| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.7 LAccepted-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹53.1 L+₹1.2 L (2.36%)Rejected-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | S A S NAGAR | PUNJAB | 160059 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹55.4 L+₹3.6 L (6.90%)Rejected-AOC 19192 STREET NO 8 BIBI WALA ROAD OPPOSITE DAV COLLEGE BATHINDA PUNJAB PIN 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹55.7 L+₹3.8 L (7.33%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹58.8 L+₹7.0 L (13.4%)Rejected-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
Closing Date
28 Dec 2022, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160 003
SPECIAL REPAIRS TO BUILDING NO P-8/1 (PHASE II) AT AF STATION CHANDIGARH
2022_MES_560221_1
CWE/AF CHD/CHD/T-34/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Chandigarh
Exempted
17 Feb 2023
28 Oct 2022
4 Jan 2023
28 Oct 2022
28 Dec 2022
14 Dec 2022
Amount
Building Work
Taking down cement plaster on brick or stone walls or concrete surfaces, etc, any description including raking out joints, hacking for key, scrubbing down with water, etc and removal of rubbish outside MoD land, complete all as specified and directed. Note : Rate quoted by contractor shall be deemed to include necessary scaffolding etc.
Material and labour for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and directed. Note: The rate quoted by contractor shall be deemed to include cost of necessary scaffolding.
Material and labour for rendering 10 mm thick in cement mortar (1:3), on ceiling, finished even smooth without using extra cement , complete all as specified and directed.
Material and labour for rendering 15mm thick in cement mortar (1:4), using water proofing compound as per manufacturer's instructions, on brick/concrete surfaces of walls, finished even fair , complete all as specified and directed. Note :- 1. Supply only water proofing compound will be measured and paid for separately.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of 1st quality oil bound distemper (oil emulsion) over and including a coat of alkali resistant primer, complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of cement based paint, complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of of ceiling and applying two coats of white wash complete all as specified and as directed.
Material and labour for complete removal of existing treatment on wall and applying two coats of first quality distemper oil emulsion, over and including a coat of alkali resistant primer, complete all as specified and as directed.
Material and labour for preparation of old surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed.
Material and labour for complete removal of existing treatment on ceiling and applying two coats of white wash, complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame), not exceeding 1.5 Sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame), exceeding 1.5 sqm but not exceeding 4 sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Supply and fixing factory made pressed steel frames for doors with two rebates, of size 125mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc,including back filling of PCC1:3:6 type C-0, and one shop cot of primer, complete all as specified and directed.
Supply and fixing factory made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face , supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed.
Supply and fixing factory made 2nd class hardwood, glazed and skeleton shutters, 35mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed. Note:- Wire cloth shall be mesured and paid separately.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S. Square tube, as per specification & drawing in SSR Part-II, in opening, complete all as specified and directed.
Supply and fixing in the frame at site, factory made solid PVC panel door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing in SSR Part-II, complete all as specified and directed.
Supply and fixing Factory made box type steel window with pintol hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handles and with glazing bars, dovetailed or welded in glazed shutter and without glazing bars for wire gauged shutter , including provision of grill, all as per drawing and with one shop coat of zinc chromate primer, complete all as specified and shown on Drawing No CEAF/STD-184-2012 Sheets 1/3, 2/3 & 3/3. Note:- Sheet glass and wire cloth will be measured and paid separately.
Supply and fixing factory made box type steel secion ventilators, fixed type with glazing bars and with one shop coat of zinc cromate primer complete all as specified and and directed.
Supply and fixing sheet glass 4mm thick, ordinary quality and glazing with oil putty or wooden beads in square n exc 0.5 sq. m in each pane, including one coat of syntetic enamel paint to match to existing surfaces,complete all as specified and directed.
Supply and fixing stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed to steel frames with stainless steel tacks, or stainless steel wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed.
Supply and fixing 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21, complete all as specified and directed.
Supply and fixing 200 mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and directed.
Supply and fixing 150mm long, extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and directed.
Supply and fixing Aluminium alloy, anodised, sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed.
Supply and fixing 300mm long ordinary rat tail rod pattern MS door springs including roller and roller plate, complete all as specified and directed.
Supply and fixing in repairs Tublar Towel rail 20mm dia, brass chromium plated, with brackets, fixed to walls with steel screws and plastic cleats, complete all as specified and directed.
Supply and fixing 140 mm door stopper of aluminium alloy body and tongue , anodised, with hard drawn steel spring fixed in door, complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removal of debries out of defence land complete all as specified and directed.
Material and labour for Non skid jointless coloured ceramic tiles 7 to 8 mm thick (square/rectangular ) area each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in C:M 1:4 complete all as specified and directed.
Material and labour for first quality glazed printed pattern coloured glazed ceramic tiles 450mmx300mmx7mm thick fixed in pattern to wall (combination of dark & light colour with border) as in skirting, dado, set and jointed in neat cement slurry, over and including 10 mm thick rendering of cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
Material and labour for light shade double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm,as in skirting, dado and risers to steps etc.set and jointed in neat cement slurry, over and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles. complete all as specified and directed.
Material and labour for light shade double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm,laid over and including 15mm thick screed bedding in cement mortar 1:4 in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specially provided for including removal of debries out of defence land complete all as specified and directed
Material and labour for 75mm thick Plain cement concrete (1:3:6), Type C-2, using 40 mm graded stone aggregate as in plinth protection, finished the surface even and fair, complete all as specified.
Material and labour for 25 mm thick plain cement concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregates as in floor, finished the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed..
Material and labour for 20mm thick Granite black/brown in colour (of any type), (table rubbed and polished), machine cut, as on cooking platforms, window cills, steps and like, set in neat grey cement slurry @ 3Kg/Sqm, laid over and including 15mm thick bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Material and labour for 20 mm thick Granite black/brown in colour (of any type), (table rubbed and polished), machine cut, set in neat grey cement slurry @ 3Kg/Sqm, in skirting/ dado laid over cement plaster in CM 1:4 , 10 mm thick and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, moulding and polishing complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repairs Brass chromium plated shower rose 125 mm size with or without swivel joints, fancy type with CP arm concealed type with CP cup including fixing to steel pipe or union 15mm bore complete all as specified.
Supply and fixing stop valve, cast copper alloy, fancy type, long shank and cup (concealed), chromium plated, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm bore, fixed as in repair, including removal of old to store for reuse or for credit, complete all as specified and directed.
Supply and fixing in repairs vitreous china wash down water closet (pedestal pattern) white pedestal pan and trap, including connection to drain ( or out going pipe ) and to flushing pipe, antisyphonage pipe, with plastic water closet seat cover white , closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device etc, including flush pipe, complete all as specified and directed.
Supply and fixing bib tap, cast copper alloy, fancy type, chromium plated, with capstan head, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm bore dia, fixed as in repair, including removal of old to store for reuse or for credit, complete all as specified and directed.
Material and Labour for Cutting chases in brick work, pinning in making good to facings where required and pointing in cement and sand mortar 1:3 to ends or edges of landings, steps, cills etc and cutting chases for concealed water tubing and making good, cutting not exceeding 10 cm in girth and removal of rubbbish outside MOD land, complete all as specified and directed.
Taking up or down existing steel water tubing and connections, 15mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 15mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, complete all as specified and directed.
Taking up or down existing steel water tubing and connections, 20 mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 20 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, complete all as specified and directed.
Supply and fixing cast iron bends 100mm bore, diminishing pieces or tapers ISI marked, as in repairs, complete all as specified and directed.
Supply and fixing 100 mm dia bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, as in repairs, complete all as specified.
Supply and fixing in repairs 75 mm cast iron floor trap,ISI marked, with mild steel CP grating including jointing to waste pipe, and set in cement concrete 1:2:4 as required, complete all as specified and directed.
Supply and fixing in repairs 75 mm cast iron nahani trap,ISI marked, with mild steel CP grating including jointing to waste pipe, and set in cement concrete 1:2:4 as required, complete all as specified and directed.
Supply and fixing in repairs 100 mm cast iron floor trap,ISI marked, with mild steel CP grating including jointing to waste pipe, and set in cement concrete 1:2:4 as required, complete all as specified and directed.
Supply and fixed in repair, angle stop valves, cast copper alloy, screwed down high pressure, fancy type with capstan head, chromium plated, screwed both ends for iron pipe or for unions, or for brass ferrule 15 mm bore, complete all as specified and directed.
Supply and fixing in repairs PVC connection 15 mm size of length 450 mm with PTMT nuts, complete all as specified and directed.
Supply and fixing 10 litre capacity virgin polypropylene (PVC) low level flushing cistern, ISI marked, white or coloured, valve less symphonic action type, with inlet, ball valve, float and handle, complete including PVC bend/ flush pipe, brackets and making all connections, fixed as in repairs and removal of old from site to store for reuse or credit, complete all as specified and dire
Supply and fixing in repair, vitereous china counter top (self rimming) wash hand basin, white in colour of size 630mm x 500mm including circular cutting and tucked in granite slab, including 15mm dia cast copper alloy chromium plated fancy type single lever basin mixer, 32mm dia brass CP waste fitting and connection to waste pipe and water pipe, complete all as specified and directed. Make: Hindware, Model : RHAPSODY, Cat No : 10045 or equivalent in Cera.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for, in ground floor, Ist floor, in isolated wall/windows, chajjas, balconies, precast cover slab etc and removing rubbish out sie MoD land, complete all as specified and directed.
Material and labour for RCC nominal mix (1:2:4), type B-1, using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like , complete all as specified and directed.
Material & labour for RCC (1:1.5:3) type A-1, using 20mm graded stone aggregate, as in chajjas, fins, louvers, roof projections, beam and lintel after removing loose concrete and preparation of roof surfaces by application of de-rusting chemical such as Dr fixit rust remover or equivalent and welding additional main bars/ distribution bars if found necessary by inserting to adequate depth in beam by drilling, pinning reinforcement old bars/new with including necessary sacafolding and form work as required upto the height 3.5 mtr, complete all as specified and directed. Note:- 1. Rates shall be deemed to include the cost for necessary scafolding etc. 2. Reinforcement will measured and paid separately. 3. Nitozinc primer (FOSROC or equivalent) @ 200ml per Sqm surface area of concrete will be paid in saparate item.
Material & labour for RCC (1:1.5:3) type A-1, using 20mm graded stone aggregate, as in chajjas, fins, louvers, roof projections, beam and lintel after removing loose concrete and preparation of roof surfaces by application of de-rusting chemical such as Dr fixit rust remover or equivalent and welding additional main bars/ distribution bars if found necessary by inserting to adequate depth in beam by drilling, pinning reinforcement old bars/new with including necessary sacafolding and form work as required upto the height exceeding 3.5 mtr and upto height of 7.50 mtr, complete all as specified and directed. Note:- 1. Rates shall be deemed to include the cost for necessary scafolding etc. 2. Reinforcement will measured and paid separately. 3. Nitozinc primer (FOSROC or equivalent) @ 200ml per Sqm surface area of concrete will be paid in saparate item.
Material and labour for TMT steel bars, 8 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Supply only nitozinc anti crrosion primer of M/s FOSROC or equivalent as approved by GE, complete all as specified and as directed.
Material and labour for formwork for flat fair finished surfaces of concrete to sides and soffits of lintels, cantilevers, shelves including supports, overhangs, etc also splay between floors and beam, complete all as specified and directed.
Material and labour for Waterproofing expansion joint tape, Providing and laying Thermoplastic Elastomer tape 1mm x 200 mm, a modified flexible TPE based root resistant membrane with chemical resistance. The tape system must be having tensile strength > 5 N/Sqmm according to ASTM D 412; tear strength > 25 N/Sqmm according to ASTM D 624; elongation > 400 % according to ASTM D 412; chemical resistant; passing low temperature foldability test at -40°C according to ASTM C 1305; passing artificial weathering test according to ASTM G 154. The tape must be capable of withstanding a wide range of temperature of -40°C to +80°C. The tape, adhesive and repair mortar must be provided by same manufacturer for full compatibility. The same shall be applied using epoxy adhesive of layer 2mm to prepared base both sides of joint so both sides of the tape shall be embeded into the adhsive on a width of 38mm, complete all as specified and directed.
Material & labour for Cleaning and preparation of roof (RCC/Brick tiles/Cement concrete) surfaces and made free of dirt, foreign particles, laitance, followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expansion/contraction, and repairing the cracks after making “V” groove with suitable cutter machine, filled with Repair Morter/General Purpose Grout in the proportions as recommended by manufacturer, supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications: (a) Elongation of range 400%-600% (b) Tensile strength of 8-12 N/mm2 (c) Crack bridging ability of 3.00- 4.00 mm (d) Hardness (Shore’A’, ASTM D2240) of range 50-70 The application shall include final base preparation, epoxy primer application in rato 1:1 (resin:hardner) with 100% water dilution and application of Hybrid ployurea in two coats in 6 hrs interval to achieve total min thickness 1 to 1.50 mm. The application/treatment shall be carried out by authorised rep of approved specialist firm/manufacturer. Make- SIKA/FOSROC/Asian Paints/Berger. Note:- The defect liability period of water proofing treatment to RCC roof slab including sunken floors shall be 10 years and the contractor shall be responsible to keep the entire building(s) free from leakage/seepage for a period of 10 years after certified date of completion. The contractor may obtain a similar guarantee from the specialist firm engaged by him for the purpose.
All as per Srl item No 1.68 here-in-before but on vertical surfaces, complete all as specified and directed.
Demolition of brick masonry work built in cement mortar including all quoins, arches, pillars, staging etc. and removal of rubbish outside MOD land, complete all as specified and directed.
Material and labourfor brickwork with using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
Material and labour for brickwork in half brick thick wall using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
Dismantling existing water tanks of size exc 250 Litre but n.exc 500 litre capacity and removal from site to store for reuse or credit, complete all as specified and directed.
Dismantling existing water tanks of size exc 500 Litre but n.exc 1000 litre capacity and removal from site to store for reuse or credit, complete all as specified and directed.
Supply and fixing/hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 500 litres capacity ‘triple layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug, complete all as specified and directed.
Supply and fixing/hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 1000 litres capacity ‘triple layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug, complete all as specified and directed.
Supply and fixing in repairs 20 mm ball valves (Minimum weight 210 gms) high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
Demolition of lime concrete/lean concrete/brick bats from sunken portion exc. 15cm thickness (above ground level) including removal of rubbish out side of MOD land, complete all as specified and directed.
Water proofing treatment to sunken portion of WCs, bathroom etc. by applying coating of cement slurry mixed with Acrylic based polymer modified cementitious composite compound of make as approved inTechnical instruction 5/ 2003 as detailed hereunder:- (a) Applying 15 mm thick plaster (1:4) in cement sand mortar with integral water proofing compound 2% by weight of cement on floor and wall, finishing the surfaces even and smooth wiithout using extra cement. The surface shall then be cured and allowed to dry. (b) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
Material and labour for providing cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregates including integral water proofing compound as per manufacturer's instructions, as in padding in sunken portion of floor slab, coving to junction of floor and vertical walls, including chamfering on edges, finishing the surface fair and even without using extra cement, complete all as specified and directed. Note:- Supply only integral water proofing compound will be measured and paid for separately.
Material and labour for lime concrete with 40 mm graded brick aggregate with lime mortar 1:2 as in sunken portion of floor, complete all as specified and directed.
Dismantling cast iron work of any description not otherwise provided for, and removing to store for reuse or credit, complete all as specified and directed.
Supply and fixing 100 mm bore cast iron spun pipes soil, waste and vent pipes, in any length, with or without ears, with cement joints, laid in trenches or floors/walls, complete all as specified and directed.
Supply and fixing 75 mm bore cast iron spun pipes soil, waste and vent pipes, in any length, with or without ears, with cement joints, laid in trenches or floors/walls, complete all as specified and directed.
Supply and fixing 50 mm bore cast iron spun pipes soil, waste and vent pipes, in any length, with or without ears, with cement joints, fixed to walls, complete all as specified and directed.
Supply and fixing 50 mm dia cast iron cowl, complete all as specified and directed.
Supply and fixing grating doom PTMT 125 mm dia with waste holes (minimum weight 40 grams) , fixed as in repairs, complete all as specified and directed.
Supply and fixing grating doom PTMT 100mm dia with waste holes (minimum weight 25 grams) , fixed as in repairs, complete all as specified and directed.
Supply and fixing in repair Gun-metal globe or gate valves, with iron wheel head, screwed down, high pressure,heavy duty, ISI marked , screwed both ends for iron pipe or for unions of 15 mm bore dia complete all as specified and directed.
Supply and fixing in repairs cast iron 100 mm bore socket double collar fixed with lead joints, complete all as specified and directed.
Supply and fixing in repairs cast iron 75 mm bore socket double collar fixed with lead joints, complete all as specified and directed.
Supply and fixing in repair 75 mm cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed.
Supply and fixing in repairs cast iron 100 mm bore bend with duck's foot or heal rest, complete all as specified and directed.
Supply and fixing in repairs cast iron 75 mm bore bend with duck's foot or heal rest, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
Supply and fixing 110 mm PVC (SWR) pipes double socketed in any length with rubber ring joints, fixed to wall with suitable size of mild steel clamps and screws, including making good mouth of rain water pipe in cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius with rubber rings, fixed to walls with suitable clamps as in rain water pipes of 110mm bore complete all as specified and as directed.
Material and labour for applying two coats of synthetic enamel paint over and including a coat of pink primer, on new wooden surfaces over 10cm width or girth, including preparation of wooden surface, complete all as specified and directed.
Material and labourfor applying two coats of synthetic enamel paint on new already primed steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour for preparation of old wooden surfaces of any description, not otherwise described, over 10cm width or girth, applying one coat of synthetic enamel paint, complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) above ground floor and removal of debris outside MoD land, complete all as specified and directed.
Material and labour for roughening surfaces of old concrete slab by picking/wire brush, sweeping clean and washing down with water to remove dust etc. and brushing neat cement slurry @ 3.00 Kg/Sqm on roof surface, and removal of rubbish outside defence land complete all as specified and directed
Material and labour for plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in padding on roof, in required thickness to maintain desired slope, finished even and fair to receive tiles/ APP membrane, complete all as specified and directed.
Material & labour for Cleaning and preparation of roof/junction/crumple joints surfaces of RCC/Bricks tiles/Cement concrete and made free from dirt, foreign particles, laitance, followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surfaces caused by thermal expansion/ contraciton at junction/crumple joint. Cutting the "V" grooves with suitable cutter machine and filling with Repair Mortar/General Purpose Grout in the proportions as recommended by manufacturer, as per the requirement, making of gollas at all perimeter/corners/ crumple joints with Polymer Modified Mortar ( Cement : Sand 1:4 with 5% Acylic polymer by weight of cement), complete all as specified and directed. Make- SIKA/FOSROC/Asian Paints/Berger.
INTERNAL ELECRIFICATION WORK
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including GI earth wire on batten or in PVC conduit or in MS Conduit including fixtures and fittings such as switches, ceiling roses, pendants, fan regulators, sockets etc, removing materials to store for keeping in safe custody for reuse or for credit (credit for above items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Taking down defective main switches distribution board iron clad or sheet metal of any size and capacity including wooden board & MCBs,meters etc, complete all as specified and directed.
Material and labour for point wiring with single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100 volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including boxes with and including cover plate for housing modular switches, sockets, fan regulators etc, including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100 volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 3.03 here-in-before but for 3/5 pin socket outlet 5 Amps multipurpose on independent board.
All as per item No 3.03 here-in-before but for 2/3 pin socket outlet 5 Amps on same board with other switches.
All as per item No 3.03 here-in-before but light point controlled by 2-two way switch
All as per item No 3.03 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose socket outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board.
Supply and fixing switch modular type, single pole, one module, 6 Amps, 230volts, complete all as specified and directed.
Supply and fixing switch modular type, single pole, one module, 16 Amps, 230volts, complete all as specified and directed.
Supply and fixing switch bell push modular type, single pole, one module, 6 Amps, 230volts, complete all as specified and directed.
Supply and fixing switch modular type, two way, one module, 6 Amps, 230volts, complete all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pins combined, 6 Amps, 2 module, 230 volts, complete all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, 2 module, 230 volts, complete all as specified and directed.
Supply and fixing ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fixing modular type fan regulator, step type (4/5 steps),120 W, two module, suitable for 1200/1400 mm sweep ceiling fans including necessary connections, complete all as specified and directed.
Supply and fixing bell multi music type single pole AC 230 volt, 50 HZ, complete all as specified and directed.
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Supply and fixing in repair LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
Supply and fixing in replacement Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and fixing in replacement Lamp holder, PVC/Polycarbonate type suitable for pendant fittings, including LED bulb 10 watt, complete all as specified and directed.
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, SPN 240 Volts, 08 ways with 200 amps rated bus bar, double door, with IP 43 protection, complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure DB for Incoming MCCB, TPN 415 volt 4 way with 200 Amp bus bar with IP43 protection and outgoing MCBs factory made double door, with 200 Amp bus bar, including provision of MCCB four pole 100 Amps 16 KA with adustable thermal and magnetic release as incoming, complete in all aspects all as specified and directed . Note:- Outgoing MCBs shall be measured and paid separately under respective items. DB shall be flush mounted in the wall and unit rate shall be deemed to include the cost for the same alongwith making good the disturbed surfaces to match with the existing surfaces.
Supply and fixing in replacement sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB double pole, 240 Volts, 20 Amps, 10 KA, complete all as specified and directed
Supply and fixing MCB SP 06 to 32 Amps, 240volts, 'B' curve/ series, 10 KA, complete all as specified and directed.
Supply and fixing MCB SPN 40 to 63 Amps , 240 volts, 10 KA, 'C' curve/ series, complete all as specified and directed.
Supply and fixing MCB SPN 40 to 100 Amps , 415 volts, 10 KA, 'C' curve/ series, complete all as specified and directed.
Supply, fixing in replacement and testing ceiling fan 1200mm sweep, metallic body, metallic blades, copper wound, Min air delivery 210 CFM with service value 6.00, with minimum BEE 5 star rating, 230 volts, single phase, high speed, heavy duty, with burshless direct current motor (BLDC), including provision of PVC insulated flexible copper wire 1.5 Sqmm three core from ceiling rose to fan for giving connection, complete all as specified and directed. Note:- Old retrieved celing fan shall be deposited in MES store.
Supply and fixing in replacement and testing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, complete all as specified and as directed. Notes: 1. Cutting hole and making suitable opening in wall for fixing exhaust fan including making good to match the existing surfaces shall be deemed included in the quoted rate of item. 2. Old retrieved exhaust fan shall be deposited in MES store.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with twin twisted flexible copper conductor cable of suitable size, complete all as specified and as directed.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe medium grade 15mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI wire 4 mm dia and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Supply and fixing PVC non metallic rigid concealed conduit 40 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, including cutting chases/holes etc as required, complete all as specified and directed.
Supply and fixing electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH , complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORK
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Taking out / down old existing LT 1100volt grade cables, 35Sqmm, 70 Sqmm size, laid in trenches, including bricks/Precast PCC cable cover for protection, complete all as specified and directed.
Material and labour for sand cushioning with a layer of dry river sand, 80 mm thick before laying of cable and 150 mm thick (punned down to 100 mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
EXTERNAL WATER SUPPLY WORK
Supply and fixing galvanized steel water tubes 20 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches, in floor/ under road, including taking up or down existing steel water tubing and connections and removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. NOTE :- Excavation & earth work shall be measured and paid for seperately.
Supply and fixing galvanized steel water tubes 25 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches, in floor/ under road, including taking up or down existing steel water tubing and connections and removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. NOTE :- Excavation & earth work shall be measured and paid for seperately.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 25 mm bore, including taking down old & removal, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 20 mm bore, including taking down old & removal, complete all as specified and directed.
COMMON ITEMS FOR EXTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY WORK
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables, pipes, foundation of poles etc. and getting out, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick each, excavated soil in trenches after pipes have been laid and tested complete all as specified and directed.
Removal of surplus soil surplus soil to a distance n.exe 50 Mtr and depositing where directed at a level n. exe 1.5 mtr above the starting point complete all as specified and directed.
Note: The Total amount shall subject to adjustment of credit of Rs. 1,12,136.00 for old Materials as per Schedule of Credit.
Baba Engineers and Contractors
M/S MANI GARG CONTRACTOR
M/S MATLOOB AHMED
KUMAR AND COMPANY
KRISHAN KUMAR CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .