| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.3 LAccepted-AOC 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-1 | Accepted-AOC Being lowest and reasonable. | |
| 2 | L-2₹40.1 L+₹3.8 L (10.5%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L-2 | Rejected-Finance Not being lowest bidder. | |
| 3 | L-3₹40.9 L+₹4.6 L (12.7%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-3 | Rejected-Finance Not being lowest bidder. | |
| 4 | L-4₹43.6 L+₹7.3 L (20.0%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L-4 | Rejected-Finance Not being lowest bidder. | |
| 5 | L-5₹49.6 L+₹13.3 L (36.5%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-5 | Rejected-Finance Not being lowest bidder. |
Tender Value
₹73 L
EMD Value
₹1.3 L
Closing Date
1 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
SPL REPAIR OF BLDG NO P-53/1-12 AND P-46/1-4 UNDER GE(S) BATHINDA AT BATHINDA MIL STN (Job No. 81 SA/BTD/SR(BLDG)-26/2023-24)
2024_MES_649757_1
CWE BTD/TOKEN-45/2023-24
Open Tender
Civil Works
Item Rate
270 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (South) Bathinda
₹1.3 L
HQ CWE Bathinda
31 Aug 2024
9 Apr 2024
3 Jun 2024
9 Apr 2024
1 Jun 2024
17 May 2024
23 Apr 2024
Amount
Supply and fixing in repairs, Bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, with wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge.
Supply and fixing in repairs, stop valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge.
Supply and fixing in repairs, concealed type stop valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge.
Supply and Fixing in repair 20 mm bore Gun metal globe or Gate valve with iron wheel head , screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge.
Supply and fixing in repair brass chromium plated shower rose size 150mm x 150mm with swivel joints with and including suitable shower arm of any size complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs PVC waste pipe with socket suitable for connection to Waste fittings of 32/40mm dia. and of length minimum 75 cm complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs PVC connections 15 mm size with brass check nuts and washers of length 450 mm complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs vitreous china (white) squatting pan 'Orissa' pattern, white, size 580mm x 440 mm, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flush pipe, anti-syphonic pipe etc including making good to floor and including trap set, in and including material and labour for lime concrete with 40mm graded stone aggregate with lime mortar 1:3 complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs Vitreous china wash hand basin, white, flat back, size 450mm x 300 mm including cast iron cantilever bracket 32 mm dia , with and including brass waste coupling and and union complete all as specified and as directed by Engineer-in-charge.
Supply and fixing sink with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x460mm , bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 32/40mm waste fittings for stainless steel sink (sink coupling), brass chromium plated for glazed ware sink, basins etc. with long screwed shanks and fly nuts, flange end ,bedded in red lead cement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stainless steel plate rack of size 900mm x 600 mm x 250mm made of 1.00mm thickness of SS sheet and fixed on wall etc. complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Cutting holes in brick walls built in cement mortar exceeding half brick but not exceeding one brick for inserting hold fast and making good dismantled portion in CM 1:3 or Cement concrete 1 : 2 : 4 , type B1 as required , dDepth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repairs PVC valve less, syphonic action type, flushing cistern, 10 liters capacity (Dual Flush), low level, white, with inlet, ball valve, float and handle including brackets and PVC bend long type and connection to flushing pipe of any size and pattern complete all as specified and as directed by Engineer-in-charge. Note: PVC Flush pipe shall be measured and paid seperately under respective item of Schedule 'A' BoQ.
Supply and fixing in repairs PVC 32mm dia , 90cm long white flush pipe of polythene of high density and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in 'repair' Chromium Plated Stainless Steel Grating of size 125mm (with or without waste hole) fixed on floor / nahani trap etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs Stainless steel drapery rod (conduit) of dia not less than 25mm and 1 mm minimum thickness of rod, including brackets / side holders etc as per site requirement fixed to walls with rawl plugs and steel screws complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Engineer-in- charge.
Dismantling CI soil vent pipe of 100 mm bore fixed with wall including all fittings & accessories complete all as specified and as directed by Engineer-in- charge.
Dismantling CI soil vent pipe of 75 mm bore fixed with wall, including all fittings & accessories complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing 75 mm dia cast iron soil waste & vent pipe in any length with or without ears fixed, with chemical cement joints, fixed with wall with MS clamps made out with 25mm x 3mm flat iron complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing 100 mm dia cast iron soil waste & vent pipe in any length with or without ears fixed, with chemical cement joints, fixed with wall with MS clamps made out with 25mm x 3mm flat iron complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing 100 mm dia cast iron soil waste & vent pipe in any length with or without ears fixed, with chemical cement joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in repair 100mm dia Cast iron bend (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in repair 75mm dia cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in repairs 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in repairs 75 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repais 100 mm cast iron sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repais 100 mm bore cast iron cowl complete all as specified and directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and directed by Engineer-in-charge.
Supply and Fixing GI tubing medium grade ISI marked with all new fittings and fixed to walls & ceiling or laid in floors, bore of pipe 15 mm and making good as per existing surfaces complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing GI tubing medium grade ISI marked with all new fittings and fixed to walls & ceiling or laid in floors, bore of pipe 20 mm and making good as per existing surfaces complete all as specified and as directed by Engineer-in- charge.
Refixing old GI tubing 20 mm bore pipe reterived from serial item no.32.00 here-in-before after cleaning and connections in new or old position , with new fittings and fixed to walls & ceilings or laid in floors and making good as per existing surfaces complete all as specified and directed by Engineer-in-charge Note:- The rate of cleaning of surfaces of old pipe is included in this item.2 The rate of new fiitings is also included in this item. Hence old fittings shall not be used in this item.
Supply only Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, three layered, ISI marked with closed top), hoisted and fixed in position including making inlet and out let connection for fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. Note: Ball valve and Gate valve shall be measured and paid seperately under respective items of Schedule 'A' BoQ as supply only and labour element is included in this item.
Supply and fixing 110 mm bore PVC (SWR) pipe of 6.00kg per sqcm pressure single socketed in any length with rubber ring joints fixed with wall with MS clamp made out with 25mm x 3mm flat iron and fixed with 75mm long screws with PVC guties not exceeding 1.80mtr c/c distance complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 110 mm bore PVC (SWR) bend /tee / shoe any type complete all as specified and as directed by Engineer-in- charge.
Material and labour Mild steel framed work of Gde Fe 290. Gde-E-165 quality - A as in door chowkats (single or double) of angles or other section with gusset plates, rails, braces, bands straps, hold fast grill, sink brackets, cooler stand etc. complete and including necessary welding for fixing flat iron, for fixing hooks and hinges complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge.
Material & Labour for welding in repairs with thickness of metal not exceeding 6.00 mm and not exceeding 2.50 cm in length c complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 300mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminium barrel tower bolts, 200 mm long, stove enamelled black with bright bolts and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fixing aluminium handle oval type size of 150mm ISI Marked complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing hasp & staple 100mm size, safety type, stainless steel rust free with mild steel hinge pin including bolt to hinge plated and fixed with screws complete all as specified and directed by Engineer-in-Charge.
BLANK
Supply & fixing for 4.00 mm thick, sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
Supply & fixing for 4.00 mm thick, figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
Dismantling boarding any descrption fixed in any position with rails including fillets complete all as specified and as directed by Engineer-in- charge.
Material and Labour 18/19mm thick Prelaminated particle board, exterior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed by Engineer-in- charge.
Material and Labour 2nd Hard Wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails/brads or secured with screws, cross sectional area exc 3 sqcm and n. exc 6 sqcm, complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frame with shutter (without taking off shutters from the frames) not exceeding 1.5 Sqm each and removal from site complete all as specified and as directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and as directed by Engineer-in- charge.
Taking down wooden shutters of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Pressed steel frame size 125mm x 60mm , with thickness of steel sheet 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including one shop coat of priming complete all as specified and as directed by Engineer-in-charge. Note:-(a) The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6 and matching the colour of new plaster with existing surface. Nothing extra shall be paid on this account. (b) The rate of fixing of Butt hinges is included in this item and butt hinges shall be measured and paid under respective item of Schedule 'A' BoQ.
Supply and fixing Pressed steel frame size 105mm x 60mm , with thickness of steel sheet 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including one shop coat of priming complete all as specified and as directed by Engineer-in-charge. Note:-(a) The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6 and matching the colour of new plaster with existing surface. Nothing extra shall be paid on this account. (b) The rate of fixing of Butt hinges is included in this item and butt hinges shall be measured and paid under respective item of Schedule 'A' BoQ.
Supply and fixing Pressed steel frame size 75mm x 60mm , with thickness of steel sheet 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including one shop coat of priming complete all as specified and as directed by Engineer-in-charge. Note:-(a) The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6 and matching the colour of new plaster with existing surface. Nothing extra shall be paid on this account. (b) The rate of fixing of Butt hinges is included in this item and butt hinges shall be measured and paid under respective item of Schedule 'A' BoQ.
Material and labour for PCC 1:3:6 type C1 (using 20mm graded crushedstone aggregates) as in filling back of pressed steel door frames/chowkhats and for fixing hold fasts, etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
Supply and Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (Bonsum/ Hollock) edges of frming plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge. Note:- Wire gauze/ glass to be measured and paid separately.
Supply and Fixing Factory made 35mm thick Plain framed, panelled shutter (two panel) , using 2nd class Hard wood for rail and style ,with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedcomplete all as specified and as directed by Engineer-in-Charge
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with one shop coat of zinc chromate primer with glazing bars complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with one shop coat of zinc chromate primer without glazing bars complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay,with one shop coat of zinc chromate primer complete all as specified & as directed by Engineer-in- charge.
Supply and fixing repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stainless steel 100 mm long Butt hinges, medium weight, cold rolled fixed with screws/ welding to wooded/steel frames or chowkats complete all as specified and as directed by Engineer-in- charge.
Supply and fixing extruded aluminium anodised type B-21, 100mm long butt hinges with galvanised mild steel screws complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 100 mm long aluminium anodised, barrel tower bolts extruded section complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 125 mm long aluminium anodised handles, cast type, complete all as specified and as directed by Engineer-in-charge.
Supply & fixing continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flap (when open) 30mm complete all as specified and as directed by Engineer-in- charge.
Material and Labour for preparing new or previously untreated steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and as directed by Engineer-in- charge.
Material and Labour for any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and Labour 25mm thick cement concrete type B0 (1:2:4) (12.5mm graded stone aggregate) as in floors, sub-floors etc. and finishing surafce of concrete topping as even & fair or even & rough to receive the topping layer complete all as specified and as directed by Engineer-in- charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in vertical surface set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for cutting chasses in brick wall girth exceeding 10cm but not exceeding 20cm wide for concealed water tubing etc. and making good in cement mortar 1:3 or PCC 1:2:4 Type B-1 using 20mm graded stone aggregates complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Material and Labour for machine cut kota stone slab 18-22 mm thick as approved by GE as in flooring, laid over and including 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry @ 3 Kg/ Sqm mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed by Engineer-in- charge.
Material and Labour for machine cut kota stone slab 18-22 mm thick as approved by GE as in vertical surfaces, laid over and including 10 mm thick rendering in CM 1:4 laid and jointed with grey cement slurry @ 3 Kg/ Sqm mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed by Engineer-in- charge.
Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge.The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.
Demolition of cement concrete of any discription and in any position, including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for formwork to soffits and sides of suspended slabs such as roof slab, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in- charge.
Material and Labour Brick work with sub class ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in- charge.
Material and labour Brickwork with sub class 'B' old size burnt clay bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material & Labour for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for cement concrete (1:5:10), type E-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete and sub base in floors etc complete all as specified and as directed by Engineer-in-charge.
Material and Lablour for Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under :- (a) Material and Labour for rendering 10 mm thick in cement mortar 1:3 using coarse sand as approved by GE mixed with integral water proofing compound as per manufacturer's instruction trowel even and smooth with steel trowel on sunken surfaces. (b) Applying first coat of chemical pidifin 2K on cleared RCC surfaces @ 0.86 Kg/Sqm (minimum) as recommened by manufacturer. (c) Provide a layer glass fiber mesh of size 2.25mm x 2.25mm (45 GSM) over first coat of chemical pidifin 2K as per manufacturers recommendations. (d) Applying second coat of chemical Pidifin 2K @ 0.86 Kg/Sqm (minimum) layer glass fiber mesh of size 2.25mm x 2.25mm (45 GSM) as recommened by manufacturer. Note : WPC shall be measured and paid separately as supply only and labour component is included in this item. Water testing minimum 72 hours after complition of treatment.
Supply only integral water proofing compound complete all as specified and as directed by Engineer-in-charge.
Material and labour for applying a coat of cold bituminous primer @0.5 Ltr/Sqm over RCC/plastered roof surface and flashing etc. followed by APP modified five layer polymeric membrane minimum 3mm thick, minimum weight 3.00 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm) , laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical suface if required complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and Labour for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces of walls and finishing the surface even & fair faces without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and Labour for rendering 15 mm thick in cement mortar (1:6) on other than fair face of brick work or concrete surfaces of walls and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for rendering 5 mm thick in cement mortar in (1:3) on ceiling and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for applying three coats of white wash on newly plastered surfaces including preparation of surfaces on wall complete all as specified and as directed by Engineer-in-charge.
Material and labour three coats of white wash on newly plastered surfaces including preparation of surfaces on ceiling complete all as specified and as directed by Engineer-in-charge.
Material and Labour for preparation of old plastered surfaces and applying one coat of white wash on ceiling, complete all as specified and as directed by Engineer-in- charge.
Material and Labour for preparing old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surface complete all as specified and as directed by Engineer-in- charge.
Material and Labour for preparing old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Complete removal of existing treatment on Old internal wall surface of any description, preparation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology, complete all as specified and applying the following :- (a) Material and Labour for wall care putty 2.00mm thick in two layers (Each layer 1.00mm thick) on wall surface and smoothening the surface with sand papers/Mechanised sanding etc. prepartory to paint as directed by Engineer-in-charge complete all as specified. (b) Material and Labour two coats of interior acrylic emulsion of approved tint over a coat of alkali resistant priming paint on old prepared surface by using Airless spray/Roller complete all as directed by Engineer-in-charge. Note :- Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.
Material and Labour for Preparation of new plastered internal wall surafce complete all as specified and applying the following :- (a) Material and Labour for wall care putty 2.00mm thick in two layers (Each layer 1.00mm thick) on wall surface and smoothening the surface with sand papers/Mechanised sanding etc. prepartory to paint as directed by Engineer-in-charge complete all as specified. (b) Material and Labour two coats of interior acrylic emulsion over a coat of alkali resistant priming paint by using Airless spray/Roller complete all as directed by Engineer-in-charge. Note :- Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.
Material and Labour for Preparation of new external plastered wall surafce complete all as specified and applying the following :- (a) Material and Labour for wall care putty 2.00mm thick in two layers (Each layer 1.00mm thick) on wall surface and smoothening the surface with sand papers/Mechanised sanding etc. prepartory to paint as directed by Engineer-in-charge complete all as specified.etc precatary to paint as directed complete all as specified. (b) Material and Labour two coats of exterior acrylic emulsion paint by using Airless spray/Roller over and including a coat of acrylic emulsion external primer complete all as specified.
Material and Labour for Complete removal of existing treatment including filling depression of scraped surface with two coats of 3.00mm thick wall putty (1.5mm thick each coat ) on old external wall surface of any description, preparation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology, complete all as specified and applying the following :- (a) Material and Labour for two coat of exterior acrylic emulsion Paint by using Airless spray/Roller over and including a coat of acrylic emulsion external primer complete all as directed by Engineer-in- charge.
Material and Labour for machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including 25 mm thick layer of sand cushioning complete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account.
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc Laid dry or bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
Material and labour Marble work (Udaipur Green slab ) not less than 18mm-20mm thick (table rubbed and polished) as in cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) , using marble dust with admixture of pigment to match with marble shade including round the edges of marble over and including 15 mm thick screed in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. Note:- Sample of marble slab shall be approved by GE before procurement.
Dismantling of brick tiles or terracing tiles, single layer on roof and disposal of retrieved unserviceable material upto a distance not exceeding 500 mtr away complete all as specified and as directed by Engineer-in- charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part thereof) disposal off rubbish upto a distance not exceeding 500 mtr where directed complete all as specified and as directed by Engineer-in- charge.
Wire brushing and cleaning top surface of roof slabs etc including washing the roof surface with water and making the surafce free form mud etc complete all as specified and as directed by Engineer-in- charge.
Material and Labour rendering / screed 10mm thick (average thickness) on roof surface including flashing and junctions of parapets etc finished even and fair in Cement Mortar 1:4 with and including mixing with Integral Water Proof Compound as per manufacturer's instructions ,with and including brushing cement slurry @ 1.20 Kg/Sqm all as specified Note:(Integral Water Proof Compound to be measured and paid separately as supply only)
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement concrete 1:2:4 Type B-1 using 20mm graded stone aggregates and finished the surface in cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour Ceramic roof tile, white colour 9-10mm thick, minimum size 300mm x 300mm conforming to solar reflective index (SRI) valuue minimum of 90 ° F laid over with and including bedded on 15mm thick screed in cement mortar (1:4) and set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white cement complete all as specified and directed by Engineer-in-charge.
Material and Labour for making benching PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate using water proofing compound as per manufacturer's instruction along the side wall adjoining to roof in concave shape complete all as specified and as directed by Engineer-in- charge Note:- WPC shall be measured and paid separately as supply only.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening including easing and adjusting including renewal of unserviceable screws etc. complete all as specified and as directed by Engineer-in- charge.
Taking down rain water pipe any size including all fittings complete all as specified and as directed by Engineer-in- charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete)of any dia set in cement laid in trenches incl all fittings & accessorises complete all as specified and as directed by Engineer-in- charge.
Excavation in trenches not exc 1.5 meter wide and not exc 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables etc not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge.
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soil complete all as specified and as directed by Engineer-in- charge.
Removal of surplus excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed by Engineer-in- charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in bed of drain pipe of size upto 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for as specified dia of pipe 150mm and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Engineer-in- charge..
Taking down carefully copper /aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem , sheet switches, ceiling rose, pendent holder sockets, regulator except concealed conduit and sunken boxes etc. complete all as specified and directed by Engineer-in-charge.The weight of aluminium scrap and copper scrap for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.
Material and Labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 2.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through existing concealed conduit surface on wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing switches, socket outlets, fan regulators, etc. including blanking plates & all other fixing accessories and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge for the following items described under serial item nos. 139, 140.00,141.00,142.00 & 143.00 of BoQ. NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches,sockets and regulators shall be measured and paid seperately under respective items of Schedule'A' BoQ.
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc.
One light point controlled by two- two way switch.
One Socket outlet three pin, 6 Amp, on the same board
One Socket outlet three pin, 6 Amp, independent board
One socket outlet three pin, 5/15 Amp, independent board
Material and Labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 1.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through existing concealed conduit surface on wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing for the One Bell/Buzzer point controlled by one push button including blanking plates & all other fixing accessories and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches,sockets and regulators shall be measured and paid seperately under respective items of Schedule'A' BoQ.
Supply & Fixing modular type Switch single pole, one way, 6 Amp, one module, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing modular type Switch single pole one way, 16 Amp, one module, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing modular type Switch single pole, two way, 6 Amp, one module, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing modular type Bell push switch single pole one way, 6 Amp, one module, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing modular type Socket outlet , multipurpose, 3 pin, single pole one way, 6 Amp, two module, shutter type complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing modular type Socket outlet multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter type complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing Fan regulator-120W, modular type, 5 step, high speed, two module complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing call bell ding dong type AC 230 V complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing Wall mounted extruded Aluminium & polycarbonate integrated LED batten fitting and fixture with and including 1.2 m long 20watt tube rod , 3000/6500K,efficacy not less than 90 lumen/watt, extruded , PC diffusor and integrated inbuilt driver complete as per manufacturer's instructions including making connection complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing Wall mounted LED batten fitting 10 watt, environment friendly,energy efficient ,6500K, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate with and including 2.00 feet Long LED Tube light complete all as per manufacturer's instructions including making connection complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing LED security light fitting 35 Watt 230V , AC, outdoor type , with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with and including bracket made out with 40mm bore Galvanised Iron light grade pipe 1.2 mtr length bent to shape , fixing with 02 Nos. MS clamps made out of MS flat iron size 25mm x 3 mm with suitable bolt and nuts and painting with two coats of synthetic enamil paint over a coat of zinc chromate primer complete with making connection complete all as specified and directed
Supply and Fixing lamp holder PVC/ polycarbonate type with back plate suitable for batten fitting with LED bulb 5 watt B22 base complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Sub main wiring with two single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including cuttting, chasing and grouting including non metallic rigid PVC conduit medium quality of size 20 mm dia conforming to 3537 Part-I ISI marked including all fitting such as Tee, Elbow, bend etc drawn in and including one single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade as in continuous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. .Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including non metallic rigid PVC conduit of size 20 mm dia shall be measured as one length.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, double door, powder coated DB SPN 12 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, double door, powder coated TPN 4 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 20 to32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge
Supply & Fixing in replacement RCBO for EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 415 V 63A AC type 10kA Four pole 30mA ISI marked complete all as specified and as directed by Engineer-in-charge
Material & Labour in replacement for earthing with galvanized steel plate electrode 600MM x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mesH for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using 20MM graded stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion . Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be inlcuded in quoted rate:- (i) CA No. (ii) Date of installation after initial testing & Value of earth resistance in Ohm (iii) Date of last testing (iv) Value of earth resistance in Ohm in last test
Taking down Ceiling fan , sealing cable end , dismantling blades and removing and deposting the same in E/M store yard of concerned GE complete all as specified and directed by Engr-in- Charge.
Hanging only ceiling fan, blades and connecting up with and including suitable size of copper cable from ceiling rose or connector to ceiling fan retrived from serial item no. 166.00 here -in before complete all as specified and directed by Engr-in- Charge.
Dismentaling & taking down of existing energey meter & refixing the same complete all as specified and as directed by Engineer-in- charge.
Labour only for dismantling & taking down of existing Geyser and deposit to E/M store yard safely & refixing the same (after carrying out repair work/rewiring in Accn), complete all as specified and as directed by Engineer-in- charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ.
V K CONTRACTOR
M/s MITTAL CONSTRUCTIONS
Ajay Enterprises
SHARDA ENTERPRIES
yogesh kumar contractor
M/S VERMA BUILDERS & DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .