Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC SAINIK SOCIETY HITKARINI DENTAL COLLEGE DUMNA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹49.6 L+₹4.2 L (9.31%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 3 | L3₹50.7 L+₹5.3 L (11.7%)Rejected-Finance VILL BUD BUD PO BUD BUD PS BUD BUD DIST PURBA BARDHAMAN PIN 713 403 WB | BUD BUD | PURBA BARDHAMAN | WEST BENGAL | 713403 | L3 | Rejected-Finance HIGHER RATE QUOTED THAN L1 |
Tender Value
₹46.2 L
EMD Value
₹92,500
Closing Date
4 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2024_MES_682428_1
8500-191/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per Tender documents
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹92,500
Yes
20 Jan 2025
5 Nov 2024
5 Dec 2024
5 Nov 2024
4 Dec 2024
20 Nov 2024
Amount
Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Surface dressing n exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in in soft/loose soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
All as per BOQ Item No 3.00 here-in-before but for getting out in hard/dense soil complete all as specified and as directed.
M&L for Excavating over areas, n exc 1.5 m deep and getting out in soft loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum and getting out and removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge exc 63mm but n.exc 75 mm deposited, spread & leveled in lyers n.exc 15 cm thick watered & rammed to a true surface complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm graded stone aggregate Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm graded stone aggregate as in chajjas complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm graded stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm graded stone aggregate Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20 mm graded aggregate) as in bed blocks for hold fast including necesssary formwork, kerb stones etc complete all as specified and directed.
M&L for Cement Concrete,1:2:4, type B1 (using 20mm graded aggregate) as in bed block, coping, lintel upto 1.50 m span, cills, kerbs etc complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20mm stone aggregate as in precast manhole cover slabs set in CM (1:6) complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed. Makes : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for Use and Waste of Formwork (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete, flat all as specified and directed.
M&L for Use and Waste of Formwork (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items in?cluding ege for fair finished surface of concreted complete all as specified and directed.
M&L for Use and Waste of Formwork (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface of concrete complete all as specified and directed.
M&L for Use and Waste of Formwork (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F rolled mild steel in plates channel (plain or chequred) square cut or notched (ordinary and counter shunk)forming holes, withpout any attachment of quality FE 410-W (Gde-E-250)quality-A complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410- W(Gde- E-250) quality-B. complete all as specified and directed.
S&F mild steel for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410- W(Gde- E-250) quality-B complete all as specified and directed
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; and similar work conforming to Fe.290.Gde-E-165 the grill shal be inseted in the wall surface including neceasary drilling and grouting with cement etccomplete all as specified and directed.
M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified at any height including all necessary scaffolding and safety measures complete all as specified and directed
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazinjg bars, dovetailed or welded, including one shop coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:6) complete all as specified and directed.
M&L for 15mm thick in CM 1:4 rendering on brick or concrete surfaces mixed with water proofing compound as per manufactures instructions, surface finished fair and even all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even and smooth on walls in cement mortar (1:4), complete all as specified and directed.
M&L for 15mm thick in cement plaster CM (1:6) on brick or concrete surfaces finished fair and even without using extra cement on wall complete all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on ceiling finished fair and even without using extra cement etc complete complete all as specified and directed.
M&L for 10mm thick in CM (1:6) rendering on brick or concrete surfaces finished even and smooth with integral water proofing compound on wall complete all as specified and directed.
M&L for 10 mm thick in CM (1:4) rendering on brick or concrete surfaces mixed with water proofing compound as per manufactures instructions, surface finished fair and even all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for preparation new surface of roof and applying two coat of polyurethene (PU) acrylic based water proofing liquid compound over & including one coat of self priming primer @one litre per ten sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage /seepage from roof/wall complete all as specified and directed by the Engineer-in-Charge (notes- 1.as per description of the items minimum two coats of polyurethene (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out by the as per manufacture instruction.pl note no price adjustment shall be made,if more coats of (PU)acrlic based water proofing liquid compound & primer are required for roof treatment. 2. quated rate shall be deemed to be included for work in building/structure of any height.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel will be wire mesh in lieu WPC, the wire gauze shall be warped on additional square 8mm MS Solid tube and this tube shall be welded to MS frame complete all as specified and as directed.
S&F 150mm long extruded Aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F Aluminium alloy, 300 mm long anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100 mm size B21 complete all as specified and directed.
S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F Wire netting of stainless steel wire 0,91mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified and directed.
S&F sheet glass 4.8/5 mm thick, ordinary quality and glazing with beads fixed with metal panel pin in square n exc 0.5 Sqm each complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in hardstanding laid in panels with and including use and waste of formwork and to divide the area in panels and finishing the surface even and fair complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in hardstanding laid in panels with and including use and waste of formwork and to divide the area in panels and finishing the surface even and fair complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in Sub base or base course finished even annd fair complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and smooth with out using extra cement complete all as specified and directed.
M&L for cement concrete type B1 (1:2:4) with nominal reiforcement using 20mm graded aggregate 75 mm thick as in floor finished even and rough complete all as specified and directed. (Note:- Reinforcement will be measured and paid separately)
M&L for Virified Ceramic tiles light shade 7-8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. set and including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry & pointed with grout of matching shade complete all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed.
M&L for preparation of new surfaces of plastered walls and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including a coat of primer over and including wall care putty (2.0 mm thick) complete at any height including all necessary scaffolding and safety measures complete all as specified and directed.
All as per BOQ Srl Item No 60 here-in-before but on ceiling surface complete all as specified and directed. .
M&L for complete removal of existing treatment and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including a coat of primer at any height including all necessary scaffolding and safety measures preparion of old plastered surfaces of walls complete all as specified and directed.
All as oer BOQ Srl Item No 62 here-in-before but on ceiling surface complete all as specified and directed.
M&L for preparation of new surface and apply Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior alkali resistance primer applied @ 0.90 litre/ 10 sqm over new surface over 1 mm thick putty complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces and as all specified complete all as specified and directed.
M&L for Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg per sqm per coat complete all as specified and directed
M&L for Forming 12mm thick Expansion joints for 100 mm thic filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A complete all as specified and directed’
M&L for 300 mm thick Kankar or laterite, spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
M&L for 200 mm thick klinker or laterite, Shingle filling in floors or pavings, laid in layers 100mm thick each , spread, levelled, and blinded with earth and rammed including watering complete all as specified and directed.
M&L for 150mm bore,HDPE double wall corrugated(DWC) SN-8 PIPE (HDPE Black Pipe) WITH COUPLER Conforming to IS:16098 Part-II:2013 sewage pipes laid in trenches and jointed as per manufacturer,s instruction with and including all fitting complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes of 150 mm bore including cradle after they are laid and tested; including necessary form work complete all as specified and as directed.
Cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smoorth finished and reforming benching as required for 150mm internal dia of pipe complete all as specified and as directed.
M&F of (DWC) structured wall polyethlene coupler/elbow 90/elbow 45/ end plug/reducer for piping system with non smooth external annular corrugated and smooth internal surface (Double Wall) for non presure sewage & drainage application pipes of standard length 6m, grade conforming to IS 16098 (part-II:2013) Stiffness Class SN-8 inner dia 150mm(tolerance limit plus& minus 2mm) anti rodent pipes laid in trenches all as specified and directed.
M&L for on site conventional type LLDPE septic tank 10 user capacity designed to carry sewage and sullage water including all necessary excavation and earh work in any type of soil, PCC 1:4:8 type D2 lean concrete as in foundation ,vent shaft and making necessary connection etc, complete all as specified and as directed by the Engr-in-charge.
M&L for construction of Soak Well of size 1.2 m dia and 1.5 m effective depth, including all necessary excavation & earth work in any type of soil, PCC 1:3:6, type C-2(using 40 mm graded stone aggregate) lean concrete in foundation,walls of honey combed masonry 375mm thick , RCC cover slab and precast RCC/SFRC manhole cove in concrete of grade M-25, inlet and outlet pipe, PVC vent pipe & cowl complete all as specified and as per drawing No CZ/TD/464(R) dated 28/05/2005. (depth and dia of soak well shall be ammended accordingly, rest all as per drawing)
E/M PORTION M&L for concealed point wiring for sheet metal enclosure 20/25 amp two pin and earth plug complete with 4.0 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC FRLSH insulated 4.0 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly. Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
M&L for concealed point wiring for fan/light point controlled by one one way switch complete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly and including pressed steel terminal flush boxes made out of 1.6 mm thick MS sheet suitable for modular switches concealed in wall with and including modular cover plate with frame of suitable module for housing the switches socket,outlet etc.,all as specified and directed by Engineer-in-Charge for one light point controled by one one way 5/6 Amp switch Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface, modular cover plate, box and frame are deemed to be included in the quoted rate.
All as per Item No. 77.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.50 Sqmm for one socket point of 3 pin 5 Amps on same board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.50 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per Item No. 77.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.50 Sqmm for one socket point of 3 pin 5 Amps on independent board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.50 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per Item No. 77.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 4.0 Sqmm for one power point of 3 pin 5 Amps on independent board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 4.0 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
S&F switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet modular type 6 Amp 2/3 pin combination , two module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F switch modular type 16/20 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet modular type 6/16 Amp 2/3 pin combination , two module, single phase, complete all as specified and directed by Engineer-in-charge.
M&L for Switch socket combination 5 in 1, 5A/16A, flush type universal incl GI box complete all as specified and as directed.
S&F ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified by Engr-in-Charge
S&F in repair 6 watt resseced type with GI box surface mounted round LED Down light colour (CW) aesthetically designed made by aluminium P-die-cast enclousers, with separate replaceable constant current driver 6 watts for grid ceilling including electrical connection all as directed by Engr-in-Charge
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 25000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.
S&F LED light fitting 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable complete all as specified & directed.
S&F LED security light 35 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 25000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen
S&F surface type sub main /circuit wiring with two run of 2.5 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn into and including 2 non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc., fixed on wall/ceiling with GI saddles, SS screws, rawl plugs etc. including one run of 4.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length.
S&F concealed type sub main wiring with two run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 25 mm including one run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit and one run of cutting chases shall be measured as unit length. (ii) Cost of PVC conduit, conductors, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
S&F concealed type sub main wiring with two run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 25 mm including one run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit and one run of cutting chases shall be measured as unit length. (ii) Cost of PVC conduit, conductors, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
S&F sheet metal enclosure with 20 Amp MCB and two pin and earth plug and socket complete with one single pole MCB all as specified By Engr-in-Charge.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 12 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
S&Fin repairs MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
S&F 63 Amp MCCB 4 pole, 3 phase, 415 volt of capacity Amp, 16 KA complete with proper copper thimbles, copper reducer etc complete all as specified and directed.
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 2 core 10 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etccomplete all as specified and directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted/Punned thickness shall be measured).
M&L for burnt clay fly ash bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.
S&F GI Light grade 40 mm dia of size for road cross/cutting on wall floor drain etc complete all as specified and as directed.
Supply and laying of pipe GI medium grade 15 mm dia complete in wall ceiling or floor etc complete all as specified and as directed.
Drilling / tapping or cutting cast iron/ GI water mains (in position) for branch connections of the internal dia 15 mm complete all as specified and as directed.
S&F Stop valve 15mm fancy type CP cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and as directed.
Supply and installed voltage stabilizer 17.39 to 18.00 Amp capacity, wall mounting type for automatic operation, single phase, digital display, naturally air cooled indoor type and designed for input variation between 130 V to 280 with out put voltage stabilized at 200 V to 230 V accuracy of + 2.0%, copper wound complete all as specified
All as as BOQ Srl Item No 109.00 here-in-before but of capacity 13.04 to 13.63 Amps complete all as specified and directed.
Supply, installation, commissioning and testing of Single Door Refrigerator of capacity 250- 300 Ltrs or more, BEE 5 star , electric driven (single phase), capacity 2 complete all as specified and as directed
Supply, Installation, testing and commisioning of split type Air Conditioner of capacity 1.5 TR with hermitically sealed unit complete with dual system i.e cooling and with PCB and remote operationon (R-32 refrigerant) built in air ioniser and plasma filter for better indoor air quality, electric driven suitable for working on 230 Volt, single phase, 50 Hz supply, (3 STAR rating inverter type, ISEER > 3.2) complete incl providing required copper piping, insulation etc cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed.
Supply, assembling, hanging of BLDC (Without remote) ceiling fan, BEE 5 star rated,1200 mm sweep size, min air flow 220 Cu.m/min, 230 volts, AC, 50 Hz, service Value > 6.0. single phase, including provisioning of cord flexible copper 3 core of size 23/ 0.0076 of required length not exceeding 1.5 metre from ceiling rose or connector to ceiling fan for giving electric connection complete all as specified and directed by Engineer-in-Charge.
Supply install necessary connection and testing of water cooler electric driven (single phage), having approx storage capacity 120 Litre and nominal cooling capacity of 60 litre per hour, panel body mase out of SS-304, complete all as specified and directed by the Engineer-in- Charge.
M&L for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire of size 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 15 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protection GI pipe and watering pipe including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of earth lead including protection pipe, from top of earth plate upto 7.5 meter, above/below ground level is deemed to be included in the unit rate. 4. All the joints in earth lead and connection with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
All as per BOQ Item No 115.00 here-in-before but for copper earthing with using copper electrode of size 600 x 600 x 3mm connected to copper strip of size 25 x 3 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 32 mm dia GI pipe (light grade) complete all as specified and directed.
M/S S M ENTERPRISE (BID ID -3180842)
SANJAY KUMAR SUPAN (BID ID -3180913)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .