Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr Quoted ₹2.7 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹2.7 Cr+₹94,580.70 (0.36%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹2.7 Cr+₹94,580.70 (0.36%) | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹2.8 Cr+₹12.9 L (4.86%)Rejected-Finance | ₹2.8 Cr+₹12.9 L (4.86%) | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹2.8 Cr+₹16.2 L (6.09%)Rejected-Finance 71 GOLA MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹2.8 Cr+₹16.2 L (6.09%) | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹2.9 Cr+₹25.6 L (9.66%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹2.9 Cr+₹25.6 L (9.66%) | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
6 Sept 2023, 6:00 pmClosed
BRIG SUSHIL KUMAR CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
ADDN ALTN AND SPL REPAIRS TO BLDG No O 7 AND BLDG No S 21 AT CLYDE ROW UNDER GE CENTRAL KOLKATA
2023_MES_609078_1
89077/E8
Open Tender
Civil Works
Works
360 days
GE CENTRAL KOLKATA
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE CENTRAL KOLKATA
₹3.9 L
Yes
27 Oct 2023
14 Jul 2023
13 Sept 2023
14 Jul 2023
6 Sept 2023
23 Aug 2023
Amount
Taking down cement or cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & directed by Engr-in-Charge.
Material and labour for rendering 20mm thick plaster in two layers (Top layer shall be of 10mm thick liquid water proofing compound shall be laid over 10mm thick plastered surface) in CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified & directed by Engr-in-Charge. Note: liquid water proofing compound (WPC) best quality will be measured and paid separately under respective items of BOQ
M&L for rendering 15mm thick plaster in cement mortar (1:6) mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-in-Charge. Note: liquid water proofing compound (WPC) best quality will be measured and paid separately under respective items of BOQ
M&L for rendering 5mm thick in cement mortar (1:3) mixed with liquid water proofing compound on ceiling/chajja concrete surfaces, finished even and smooth without using extra lime or cement complete all as specified & directed by Engr-in-Charge. Note: liquid water proofing compound (WPC) best quality will be measured and paid separately under respective items of BOQ
Supply only liquid water proofing compound (WPC) best quality complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new surface & applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon extracts @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of walls complete all as specified & directed by Engr-in-Charge.
M&L for complete removal of existing old surface & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces
M&L for complete removal of existing treatment and applying two coats of cement base paint on walls complete all as specified & directed by Engr-in-Charge.
M&L for complete removal of existing treatment/old decorated surfaces of walls and application of 1.5mm thick cement putty and allow it to dry completely and application of two coats of distemper oil emulsion over a coat of alkali resistance primer complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls (Internal surfaces) and application of 1.5mm thick cement putty and allow it to dry completely and application of two coats of distemper oil emulsion over a coat of alkali resistance primer complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed by Engr-in-Charge.
M&L for preparation of old plastered surfaces of ceiling of any description and applying one coats of white wash complete all as specified & directed by Engr-in-Charge.
M&L for preparation of old decorated surfaces of wall of any description and applying one coat of white wash complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted wooden surfaces of any description and apply one coat of synthetic enamel paint, not otherwise described, over 10cm width or girth complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted steel surfaces of any description and one coat of synthetic enamel paint, not otherwise described, over 10cm width or girth complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces or previously untreated surfaces of any description and in any position not otherwise described exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces or previously untreated surfaces of any description and in any position not otherwise described n. exc. 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces or previously untreated steel surfaces of any description and in any position not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces or previously untreated steel surfaces of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Demolition brickwork built in cement mortar including all quoins, arches, pillars, etc, but excluding Precast concrete completes all as specified and directed by Engr-in-Charge
Material and Labour for brickwork with fly ash bricks built in cement mortar 1:4, straight or curved on plan to any radius in half brick thick walls completes all as specified and directed by Engr-in-Charge.
Material and Labour for brickwork with fly ash bricks built in cement mortar 1:4, straight or curved on plan to any radius in half brick thick walls completes all as specified and directed by Engr-in-Charge.
Demolition of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. completes all as specified and directed by Engr-in-Charge.
Material and Labour for 16-18 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of mortar 15 mm thick built in cement mortar 1:4 completes all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises completes all as specified and directed by Engr-in-Charge.
Material and Labour for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including provision of 15 mm thick screed bed in CM 1:4 completes all as specified and directed by Engr-in-Charge.
Material and Labour for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement tomatch the surface including provision 10mm thick plaster in CM 1:3 on fair faces of brick work or concrete surfaces completes all as specified and directed by Engr-in-Charge.
Material and Labour for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including provision of 15 mm thick screed bed in CM 1:4 completes all as specified and directed by Engr-in-Charge.
Material and Labour for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm as skirtings, dados, risers etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including provision of 10mm thick plaster in CM 1:3 on fair faces of brick work or concrete surfaces completes all as specified and directed by Engr-in-Charge.
Material and Labour for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tileexceeding 0.18 sqm but not exceeding 0.36 sqm, in verandah/corridor floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including provision of 15 mm thick screed bed in CM 1:4 completes all as specified and directed by Engr-in-Charge. Make: Johnson tiles (brand: Johnson Endura) or Equivalent.
Materials and Labour pre-polished chequered cement concrete tiles of size 300mm x300mm x25mm thick, with grey cement and no pigment, jointed in neat cement slurry and pointed in white or coloured cement to match the surface including provision of 15 mm thick screed bed in CM 1:4 including taking out old unserviceable chequered tiles completes all as specified and directed by Engr-in-Charge.
Demolition of concrete of any description(un-reinforced) and in any position not otherwise specifically provided for completes all as specified and directed by Engr-in-Charge.
Material and labour for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in roof kerbs, rounder or chamfered on edges etc. including necessary formwork complete all as specified & directed by Engr-in-Charge.
Materials and labour 75 mm thick cement concrete type D-2, 1:2:4 (40mm graded aggregate) as in sub base completes all as specified and directed by Engr-in-Charge.
Material and Labour plain cement concrete 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregates) as in flooring and finished even & smooth using extra cement completes all as specified and directed by Engr-in-Charge.
Material and Labour for precast RCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slabs for manholes / gully traps / drain etc set in cement mortar (1:4) complete including necessary form work complete all as specified and directed including demolition of old unserviceable cover slab.
M&L TMT MS bars upto and including 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Material and Labour for reinforced cement concrete (nominal mix) type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors and the like completes all as specified and directed by Engr-in-Charge.
Chipping off 25mm average thickness for slabs, Chajja, lintel & roof unsound /week concrete materials up to 4 story bldg by any means as directed by Engr-in-charge including tapering all edges, making regular shape, size and cleaning of exposed concrete surface completely out of any loose foreign materials/aggregate etc and disposal of all debris up to lead of 50mtr complete all as specified & directed by Engr-in-Charge.
Chipping off 50mm average thickness for slabs, Chajja, lintel & roof unsound /week concrete materials up to 4 story bldg by any means as directed by Engr-in-charge including tapering all edges, making regular shape, size and cleaning of exposed concrete surface completely out of any loose foreign materials/aggregate etc and disposal of all debris up to lead of 50mtr complete all as specified & directed by Engr-in-Charge.
M & L for providing and placing in position free flow non-shrink cementitious micro concrete of grade of M-50 to the effected beam, roof, chajja etc25 to 50mm average thickness and the micro concrete shall have a minimum 1 day compressive strength of 10 Mpa and 28 days strength of 60 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28days complete all as specified & directed by Engr-in-Charge.
Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as spd and directed by the Engr-in-charge upto 25 mm average thickness and upto 4 storey High. Make :- Sika/Fosroc NOTE:- Cement and sand morter in proportion of 1:2 graded coarse sand ) with polymer admixed in proportions approved by Engr-in-charge) Note: The rates shall be include all necessary formwork
Removal of concrete all around up to 12mm dia reinforcement including from behind the reinforcing bars to give an average 25mm by manual methods of hammering bar using wire brushing, chiselling etc and removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry and applying alkaline rust removing chemical complete all as specified & directed by Engr-in-Charge.
Removal of concrete all around above 12mm dia reinforcement including from behind the reinforcing bars to give an average 25mm by manual methods of hammering bar using wire brushing, chiselling etc and removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry and applying alkaline rust removing chemical complete all as specified & directed by Engr-in-Charge.
M & L for providing single coat of epoxy bond adhesive of prepared non-metallic surface (existing surface) up to 4th Story Bldg and applying by brush all as per manufactures instruction/ specification complete all as specified & directed by Engr-in-Charge.
M & L for introducing new reinforcement bars n. exc 12 mm dia bar restricted up to 2 storey building for structural connection in RCC beams, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified & directed by Engr-in-Charge.
M & L for applying Epoxy Zinc rich primer on the prepared reinforced surface by brush up to 2 Story Bldg and the primer(n.exc 10 cm width/girth) shall have a minimum specific gravity 1.75 minimum weight film thickness/ coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified & directed by Engr-in-Charge.
M & L for application of cementitious grouting admixture up to 4 storeys of building with the cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a pressure grouting pump through non-return PVC nozzles Prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface complete all as specified & directed by Engr-in-Charge. Make: Fosroc /Elantas beck / Kunal conchem
M & L Welding in repairs n. exc 2.5cm in length up to 4 story Bldg thickness of metal to be welded Exc. 9mm but n.exc 20mm complete all as specified & directed by Engr-in-Charge.
Stripping of old tarfelt including layer of plaster or mortar of any thickness of earlier treatment carefully from roof surfaces without damaging the roof and roughening of surface of old concrete roofing by picking, sweeping, cleaning and washing down with water to remove dust particle complete all as specified & directed by Engr-in-Charge.
M&L for 20mm thick screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified & directed by Engr-in-Charge.
Material and labour for applying tack coat industrial bitumen 85/25 at the rate of 1.2 kg /sqm including cleaning of surface and laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non-woven fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified & directed by Engr-in-Charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (withouttaking off shutters from the frame) complete all as specified & directed by Engr-in-Charge.
Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames) complete all as specified & directed by Engr-in-Charge.
Taking down shutters of any description shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified & directed by Engr-in-Charge.
S&F plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified & directed by Engr-in-Charge.
S&F 2nd class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engr-in-Charge.
S&F 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified & directed by Engr-in-Charge.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed by Engr-in-Charge.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing up to 04 storeys building complete all as specified & directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing up to 02 storeys building complete all as specified & directed by Engr-in-Charge.
S&F powder coated aluminium 50 micron anodised three way track sliding windows of frame size 92mm x 31.75mm x 1.5mm thickness weight of 1.07Kg/m (Section No 20831 of Jindal) and of shutter size 40mm x 18mm (with 9.00 mm interlocking legs) x 1.45 mm thickness (section No 20737 of Jindal) section two shutter glazed, cover half of span of opening each & one shutter skeleton covering half of span of opening) including provn for making window air tight including 95mm aluminium handle with spring lock, stainless steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with steel wire staples 5 mm thick plain glass including necessary fitting and fixture, aluminium snap beading complete all as specified. Note - Measurement shall be taken clear opening ie out to out of window frame as a whole including all fittings and fixture after taking down steel window complete all as specified & directed by Engr-in-Charge. Note: Cost of glass and wire cloth are inclusive in the item of work.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with having 150mm overall length of cover plate fixed in floor complete all as specified & directed by Engr-in-Charge.
S&F 150mm size aluminium handle, cast type anodised complete all as specified & directed by Engr-in-Charge.
S&F in repair 150mm size aluminium handle, cast type anodised complete all as specified & directed by Engr-in-Charge.
S&F 100mm size Butt hinges, medium weight, cold rolled mild steel complete all as specified & directed by Engr-in-Charge.
S&F 75mm size Butt hinges, medium weight, cold rolled mild steel complete all as specified & directed by Engr-in-Charge.
S&F in repair100mm size Butt hinges, medium weight, cold rolled mild steel complete all as specified & directed by Engr-in-Charge.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engr-in-Charge.
S&F in repair 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engr-in-Charge.
S&F 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.
S&F in repair 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.
S&F in repair 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.
S&F in repair powder coated 20/25 mm dia of curtain rod with brackets fixed on wall complete all as specified & directed by Engr-in-Charge.
S&F in repair fancy type, CP colour powder coated 20/25 mm dia of curtain rod brackets fixed on wall complete all as specified & directed by Engr-in-Charge.
S&F in repair stainless steel peg set assembly for 6 hooks fixing on door or wall with the help of screw complete all as specified & directed by Engr-in-Charge.
S&F 25mm mesh size stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified & directed by Engr-in-Charge.
S&F in repair 25mm mesh size stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified & directed by Engr-in-Charge.
Material & labour for MS hold fast and similar small articles confirming to Fe-290 Gde-E-165 complete all as specified & directed by Engr-in-Charge.
Demolition and breaking up of 100mm dia CI soil/waste pipe including bends, branch pieces set in cement/lime mortar
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified & directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified & directed by Engr-in-Charge.
M&L for uprooting of bushes/scrubs/vegetation from walls of buildings up to extended root and spraying of acid of required quantity complete from any location of buildings up to 4 storied and making good disturbed surfaces with cement mortar (1:4) including necessary scaffolding complete for tree of girth up to 5 to 10 cm & area n. exc 1sq. m complete all as specified & directed by Engr-in-Charge.
M&L for repair of bath room outlet pipe, rain water pipe mouth with the help of chemical component CONBEXTAR GP2 including necessary finishing of surrounding areas matching with existing one complete all as specified & directed by Engr-in-Charge.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing complete all as specified & directed by Engr-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing complete all as specified & directed by Engr-in-Charge.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for re-fixing complete all as specified & directed by Engr-in-Charge.
S&F 20mm outer dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold-water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified & directed by Engr-in-Charge.
S&F 25mm outer dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold-water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified & directed by Engr-in-Charge.
S&F in repair 20mm bore brass MTA/FTA for CPVC pipes complete all as specified and directed
S&F in repair 20mm bore brass elbow complete all as specified and directed
S&F in repair 20mm bore brass Tee complete all as specified and directed
S&F in repair 25mm bore brass MTA/FTA for CPVC pipes complete all as specified and directed
S&F in repair 25mm bore brass elbow complete all as specified and directed
S&F in repair 25mm bore brass Tee complete all as specified and directed
S&F in repairs CP health faucet with CP flexible cord fixed on wall complete all as directed.
S&F angular Stop cock 15 mm dia cast copper alloy chromium plated fancy type with wall flunk concealed type screwed for iron pipe etc. complete all as directed including taking down old unserviceable stop cock complete all as specified & directed by Engr-in-Charge.
S&F in repair fancy type concealed stop cock 15 mm bore cast copper alloy chromium plated fancy type, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union etc complete all as specified & directed by Engr-in-Charge.
S&F in repair 15 mm bore fancy type Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified & directed by Engr-in-Charge.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified & directed by Engr-in-Charge.
S&F vitreous china wash hand basin, oval undercounter base white size 480x400x100mm flat back excluding taps waste chain and plug and porcelain stopper cutting for pinning in ends erecting stand but exclusive of fixing of supply and waste pipe complete all as specified & directed by Engr-in-Charge.
S&F 32mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified & directed by Engr-in-Charge
S&F in repair CP grating except traps for 100mm diameter of outlet including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified & directed by Engr-in-Charge
S&F in repair brass chromium plated shower rose 125mm with having arm length 450 mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed by Engr-in-Charge
S&F in repair 3-in-1 Brass CP mixer for mixing hot & cold-water supply with telephonic shower arrangement, cast copper alloy chromium plated fancy type, screwed down for 15mm bore iron pipe and fixed complete all as specified & directed by Engr-in-Charge
S&F in repair brass CP mixer for mixing hot & cold water for water supply basin screwed down for 15mm bore iron pipe and fixed complete all as specified & directed by Engr-in-Charge
S&F in repair two-way bib cock 15 mm bore with flange, cast copper alloy chromium plated fancy type screwed for iron pipe complete all as specified & directed by Engr-in-Charge
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and making good disturbed surfaces with concrete as per existing one complete all as specified & directed by Engr-in-Charge
S&F in repair plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed by Engr-in-Charge
S&F in repair CP towel ring of size 150mm decorative type fixed with walls complete all as specified & directed by Engr-in-Charge
S&F in repair PVC bathroom cabinet box of size 500x400mm fixed on walls complete all as specified & directed by Engr-in-Charge
S&F in repair PVC 10 litres capacity valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and 32 mm bore including flush pipe connections complete all as specified & directed by Engr-in-Charge
S&F in repair CP connections for hot water supply having length 450mm, fixed to 15 mm GI pipe complete all as specified & directed by Engr-in-Charge
S&F in repair soap dish, vitreous china white, approximate size 160x 160x90mm, fixed to plugs with chromium plated brass screws complete all as specified & directed by Engr-in-Charge
S&F in repair stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchenor laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm & waste pipe complete all as specified & directed by Engr-in-Charge
S&F in repair 32mm waste coupling of PTMT (half or full threaded & minimum weight 45gms) for stainless steel sink complete all as specified & directed by Engr-in-Charge
S&F in repair stainless steel kitchen plate rack made out of 1.00mm thick sheet for size 786x914x254mm fixed on wall with screw, washers complete all as specified & directed by Engr-in-Charge
S&F in repair 15 mm bore stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90gms) complete all as specified & directed by Engr-in-Charge
S&F in repair 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed. (Minimum weight 455gms) complete all as specified & directed by Engr-in-Charge
S&F in repair 15 mm bore bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified & directed by Engr-in-Charge
S&F in repair 40 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified & directed by Engr-in-Charge
S&F & hoisting in position rotational moulded polyethylene water storage tanks 2000 litres capacity (cylindrical vertical with closed top) hoisted and provision of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) after dismantling non-functional/defective water tank complete all as specified & directed by Engr-in-Charge
Taking down existing false ceiling and providing and fixing 6mm thick fibre board fixed anodised aluminium snap grid framework false ceiling with screws as per manufacturer’s instructions and anodised aluminium snap grid framework made of Hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long after dismantling the existing one complete all as specified & directed by Engr-in-Charge
S&F in repair 40 mm bore medium grade galvanised tubes with all fitting and fixed complete to walls & ceiling with necessary holding clamps of false ceiling complete all as specified & directed by Engr-in-Charge
Dismantling mild steel work of any description not otherwise provided for complete all as specified & directed by Engr-in-Charge
S&F for providing mild steel (Gde-E-165) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting including riveting/welding fixing screws, bolts, etc.as desired complete all as specified & directed by Engr-in-Charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws as specified complete all as specified & directed by Engr-in-Charge after dismantling the old CGI sheet
Dismantling structural steel work of any description not otherwise provided for complete all as specified & directed by Engr-in-Charge
S&F & hoisting in position joist, channel, angle or tee secs fixed independently without connecting plates etc. and similar work conforming to Fe-410W (Gde-E-250) complete all as specified & directed by Engr-in-Charge
S&F & hoisting in position roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc. having Fe-410W (Gde-E-250) complete all as specified & directed by Engr-in-Charge.
Material & labour for construction of twenty numbers Modular Kitchen having with upper & lower cabinet cabinet consist of following items & size of each individual modular kitchen will be as per site condition, contractor deemed to have quoted their rate accordingly & no extra claim will be entertained afterwards and all as directed by the Eng-in-charge
Supply & fix 18/19 mm thick post forming both side prelaminated pvc moulded solid kitchen cabinet boxes with shelf, drawer and shutter full size fitted under the kitchen cooking plateform and other plateform incl fittings including provision of fixing arrangement complete all as specified & directed by Engr-in-Charge.
Supply & fix 12 mm thick post forming both side prelaminated pvc moulded solid kitchen cabinet boxes with shelf, drawer and shutter full size fitted under the kitchen cooking plateform and other plateform incl fittings including provision of fixing arrangement complete all as specified & directed by Engr-in-Charge.
Supply & fix modular auto concealed soft closing hinges 35mm 110 degree size complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel handle 200mm long complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel handle 150mm long complete all as specified & directed by Engr-in-Charge.
Supply & fix PVC tape 18mm wide with adhesive complete all as specified & directed by Engr-in-Charge.
Supply & fix multipurpose basket of stainless steel of grade 304 of having size 470X535X150mm complete all as specified & directed by Engr-in-Charge.
Supply & fix perforated stainless steel of grade 304 cutlary of having size 470X485X350mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 grain trolly having base size 450X500X300mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 three tier trolley bottle pull out having size 485X530X150mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 bottle pull out having size 150X485X430mm with two shelf complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 cup & soucer basket of having size 470X535X100mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 plate basket of having size 470X535X200mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 cylinder trolly complete all as specified & directed by Engr-in-Charge.
Supply & fix bin holder stainless steel of grade 304 complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 detergent holder of having size 254X152X279mm complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 telescopic drawer channel rollers for shelves of size 500mm long complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 telescopic drawer channel rollers for shelves of size 350mm long complete all as specified & directed by Engr-in-Charge.
Supply & fix stainless steel of grade 304 glass tray & plate tray 610mm long complete all as specified & directed by Engr-in-Charge.
Internal Electrification
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces complete all as specified & directed by Engineer-in-Charge.
Material and Labour point wiring (Concealed in walls, ceiling etc) with 1.5 Sq. mm (nominal area), FRLSH PVC insulated, multi-stranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits with all fittings and accessories like Tee, bend etc. complete and including 1.5 Sq. mm (nominal area) FRLSH PVC insulated, unsheathed, multi stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point complete for one light/fan/bell/buzzer point/ 3 pin 5 Amps socket outlet independent point controlled by one, one way switches complete including cutting, chasing the surface and then making good the disturb surfaces in CM 1:3 complete all as specified and directed by the Engr-in-Charge. Note: Flush metal GI boxes for fixing of modular switches/sockets will be measured & paid in respective item of work mentioned here in after.
All as per item No.134.02 here-in-before but for one 3 pin 5 amp switch socket out let independent complete all as specified and directed by the Engr-in-Charge.
All as per item No.134.02 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch with PVC conduit complete 1.5 Sq. mm multi-stranded complete all as specified and directed by the Engr-in-Charge.
All as per item No.134.02 here-in-before but using 2.5 Sq. mm size stranded copper conductor cable for one 16 Amp switch 2.5 Sq. mm for socket outlet point on independent board complete PVC insulated and 2.5 Sq. mm unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by the Engr-in-Charge
All as per item No. 134.02 here in before but using 1.5 Sq. mm for 2 way point wiring to be provided in staircase complete all as specified and directed by the Engr-in-Charge.
All as per item No. 134.02 here in before but using 4 Sq. mm for AC starters point wiring and providing 4.0 Sq. mm unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular switch 2 way 6A, 1 module complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular switch 1 way 6A, 1 module complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular Switch socket outlet 3 pin 6 amp' flush type on independent board complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular Socket, 6A - 2/3 pin combined 2 module on the same board with other switch complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular Bell push 6A 1 module complete all as specified and directed by the Engr-in-Charge.
Supply & fix call Bell, AC, 230 volts, single pole complete all as specified and directed by the Engr-in-Charge.
Supply & fix Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed by the Engr-in-Charge.
Supply & fix Fan step regulator, 120W - 2 modules complete all as specified and directed by the Engr-in-Charge.
Supply and fixing of energy efficient LED fittings of capacity 10 W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one meter in length including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fixing of energy efficient LED fittings of capacity 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one meter in length including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fixing LED fittings with lamps of 35 watts for bldg security light IP 66 power Coated pressure die cast aluminum compact high power LED street light with compact size & rough design 32 mm GI Bend including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fixing energy efficient LED bed side light 3watt flexible gooseneck with premium material white including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fixing in LED mirror light 7 watt design including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fixing in LED garden light 9watt pedestal lantern design including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: - light fittings should not be less than 110 lumen per watt
Supply and fix A C starter unit, consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top including taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing sub main wiring with two run of single core 10 Sq. mm PVC insulated unsheathed stranded cable copper conductor drawn through PVC conduits (Not less than 32mm dia) concealed in walls, ceiling etc with all fittings and accessories like Tee, bend etc. complete fixed to walls/ceiling etc. including 10 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC conduit of appropriate size including taking down old one complete all as specified and directed by the Engr-in-Charge. Note : Two run of single core cable 10 sq mm and one run earth wire 10 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 6 Sq. mm PVC insulated unsheathed stranded cable copper conductor drawn through PVC conduits (Not less than 25mm dia) concealed in walls, ceiling etc with all fittings and accessories like Tee, bend etc. complete fixed to walls/ceiling etc. including 6 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC conduit of appropriate size including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: Two run of single core cable 6 sq mm and one run earth wire 6 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 4 Sq. mm PVC insulated unsheathed stranded cable copper conductor drawn through PVC conduits (Not less than 25mm dia) concealed in walls, ceiling etc with all fittings and accessories like Tee, bend etc. complete fixed to walls/ceiling etc. including 4 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC conduit of appropriate size including taking down old one complete all as specified and directed by the Engr-in-Charge. Note: Two run of single core cable 4 sq mm and one run earth wire 4 sq mm will be measured as one length.
Taking down unserviceable rusted / damaged MCB DBs of any type and having with any type MCB and return to MES store Yard for further incorporation in the work including making good distubed surfaces of walls etc. matching with existing one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing sheet metal powder coated double door enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar including connection after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing sheet metal double door powder coated enclosure for DB's when MCBs to be used 6 way single pole and neutral double door with 200 amps rated bus bar including connection after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing MCB 6 to 32 Amps, SP, 240 Volts, C- Curve breaking capacity 10 KA after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing MCB 32 Amps, DP 240 Volts, C- Curve, breaking capacity 10 KA after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing MCB TPN DB made up with sheet metal double door, phosphoresced, power coated, neutral link, earth bar and din rail, 6 way TPN with 200 amps rated bus bar, 415 volts after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply and fixing FP 63 Amps, 415 Volts, C- Curve breaking capacity 10 KA after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix ceiling fan complete with blades, down rods, electronic regulator and accessories 230V, 1200 mm sweep min air delivery 210 CFM 6 BEE BLDC complete all as specified and directed by the Engr-in-Charge.
Supply & fix exhaust fan AC single phase 240 V 300 mm sweep with louvers plastic body and blade complete all as specified and directed by the Engr-in-Charge.
Materials and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip protected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanized iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal of soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 of MES Schedule Part-I complete all as specified and as directed.
Taking down and re-fixing Energy meters of any type/capacity after necessary repair complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 1 Module/ 2 Module after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 3 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 4 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 6 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 8 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls for 12 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 1/2 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 3 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 4 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 6 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 8 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix modular cover plate with frame for fixing of modular switches/sockets complete for 12 modules after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix RCCBs for earth leakage protection, 40 Amp, double pole 30A for protecting life and equipment after taking down old one complete all as specified and directed by the Engr-in-Charge.
Supply & fix electric water heater storage type steel body with coper inner tank and heating element uto 2 KW 25 Lt Capacity BEE 5 star with all accesorries complete all as specified and directed by the Engr-in-Charge.
External Electric Supply
Materials and Labour cutting existing road/path, hard standing etc for taking out cable including cable protection pipe and making good the disturbed road top surfaces with following cement concrete up to a suitable depth and finished with speed breaker complete all as specified & directed by Engineer-in-Charge.Note: Entire concreting work will be measured under respective item of work as specified under external water supply schedule
Taking out unserviceable UG cables of any type and any sizes from trenches/wall etc and removing from the site of work complete all as specified & directed by Engineer-in-Charge.Note: - (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of work as specified under external water supply schedule
Supply and laying dry coarse sand as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified & directed by Engineer-in-Charge.
Laying only old size bricks obtained during excavation of cable and laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified & directed by Engineer-in-Charge.
Supply and laying of bricks, sub class 'B' (kiln burnt) old size bricks in trenches, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified & directed by Engineer-in-Charge.
Supply and laying 3.5 core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, sec. area 400 sq. mm running through trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified & directed by Engineer-in-Charge.
Supply and laying 3.5 core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, sec. area 150 sq. mm running through trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified & directed by Engineer-in-Charge.
Supply and laying in trenches 80mm bore light grade GI pipe with all fittings complete all as specified & directed by Engineer-in-Charge.
Supply, installation testing and commissioning bldg main panel board CPRI approved type tested IEC 61439 part 1 & 2 type tested panel of size 1.50 mtr X 1.10 mtr X 0.800mtr outdoor type confirming to IP-54, factory made double door both front and back side, with locking arrangement prewired made out of 3.15mm thick MS sheet with 04 Nos legs, MS angle iron 40x40x6mm size 0.6mtr long suitable for floor mounted in ground with PCC 1:3:6 type C2 and cement plaster 1:4 including two coats or synthetic enamel paint over a coat of red oxide primer both internally & externally and including provision of aluminium bus bar 900 amps rated duly coloured coded 04 Nos and connection through aluminium bus bar of suitable size of MCBs, MCCBs and power contactor and accessories fitted with incoming and outgoing cable, including LCD multi function meter for measuring voltage ampere frequency, KW, KWH, Phase indicating lamps LED type RYB duly fitted in Panel and all the accessories to be connected with suitable copper conductor (control wiring) and power connection with bus bar including connection of cable with necessary lugs, glands etc. complete after taking down old unserviceable panel board and electric connection complete all as specified & directed by Engineer-in-Charge.
List of accessories are as under: -
(i) MCCB, 630 Amps, 4 pole, 415 volt, 50 KA fixed thermal and magnetic setting – 01 No (incoming).
(ii) MCCB, 250 Amps, 4 pole, 415 volt, 36 KA fixed thermal and magnetic setting – 05 Nos (04 outgoing and 01 spare).
(iii) MCB 32 Amp FP B curve- 01 Nos (outgoing).
(iv) LCD Multifunction meter with CT -1No
(v) Phase indicating Lamps LED type RYB complete – 01 Set
(vi) Modular contactor 40A-3 NO, 3 module make L&T cat no AUMC3004003 -1 No Note-: Contractor must proceed with work only after obtaining approval of manufacturer from GE supported with drawings as catered herein in particular.
Materials and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip protected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanized iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal of soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Lighting Protection
Material & labour for providing Galvanized strip 32 x 6 mm with saddles and fixing screws etc. for roof conductor and down conductors above ground buried in ground/fixed on wall ,roof with saddles and fixing screws etc., for roof conductors and down conductors above ground after taking down old unserviceable electric connection complete all as specified & directed by the Eng-in-charge.
Material & labour for providing Air termination, single pointed Al rod 12mm dia and 300mm long after taking down old unserviceable electric connection complete all as specified & directed by the Eng-in-charge.
Material & labour for providing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including 3nos 8mm dia 25mm long hexagonal head screw after taking down old unserviceable electric connection complete all as specified & directed by the Eng-in-charge.
External water Supply
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for water supply pipe line/UG cable n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by the Eng-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified & directed by the Eng-in-Charge.
Removing excavated material (Soils of any type) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed by the Eng-in-Charge.
Material & labour cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded stone aggregates) as in foundation base of poles and other similar locations after demolition of existing one complete all as specified & directed by the Eng-in-Charge.
Taking out 50mm bore existing pipe line any type from trenches, walls, floors etc including cleaning for re-fixing or removal of unserviceable pipe from site complete all as specified & directed by the Eng-in-Charge.
Taking out 40mm bore existing pipe line any type from trenches, walls, floors etc including cleaning for re-fixing or removal of unserviceable pipe from site complete all as specified & directed by the Eng-in-Charge.
Taking out 25mm bore existing pipe line any type from trenches, walls, floors etc including cleaning for re-fixing or removal of unserviceable pipe from site complete all as specified & directed by the Eng-in-Charge.
Supply and laying 50mm bore tubes, ‘Medium Grade', galvanized, with all fitting; laid in trenches complete all as specified & directed by the Eng-in-Charge.
Supply and laying 40mm bore tubes, ‘Medium Grade', galvanized, with all fitting; laid in trenches complete all as specified & directed by the Eng-in-Charge.
Supply and laying 25mm bore tubes, ‘Medium Grade', galvanized, with all fitting; laid in trenches complete all as specified & directed by the Eng-in-Charge.
Supply & fixing 50mm bore Gun-metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, after taking down the old unserviceable one complete all as specified & directed by the Eng-in-Charge.
Supply & fixing 40mm bore Gun-metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, after taking down the old unserviceable one complete all as specified & directed by the Eng-in-Charge.
Supply & fixing 25mm bore Gun-metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, after taking down the old unserviceable one complete all as specified & directed by the Eng-in-Charge.
Materials and Labour for construction of brick masonry valve pit chamber of size 1050x1050x1050mm internal dimension using sub class-'B' bricks in CM (1:6) plastering in cement mortar (1:4) externally & internally extended to 15 cm below ground level including PCC bed 10 cm thick in PCC 1:3:6 Type C2 with MS frame fabricated by angle of size 40 x 40 x 6mm complete with top cover of 3 mm thick MS sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer including demolition of old unserviceable damaged valve pit complete all as specified & directed by the Eng-in-Charge.
NIRMAL SALES CORPORATION
DNS CONSTRUCTION COMPANY
Shree Mahabir Builders
Hindustan Traders
M/s KUMAR BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .