Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹37.9 L+₹3.2 L (9.25%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹42.6 L+₹7.9 L (22.8%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹43.5 L+₹8.7 L (25.2%)Rejected-Finance VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹43.7 L+₹9.0 L (25.9%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹46.7 L
EMD Value
₹93,440
Closing Date
2 Jun 2020, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR C/O 56 APO
SPL REPAIR OF BLDG NO NP05 ADDN/ALTN OF DRAINAGE SYSTEM AND OTHER ALLIED WORKS NEAR BLDG NO NP06, PROVN OF RETAINING WALL NEAR BLDG NO NP05 AND NP06 DRAINAGE SYSTEM AND PROTECTIVE WORK IN FRONT OF BLDG NO NP156 AT HELIPAD COLONY AUGMENTATION OF
2020_MES_339254_1
GE/S(U)-04/2020-21
Open Tender
Civil Works
Item Rate
240 days
HELIPAD COLONY 14 FD UDAMPUR
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH UDHAMPUR
₹93,440
Yes
14 Dec 2020
17 Apr 2020
4 Jun 2020
17 Apr 2020
2 Jun 2020
2 May 2020
17 Apr 2020 - 25 Apr 2020
Amount
Excavation over areas exceeding 1.5 m and not exceeding 3.00 m in depth getting out as in any type of soil complete all as specified and directed.
PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundations and mass concrete complete all as specified and directed.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 Metre mean radius in cement mortar 1:6 complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soft/ disintegrated rock complete all as specified and directed.
Removing excavated material exceeding 250 m but not exceeding 500 m and deposited where directed complete all as specified and directed.
Use and waste of form work to sides of footings, rough finished flat surfaces complete all as specified and directed.
Use and waste of form work to sides of retaining wall etc rough finished surfaces complete all as specified and directed.
RCC M 25 design mix (using 20 mm graded stone aggregate) as in foundation footing complete all as specified and directed.
RCC M 25 design mix (using 20 mm graded stone aggregate) as in walls, slab, bends etc. complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over cut to lenth, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on fair faces of concrete surfaces finished fair and even without using extra cement complete all as specified and directed.
Boulder pitching is grouted with cement and sand mortar 1:6 hand packed tightely complete all as specified and directed
Preparation of new plastered surfaces and applying two coats of cement based paint over a coat of chalk whiting complete all as specified and directed.
PCC type B-1 (1:2:4) (using 20 mm graded cushed stone aggregate) as in coping, benching and the like including form work complete all as specified and directed.
PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in surface channel and drains including necessary formwork and extra forming fair finsished drain or channels for inner girth in cement concrete etc complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Hardcore of broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm and deposited spread and levelled in layers not exceeding 15 cm thick watered and rolled/rammed to a true surface complete all as specified and directed.
150 mm thick cement concrete type C-2 1:3:6 (40 mm graded aggregate) as in flooring complete all as specified and directed including necessary form work.
Hand packing (any thickness) at back of walls over arches etc and raising (or lowering) to the required level complete all as specified and directed.
110 mm dia PVC (SWR) pipes single socketed in any length as in weepholes of retaining wall complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations etc and getting out as in any type of soil complete all as specified and directed.
Removing excavated soil material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the base in soil complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia as in reinforcement cut to length, bent to shae required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (anealed not less than 0.9 mm dia) complete all as specified and directed.
RCC 1:1.5:3 type A-1 (using 20 mm graded aggregate) as in beams, lintels complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, lintels etc rough finished surfaces complete all as specified and directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40 mm to face stones and dressing of face beds and joints, as specified, of random rubble walling uncoursed or brought up to courses complete all as specified and directed.
300 mm bore of pipe reinforced concrete pipes, class NP-2 laid and jointed complete with collars as in repair complete all as specified and directed.
Providing cement concrete type B-0 (1:2:4) (using 12.50 mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed.
15 mm thick rendering in two layer (10 mm + 5 mm) on fair faces of brick/concrete surfaces of walls in cement mortar 1:4 and finished even and fair without using extra cement complete all as specified and directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) complete all as specified and directed.
Bush cutting/jungle clearance including removing the debris to near by low laying areas complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed.
Providing cement concrete 75 mm thick type D-2 1:4:8, (using 40 mm graded stone aggregate) as in sub base or sub floor etc complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and directed.
Vitrified light shade ceramic tiles 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Applying one coat birla wall care putty on old plastered on walll surfaces including preparation of surface by brooming down or steel wie brushing, scrapp vegetation growth, efforscent salts and trading with oil greasy spot complete all as specified and directed with complete removing.
Preparation of old plastered surfaces of walls and appling two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
Backing coat of cement mortar 10 mm thick in 1:3 to receive tiles in vertical surfaces complete all as specified and directed.
Wall cladding colour tiles of size 300 mm x 600 mm x 7 mm thick (As aproved by GE) set in neat cement slurry laid over and including screed bed/backing layer of rendering 10 mm thick in cement mortar 1:4 and pointed in white/coloured cement to match set and jointed in neat cement slurry and pointed with white or colored cement to match the colour of tiles as on vertical surfaces such as dado/ skirting complete all as specified and directed.
Taking down cement plaster any description on brick or stone or cement concrete surfaces of wall including raking out joints, hacking for key, scrubbing down with water etc including removing the rubbish/debries outside MoD land complete all as specified and directed.
15 mm thick rendering in cement mortar 1:6 on other than fair face of brick or concrete surface complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
Preparation of old painted surfaces and applying one coats of acrylic weather proof exterior emulsion paint on walls, cornices complete all as specified and directed.
Water closet single piece EWC with soft close seat cover and twin flush fitting (as approved by Engr-in-Charge) fixed in repairs complete all as specified and directed. Make : VGS-WHT-81851SN size 710 x 390 x 710 mm Cat Part No VGS-WHT-81851SN (lvory color) or equivalent in Jaquar/Kohler.
Bathroom shower panel with and including all necessary CP fittings approved and complete all as specified and directed by Engr-in-Charge. Make : Jaquar, Cat Part No JPL-BLK-ST86112 (Glassy Black) or equivalent in Kohler/Cera.
450 mm long braided hose with M10X1 Nipple 15 mm Nut, O ring and rubber washer (suitable for geyser) complete all as specified and diercted. Make : Jaquar, Cat Part No ALD 805B or equivalent in Kohler/ Cera.
450 mm long braided hose with M10X1 Nipple 15 mm Nut, O ring and rubber washer (suitable for basin mixer) fixed in repair complete all as specified and diercted. Make : Jaquar, Cat Part No ALD 805B or equivalent in Kohler/Cera.
Screed bed or bedding layer of mortar 15 mm thick cement mortar 1:6 for laying floor finishes complete all as specified and directed.
25 mm thick PCC type B-0 (using 12.50 mm graded stone aggregate) as in sub base for receiving floor finishes complete all as specified and directed.
Glazed ceramic tiles of size 350 x 250 x 7 mm thick coloured tiles on vertical surfaces set and jointed in neat cment slurry and pointed in white cement mixed with colour pigments to match the existing surface complete all as specified and directed.
Digital coloured vitrified tiles (size not exceeding 0.36 sqm) and 10 mm thick as in floors jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. Note : The contractor shall have no claim on difference what so ever on shade/colour of tile.
Hardcore with broken stone or boulders of gauge not exceeding 63 mm deposited, spreading and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Screed bed or bedding layer of mortar 20 mm thick cement mortar 1:6 for laying floor finishes complete all as specified and directed.
Coloured chequred tiles lacquer finish of size 30 cm x 30 cm x 20-25 mm thick, set jointed and pointed in neat cement slurry as in path with white cement and pigment etc complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:4 on Stone masonary surface or other than fair faces of brick or concrete surfaces finished even and fair (without using extra cement) complete all as specified and directed.
Excavation over area not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Taking down carefully, copper/aluminum point wiring (light, fan, socket or power/LED Light fittings) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed. Keeping the LED lights in safe custody.
Point wiring for one light/fan/bell point controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistranded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular metal flush boxes thickness (1.25 mm) & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts copper conductor cable 1.5 Sqmm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per ser item No 59 but for 3 pin 6 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 59 but for 5 Pin 6 Amps socket outlet independent with cable 2.5 Sqmm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
All as per ser item No 59 but for 3 Pin 15 Amps socket outlet independent with cable 4.0 Sqmm including copper PVC insulated PVC unsheathed 2.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
Switch Piano flush type 6 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Switch Piano flush type 16 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Socket 2-in-1, 3 Pin 6 Amps (Modular Type) with outer strip complete all as specified and directed.
Socket 2-in-1, 3 Pin 6 & 16 Amps (Modular Type) with outer strip complete all as specified and directed.
Bell push 230 volts, AC complete all as specified and directed. Make - Havells/ Anchor /Kolors
Call bell ding-dong 230 volts including taking down old one complete all as specified and directed. Make - Anchor/Havells/Kinjal
Electronic step type fan regulator 120 watt 230 volts 50 C/S deluxe modular type complete all as spcified and directed. Make - Anchor/Havells/Kinjal
Ceiling rose surface bakelite 3 terminals complete all as specified and directed. Make : Cona Cat Part No 2126/SSK Cat Part No 572 or equivalent of make in Havells/Anchor/ Kolors.
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of complete all as specified and directed.
Re-fixing only Ceiling fan/Exhaust fan and cable of existing fans complete all as specified and directed.
Replacement MCB DB TPN 100A Double door 04 Way IP43 with MCCB Box complete all as specified and directed. Make : C&S, Cat Part No : CSDBMCCB100DD04IP43 or equivalent Standard/Legrand.
1 x 40W Candle E14 wall mounted fancy light, SS finish fixture with opal glass diffuser suitable for 40W incandescent candle lamp complete all as specified and directed. Make : Havells Cat Part No LHJE03104499 or equivalent to Philips/Bajaj/C&S
Replacement of LED bulk head luminaire, 10 W (ENDURA RUGBY) 230 Volts wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge. Make : Havells, Cat Part LHEOAOP7U26WO10 or equivalent Wipro/ Bajaj.
Replacement Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Replacement MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps complete all as specified and directed. Make : Indoasian, Cat Part No : 811015 or equivalent Standard/Legrand.
Replacement MCB Single Pole and Neutral , 230 Volt, Raiting 35 to 63 Amps complete all as specified and directed. Make : Indoasian, Cat Part No : 811037 or equivalent Standard/ Legrand.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead complete all as specified and directed. Including taking down old sub main wire.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 2.5 Sqmm as earth lead complete all as specified and directed. Including taking down old sub main wire.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board complete all as specified and directed and testing completion.
Trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 4 core size complete all as specified and directed. Make-KEI/ Finolex/ Polycab. Note : Earth work and other connected work shall be measured and paid sperately.
Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and directed. Note : for payment purpose punned thickness shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed.
GI tubing light grade 25 mm dia along the wall /in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and directed.
khajuria builders
s l sharma and sons
KALSOTRA CONSTRUCTION CO
VARDHMAN INTERNATIONAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .