Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC Due to lowest | |
| 2 | L2₹35.8 L+₹99,160.50 (2.85%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.9 L+₹2.1 L (6.02%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.5 L+₹2.7 L (7.66%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.9 L+₹3.1 L (8.84%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/s badrinath Traders L5 | NAQLI LAL SHARMA AND ARUN SHARMA L2 | V r traders L3 | Raman Electric Trading Co L7 | Sharma Electrical and Engineering Works L6 | trinity construction L1 | SUBHASH CHAND CONTRACTOR L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in ARC main campus/TX area/Airwing area and connected road light by checking connection, serviceability of fittings, SMC boxes, MCB, thimbles or any other minor fault complete all as specified and directed.
Note:- (a) Arrangement of Ladder shall be done by contractor.
(b) Arrangement of hydra or any other T&P, Grese for attending complaints of Hanger light shall be done by contractor.
(c) Complaints shall be rectified with in 24 Hours.
(d) Weekly inspection of all security lights/street lights of area under ARC shall be carried out and report shall be submitted to Engr-in-chage with out any delay. | 250 | Each Job | 200 ₹50,000 | 100 ₹25,000 | 99 ₹24,750 | 150 ₹37,500 | 80 ₹20,000 Lowest | 80 ₹20,000 Lowest | 220 ₹55,000 |
| 2.00 | S & F LED type street light 35 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. | 5 | Each | 1,200 ₹6,000 Lowest | 1,200 ₹6,000 Lowest | 1,599 ₹7,995 | 2,000 ₹10,000 | 2,500 ₹12,500 | 2,500 ₹12,500 | 2,500 ₹12,500 |
| 3.00 | S & F LED type street light 60 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 5 | Each | 2,000 ₹10,000 | 1,600 ₹8,000 Lowest | 1,999 ₹9,995 | 4,000 ₹20,000 | 3,600 ₹18,000 | 4,500 ₹22,500 | 2,500 ₹12,500 |
| 4.00 | S & F LED type street light 90 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 5 | Each | 3,000 ₹15,000 | 2,200 ₹11,000 Lowest | 2,499 ₹12,495 | 4,000 ₹20,000 | 4,200 ₹21,000 | 6,500 ₹32,500 | 4,000 ₹20,000 |
| 5.00 | S & F LED high bay light of 120 W IP66&IK08 protected highbay with PDC housing & toughened glass suitable for ceiling(surface/suspended) mount including all connection complete all as specified and as directed. | 10 | Each | 3,900 ₹39,000 Lowest | 5,000 ₹50,000 | 4,499 ₹44,990 | 5,600 ₹56,000 | 11,000 ₹1,10,000 | 12,000 ₹1,20,000 | 7,000 ₹70,000 |
| 6.00 | S & F LED type flood light 100 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. | 5 | Each | 2,000 ₹10,000 | 1,600 ₹8,000 Lowest | 3,499 ₹17,495 | 3,800 ₹19,000 | 5,500 ₹27,500 | 8,000 ₹40,000 | 3,000 ₹15,000 |
| 7.00 | S & F LED type flood light 150 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. | 10 | Each | 4,000 ₹40,000 | 2,600 ₹26,000 Lowest | 3,499 ₹34,990 | 4,700 ₹47,000 | 6,000 ₹60,000 | 8,000 ₹80,000 | 4,000 ₹40,000 |
| 8.00 | S & F LED type flood light 250 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. | 15 | Each | 7,000 ₹1,05,000 | 4,000 ₹60,000 Lowest | 4,999 ₹74,985 | 6,500 ₹97,500 | 8,000 ₹1,20,000 | 8,000 ₹1,20,000 | 8,000 ₹1,20,000 |
| 9.00 | S & F post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 10 | Each | 5,000 ₹50,000 | 2,900 ₹29,000 Lowest | 4,399 ₹43,990 | 5,100 ₹51,000 | 6,500 ₹65,000 | 6,500 ₹65,000 | 9,000 ₹90,000 |
| 10.00 | S & F LED Bollard 10 watt 230 volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
Note- Earth work and PCC shall be included in quoted rate. | 10 | Each | 2,500 ₹25,000 | 2,400 ₹24,000 Lowest | 4,299 ₹42,990 | 3,500 ₹35,000 | 4,200 ₹42,000 | 3,500 ₹35,000 | 8,000 ₹80,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jun 2025, 6:00 pmClosed
SHRI PRASANTA KACHARI GE (AF) SARSAWA
SHRI PRASANTA KACHARI GE (AF) SARSAWA
REPAIR/ MAINT OF EXTERNAL WATER SUPPLY SYSTEM, REPAIR/MAINT OF DG SET, SECURITY LIGHTS, FIRE ALARM SYSTEM, VOLTAGE STABILIZERS, LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT ARC AND AIRWING AREA SARSAWA UNDER GE (AF) SARSAWA
2025_MES_709449_1
8125/SAR-T-05/2025-26
Open Tender
Civil Works
Item Rate
330 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) SARSAWA
₹90,000
Yes
14 Aug 2025
21 May 2025
25 Jun 2025
21 May 2025
18 Jun 2025
4 Jun 2025
21 May 2025 - 4 Jun 2025
Amount
M & L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in ARC main campus/TX area/Airwing area and connected road light by checking connection, serviceability of fittings, SMC boxes, MCB, thimbles or any other minor fault complete all as specified and directed. Note:- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra or any other T&P, Grese for attending complaints of Hanger light shall be done by contractor. (c) Complaints shall be rectified with in 24 Hours. (d) Weekly inspection of all security lights/street lights of area under ARC shall be carried out and report shall be submitted to Engr-in-chage with out any delay.
S & F LED type street light 35 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
S & F LED type street light 60 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
S & F LED type street light 90 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
S & F LED high bay light of 120 W IP66&IK08 protected highbay with PDC housing & toughened glass suitable for ceiling(surface/suspended) mount including all connection complete all as specified and as directed.
S & F LED type flood light 100 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
S & F LED type flood light 150 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
S & F LED type flood light 250 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
S & F post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
S & F LED Bollard 10 watt 230 volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. Note- Earth work and PCC shall be included in quoted rate.
S & F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator with MS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works complete all as specified and directed.
S & F in rep/replacement of cable PVC insulated unarmored for connection 2.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in heavy duty rigid PVC conduit pipes complete all as specified and directed.
M & L for scrapping of surface of steel tubular poles of any size with emery paper and painting of poles with one coat of primer and two coats of aluminium paint of approved make incl writing pole nos on white backgrounds with black paint, complete all as specified and directed.
S & F in replacement of existing unserviceable driver circuit with new one of any make or any model on existing LED street light luninatrie of wattage 45 to 120W complete all as specified and directed.
All as per Item No 14.00 here-in-above but luninatrie of wattage 60 to 180W complete all as specified and directed.
S & F in replacement of existing unserviceable surge protector with new one of any make or any model on existing LED street/Flood light luninatrie of wattage 45 to 120W complete all as specified and directed.
M & L for street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed .
S & F of timer switch for security light duly steel enclosed with locking arrangement fixed to wall/pole / existing panel by means of clamp.nut,bolt washers or by welding including following items-(a) MCCB 63 A 16 KA 4 Pole-01 Nos,(b) MCB SPN 16-40 Amp - 01 Nos, (c) Power Contactor ML3 , 3 Pole- 01 No, (d) Time switch analog dial type - 01 Nos, (e) Bypass arrangement for testing/repair of light complete all as specified and directed.
S & F LED aviation light 10 watt duly enclosed in die cast aluminium casting with Red polycarbonate dome for better illumination, Integral driver, Supper flux 5mm 302 Nos LEDs incorporated with Ingress Protection : IP65, Protection against short-circuit, Protection against surge, wide operating input voltage range 100 – 270VAC, burning 50,000 Hrs complete all as specified and directed.
M & L for inspection , servicing and repair of DG sets with B check by authorised service engineers of manufactureres of the following capacities including minor repairs and replacement of worn out spares such as fuel filter, hose pipes, injector nozzles, cut out, electrical wiring, self starter, dynamo / alternator and tightening of nut bolts, washers, tappet adjustments, cleaning of head assembly including and de-carbonising, inlet and exhaust valves, grinding of valve seats, changing of lubricating oil, etc; complete including testing on load complete all as specified and directed. 40 KVA capacity Notes:(i) Spares incl E/Oil required shall be measured and paid seperately under respective items of Schedule. (ii) The POL required for for carrying out test after repairs will be issued by the department. (iii) Testing of DG sets up to working load will be carried out after carrying out repairs to the entire satisfaction of the Engr-In- Charge. (iv) The rate quoted includes for all essential materials which are not otherwise specified in this schedule but are required to ensure smooth functioning of the DG Sets. (v) All T&P, manpower and transport required to carry out the work at site including loading , un-loading etc will be provided by the contractor. Cost of the same is deemed to be included in the quoted rates. (vi) All additional spares oil filter, air cleaner, oil pump repair kit, V- belt, Oil pipes, fuel pipe, water pump, head gasket kit,etc as required will measured and paid seperately. (vii) After servicing Contractor has to attend and rectify any complaint related to perticuler DG set within 24 Hrs without any cost to department till the duration of contract. Amount of Rs 500 per day will be recovered for any delay attending complaints.(viii) servicing shall be carried out within 15 days from commencement of the work.
All as per Item No 20.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 20.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 20.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
S & F in replacement of oil pipe (Copper flexible tube) with check nuts for DG sets of any make / capacity complete all as specified and as directed.
Supply and replace 'V' belt as per sample for DG sets of following capacity complete all as specified and directed. 40 KVA capacity
All as per Item No 25.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 25.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 25.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
S & F in replacement of fuel flexible pipe, FIP to Filter, heavy duty with check nuts and benjo bolts, for DG sets of capacity upto 250 KVA complete all as specified and directed.
Supply and replace air cleaner filter assembly complete suitable for DG set of of following capicity complete all as specified and directed. 40 KVA capacity
All as per Item No 30.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 30.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 30.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
S & F in repair oil pressure gauge suitable for DG set upto 250 KVA complete all as specified and as directed.
S & F in repair temperature gauge suitable for DG set upto 250 KVA complete all as specified and as directed.
S & F in repair lube oil filter for DG sets of any make / capacity complete all as specified and as directed.
S & F in repair fuel filter for DG sets of any make / capacity complete all as specified and directed.
S & F in repair ignition switch, 12 V with keys complete all as specified and as directed.
Dismantling and taking down radiator assembly from engine of DG Set for repairs including de-scaling, bracing of inner tubes and body as required to plug leakages, repairs to radiator frame and tank including cutting and removing deteriorated inner tubes, chamber, frame etc. and re-constructing the same with same material in original size and shape, cleaning / straightening of fins and re fixing after repairs including replacement of worn out nut bolts, washers, aluminium water elbow, radiator cap, radiator beds etc; and pressure testing for leakage of follwing capacity complete all as specified and directed. 40 KVA capacity
All as per Item No 39.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 39.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 39.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
S & F in replacement, radiator assembly complete including all accessories such as radiator core comprising copper tubes, fins, upper and lower tanks, radiator frame, inlet and outlet pipes, radiator cap etc,complete all as directed for the following capacities. 40 KVA DG set .
All as per Item No 43.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 43.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 43.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
Supply and replace of maintanance free unserviceable battery 12 V, 150 AH with initial charging and testing complete all as specified and directed.
All as per Item No 47.00 here-in-above for size of battery 12 V, 90 AH complete all as specified and directed.
M & L for cleaning of fuel tank of DG sets of capacity 40 KVA emptying the fuel carefully and removing all sedimented particles including scales using wire brushes and kerosene including replacement of worn out transparent fuel level indicating tube including necessary fixing arrangements and marking fuel levels on the tank using white synthetic enamel paint complete all as specified and directed.
All as per Item No 49.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 49.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 49.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
M & L for replacement of battery terminal of brass suitable for 12V, 90 AH to 150 AH battery complete all as specified and directed.
M & L for replacement of battery lead, copper conductor, single core, 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends of lengths as per site requirements complete all as specified and directed.
S & F in repair rubber hose pipe kit complete for radiator suitable for DG Sets of following capacity complete all as specified and directed. 40 KVA capacity
All as per Item No 55.00 here-in-above but for capacity of 160 KVA complete all as specified and directed.
All as per Item No 55.00 here-in-above but for capacity of 200 KVA complete all as specified and directed.
All as per Item No 55.00 here-in-above but for capacity of 250 KVA complete all as specified and directed.
Supply and fillling coolant suitable for DG set complete all as specified and directed.
Supply in replacement, Engine oil, multi grade 20 W 40 or equivalent grade complete all as specified and directed.
Supply and Topup of distilled water in Battery of any size complete all as specified and directed.
M & L for replacement of AVR Unit of 250 KVA DG Set complete all as specified and directed by Engr-In-Charge.
Maintenance / repairs to AMF panels, by skilled technician and replacement of unserviceable spares as specified below for capacities of 40 to 250 KVA DG set including replacement of controle wiring with FRLS copper conductor cables with appropriate gauge and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site.
Supply only electronic timer any type for 0 to 10 Sec (on Delay) complete all as specified and directed.
Supply only electronic timer any type for 0 to 60 Sec (off Delay) complete all as specified and directed.
Supply only Power contactor MNX 35, 3-pole device with a rated operational current of 32A, 415V AC, designed for motor feeder and control system 240V AC complete all as specified and directed.
All as per Item No 66.00 here-in-above but Power contactor MNX 70 complete all as specified and directed.
All as per Item No 66.00 here-in-above but Power contactor MNX 110 complete all as specified and directed.
Supply only starting relay with sequence timer and master timer complete all as specified and directed.
Supply only under voltage relay complete all as specified and directed.
Supply only over voltage relay complete all as specified and directed.
M & L for repair/replacement of battery charger for AMF panel with existing capacity complete complete all as specified and directed by Engr-In-Charge.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 25 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 35 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 50 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 70 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 95 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 120 Sqmm X 3.5 core complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of cable 240 Sqmm X 3.5 core complete all as specified and directed.
S & F in repair GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables complete all as specified and directed.
All as per Item No 81.00 here-in-above but of size 80 mm bore complete all as specified and directed.
S & F in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and directed.
All as per Item No 83.00 here-in-above but size of cable of size 70 to 150 sq mm complete all as specified and directed.
All as per Item No 83.00 here-in-above but size of cable of size 185 to 400 sq mm complete all as specified and directed.
S & F ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 250 Amps in SS Enclosure and conforming to IS/IEC : 60947-1 & 3 complete all as specified and directed.
All as per Item No 86.00 here-in-above but for 4 pole 415 volt 50 Hz 200 Amps complete all as specified and directed.
All as per Item No 86.00 here-in-above but for 4 pole 415 volt 50 Hz 125 Amps complete all as specified and directed.
All as per Item No 86.00 here-in-above but for 4 pole 415 volt 50 Hz 100 Amps complete all as specified and directed.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix complete all as specified and directed.
S & F in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed. Note: (a) Make of MCCB shall be all as per the make in the existing planel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder neccssary alteration required to fix the same at no extra cost shall be done by the bidder. (b) Type of MCCB whether with operating knob or handle type shall be procured as per site requirement.
All as per Item No 91.00 here-in-above but MCCB TP 160 Amps, 36 KA with adjustable thermal setting ( 80 to 100 %) complete all as specified ans directed.
All as per Item No 91.00 here-in-above but MCCB TP 250 Amps, 36KA complete all as specified and directed.
All as per Item No 91.00 here-in-above but MCCB TP 125 Amps, 36KA complete all as specified and directed.
All as per Item No 91.00 here-in-above but for 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No 91.00 here-in-above but for 250 Amps complete all as specified and directed.
All as per Item No 91.00 here-in-above but for 400 Amps complete all as specified and directed.
Supply, installation and commissioning of MF Heavy Duty long life TRIPODE Earthing set to get guaranteed permanent stable resistance value of set less 1 ohm in all weather and any type of soil condition consisting of High Quality Hot Dipped Galvanized Iron (HQHDGI) as per Model No 61180HQHD of make Om Electrotech india of pit depth 32500mm, electrode depth 3100mm, pit dia 300mm to 400 mm, with electrode dia of 76mm. High Quality Hot Dipped Galvanized Iron (HQHDGI) Electrode should be CPRI approved for high magnitude fault current and should be able to stand High voltage Earthing Test (HVET) at site , filled with hygroscopic non - hazardous superconductive pure graphite and Sulphur based homogenous semi paste form mixture of different conductive compounds which have very long life and moisture holding capacity. Pit should be filled with NABL approved LAB tested superconductive paste of hygroscopic non - hazardous superconductive pure graphite, Sulphur, aluminum, zinc compounds and natural minerals added in sufficient quantity to hold the moisture. Individual sets should be interconnected with GI strip of size 25 x 3mm to make TRIPODE Set along with protection pipe. Tripode set and test point shall be interconnected with same strip along with protection pipe. All pits should be covered with suitable Poly plastic / FRP / MS pit cover. Installation and commissioning should be done by OEM for guaranteed resistance value of less than 1 ohm and should be able to do High voltage Earthing Test (HVET) at site. Each Electrode should bear manufacturer Srl No to check genuinity of material complete all as specified and directed. Note : 1. Quoted rate are inclusive of earth work, GI strip for interconnection with protection pipe. 2. Earthing shall be tested after completion of work by contractor in presence of Engr-in-Charge and proper record shall be maintained duly signed by all concerned. On testing if the desired earth resistance of less than 1.0 Ohm is not obtained the earthing will be redone at no extra cost to Govt. 3. Test point shall be deemed to be included in the quoted rates.
M & L for preparation of old steel painted surfaces of LT panels of any type and size by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with super enameled paint with colour of users choice approved by Dept. and writing the distribution area/location with white paint as directed to transformer indoor/outdoor installed at various different locations complete all as specified and directed.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
Supply, installation, Testing and Commissioning of 7M GI Octagonal pole single section with bottom dia 135mm, top dia 70mm having sheet thickness 3mm. The door height cut-out should not be more than 500mm with door elevation 500mm. The size of the reinforced rod should be 30x4mm. Size of the base plate should be 220SQ with thickness of base plate 16mm. PCD for the holes should be 225 with foundation bolt dia M20, length of the foundation bolt 700mm with four foundation bolts. The Arm should be 1M length single arm with 15-degree Arm bracket. The total height of the pole should be 9000 mm above the finished Groundlevel including PCC foundation, J Bolt, nuts and washers as per the drawing of Manufacturer complete including taking out the old unserviceable RCC pole complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, laying of pipe lines, poles & stay etc complete all as specified and directed.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed.
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed.
M & L for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed.
M & L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation of pole or similar works complete all as specified and directed.
M & L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for fixing of pole complete all as specified and directed.
M & L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for copings of poles/stay/panels complete all as specified and directed.
Disconecting the LT incoming and outgoing main cables of any size ,strip opening of the 120 KVA voltage stablizer , draining out the oil into a cleaned container (container shall be arranaged by the contractor ). Lifting up dimmer and transformer with help of tripoid and chain pulley etc (The T & P shall be arranged by contractor), checking of all the parts ,cleaning and servicing of the container,dimmer,transformers coil and allied parts including replacememnt of minor parts like nut bolts ,connecting wires ,rubber seals /packing etc . (The repair/ replacement of the major parts shall be measured and paid seperately ) and reassembling the volt stablizer complete (in reverse order.). Refilling oil after dehydration and filtration/cleaning by centrifuging machine including testing of samples before and after dehydrations and filtration complete, and reconeecting the incoming and outgoing cable connection, commisioning and testing of the volt stablizer on load complete all as specified and directed.
S & F in replacement of Electronic circuit card( P.C B) card with drive assembly for unbalanced type stablizer of 120 KVA complete all as specified and as directed.
S & F in replacement of Auto/manual switch for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of Push button switch for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of Micro switch for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of DPDT switch for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of Panel lamp for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of Potentiometer for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of Volt meter of Range 0 to 300V (Digital/analog) complete all as specified and directed.
S & F in replacement of Volt meter of Range 0 to 500V (Digital/analog) complete all as specified and directed
S & F in replacement of Ampere meter of Range 0 to 500 Amps with suitable size of C.T. (Digital/analog) for servo type voltage stablizer 120 KVA capacity complete all as specified and directed.
S & F in replacement of P.C.B. holder for servo type voltage stablizer of capacity 120 KVA complete all as specified and directed.
S & F in replacement of Trigger Transformerfor servo type voltage stablizer of capacity 120 KVA complete all as specified and directed.
S & F in replacement of Servo motor 10 K.G. torque for servo type voltage stablizer of capcity 120 KVA complete all as specified and directed.
S & F in replacement of R.C. net work for 10 K.G. motor for servo type voltage stablizer of capacity 120 KVA complete all as specified and directed.
S & F in replacement of Carbon Brush for servo type voltage stablizer of capacity 120 KVA complete all as specified and directed.
S & F in replacement of finger holding carbon brush for servo type voltage stablizer of capacity 120 KVA complete all as specified and directed.
Dehydration of 11 KV existing transformers oil minimum three cycles to achieve dielectric strength up to 60 KV in 2.5 mm gap electrode including toping up of oil if required at site complete all as specified and directed. Note: (i) Dehydration of transformer oil shall be carried out at site and contractor shall be taken the testing result before and after dehydration of oil and shown to the EIC at site and maintain necessary documents for record. (ii) Dehydration Machine with all T&P & Transformer oil testing machine for dehydration of Transformer oil and necessary transportation for the machines is arrange by contractor . (iii) Oil required for topping up the transformer stabilizer will be measured & paid separatly
Supply and topping up of new low viscosity transformer oil from sealed drums confirming to IS 335-1993 Part-II after testing the correct dielectric strength up to 60 KV at 2.5 mm gap duly de-hydrated complete all as specified and directed.
Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire alarm system complete & 100 % servicing of fire alarm panel, smoke/heat detector/response indicator, Hooters, Manual call points complete including checking, cleaning of fire detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of battaries, specific gravity of electrolyte, the alarm function control panel and indicating eqpts be checked by the operation of trigger device in each zone as described the system installed Airwing area, addressable type fire alarm system complete all as specified and directed.
Supply,installation,testing and commissioning of Fire Alarm control panel complying with BS EN 54 single Loop panel of capacity from 99 detectors & 99 Modules & upto 200 detectors and modules (per each loop) complete all as specified and directed.
Supply, installation, testing and commissioning of Control Module complete all as specified and directed.
Supply,installation,testing and commissioning of detectors complying with and type certified to EN - 45 Addressable type muiltisensor detectors with heat and smoke with combination complete all as specified and directed.
Supply, installation, testing and commissioning of Addressable Manual Call Point re-settable type complete all as specified and directed.
Supply, installation, testing and commissioning of Addressable electronic Sounder cum Strobe complete all as specified and directed.
S & F of Remote response indicators complete all as specified and directed.
Supply, installation, testing and commissioning of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and directed.
Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size 15mm to 20mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc complete all as specified and directed. NOTE:- (i) The cost of GI pipe upto 0.3 mtr and GI fittings shall be included in the quoted rated. (ii) Excavation and earth work required shall be measured and paid separately. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (vi) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (v) Complaints given to contractor shall be rectified within 24 hrs. (vi) A penality of Rs 500/- per complaint will be charged for not attending the complaints and complete all as specified and directed.d within 24 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required.
All as per Item No 138.00 here-in-above but for 25mm bore complete all as specified and directed.
All as per Item No 138.00 here-in-above but for 40mm bore complete all as specified and directed.
All as per Item No 138.00 here-in-above but for 50mm bore complete all as specified and directed.
All as per Item No 138.00 here-in-above but for 80mm bore complete all as specified and directed.
Taking up or down old unsv steel water tubing of size 15mm bore from trenches or walls etc. complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid separately.
All as per Item No 143.00 here-in-above but size of Pipe 20mm bore complete all as specified and directed.
All as per Item No 143.00 here-in-above but size of Pipe 25mm bore complete all as specified and directed.
All as per Item No 143.00 here-in-above but size of Pipe 40mm bore complete all as specified and directed.
All as per Item No 143.00 here-in-above but size of Pipe 50mm bore complete all as specified and directed.
All as per Item No 143.00 here-in-above but size of Pipe 80mm bore complete all as specified and directed.
S & F in replacement gun metal glove or gate valve heavy duty of size 15 mm bore ISI marked class-1 with iron wheel head, screwed both ends for iron pipe of bore complete all as specified and directed.
All as per Item No 149.00 here-in-above but size of Pipe of 20mm bore complete all as specified and directed.
All as per Item No 149.00 here-in-above but size of Pipe of 25mm bore complete all as specified and directed.
All as per Item No 149.00 here-in-above but size of Pipe of 40mm bore complete all as specified and directed.
All as per Item No 149.00 here-in-above but size of Pipe of 50mm bore complete all as specified and directed.
S & F in replacement cast iron sluice valves ISI marked with hand wheel suitable for pipe of 200 mm bore, both ends flanged rating PN-1.0 with SS spindle including jointing with New MS nuts and bolts, washers and gasket etc complete all as specified and directed.
All as per Item No 154.00 here-in-above but for pipe of size 150 mm bore complete all as specified and directed.
All as per Item No 154.00 here-in-above but for pipe of size 100 mm bore complete all as specified and directed.
M & L for construction of masonry pits of size 60 x 60 x 60cm (internal size) for sluice valves with sub Class 'B' bricks straight or curved or plan exc 6 mtr mean radius built in cement mortar (1:6) PCC (1:3:6) in foundation, 15 mm thick plaster in cement mortar (1:4) on internal faces of walls, 40 mm thick, PCC (1:2:4) in floors including valve pit cover made out of MS sheet 2 mm thick with angle iron 40x40x6 mm frame with fixing hinges, locking arrangement hold fastand handle etc duly painted with two coats of synthtic enamel paint over a coat of red oxide primer including necessary excavation & earth work inclding breaking of existing broken/ damaged valve pit the contractor can utilize retrived serviceable bricks complete all as specified and directed.
All as per Item No 157.00 here-in-above for of Size 90 x 90 x 90cm complete all as specified and directed.
All as per Item No 157.00 here-in-above for of Size 120 x 120 x 90cm complete all as specified and directed.
S & F in replacement of FRP hypo-chlorine powder granules solution preparartion cum setting tank capacity 100 Ltrs with lid, port hole, inlet/outlet/drain connection level gauge etc and fitted with 1 phase 0.5HP motor and agitator rod with wiring complete all as specified and directed.
S & F in replacement of Decrin Dosing Pump, Pump Tube And White Suction 1 Decrin Dosing Pump, High Pressure Single Head Gear Motored adjustable Dosing Pump with all accessories with Pump Tube, injection check valve,foot valve, strainer etc - 02 Set spare, complete all as specified and directed. Make: Declibac Technologies Private Limited/ RAMCO
Lifting / taking out the defective submersible pump motor set of any capacity and description / make, any depth from bore well by lifting tolls , chain pulley etc all as required carefully, by disconnecting / dismantling all electric connections, column pipes of size 100 mm etc and transporting the defective pump motor set to workshop, lowering the same /repaired/ new serviceable submersible pump or motor set to the existing location including replacing the rubber packing/ GI nut bolts of the column pipes etc of suitable size where ever required complete all as specified and as directed by Engr-in-charge.
M & L for rewinding of monoblock motor 3 Hp complete all as specified and as directed.
M & L for repair of monoblock pump 03 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of submersible motor of capacity 5 Hp complete all as specified and directed.
M & L for repair of submersible pump 05 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of submersible motor of capacity 15 Hp complete all as specified and directed.
M & L for repair of submersible pump 15 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of submersible motor of capacity 10 Hp complete all as specified and directed.
M & L for repair of submersible pump 10 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of submersible motor of capacity 20 Hp complete all as specified and directed.
M & L for repair of submersible pump 20 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of submersible motor of capacity 25 Hp complete all as specified and directed.
M & L for repair of submersible pump 25 Hp including seals, bush, bearings impellers etc complete all as specified and as directed.
M & L for rewinding of sewage motor 12.5 Hp complete all as specified and directed.
M & L for repair of sewage pump 12.5 Hp including seals, bush, bearings impellers etc complete all as specified and directed.
Collection of water samples (with and without chlorination) from Pump House ARC camp bore wells/sumps in sterilized bottles all as per the standard instructions and guidelines of the Chief Water Analyst of Department of water and Sewage examinations from any NABL approved LAB, transporting the samples safely and getting the same tested for chemical and bactyeriological tests, with and without chlorination test from the same Institute and report submitted to this office complete all as specified and directed. Note : The water samples (with and without chlorination) shall be counted as 01 set of sample.
All as per Item No 177.00 here-in-above but samples collected from Pump House Airwing Area complete all as specified and directed.
M & L for opening of pumpset from the installed position, dismantling of pump and motor assembly, complete servicing and cleaning of pumpset and refixing the same to the installed in position complete all as specified and directed.
M & L for Painting of entire OH tank after complete removal/scrapping of old surface, one coat wall primer and two coats of cement based paint complete all as specified and directed.
M & L for painting on MS/steel structures/member of OH tanks of height upto 25RM after complete removal of existing paint then apply one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed.
S & F in repair/replacement of submersible cable with size 4 Sqmm 3 core complete all as specified and directed.
M & L for comprehensive, preventive and periodical maintance of 01 No electrically operated RO of capacity 1000 LPH installed at ARC Campus to be maintained round the clock as described here-in after in reliable and efficient operating condition by regularly examine all the filters , pumps , tanks , membrane sand media , Antiscalent, UV and other electrical parts using techniques and expertise consultancy including replacement of spares parts as and when required to the entire satisfaction complete all as specified and directed.
Supply & laying, jointing galvanised steel water tubing, medium grade of pipe of 15mm bore, screwed joints with and including all required fittins as in trenches, floors, on wall etc complete all as specified and directed. Note: Excavation and earth work for fixing in old location already considered in items for taking out and for new locations if required the same shall be measured and paid separately.
All as per Item No 184.00 here-in-above but for pipe of size 20 mm bore complete all as specified and directed.
All as per Item No 184.00 here-in-above but for pipe of size 25 mm bore complete all as specified and directed.
All as per Item No 184.00 here-in-above but for pipe of size 40 mm bore complete all as specified and directed.
All as per Item No 184.00 here-in-above but for pipe of size 50 mm bore complete all as specified and directed.
All as per Item No 184.00 here-in-above but for pipe of size 80 mm bore complete all as specified and directed.
Supply only High Strength Calcium based granular disinfectant for water treatment, in factory sealed non returnable HDPE containers (40 to 50 Kg each) having chlorine concentration level 65% or above complete all as specified and directed. Note:- The contractor must submit the Certificate of compliance in original from manufactures by all india authorised MES distributor for each batch of product delivery indicating including chemical report by all india distributor.
NAQLI LAL SHARMA AND ARUN SHARMA (BID ID -3318589)
V r traders (BID ID -3319528)
SUBHASH CHAND CONTRACTOR (BID ID -3327568)
M/s badrinath Traders (BID ID -3318461)
Sharma Electrical and Engineering Works (BID ID -3323608)
Raman Electric Trading Co (BID ID -3326877)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .