Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC C O NIDHI MEDICAL STORE LAKKAR BAZAR SHIMLA 01 | SHIMLA | HIMACHAL PRADESH | 171001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.9 L+₹3,481.23 (0.35%)Rejected-Finance A R AND M O ON VARIOUS ROAD IN SECTION NALAGARH 1 UNDER NALAGARH SUB DIVISION SH HIRING OF JCB | L2 | Rejected-Finance Non-Responsive due to L2 Bidder | |
| 3 | L3₹10.0 L+₹11,123.33 (1.13%)Rejected-Finance | L3 | Rejected-Finance Non-Responsive due to L3 Bidder | |
| 4 | L4₹10.1 L+₹18,141.54 (1.84%)Rejected-Finance | L4 | Rejected-Finance Non-Responsive due to L4 Bidder | |
| 5 | L5₹10.2 L+₹32,990.27 (3.34%)Rejected-Finance | L5 | Rejected-Finance Non-Responsive due to L5 Bidder |
Tender Value
₹10.2 L
EMD Value
₹20,450
Closing Date
9 Jul 2021, 11:00 amClosed
Executive Engineer HP PWD Division Nalagarh
Executive Engineer HP PWD Division Nalagarh
C/o Link road Tikkari Bohri Amb Da Har (SH- C/o 3 m span culvert at RD 3/900).
2021_PWD_49284_1
TA-2901-05 date- 16.06.2021
Open Tender
Civil Works
Item Rate
180 days
Nalagarh
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹20,450
17 Dec 2021
1 Jul 2021
9 Jul 2021
1 Jul 2021
9 Jul 2021
1 Jul 2021
Amount
Earthwork in excavation for structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Providing and laying concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification clauses 802,803,1202,and 1203 R.C.C. nominal mix 1:4:8(40 mm aggregates)., within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Plain/ reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 1202, and 1203 P.C.C grade M 10 Nominal mix (1:3:6), within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25 1:1.5:3
Providing and laying cement concrete wearing course M 30 Grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.0, within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202, within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Construction of R.C.C railing of M 25 grade in cast-in- suit with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed in 1 in 500, centre-to-centre spacing between vertical posts not to exceed 200 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3, within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Drainage spouts complete as per drawing and technical specifications Clause 1209, within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Providing weapholes in brick masoinry / stone masonary / plain /reinforced concrete abutment, wing wall return wall with 100 mm dia AC pipe extending through the full width of the structures with slop of 1(v):20 (h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7., within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Providing and laying filter media with granular crushed aggregate as per specification to thickness of not less then 600 mm with smaller size towards the soil and bigger size towards the walls and providing over the entire surface behind abutment, wing wall, retaining walls to the full height, completed to firm condition complete as per drawing and technical specification clause 1204.3.8., within all leads and lift as per the entire satisfaction and direction of Engineer-in charge
Manoj kumar
Naveen singh Govt Contractor
mustak
JASWINDER KUMAR
KARAM CHAND
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .