Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹20.9 L+₹97,943.88 (4.91%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹22.5 L+₹2.5 L (12.7%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹22.7 L+₹2.7 L (13.7%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹25.9 L+₹5.9 L (29.8%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
27 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) E/M Chakeri
GE(AF) E/M Chakeri, Kanpur-208008
REPAIR MAINT REPLACEMENT AND IMPROVEMENT WORK OF LT CABLES, CABLE JOINTS, LT OVERHEAD DISTRIBUTION SYSTEM, VARIOUS SERVICE CONNECTIONS AND DISTRIBUTION SYSTEMS AND OTHER CONNECTED WORKS IN TECH AREA AF STN, KANPUR
2021_MES_455181_1
8514/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE(AF) E/M Chakeri, Kanpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE(AF) E/M Chakeri
₹60,000
9 Aug 2021
28 Jun 2021
3 Aug 2021
28 Jun 2021
27 Jul 2021
5 Jul 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable in soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M & L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches for cable protection complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 45 cm in width & not exceeding 60 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed .
M&L for making horizontal boring 60 cm deep below road crossing for passing of LT cable in GI pipe complete all as specified and directed.
Taking out from trenches/duct/floor/wall/roof/under road/drain or hardstanding etc. old existing underground XLPE aluminium conductor LT cable for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed:- Size of cable - 2 to 4 core x 10 sqmm to 16 sqmm
All as per item No. 8 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item No. 8 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item No. 8 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item No. 8 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Re-laying only or fixing or passing through pipe, in Pole/duct/trench/under road/hardstanding/wall/roof etc. 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed old serviceable cable after checking of any type of faults (if any) by inspection / using equipment / meggering as required complete all as specified and directed including end termination by providing lugs/thimbles/glands by compression arrangement. Size of cable - 2 to 4 core x 10 sqmm to 16 sqmm
All as per item no. 13 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item no. 13 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item no. 13 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item no. 13 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Supply Laying, testing and commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells/Polycab/Finolex/Gloster
All as per item No 18 above but capacity 10 Sqmm 4 core
All as per item No 18 above but capacity 16 Sqmm 4 core
All as per item No 18 above but capacity 25 Sqmm 3.5 core
All as per item No 18 above but capacity 35 Sqmm 3.5 core
All as per item No 18 above but capacity 50 Sqmm 3.5 core
All as per item No 18 above but capacity 70 Sqmm 3.5 core
All as per item No 18 above but capacity 95 Sqmm 3.5 core
All as per item No 18 above but capacity 120 Sqmm 3.5 core
All as per item No 18 above but capacity 150 Sqmm 3.5 core
All as per item No 18 above but capacity 185 Sqmm 3.5 core
All as per item No 18 above but capacity 240 Sqmm 3.5 core
All as per item No 18 but capacity upto 400 Sqmm 3.5 core Note for Srl item No 18 to 30: The cable at various location shall be of varying lengths i.e. in pieces of different lengths as per requirement at site. The bidder shall quote rates keeping the note into consideration that this being a maintenance contract and bound to attend the emergent requirement immediately. Successful bidder shall abide by direction issued to him at the earliest for implementing the above items as per direction of Engineer-in-Charge.
Supply and laying in trenches/Floor or fixed to Pole/Wall in repair GI pipe light grade with fitting for protection of cable including dismantling existing pipe complete all as specified and directed. Size:- 40 mm bore. Make :- Jindal / Tata / Prakash Surya
All as per item No. 31 above but of size 50 mm bore.
All as per item No. 31 above but of size 80 mm bore.
All as per item No. 31 above but of size 100 mm bore.
M & L for detection of fault through fault locating high voltage mobile machine to locate the fault in LT cable by giving high voltage surge and to find out exact location of fault all as directed at site. (Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Arrangement of fault locating machine will be bidder responsibility & he should'nt expect facilitation from the dept. for the same.)
M & L for replacement of Straight through joint kit Heat shrinkable type suitable for XLPE under ground cable of size 10-16 sqmm 2/4 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 36 above but of size 25-50 sqmm 3.5 core.
All as per item No. 36 above but of size 70-150 sqmm 3.5 core.
All as per item No. 36 above but of size 185-240 sqmm 3.5 core.
All as per item No. 36 above but of size 300-400 sqmm 3.5 core.
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
Dismantling of ACSR conductor of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of Earth wire of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of insulators of any type, any sizes and at any location complete and removing the same from the site complete all as specified and directed.
Restriging of exisiting ACSR conductor / GI wire of any size / any no. conductor including opening of winding wire of ACSR conductor with insulator and winding with new aluminium winding wire and replacement of old jumper wires with new ACSR conductor complete all as specified and directed.
M & L for Aluminium conductor, steel rainforced (ACSR) of existing size & length as per site requirement complete all as specified and directed.
M & L for Galvanised steel wire 4 mm dia earth wire of existing size & length as per site requirement and complete all as specified and directed.
M & L for Pin type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel spindle, two galvanazed iron washer and one galvanazed nut, 100mm height, 65mm dia 1100 Volts grade complete all as specified and directed.
M & L for Shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps 31x3 mm , washers, insulator bolts 12 mm dia, 75 mm height, 90 mm dia & working pressure in 1100 volts complete all as specified and directed.
M & L for erection and replacement of stay assembly (wire size 7/4 mm) with stay rod 16 mm dia & insulator loop type with nuts, bolts and washers stay wires size 7/4 mm , Flat iron clamps, Nuts, bolts and washers including necessary excavation, removal of soil, refilling of soil, PCC 1:3:6 work, Plinth protection complete all as per Plate No 01 of MES SSR Part-I 2009.
M & L for replacement of PVC Line separator suitable for 02 / 03 nos over conductor with nuts, bolts and washers complete all as specified and directed.
M & L for replacement of PVC Line separator suitable for 04 / 05 nos over conductor with nuts, bolts and washers complete all as specified and directed.
Material & labour for painting on steel tubular sizes 9/11 mtr long pole structure with one coat of aluminium paint with 3 strips of blue paint after scratching of old paint, cleaning of all rusted portion & writing numbering on pole complete all as specified and directed.
M&L for removing old paint from LT panels by paint remover, cleaning of scrapping and preparing the surface and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer and writing work as per existing pattern complete all as specified and as directed.
S&F in repair of MCCB 630 Amps 36 KA, 4 Pole, Ics = 100% Icu adjustable over load setting with thermal magnetic release including lugs,nut,bolts.washers etc and dismantling of old MCCB testing and commissioning complete all as specified and directed. Make:- L&T / Schenider Electric / ABB / Legrand
All as per item no. 55 above but MCCB of capacity 400 Amps 36 KA, 4 Pole, Ics = 100% Icu
All as per item no. 55 above but MCCB of capacity 200- 250 Amps 36 KA, 4 Pole, Ics = 100% Icu
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of ACSR conductor complete all as specified and directed.
Receiving complaints from Complaint Section / JE / Engr-in-charge by any mode of communication & attending the same within 24 hours. This item is inclusive of all the preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues including removing carbon deposits (if any), cleaning of lugs/glands etc., meggering of cables, making temporary connections (as required), removing soil, rerouting cables and restoring back the power supply all as specified and directed. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 24 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment. Bidder must also appreciate the fact that the work is to be carried out in strategically important locations & hence casual delays are unacceptable. Bidder must also mobilize sufficient manpower in short span of time to meet the work expectations or else penal clauses shall be applicable.
M & L for replacement of End joint kit Heat shrinkable type suitable for XLPE under ground cable of size 70-150 sqmm 3.5 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 60 above but of size 185-240 sqmm 3.5 core.
All as per item No. 60 above but of size 300-400 sqmm 3.5 core.
Supply, laying, testing and commissioning of unarmoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor twin core of size 16 sq mm laid on wall/pole etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed.
Shifting of Panel / Transformer / HT Switchgear / HT OCB / RMU / DG Set to a distance not more than 8 Kms from power house/substation / any place to the required place, including disconnecting and necessary connection and testing after shifting complete all as specified and directed.
S & F in replacement aluminium lugs along with nuts, bolts of size 95 Sqmm complete all as specified and directed.
BHATIA ENTERPRISES
M/S DARSHAN ENGINEERING WORKS
VEE KAY ENTERPRISES
SAKSHAM SUPPLIERS BUILDERS
Bharat Sales Corporation
ashokcontractors
M/S Balaji Infratech
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .