| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 CrAccepted-AOC | ₹19.5 Cr Quoted ₹19.9 Cr | L1 | Accepted-AOC The lowest and negotiated bidder M/s. Tharun Construction and co is accepted by the 132th TAC meeting on 27.02.2026 |
| 2 | L2₹20.7 CrRejected-AOC 7 3 PUDUMARAPPANUR ARIYUR POST NAMAKKAL 637 015 TAMIL NADU | NAMAKKAL | TAMIL NADU | 637015 | ₹20.7 Cr | L2 | Rejected-AOC Other than lowest tenderer |
| 3 | Rejected-Technical NO 5 KOTTAI NAICKEN STREET KALAPPA NAICKENPATTI NAMAKKAL 637404 | NAMAKKAL | TAMIL NADU | 637404 | - | - | Rejected-Technical Not Qualified in Technical Evaluation as approved by 125th TAC |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Qualified in Technical Evaluation as approved by 125th TAC |
| Sl No | Description | Qty | Unit | SRI NAACHIMAAR ENGINEERING CONSTRUCTIONS L2 | M/s Tharun Construction & Co L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling, Brick / stone masonry in Cement mortar walls under 3m high | 252.68 | M3 | 312 ₹78,836.16 | 306 ₹77,320.08 |
| 2.00 | Dismantling Pressed tiles & weathering course | 2,783.36 | M2 | 55 ₹1.5 L | 50 ₹1.4 L |
| 3.00 | Dismantling RCC by manual / by using deplying machineries | 187.86 | M3 | 4,750 ₹8.9 L | 4,650 ₹8.7 L |
| 4.00 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth.
Data worked out for 48 m3 per day/8 hrs. | 1,049 | M3 | 375 ₹3.9 L | 365 ₹3.8 L |
| 5.00 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. A). Upto 2.40m Depth. | 398 | M3 | 210 ₹83,580 | 200 ₹79,600 |
| 6.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 118 | M3 | 5,700 ₹6.7 L | 5,600 ₹6.6 L |
| 7.00 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 117 | M3 | 2,030 ₹2.4 L | 2,000 ₹2.3 L |
| 8.00 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 403 | M3 | 500 ₹2.0 L | 490 ₹2.0 L |
| 9.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 142 | M3 | 170 ₹24,140 | 160 ₹22,720 |
| 10.00 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means | 89 | M3 | 5,650 ₹5.0 L | 5,600 ₹5.0 L |
Updated dates
Tender Value
₹19.5 Cr
EMD Value
₹9.8 L
Closing Date
30 Jan 2026, 11:00 amClosed
Superintending Engineer PWD
Buildings C and M Circle Salem
Construction of Farmers Hostel M and W and veterinary Hostel in 1st and 2nd floors, Common Dining hall, partition work to CR and Lab and establishment of lab facilities with waiting hall in Slaughter house in the AIIRLIVAS at Thalaivasal in Salem Dt
2026_PWD_643747_1
42/2025-26
Open Tender
Civil Works - Buildings
360 days
Thalaivasal in Salem Dt
Please refer Tender documents.
17 documents required · 17 mandatory
₹0
₹9.8 L
6 Mar 2026
14 Jan 2026
30 Jan 2026
14 Jan 2026
30 Jan 2026
14 Jan 2026
Dismantling, Brick / stone masonry in Cement mortar walls under 3m high
Dismantling Pressed tiles & weathering course
Dismantling RCC by manual / by using deplying machineries
Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. Data worked out for 48 m3 per day/8 hrs.
Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. A). Upto 2.40m Depth.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means
Brick work in following Cement Mortar in 1:3 using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.-In Foundation & Basement
Brick work in following Cement Mortar in 1:5 using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.-In Foundation & Basement
Brick work in following Cement Mortar in 1:6 using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
For foundation & basement
In Ground floor
In First floor
In Second floor
In Third floor
Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
In Ground Floor
In First Floor
In Second Floor
Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Manual Mixing
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid)
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
In Foundation & Basement
In Ground floor
In First floor
In Second Floor
In Third floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
In Foundation & Basement
In Ground floor
In First floor
In Second Floor
In Third floor
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means -In Foundation & Basement
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete and as directed by the departmental officers. - Mixing by mechanical means
For Ground floor
For Second floor
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)-For 40mm thick
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.-50mm thick slab (using 20mm HBGS Jelly)
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
In First floor
In Second Floor
In Third floor
Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. Using Pressed Tiles of 230mm x 230mm x 16 mm to 18mm
Paving the floor with best quality Double Charged Vitrified Tiles of Size: 600 x 600 x 8 mm conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of following size and Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) Fine Polished Granite Slab of Size : 1200 x 600 of 18 / 20mm thick Variety : Synthetic Grey, Paradise and similar varieties
Providing full nosing to the steps or platforms to the Granite slab of 20mm thick including neat finishing, polishing, cost of powder, tools etc as directed by the departmental officers
Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Plain Ceramic Tiles of size 305 x 305 x 6mm
Dadooing walls with following best approved quality, plain colour glazed tiles conforming to IS 15622 of sizes 150x150x6mm in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm
Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers-110mm Dia PVC Pipe
One Floor
Three Floor
Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing solid core flush shutter of following type with 35mm thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Butt Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers
Single leaf
Double leaves
Supply and fixing doors as per drawings with WPC Solid 3 layer and ISI marked flush door shuttrs of 30mm thick single shutter withh bond wood solid block board type of 0.7 D WPC Sheet including cost and conveyance to site of WPC Shuuter including supply and fixing cost of ISI marked Aluminium fixtures of 3 Nos. butt hnges 150mm long, 1 No. aldrop 300mm, 1 No, tower bolt of 200mm x 10mm dia at top, 2 Nos. 150mm long handles, 1No door stopper and 1No. Rubber / Nylon door stop bushesincluding fixing the fixtures to door with requried number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & Contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10mm) (900mm x 2100mm)
Supply and installation of two-track sliding UPVC windows with integrated fly mesh shall utilize uPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 92mm x 52mm x 52mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, a glazing bead of 24.5mm x 16mm, and a fly mesh shutter of 66mm x 30mm. All profiles of frames, sash, and mullion shall be reinforced, where required, with 1mm thick GI steel sections. Each window will be equipped with various security devices, such as touch locks or crescent locks, along with nylon rollers and an aluminium track for smooth operation, all supplied as per requirements, compliant with relevant specifications, and as directed by departmental personnel. The windows shall incorporate 5mm thick Plain or Pinhead glass, held securely by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash are to be mitred cut and fusion welded without any mechanical joints, with all welded joints neatly trimmed and finished with a grooved nib to ensure the final products are free from sharp edges. The complete window units shall be fixed into prefinished openings by drilling and fastening through the outer frame using high-quality fasteners, and silicon sealant will be applied to fill the gap between the wall and window frame for a leak-proof installation and complete finish etc., Complete and as directed by the department officers.
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is
provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m.-Single leaf
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers-38 / 40mm thick
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers.( The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc.,complete. The putty should be got approved by the Executive Engineer before use on work
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work).
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Plastering the surface of walls with Cement Mortar 1:4 (One cement and Four plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level.
25mm dia UPVC Pipe-Internal water supply water supply arrangements Above Ground level
25mm dia UPVC pipe-External water supply water supply arrangements Above GL
32mm dia UPVC pipe-External water supply water supply arrangements Above ground level
40mm dia UPVC pipe-External water supply water supply arrangements Above ground level
50mm dia UPVC pipe-External water supply water supply arrangements Above ground level
Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements
25mm Dia UPVC Union
32mm Dia UPVC Union
40mm Dia UPVC Union
50mm Dia UPVC Union
25mm dia UPVC Elbow.
32mm dia UPVC Elbow.
40mm dia UPVC Elbow.
50mm dia UPVC Elbow.
25mm dia UPVC. Tee.
32mm dia UPVC Tee
40mm dia UPVC Tee
50mm dia UPVC Tee
32X25 dia UPVC Reducer
25x20 dia UPVC Reducer
20x15 dia UPVC Reducer
25 mm dia UPVC Nipple
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25 mm dia G.M. Gate Valve
32 mm dia G.M. Gate Valve
40 mm dia G.M. Gate Valve
50 mm dia G.M. Gate Valve
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and
also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror of following size , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size :600 x 450 mm / 500 x 400mm / 1000 x 780 mm.
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
75mm dia PVC soil / waste pipe
110mm dia PVC soil / waste pipe
160mm dia PVC soil / waste pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
75mm dia PVC Elbow
75mm dia PVC Tee
75mm dia PVC Tee with single door
75mm dia PVC Bend
110mm dia PVC Elbow
110mm dia PVC Tee
110mm dia PVC Tee with single door
110mm dia PVC Bend
160mm dia PVC Elbow
160mm dia PVC Tee
160mm dia PVC Tee with single door
160mm dia PVC Bend
Supplying and fixing position CI Nahani Trap / Floor Trap of the 75x50mm sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Construction of INSPECTION CHAMBER 0.60x0.60m clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of fly ash Bricks of size 230x110x70mm with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. CLEAR SIZE 0.60 X 0.60
Supplying and fixing of SS Sink of size 1200 x 550 x 180mm etc., complete complying as directed by the departmental officers as per standard specification.
RCC Pipe 1.20m dia to a length of 0.30m and 5cm tk using cement concrete 1:2:4 using HBGS Chips including cost of Reinforcement Grills and neat finishing etc.,
RCC Precast slab lid 1.30m Dia to a thickness of 5cm using cement concrete 1:2:4 including cost of Reinforcement grills and neat finishing etc.,-RCC PCC Slab lid 1.30m
Supplying and fixing best quality and make of ready mixed 1000 litre capacity PVC water storage Water tanks made of PVC materials- including necessary provision for conveying, jointing delivery line, scour pipe, over flow pipe etc., and lifting the tank to the top of the building placing in position etc., complete
Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification.
Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification.
Supplying and erecting 5 H.P (3 Phase) Submersible with ISI mark with necessary accessories (motor should be got approved by Executive Engineer before use on works) complete complying with standard specification.
Supplying and fixing wall mounting of 3 Phase Panel board with following accessories a.Suitable DOL type push botton automatic starter etc., complete.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification
Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of double leaves door with half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section-Vertical &Top rail: 50x44.45x2.50mm @ 1.292 kg/m and Bottom rail : 100 x 44.45 x 2.50mm @ 1.974 kg /m , Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 2Nos ., lock-1No., Door stopper with rubber bush including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beam masonry with
power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete complying with standard specification and as directed by the deparmental officers.. All the Alu. sections are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.
Fabricating Spplying and fixing in position of aluminium anodised natural colour matt finish Double leaf shutter with half panelled, 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top. The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319 kg/m and Shutter frame made of section bottom rail 100x44.45x2.50mm @ 1.974 kg/m,Top&Vertical rail : 50x44.45x2.50mm @ 1.292kg/m,Lock rail: 50x44.45x2.50mm @ 1.292kg/m, Alu.clips:17.15x17.27x1.50mm @ 0.176kg/m,Aluminium Handle : 100x30mm @ 0.988kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closser - 2Nos ., lock-1No., Door stopper with rubber bush as per BIS standards including cost of all materials, labour
charges and power consumption charges required for fabrication including chipping dismantling and making holes to the required extent in RCC in column/beam/masonry with power drill wherever neccessary and redoing the demaged portion to the original condition after fixing etc. complete complying with standard specification and as directed by the deparmental officers...Alu. Section are to be anodised with matt finish under electricaly controlled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.
Hydraulic Door Closer of various sizes of approved quality using Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer with Double Speed Adjustment like HARDWYN (make) ‘GAZEL’ (or) Equivalent (with ISI Monogram)
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points /Coil) Higher End) (SD-289)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. (SD-293)
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End. (SD-309)
Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. (SD-402)
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. (SD-390)
Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. (SD-438)
Supply and fixing of 20 A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) (SD-144)
Supply and fixing of WT bulk head fitting suitable with guard and 15 W (100W) LED bulb. (SD-85)
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. (SD-443)
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. (SD-457)
Supply and fixing of 1200mm (48") BLDC Ceiling Fan complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp. (DATA-1)
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD-114)
Supply and fixing of 450mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD-118)
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan. (SD-120)
Supply and fixing of light trap arrangements for 450mm (18") sweep exhaust fan. (SD-123)
Supply and fixing of 63A FP MCB in sheet steel enclosure (Higher end) inflush with wall and making good of the concealed portion with earth connection only. (DATA-2)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. (SD-523)
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with earth connection only. (SD-630) i) 63A 4P MCB - 1 no. ii) 63A 4P 30MA RCCB/ELCB - 1 no. iii) 63A DP MCB Isolator -3 nos. iv) 6A to 32A SP MCB - 12 nos (lighting & Power)
Supply and fixing of 6 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB incomer) with double door (metal door) with 1 No 125A 4P MCCB as incoming and 4 Nos 63A 3P MCB, 2 Nos 32A TP MCB as outgoing with suitable cable end box in flush with wall with Earth connection only. Higher End. (DATA-3)
Supply and fixing of 1000W automatic electric water heater of 25 litres capacity suitable for 230V 50c/s AC supply on suitable MS clamps with 3 core flex wire,but without plumbing work. (SD-103)
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. (SD-348)
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-57)
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-63)
Supply and run of 4 of 16 sq. mm (101/0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16Sq.mm copper wire and making good of the concealed portion with suitable colour. [For 4W 7S TPN MCB DBs for lighting & 6W 7S TPN MCB DBs for Power] (DATA-4)
Supply and run of 4 of 25 sq. mm (168/0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 25 Sqmm copper wire and making good of the concealed portion with suitable colour. [6 Way 125A Vertical type MCCB DB] (DATA-5)
Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD-669)
Supply and clamping of 3-1/2 x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. (SD-206)
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection. (SD-165)
Supply and providing cable end termination of 3-1/2x35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD-224)
Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD-671)
Supply and clamping of 3-1/2 x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. (SD-208)
Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. (SD-167)
Supply and providing cable end termination of 3-1/2x70sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD-226)
Supply and Laying of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD-674)
Supply and clamping of 3-1/2 x 150 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. (SD-211)
Supply and fixing of brass cable gland for 3-1/2 x 150 sq.mm. PVC armoured LTUG cable with earth connection. (SD-170)
Supply and providing cable end termination of 3-1/2x150 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (SD-229)
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40 mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (SD-221)
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. (SD-372)
Supply and run of 25mmx3mm tinned copper flat with necessary clamps /supports on wall/ floor/ ground for earth connection. (SD-76)
Supply, Erection, testing and Commissioning of 1.5TR (4500K cal / hr) ABS plastic split inverter type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-32/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply as per BEE Specification and capable of performing the following functions.
The installation work for the above split type AC units includes the following. (A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering. 1. Mounting / fixing indoor and outdoor units at their respective locations. 2. Laying refrigerent pipe line of 3 Mtrs. Distance and connecting the both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.80mm. 3. Installing the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6 Mtrs. Length to throw out the condensate water being formed in the indoor unit. 5. Leakage testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make - Carrier / Voltas / Blue Star make only) (SR)
Supply and Erection of 4 KVA Voltage stabilzer for 1.5 TR split type AC unit high / low voltage cut off time delay relay with input voltage cut off time range of 170V - 270V and out put range of 200 - 240V with 3 minutes time delay relay (V.GUARD make VGS 500) (SR)
Supply and fixing of 5/8" Copper Pipe and 3/8" Copper Pipe for connecting the Indoor and outdoor unit with insulating the copper tubes with thermal insulation above the standard length. (SR)
Supply and fixing of MS stand for fixing outdoor unit
Supply, Erection, Testing & Commissioning of 250A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bars chamber & two numbers of Horizontal cable chamber at top and bottom. 250A FP SDF Double Break switch with HRC fuse units - 1Nos as incoming. Outgoings: 125A TP SDF Double Break switch with HRC Fuse units - 4Nos. 63A TP SDF Double Break switch with HRC Fuse units - 4Nos. The bus bar chamber consist of 4nos. of 30mmx6mm Copper flat for three phases and also for interconnection for 250A switch and 1no. of 25mmx3mm Copper flat for neutral. The interconnection with the bus bars to the 125A SDF DB Switches with 30mmx3mm Copper flat and that 63A SDF DB Switches with No.8 SWG Copper Conductor. And Double earth connection to all the switches should be done using No.8 SWG Copper
conductor. The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition 2 runs of 1"x¼" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit. The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches. The Panel should be mounted on angle iron frame work of size 1½"x1½"x¼" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) (DATA-6)
Supply, erection testing, commissioning and handing over of 1No, 58.5KVA diesel generator set with auto main failure (AMF) panel of 0.8P.F, 3phase, 415v/420 Volts, 50c/s, 1500 RPM latest CPCB IV + approved capacity complete in all respects as detailed below: A.Engine Water cooled diesel engine suitable for generator application with a shaft out put of 78 BHP suitable at 1500 RPM under NTP conditions as per BSS 5414-ISO 10000. The engine shall comprise the following standard scope of supply: 1) Dry type Air cleaner 2) Expansion bellow 3) Radiator, radiator fan and mounting 4) Air to air charge cooler 5) Exhaust gas turbo charger 6) Lube oil cooler and lube oil filter 7) Fuel filter (pre and micro) 8) In-line mono-block fuel injection pump with governor and fuel feed pump 9) Electronic governor 10) 12V / 24V Volt electric starter motor 11) Engine test certificate 12) Residential Mufler
13) Fly wheel with starter ring. Engine instrument panel/ mounted Engine control panel consisting of ON / Off / Start / Key, lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator. Safety system of Engine: The engines shall trip for the following conditions with Visual alarm device. 1)Low lubricating oil pressure. 2)High water temperature. 3) Vee - belt failure and over speed. 4) Low battery indication The Engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load. B) ALTERNATOR Alternator capacity of 58.5KVA, 100 KW AC 3phase, 50HZ, 415 Volts, 0.8P.F, 4 wire self exited, self regulated design to run at 1500 RPM under NTP conditions conforming to BS 5000/IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate.
24) 1No signal lamp for indicating ‘Set running’ 25) 1No signal lamp for indicating ‘Battery charger ON’ 26) 1set pilot lamps of 3Nos 27) MCCB of 63A capacity with magnetic thermal over load release, instant short circuit trip and under voltage release switch. 28) Rectangular copper bus bars (1No for each phase, neutral and earthing terminal) of adequate capacity duly colour coded with heat shrinkable PVC sleeves. 29) 1No mains voltage monitor 30) Hooter/Audio alarm for indicating set fails to start and for DG O/L 31) 1set timers 32) Audio and visual indication arrangements for a) Low lubricating oil pressure b) High water temperature c) Over speed 33) 1No Earth fault relay 34) Isolator to Isolate the neutral
Note: 1. The control panel should be complete with necessary fuses, cables lable other accessories and with neutral isolation arrangements. 2. The engine should trip for the following conditions. a) Low lubricating oil pressure b. High water temperature c. Overspeed 3.Supply and fitment of Auto mains failure panel 1EB service with 63Amps switch and contactors SUF control relays timers etc. 4) ACOUSTIC ENCLOSURE: Acoustic enclosure shall be powder coated and fabricated of 16SWG CRCA MS sheet. The silent canopy shall be nut bolt type construction. Critical processes of punching are done on CNC machine to maintain dimensional accuracy of hole within 0.1mm powder coating done after seven tank surface preparation process of sheet metal.
Canopy panel and door shall have inside lining of FIRE-RETARDANT 64kg/m density mineral wool of 100mm thickness as acoustic material. Four hinged doors shall be provided to canopy. The maximum permissble sound pressure level should be as per the norms prescribed by the Central Pollution Control Board / State Pollution Control Board/ Competent Authority concerened or should be with in 75 db(A) at 1meter from the enclosure surface whichever is advantageous to the department. The emergency stop should be available on the enclosure panel. The enclosure provided shall be duly approved by the Engine Manufacturer of the Engine provided for Diesel Generator Sets mounted inside and should be to the satisfaction of inspection / testing authority concern. SURFACE TREATMENT – PAINTING The enclosure shall be suitably treated for degreasing, de-rusting and phosphating. The canopies are passed through seven-tank treatment thoroughly. ADDITIONAL FEATURES OF CANOPIES Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any.
WORLD CLASS COOLING PACKAGE: Canopies shall have cooling package for which it can perform at 45 deg c/ ambient temperature. No grounding required on the ground, only a level surface capable of with standing the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well with in 5-7 deg centigrade. 5) BASE FRAME Base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure on it. DG Set should be offered complete with exhaust piping, ie, silencer is mounted and connected by means of MS pipe through flexible pipe to the engine manifold. Entire exhaust piping inside the conopy (Cold Zone) is insulated by means of ceramic wool and aluminium gladded The supply of Gen set includes loading, unloading and transportation charges.
6) Fuel Tank 125 Ltrs. Removable Fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet an outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. First charging of fuel oil to full capacity and first charging of battery while handing over to dept. 7) Battery 1No 12V 150 Ah battery 8) Tools Supply tools such as 15" cutting plier - 1 No Screw Driver 9" & 6" - 2 Nos, DE Spanners (6 Nos) - 1 Set Adjustable Spanner - 1 No 1/2 lb Hammer - 1 No Spanner for removing engine oil plug - 1 No Line Tester - 1 No for the maintenance and operation of generator. (SR-M-2331)
ERECTION, TESTING AND COMMISSIONING: Providing suitable concrete foun-dation with cement concrete 1:2:4 with sand cushion all around the foundation for erection of 58.5KVA Diesel Generator set upto a height of 3ft from the floor level.
Exhaust Piping: Supply and installation of exhaust piping of sufficient length with suitable MS pipe so as to exlend outside the generator with necessary thermal insulation. (SR)
Supply and demonstration of the following safety accessories’ a)1 meterx1 meterx1/2 inch 11kv rubber mat-2 nos. a)1 meterx1 meterx1/2 inch 11kv rubber mat-2 nos. b) one set of 4 nos. 9 liters fire buckets with metal stand frame - 1set c) first aid box with medicine - 1no d) 11 kV rubber hand gloves - 2 nos. e) 2 Kg capacity dry powder type fire extinguishers-2nos f) Hand operated pump to transfer fuel from standard barrel to fuel tank - 1 no. g) First aid chat in Tamil and English - 1no. h) Battery water acidity tester -1 no. i) Earth discharge rod - 1 No j) Danger board - 1 No k) PL Lamp - 1 No
Supply and fixing of 250 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD Earthing.g. (SD-659)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.83 MB
PQconditionmergeAIIRLIVAS.pdf
Additional Documents • 1.64 MB
AIIRLIVAS2066mergeConditions.pdf
Tender Documents • 1.79 MB
BOQ_771401.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid