Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹33.6 L+₹1.0 L (3.13%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹36.7 L+₹4.1 L (12.6%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹37.9 L+₹5.3 L (16.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹49.3 L
EMD Value
₹98,620
Closing Date
31 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR / MAINTENANCE OF VARIOUS CENTRAL /PACKAGE TYPE AC PLANTS AND ITS RELATED WORKS SUCH AS REPLACEMENT OF FILTERS, V BELTS, PULLYS, CONTROLS AT 512 ABWS , CAFVD UNDER AGE E/M II (C) IN GE (C ) KIRKEE
2022_MES_567199_2
CWE/KKE/TOKEN-36 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER TENDER
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹98,620
Yes
1 Mar 2023
10 Jan 2023
3 Feb 2023
10 Jan 2023
31 Jan 2023
18 Jan 2023
Amount
S & F in repairs First Aid Box at E/M installations to keep the first aid items i.e. Tube of bernol, Bandage, one small snizer, banded etc, the box made out of GI sheet of 18 gauge of size 30 cm X 25 cm x 20 cm with openable window & writing letters "FIRST AID" with thick red paint and including fixing arrangement on wall at height not less than 2 mtr complete all as specified and directed by Engineer- In- Charge.
S&F in repair CI Pot Strainer/ Y Stainer with matching flanges, gasket, hardware all as specified and directed of following sizes as per site requirment complete all as specified and directed by Engineer- In- Charge.
80 mm bore
100 mm bore
S & F in repair installation informatory boards at E/M installation to display the technical details of AC plant made out of 3mm thick aluminium composite panel (ACP) fully covered with white/green/blue (as required) Retro Reflective sheeting of Nikkalite Brand Ultralie (UL) grade with using pressure sensitive adhesive and Retro Reflective cut out border and messages in the sensitive adhesive, size of the board 150 cm x 120 cm fixed on wall above 1.2 mtr above ground level with & including proper fixing arragement complete all as specified and directed by Engineer- In- Charge. Note : Technical details as per direction of Engr-in-charge.
Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid , flushing/cleaning with brush and water, re-fixing the side cover with new gasket nut / bolts and detect leakage all as specified and directed by Engineer -in-Charge. Note : Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
M& L for Servicing/Cleaning of FRP cooling tower of following capacity by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as specified and directed by Engineer- In- Charge. Note : Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
16 TR to 45 TR
50 TR to 100 TR
110 TR to 200 TR
Disconnecting/Isolating the compressor from the system by putting plates to the suction and discharge valve opening of the compressor. Dismatling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as specified and directed by Engineer- In- Charge. Note : Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items.
S&F in replacement of following spares for compressor complete all as specified and directed by Engineer- In- Charge.
Piston
Piston ring
Pisotn pin
Shaft seal assembly
Discharge valve reeds
Loading Unloading Frame
Main bearing Bush
CR bearing
Gasket set for 6-65
Gasket set for 8-65
Gasket set for 4-65
Aluminium washer set
Oil pump assembly
Oil ring
O Ring set
Solenoid valve for loading & unloading assembly
Split pin
Sunction valve reed
Thrust collor
Oil filter
Cylinder liner
Oil drain valve
Bushing for connecting rod
Crank shaft complete for SMC 6-65
Crank Shaft for SMC 8-65
Crank Shaft for SMC 4-65
S&F in replacement of following spares for compressor of AC-470 (Make : Kirloskar) complete all as specified and directed by Engineer- In- Charge.
Connecting rod assembly
Piston
Piston ring
Gudgeon Pin
Shaft seal assembly
Paper filter
Sunction valve reed
Discharge valve reed
Gasket set
O ring set
Solenoid valve
Main Bearing
Cylinder liner
Oil drain valve
Oil pump assembly
Crank Shaft for AC - 470
Supply and filling nitrogen gas for leak testing of central & package A/C plants complete all as specified and directed by Engineer- In- Charge.
Supply and filling of R-22 Gas in central & package A/C plantscomplete all as directed and specified by Engineer- In- Charge.
Supply and fillling compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter complete all as specified and directed by Engineer- In- Charge.
S&Fin replacement of defective brassomatic pressure releas valve of suitable size for 300 PSI refrigerent gas pressure complete all as specified and directed by Engineer- In- Charge.
Dismantling, Removing the unserviciable spares from A/C plant of any make & supply & fix new spares for A/C plant of following specifications all as directed by Engr-in-charge.
HP/LP cutout MP 15R
Oil Pressure Switch MP 55
Teflone TAL- O Ring 50 & Tal 40
Brass angle valve 1/4" for freon gas
1 1/8" Brass valve Teflone sheet
Adaptor for valve 3/8" x 1/4"
S&F in replacement of over load relays type MN relay range 14-23 A complete all as specified and directed by Engineer- In- Charge.
S&F in replacement of over load relays type MN relay range 24-40 A complete all as specified and directed by Engineer- In- Charge.
S&F for MCB 40 to 63 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F for MCB 100 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F for MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unitcomplete all as specified and directed by Engineer- In- Charge.
S&F for MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F of MCCB 63 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F of MCCB 100 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F of MCCB 125 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F of MCCB 200 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge.
S&F of MCCB 250 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and directed by Engineer- In- Charge. Note : For item No 18.00 to 23.00 - (i) All cable connections should be done with supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old u/s switch gear is deemed to be included in the rates quated.
S&F in replacement of following spares for central AC plant ;-
Indicating lamps RYB - 01 Set
'V ' belt of size / No C 105
'V ' belt of size / No B 85
'V ' belt of size / No B 108
V ' belt of size / No C 156
Power Contactors ML1.5
Power Contactors ML2
Power Contactors ML3
Power Contactors MNX 18
Power Contactors MNX 22
Power Contactors MNX 40
Power Contactors MNX 50
Power Contactors MNX 70
Labour only for detection of leakage and repairing of central type AC Plant of capacity 24 TR to 60 TR capacity by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results. Note :- Nitrogen gas and refrigerant will be measured and paid separately.
Dismantling of Air Handling Unit of any capacity with complete accessories such as cooling coil ,air filters,blower motor, blower / drum ,blower shaft,side panels , and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cuttercomplete all as specified and directed by Engineer- In- Charge.
Re-assembling/Refixing the complete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by using CTC solution including remetling ,fine grinding blower shaft and hardening balancing , realignment to AHU shaft, replacing unserviceable blower fins ,replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrozen gas and testing and commissioning complete all as specified and directed by Engineer- In- Charge.
S&F for Cast iron Sluice valves class PN 1.6 of size 100mm dia (4") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
S&F for Cast iron Sluice valves class PN 1.6 of size 80mm dia (3") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Taking out unserviceable liquid line valve/discharge line valve from refrigerant line of different size/type for necessary replacement all as directed including cutting / welding of existing pipe linecomplete all as specified and directed by Engineer- In- Charge.
S&F for liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 40 mm dia pipe line including brazing/welding,fixing all as diected and specified
S&F for liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 25 mm dia pipe line including brazing/welding,fixing all as diected and specified
S&F for liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 20 mm dia pipe line including brazing/welding,fixing complete all as specified and directed by Engineer- In- Charge.
S&F forthermostate expansion valve of suitable size for 22TR/30TR capacity air conditioning plants including taking down the unserviceble valve complete all as specified and directed by Engineer- In- Charge.
S&F for thermostate expansion valve of suitable size for 15TR capacity air conditioning plants including taking down the unserviceble valve complete all as specified and directed by Engineer- In- Charge.
S&F for thermostate expansion valve of suitable size for 7.5TR capacity air conditioning plant including taking down the unserviceble valve complete all as specified and directed by Engineer- In- Charge.
S&F for thermostate expansion valve of suitable size for 5TR capacity air conditioning plants. including taking down the unserviceble valve.
S&F for water pressure gauge 0-7 Kg/Sqm including taking down the unserviceble gauge complete all as specified and directed by Engineer- In- Charge.
S&F for refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gaugecomplete all as specified and directed by Engineer- In- Charge.
S&F for in replacement of pressure release valve of condensor 3/8" BSP threaded suitable for 300 PSI complete all as specified and directed by Engineer- In- Charge.
S&F for in replacement of DB/WB thermometer wall mounted with the facility of RH readings complete all as specified and directed by Engineer- In- Charge.
Taking down carefully and overhauling of Monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable wornout bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump:-
7.5 HP to 10 HP
12.5 HP to 20 HP
M&L in replacement of 50mm bore GI pipe medium grade incl all fitting and acessories complete all as specified and directed by Engineer- In- Charge.
M&L in replacement of 40mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
M&L in replacement of 25mm bore GI pipe medium grade incl all fitting and acessoriescomplete all as specified and directed by Engineer- In- Charge.
M&L in replacement of 20mm bore GI pipe medium grade incl all fitting and acessories complete all as specified and directed by Engineer- In- Charge.
S&F for Gate Valves (Brass Insert) of 50 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F for Gate Valves (Brass Insert) of 40 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F for Gate Valves (Brass Insert) of 25 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F for Gate Valves (Brass Insert) of 20 mm bore, ISI marked , heavy duty incl taking down old one complete all as specified and directed by Engineer- In- Charge.
S&F forfloat valve/ball type assemblt complete of size 20 mm size dia.complete all as specified and directed by Engineer- In- Charge.
Painting of CI/GI/MS pipes of Air / Water distribution of size 100/80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code complete all as specified and directed by Engineer- In- Charge..
M&L painting to cooling tower inside and outside with one coat of primer and one coats of epoxy paint of approved colour including scapping out the old paint complete all as specified and and directed by Engr-In-charge.
M&L for painting of storage tank with one coat of primer and one coats of synthetic enamel paint approved colour including scapping out the old paint complete all as specified and directed by Engr-In-charge.
M&L for Mild Steel brackets, frames ,supports, channels and stands of type as required at site made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
S&F for double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 500 x 50mm.
S&F for double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 400 x 50mm complete all as specified and directed by Engineer- In- Charge.
S&F for double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 610 x 610 x150mm complete all as specified and directed by Engineer- In- Charge.
M&L for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds complete all as specified and directed by Engineer- In- Charge.
M&L for Copper piping 1 1/8" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds or frame etc.
M&L for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds complete all as specified and directed by Engineer- In- Charge.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 70 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and directed by Engineer- In- Charge.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and directed by Engineer- In- Charge.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 25 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and directed by Engineer- In- Charge.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and directed by Engineer- In- Charge.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 6 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and directed by Engineer- In- Charge.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5 HP to 12.5 HP all as specified and directed.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 15 HP to 20 HP all as specified and directed.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 30 HP to 40 HP complete all as specified and directed by Engineer- In- Charge.
Disconnection and taking out old defective Hermetically reciprocating sealed compressor unit as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage,vaccumising etc of capacity 3 TR for pakage AC plants of the existing complete all as specified and directed by Engineer- In- Charge.
Disconnection and taking out old defective Hermetically reciprocating sealed compresso as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vaccumnsing etc of capacity 5 TR for pakage AC plants of the existing complete all as specified and directed by Engineer- In- Charge. .
M&L for fabrication and installation of glow Sign board (640 cm x 91cm x 25cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having with intenal tube light fitting arrangement to open the flex/Acrylic board and suitable for mounting on wall/ gate complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
M&L for fabrication and installation of Sign board (240 cm x 91cm x 25 cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
M/S. Niksun Electro-Infra Private Limited
M/S. OM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .