| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.2 L+₹2.9 L (11.4%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹37.5 L+₹12.2 L (48.0%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25.2 L
EMD Value
₹50,320
Closing Date
8 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
REPAIR AND MAINTENANCE OF HT SUPPLY DISTRIBUTION SYSTEM WITH CONNECTED ACCESSORIES AT JORHAT MIL STN UNDER GE JORHAT
2021_MES_419763_3
83044E8
Open Tender
Civil Works
Item Rate
180 days
GE JORHAT
AS PER TENDER
6 documents required · 6 mandatory
₹500
GE JORHAT
₹50,320
Yes
7 Jun 2021
22 Mar 2021
9 Apr 2021
22 Mar 2021
8 Apr 2021
27 Mar 2021
23 Mar 2021 - 26 Mar 2021
60 days
Amount
Dismantling insulators of any type and any size from HT 2/4 pole structures/pole after taking proper electric shut down complete all as specified and as directed.
S & F Pin type, polymer post insulator, vitreous, white or grey insulator including one 19 mm dia galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia with top groove suitable for 11000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
S & F suspension and tension type polymer post insulator (disk), vitreous 145mm high white, brown or green,two in series assembly for tension with tension GI clamps, Nuts, Bolts and washer etc suitable for working pressure 11000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
S & F Pin type, polymer post insulator, vitreous, white or grey insulator including one 19 mm dia galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 580 mm minimum creepage distance with top groove suitable for 33000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
S & F suspension and tension type polymer post insulator (disk), vitreous 145mm high white, brown or green,two in series assembly for tension with tension GI clamps, Nuts, Bolts and washer etc suitable for working pressure 33000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
Dismantling cross arms of mild steel channel or angle sections etc. complete and removing unserviceable materials from site(s) complete all as specified and directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified & as directed.
Dismantling of ACSR or AAC conductor from poles of any size & capacity and unserviceable materials removing from site(s) complete all as specified and as directed
M&L for Aluminium conductor steel reinforced (ACSR) for 33 KV of size as per existing for making connection at transformer, LAs, CT , PT, GOD,s & Drop out fuses etc complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white in 11000 volts, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
M & L for switches air break switch, gang operated, triple pole, 11000 Volts grade and current rating up to 400 Amps, mechanically operated, mounted on insulator of size 150 mm dia and 150 mm height and steel frame with operating mechanism worked from ground level having 3 Nos 11KV Post Insulators per phase with locking arrangements etc. and equipment shall be confirming to IS 9921 (Part I to V) including necessary electrical connections after taking down the old unserviceable GOD switches with all parts complete all as specified and as directed.
M&L for HT drop out expulsion fuse unit suitable for 100 Amps Capacity at 11 KV ,single pole (two post insulators per pole) with HT barrel fuse with holder including necessary connection to ACSR conductor of suitable size after taking down the old unserviceable drop out switches complete all as specified and as directed.
Supply ,laying, jointing, commissioning & testing HT UG cable of size 95 Sqmm 3 core, 11000 volts (earthed), aluminium conductor, XLPE insulated, earthed, screened, PVC bedded, armoured heavy duty electric cable conforming to IS-7098 (Part -II) 1985 with latest amendments drawn through pipe or laid in trenches, fixed on poles etc. including taking out the old unserviceable ones and stored as and where directed complete all as specified and as directed.
M&L for fixing and connection of lightening arresters set ( Set of 03 nos), non linear 12 KV, metal oxide type, distribution class 5 KA rupturing capacity for outdoor use with conforming to IS : 15086 PT- I of 2001, complete and suitable for 11KV supply system including taking down the old unserviceable ones complete all as specified and as directed.
Supply, jointing and testing HT cold shrinkable jointing kit straight through type for 11000 Volt grade 3 core XLPE insulated Earthed cable outdoor type complete with jointing material and accessories of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable ones complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supply & Laying for Rubber insulating mat in replacement of thikness size not less than 5 mm thick, confirming to relevant IS complete as approved by GE duly ISI marked all as specified and directed.
Supply only rubber insulating hand glove suitable for working up to HT 33 KV in replacement confirming to relevant IS complete as approved by GE duly ISI marked all as specified and directed.
Supply and fixing HT Lightening arrestor ( Set of three) Station Class III, discharge capacity 65 Kilo Amps suitable for working voltage 33 KV with connected accessories like nut bolts, washers etc and making connections properly to earthing systems including taking down the old unserviceable ones complete all as specified and directed.
Excavation in trenches, for foundation of poles, stays or for laying of cables, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out as in soft / loose soil complete all as specified & directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil completer all as specified and directed.
Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L of Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 300mm x 230mm x 40 mm over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete
M&L for sand cushioning to underground cable in trenches with clean dry river sand for protection of cable complete all as specified and directed.
M&L for boring /drilling by machines/manual horizontally under the road in any type of soil without cutting /disturbing the existing road and inserting GI pipe of any size for drawing the cable. complete all as specified & as directed.
M&L for cutting the road/ hard standing to a size not exceeding 30 cm in width not exceeding 75 cm in depth for laying/ removal of HT/ LT UG cable or cable protection pipe of any size including making good the disturbed surfaces by using PCC(1:4:8) type D2 (using 40 mm graded aggregates) for 100 mm thick on top including fair finishing complete
M & L for 80 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures /poles complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanized iron strip 32 x 6 mm earthing lead connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanized iron protected by 40 mm dia (light grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 54 x 54 x 5 cm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 3 of SSR part-I and testing on completion including taking out the old unserviceable earthing materials complete all as specified and as directed.
Supply and fix in replacement of galvanised iron strip of size 25 x3.15 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground all as specified.
Disconnecting and takingout,repairing existing APFC HT 11 KV VCBs for seviceable & reuse (One No-150 KVAR & Two No-75 KVAR ) (Make : Areva) from housing and cleaning,rubbing and overhauling the mechanical parts and making serviceable of local/remote electrical operation of the panel including Greasing,oiling,replacement of UNSV Trip coil,breaker charging motor,gear pinion,roller switch and reassembling the same after replacement as required including testing (IR Test,Continuity Test,Tripping Test of earth fault and over current of panel) complete all as specified and directed (Note :All Spares parts of VCBs panel will be Measured and paid sepratly under respective items of this schedule here in after as supply only)
M & L of 4 pole/2 pole structure of 11 KV Gang operated devices Servicing, greezing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for gang operations handle (medium grade,appx lenght 06 mtr) including clamps etc complete all as specified and directed.
M & L of 33 KV isolator/GODs Servicing, greasing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for Isolator operations handle including clamps etc complete all as specified and directed. Note : Spare parts such as moving arm,operating pipe GI 32 mm,insulator base, MS channel 75x40x5 mm,fixed contact -copper flat (voltage 33 KV) shall be including in item quoted rates
Material and labour painting of existing RCC cable route indicators ( both civil and mil area)with synthetic enamilled two coats of brown in colour and write with white colour letters for indication of joint/ area etc ,incl minor repairs with rendering,grouting at site complete all as specified and directed.
Dismantling of HT/LT connection at site from earthing lead carefully defective Transformer of capacity of 25 KVA to 315 KVA, 11 KV/440Volt, opening the top cover of the transformer at site, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) including necessary replacement of spares/ components complete all as specified and directed. (NOTE: Spares/ components required to be replaced shall be measured and paid as supply only under relevant items of this schedule.)
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 25 to 315 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as specified and directed
Supply only LT bush insulator as per existing size , shape and make for 25 to 315 KVA capacity transformer.
Supply only LT brass/copper stud as per existing size , shape and make for 25 to 315 KVA capacity transformer.
Supply only gasket ( Set of four) for LT bushing as per existing size and shape for 25 to 315 KVA capacity transformer.
Supply only top cover cork gasket set as per existing size and shape for 25 to 350 KVA capacity transformer.
Supply only HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 25 to 315 KVA capacity transformer.
Supply only breather assembly including silica gel of required quantity for 11/0.433 KV transformer for 25 to 315 KVA capacity .
Supply only breather assembly including silica gel of required quantity for 33/11 KV transformer of any capacity .
Supply, filling and topping up new transformer oil conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as directed. ( Dielectric strength of oil shall not be less than 40KV ) Make: GULF/POWER OIL or equivalent as approved by GE.
Dehydration and filtration of existing transformer oil of transformer at different location in site with filtration machine and heating system to get Di-electric strength of oil 40KV/cm minimum without disturbing the power supply system complete all as specified and as directed.
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 11/0.433 KV transformer complete all as specified and directed.
M/L for cleaning of conservator oil tank of capacity 25 to 300 KVA transformers including refixing of rubber cork gasket as per existing size complete all as specified and directed.
Supply & connect in replacement of battery 180 AH, 25 plate with initial Charger Specific gravity 12.60 of 12 volts complete all as directed by Engineer-in-Charge. (Make:- EXIDE/Amron or equivalent
M & L for preparing and painting and painting on steel tubular swaged pole 410 SP-55 (11.00 metre long) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply and fix in replacement of HT Cable route indicators made up of RCC Slab of min 20cm x 20 cm x 1.2 m (LXBXH) duly white painted and written "MES HT CABLE"/HT STRAIGHT JOINT" as required in Black colour complete all as specified and directed. (Note : The cost of excavation, and PCC shall be included in quoted rate)
Supply and fixing of Steel tubular swaged poles 11 m long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 complete all as specified and directed
M&L for PCC (1:3:6) type C-1 using 20mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Panel board, stay, repairs to road cutting, drain, path, making hard surface etc including provision of necessary form work, finishing even and smooth without using extra cement, complete all as specified and directed
M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Panel board, stay, repairs to road cutting, drain, path, making hard surface etc including provision of necessary form work, finishing even and smooth without using extra cement, complete all as specified and directed
M&L in replacement of stay assembly complete with accessories as shown in electrical plate No. 1 with stay rod of dia 16mm bore including excavation and PCC work including taking out old unsv complete all as specified and directed. Note : Loop type insulator shall be measured and paid for seperately.
M&L in replacement for galvanised stay strand, 7/3.15mm dia including bending, binding and fixing properly all as specified and directed.
M&L in replacement for loop type insulator, vitreous porcelain, white, brown or green small size with overall dimensions 65x90mm, clearance of hole 16mm all as specified.
THE SUPPLY AGENCY
HEMONTA DAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .