alternator from engine, carry out repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 63 KVA DG set ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of MCCB 4 Pole, 415 V, thermally Adjustable type, 400 Amps with breaking capacity 36 KA with spreader terminals on incoming and outgoing sides; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of MCCB 4 Pole, 415 V, thermally Adjustable type, 250 Amps with breaking capacity 36 KA with spreader terminals on incoming and outgoing sides; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of MCCB 4 Pole, 415 V, thermally Adjustable type, 200 Amps with breaking capacity 36 KA with spreader terminals on incoming and outgoing sides ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of on-load change over switch side handle 415 volts 4 pole 200 Amp including connection ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of on-load change over switch side handle 415 volts 4 pole 100 Amp including connection ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for repairs to doors of canopy of DG sets ; dismantling the doors & repairs the door by disconnecting nut bolts , replacing handles , locking arrangement , staples or steel pins, nut bolts , washers & painting the doors to match with canopy and refixing the doors after repairs and make it functional to the entire satisfaction of the AGE E/M ; complete all as specifed and directed by Engineer-in-Charge.
Material and lobour for cleaning of DG set radiator of any capacity by taking down it from its base taking to factory / work shop cleaning with acid, repairsing by brazing wherever required and reinstalling & fixing in its position after repairs & make it functional to the entire satisfaction of the AGE E/M ; complete all as specifed and directed by Engineer-in-Charge.
Supply only petroleum jelly for battery terminals ; complete all as specifed and directed by Engineer-in-Charge.
Supply only cell tester for batteries of capacity 12/24 volts ; complete all as specifed and directed by Engineer-in-Charge.
Supply only hydrometer for testing of battery water specific gravity ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing in replacement water pump of DG set 63/100 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing in replacement water pump of DG set 125/160 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing in replacement water pump of DG set 200/250 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing thermostatic valve for DG set of capacity 63/100 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing thermostatic valve for DG set of capacity 125/160 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing thermostatic valve for DG set of capacity 200/250 KVA of make/manufacturer as orginal existing in DG set at site ; complete all as specifed and directed by Engineer-in-Charge.
Material and labour for cleaning of fuel tank of DG set of capacity 63/100 KVA ; by disconnectiong, taking out and cleaning fuel tank manually as well as mechanically and also using cleaning compound and make fuel tank neat & tidy and refixing in its position ; complete all as specifed and directed by Engineer-in-Charge.
Material and labour for cleaning of fuel tank of DG set of capacity 125/160 KVA ; by disconnectiong, taking out and cleaning fuel tank manually as well as mechanically and also using cleaning compound and make fuel tank neat & tidy and refixing in its position ; complete all as specifed and directed by Engineer-in-Charge.
Material and labour for cleaning of fuel tank of DG set of capacity 200/250 KVA ; by disconnectiong, taking out and cleaning fuel tank manually as well as mechanically and also using cleaning compound and make fuel tank neat & tidy and refixing in its position ; complete all as specifed and directed by Engineer-in-Charge.
Material and labour in replacement of control wiring of DG set of capacity 63KVA to 250 KVA of original make/manufacturer as per existing in DG Set at site ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Battery charger with SMPS technology suitable for charging battery of DG set 12 Volts 180 AH rating ; complete all as specifed and directed by Engineer-in-Charge. Make:- NHP, MNM, TEKNIKA, AE, Max Power
Supply and fixing in replacement Battery charger with SMPS technology suitable for charging battery of DG set 24 Volts 180 AH rating ; complete all as specifed and directed by Engineer-in-Charge.Make:- NHP, MNM, TEKNIKA, AE, Max Power
Supply and fixing in replacement controller of DG set of any make & of capacity 63/100/125 KVA ; of original make/manufacturer as per existing in DG Set at site ; complete all as specified and directed by the Engineer-in-Charge.Make :- Kirloskar / Cummins
Supply and fixing in replacement controller of DG set any make of capacity 160/200/250 KVA of original make/manufacturer as per existing in DG Set at site ; complete all as specified and directed by the Engineer-in-Charge.Make :- Kirloskar / Cummins
Supply and fixing in replacement digital Voltmeter 96x96mm suitable for 415V , 50Hz ; complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing in replacement digital Ammeter as per sample complete all as specifed and directed by Engineer-in-Charge.
Material and labour for repairs Maint / overhauling of diesel engine 20 BHP make kirloskar type DA 20 complete incl replacement of fuel and oil filters, Engine oil and hoses fuel etc ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for repairs/ overhauling of pump make kirloskar model DB 50/26 driven by diesel engine incl replacement of bearings, sleeves , gland etc ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Fire fighting hose 63 mm dia 30 mtrs long RRL type ISI marked complete with suitable nozzle SS grade ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL ( Double contactor) suitable for 160KVA DG set of any make. The Control Panel will be free standing, floor mounting, cubical type, front operated dust and vermin proof, fabricated out of 14 SWG MS CRCA Sheet duly powder after necessary pre‐treatment process & consisting of following :- (i) Power Circuit :- for Mains and DG Set- 4P contactor heavy duty suitably rated- 02 Nos each for main and DG supply. (ii) 3P MCCB suitably rated 02 Nos- one each for Mains and DG supply. (iii) Control & Metering Circuit-1 No. KOEL Green EMS Microprocessor based AMF logic controller-1 No. (iv) MF meter- 1 No. (v) Line Voltage Monitor L&T make- 1 No. (vi) Set of Control Fuses 1 No. (vii) Static Battery charger circuit with on / off switch. Battery charger “ON” indication (viii) Reverse Polarity indication-1 No. (ix) DC battery charging ammeter-01No. ; complete all as specified and directed by the Engineer-in-Charge.
Shifting of DG set of capacity 63/100 KVA with the help of crane and positioing all as directed incl dismantling the elect and earth connections and reconnecting earthing and connecting after errection ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 25 x 4mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion ; complete all as specified and directed by the Engineer-in-Charge. Note:- i) Cost of GI strip 25 x 4mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in quoted rates.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion ; complete all as specified and directed by the Engineer-in-Charge. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Attending emergency complaints for DG set ( diesel engine or alternator) not working within 8 hrs after intimation from JE /AGE to the contractor or his rep for repairs of urgent nature ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Cast iron ball type foot valve 80 mm dia with synthetic metal ball PN rating 1.6 make Kratar/ Normex/ LP valves ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement radiator copper suitable for diesel engine of fire fighting pump set Engine Kirloskar Model DA 20 , 20 BHP make -Benco or equivalent ; complete all as specified and directed by the Engineer-in-Charge.
Supplying,installation, testing & commissioning of Retrofit Emission Control Device on existing 100/125 KVA Diesel Generator set of any make/Vintage to reduce particulate matter, Hydrocarbon and Carbon Monoxide emmision by atleast 70% in 5 mode D2 cycle. The emission control device/equipment must be tested over an ISO-8187 5 mode D2 cycle for equivalent KVA rating and consisting of pressure safety valve of SS304, Oxidation chamber particulate matter trap of IS 2062 grade B with high temprature resistant paint, vibration damper & gasket, shielding including nut,bolt,clamp etc and guarding of insulation with SS202 cladding, making structure & ladder of IS 2062 grade B with high temprature resistant paint, Manual exhaust bypass system present - A mannual will be given after the first stage (Oxidation stage) and before the second stage (Passive Regenerative Trap) of the DOFF, Noise attenuation is within the permissible limits, Equipped with mechanical pressure relief system, Capturing chamber made of resistance process treated Mild steel etc complete all as specified & directed. Make :- KOEL,Mahindra,Cummins, Ashok leyland or Crompton greaves OR equivalent approved by E-in-c Br ; complete all as specified and directed by the Engineer-in-Charge. Notes:- (a) Above scope of work includes complete supply of device along with control panel at site. (b) Installation of the RECD device on the diesel genset. (c) RECD testing and Commissioning after fitment on load . (d) All related activities to ensure RECD is supplied, installed and commissioned on the DG Set. (e) Any other/civil work reqd on site to make space for the device fitment will be done by the contractor without any extra cost to the Govt.(f) Providing of certificate from any 1 of the 5 NABL labs recognised/approved by the CPCB to reduces PM 2.5 to 10% of the fitment and makes the DG set Compliant to the CAQM directive.(g) The RECD shall be provieded as per latest CPCB norms and suitable for DG set of year of manufacturing 2011 and 2018.
Supplying,installation, testing & commissioning of Retrofit Emission Control Device on existing 160 KVA Diesel Generator set of any make/Vintage to reduce particulate matter, Hydrocarbon and Carbon Monoxide emmision by atleast 70% in 5 mode D2 cycle. The emission control device/equipment must be tested over an ISO-8187 5 mode D2 cycle for equivalent KVA rating and consisting of pressure safety valve of SS304, Oxidation chamber particulate matter trap of IS 2062 grade B with high temprature resistant paint, vibration damper & gasket, shielding including nut,bolt,clamp etc and guarding of insulation with SS202 cladding, making structure & ladder of IS 2062 grade B with high temprature resistant paint, Manual exhaust bypass system present - A mannual will be given after the first stage (Oxidation stage) and before the second stage (Passive Regenerative Trap) of the DOFF, Noise attenuation is within the permissible limits, Equipped with mechanical pressure relief system, Capturing chamber made of resistance process treated Mild steel etc Make :- KOEL,Mahindra,Cummins, Ashok leyland or Crompton greaves OR equivalent approved by E-in-c Br ; complete all as specified and directed by the Engineer-in-Charge. Notes: (a) Above scope of work includes complete supply of device along with control panel at site. (b) Installation of the RECD device on the diesel genset. (c) RECD testing and Commissioning after fitment on load . (d) All related activities to ensure RECD is supplied, installed and commissioned on the DG Set. (e) Any other/civil work reqd on site to make space for the device fitment will be done by the contractor without any extra cost to the Govt.(f) Providing of certificate from any 1 of the 5 NABL labs recognised/approved by the CPCB to reduces PM 2.5 to 10% of the fitment and makes the DG set Compliant to the CAQM directive. (g) The RECD shall be provieded as per latest CPCB norms and suitable for DG set of year of manufacturing 2012.
TARA ENTERPRISES
Northern cable fault locatoers
Bains Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .