Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹6.3 LAccepted-AOC | 1st | Accepted-AOC 1st BIDDER | |
| 2 | 2ed₹4.9 L+₹27,147.80 (5.82%)Rejected-Finance MYOREPUR ANPARA ANPARA ANPARA SONBHADRA UTTAR PRADESH 231225 | SONBHADRA | UTTAR PRADESH | 231225 | 2ed | Rejected-Finance 2ed Bidder | |
| 3 | 3ed₹5.2 L+₹54,286.46 (11.6%)Rejected-Finance | 3ed | Rejected-Finance 3ed Bidder |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
13 Dec 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE OMC IV ATPS ANPARA
OFFICE OF SE OMC IV ATPS ANPARA
Routine/Breakdown maintenance of HT/LT cables and control cables of 3x210MW, ATPS, Anpara.
2021_RVUNL_639256_1
12/OMC-IV/EMD-II/ATPS/2021-22
Open Tender
Electrical Works
Fixed-rate
365 days
ATPS ANPARA
PLEASE REFER TENDER DOCUMENT
3 documents required · 3 mandatory
₹590
DY Chief Account Officer, CFA and BO, ATPS, ANPARA
₹13,000
8 Apr 2022
2 Nov 2021
15 Dec 2021
2 Nov 2021
13 Dec 2021
2 Nov 2021
120 days
Amount
Routine maintenance of various cabling works which includes salvaging, laying, lugging, ferruling, glanding and end termination, straight through jointing , repairing, tracing and rectifying of fault in cables of LT power/ control cable of various sizes upto 70 sq.mm. Of any number of core. Aluminium cables- All sizes up to max. size of 70 Sq.mm Copper cables- All sizes up to max. size of 70 Sq.mm Control cables- For ATRS, DAS, Excitation System etc.
Salvaging Per Meter
HT (1X100 PLCC 35 KV,1X630 XLPE 6.6 KV, 3X150 XLPE 6.6 KV)
Laying per meter
HT (1X100 PLCC 35 KV,1X630 XLPE 6.6 KV, 3X150 XLPE 6.6 KV)
Termination per No.
HT (1X100 PLCC 35 KV,1X630 XLPE 6.6 KV, 3X150 XLPE 6.6 KV)
Straight jointing per No.
HT (1X100 PLCC 35 KV,1X630 XLPE 6.6 KV, 3X150 XLPE 6.6 KV)
Salvaging Per Meter
LT-1(1.1 KV PVC, 1X1000, 1.5X400, 3X400)
Laying per meter
LT-1(1.1 KV PVC, 1X1000, 1.5X400, 3X400)
Termination per No.
LT-1(1.1 KV PVC, 1X1000, 1.5X400, 3X400)
Straight jointing per No.
LT-1(1.1 KV PVC, 1X1000, 1.5X400, 3X400)
Salvaging Per Meter
LT-2(1X500, 3.5x300, 3x300, 3.5x240, 3x240)
Laying per meter
LT-2(1X500, 3.5x300, 3x300, 3.5x240, 3x240)
Termination per No.
LT-2(1X500, 3.5x300, 3x300, 3.5x240, 3x240)
Straight jointing per No.
LT-2(1X500, 3.5x300, 3x300, 3.5x240, 3x240)
Salvaging Per Meter
LT-3 (2x240, 3.5x185, 3x185)
Laying per meter
LT-3 (2x240, 3.5x185, 3x185)
Termination per No.
LT-3 (2x240, 3.5x185, 3x185)
Straight jointing per No.
LT-3 (2x240, 3.5x185, 3x185)
Salvaging Per Meter
LT-4 (3.5x150, 3x150, 3.5x120)
Laying per meter
LT-4 (3.5x150, 3x150, 3.5x120)
Termination per No.
LT-4 (3.5x150, 3x150, 3.5x120)
Straight jointing per No.
LT-4 (3.5x150, 3x150, 3.5x120)
Salvaging Per Meter
LT-5 (2x150, 3x120, 2x120)
Laying per meter
LT-5 (2x150, 3x120, 2x120)
Termination per No.
LT-5 (2x150, 3x120, 2x120)
Straight jointing per No.
LT-5 (2x150, 3x120, 2x120)
Salvaging Per Meter
LT-6 (3.5x195, 3x95, 2x95)
Laying per meter
LT-6 (3.5x195, 3x95, 2x95)
Termination per No.
LT-6 (3.5x195, 3x95, 2x95)
Straight jointing per No.
LT-6 (3.5x195, 3x95, 2x95)
Salvaging Per Meter
LT-7 Copper (1x120, 1x95)
Laying per meter
LT-7 Copper (1x120, 1x95)
Termination per No.
LT-7 Copper (1x120, 1x95)
Straight jointing per No.
LT-7 Copper (1x120, 1x95)
Salvaging Per Meter
LT-8 Control cable up to size of 70 Sq.mm and more than 10 mtrs. (cable length)
Laying per meter
LT-8 Control cable up to size of 70 Sq.mm and more than 10 mtrs. (cable length)
Miscellaneous, works related with maintenance of cable racks, trays risers,reducersm Elbows etc.
Replacement of deteriorated M.S. Trays.
Replacement of deteriorated cable rakes.
Erection of junction boxes.
provision of riser, reducer, Elbow etc.
Erection after modification of various type of TPN switch/starter maximum up to 400 Amp.
Removal, re-fixing of tray covers in Boiler area.
Removal and re-fixing of chequer plates or grid on Boiler floor for attending cable fault on beneath the racks
Fabrication fo cable racks & other steel structures
Providing new tray cover at different location and clamping there of as per size.
Work of part - A required to be done during holidays and odd hours
Repair of Hydraulic crimping tool
M/S RANJANI CONSTRUCTION CO.
M/S THERMAL INDIA
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .