| Sl No | Description | Qty | Unit | Speedfrost Services Pvt. Ltd. L1 | NEW NATIONAL AIRCONDITIONING CO. L3 | Gil Airconditioning And Refrigeration Services L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing fully comprehensive annual maintenance of TOSHIBA make VRF System installed at Mazgaon Court Building, Mazgaon, Mumbai.
The VRF system includes Outdoor units as ( 24 HP x 1 + 26HP x 1 + 42 HP x 2 + 44 HP x 2 + 46 HP x 3 + 50 HP x 3 + 52 HP x 4 = 718 HP). The VRF system ncludes Indoor Units of Cassette type as ( 1.28 TR x 51 + 1.59 TR x 32 + 2.0 TR x 79 + 2.56 TR x 81 + 3.18 TR x 52 + 3.98 Tr x 10 + 3.98 x 7.96 x 2 TR Ducted IDU 1 + 1.3 TR One way cassette 47 Nos + 1.5 TR Hi-wall 1 Nos) total Indoors=347 Nos. There are Conventional 12 nos of Spilt Ac AC units. The Hybrid, thermal solar panel connected with all VRF outdoor units to use solar energy to superheat the compressed gas by ODU. Total 67 HTS panels are used (1 job Per Month Hence for 12 Months = 1 Job x 12 Months = 12 jobs ) The scope of work includes: 1. Carrying out Routine Inspection,checking & servicing of the units Monthly to keep the air conditioning system in healthy working condition & cleaning filters once in a month. 2. Replacement and repairs of all spares and material, compressor, motor, all kind of conectors& electrical parts, all panel switchgeras , remote control panel, & their control cables, wire or cable leads of compressor & motor, condenser pumps,have to be done whenever necessary or as per instruction of Engineer in charge. All copper control cables in between indoor units/outdoor units and remote control, will have to be maintained or replaced by the contractor as & when required. 3. Attending breakdown call within 2 hrs. after prior intimation of Engineer in charge or any other competant authority of user departments. 4. Condenser coil will be inspected and cleaned with air blower. Every year anti corrosive treatment is to be done by the contractor. 5. Cleaning and replacement of Air Filters of the units once in every month or as and when required. 6. Cleaning and replacement of drain pipe of the units or as and when reqired . 7. Gas charging should be done as & when required . VRF circuit replacement, sensors replacement, blower replacement, air filters
replacement and cleaning, heater and its controller repairs and replacement shall be included in the AMC. Technician should be present on site for VIP meetings and conferences | 12 | Job | 5,37,334 ₹64.5 L | 5,65,000 ₹67.8 L | 5,50,000 ₹66 L |
| 2.00 | Providing maintenance of Hybrid thermal solar panel including cleaining of solar Glass, Top, Overhauling / servicing of Tracking Contralers & brushless stepper motor. Complete with all accessories. (67 panels x 12 months = 804 Jobs) | 804 | Each | 1,717 ₹13.8 L | 1,750 ₹14.1 L | 1,800 ₹14.5 L |
Tender Value
Refer Docs
Closing Date
6 Feb 2026, 5:30 pmClosed
Executive Engineer Central Mumbai Electrical Divis
Executive Engineer Central Mumbai Electrical Division Sadhana House 2nd floor, Pandurang Budhkar marg, Behind Mahindra Tower, Worli, Mumbai -18
Providing fully comprehensive annual maintenance of TOSHIBA make VRF System installed at Mazgaon Court Building, Mazgaon, Mumbai.
2026_PWDM_1273086_1
Quatation/21/25-26/Tos VRF/1st
Open Tender
Electrical Works
90 days
JJ Hospital subdivision
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
9 Feb 2026
30 Jan 2026
9 Feb 2026
30 Jan 2026
6 Feb 2026
30 Jan 2026
Providing fully comprehensive annual maintenance of TOSHIBA make VRF System installed at Mazgaon Court Building, Mazgaon, Mumbai. The VRF system includes Outdoor units as ( 24 HP x 1 + 26HP x 1 + 42 HP x 2 + 44 HP x 2 + 46 HP x 3 + 50 HP x 3 + 52 HP x 4 = 718 HP). The VRF system ncludes Indoor Units of Cassette type as ( 1.28 TR x 51 + 1.59 TR x 32 + 2.0 TR x 79 + 2.56 TR x 81 + 3.18 TR x 52 + 3.98 Tr x 10 + 3.98 x 7.96 x 2 TR Ducted IDU 1 + 1.3 TR One way cassette 47 Nos + 1.5 TR Hi-wall 1 Nos) total Indoors=347 Nos. There are Conventional 12 nos of Spilt Ac AC units. The Hybrid, thermal solar panel connected with all VRF outdoor units to use solar energy to superheat the compressed gas by ODU. Total 67 HTS panels are used (1 job Per Month Hence for 12 Months = 1 Job x 12 Months = 12 jobs ) The scope of work includes: 1. Carrying out Routine Inspection,checking & servicing of the units Monthly to keep the air conditioning system in healthy working condition & cleaning filters once in a month. 2. Replacement and repairs of all spares and material, compressor, motor, all kind of conectors& electrical parts, all panel switchgeras , remote control panel, & their control cables, wire or cable leads of compressor & motor, condenser pumps,have to be done whenever necessary or as per instruction of Engineer in charge. All copper control cables in between indoor units/outdoor units and remote control, will have to be maintained or replaced by the contractor as & when required. 3. Attending breakdown call within 2 hrs. after prior intimation of Engineer in charge or any other competant authority of user departments. 4. Condenser coil will be inspected and cleaned with air blower. Every year anti corrosive treatment is to be done by the contractor. 5. Cleaning and replacement of Air Filters of the units once in every month or as and when required. 6. Cleaning and replacement of drain pipe of the units or as and when reqired . 7. Gas charging should be done as & when required . VRF circuit replacement, sensors replacement, blower replacement, air filters replacement and cleaning, heater and its controller repairs and replacement shall be included in the AMC. Technician should be present on site for VIP meetings and conferences
Providing maintenance of Hybrid thermal solar panel including cleaining of solar Glass, Top, Overhauling / servicing of Tracking Contralers & brushless stepper motor. Complete with all accessories. (67 panels x 12 months = 804 Jobs)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_2191637.xls
BOQ • 1.04 MB
Download all tender documents and submit your bid