| 1 | L1₹14.7 LAccepted-AOC AT DHORI STAFF QTR P O DHORI DIST BOKARO | BOKARO | JHARKHAND | 825102 | ₹14.7 L Quoted ₹12.5 L | L1 | Accepted-AOC L1 and all documents as per NIT |
| 2 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | - | Rejected-Technical submitted annexure is not proper |
| 3 | Rejected-Technical 1BR COLONY POST BACHRA P S PIPARWAR DISTT CHATRA JHARKHAND | CHATRA | JHARKHAND | 825103 | - | - | Rejected-Technical submitted work experiance is not of similar nature |
| Sl No | Description | Qty | Unit | BIGAN SAW L1 |
|---|---|---|---|---|
| 1.01 | Supply and providing 9 meter RCC electrical pole | 43 | Nos | 9,200 ₹3,95,600 Lowest |
| 1.02 | Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 8.0 metre and upto 11.0 metre | 43 | Nos | 5,350 ₹2,30,050 Lowest |
| 1.03 | Erection of All Aluminium conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required
14 x 4 x30 x.214 + 26x2x30x.214= | 694 | kg | 195 ₹1,35,330 Lowest |
| 1.04 | Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 26 | set | 4,500 ₹1,17,000 Lowest |
| 1.05 | Supplying and erection of of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required . | 100 | set | 850 ₹85,000 Lowest |
| 1.06 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required | 30 | set | 1,225 ₹36,750 Lowest |
| 1.07 | Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required | 114 | set | 170 ₹19,380 Lowest |
| 1.08 | Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required | 40 | set | 120 ₹4,800 Lowest |
| 1.09 | Supply and erecftion of 6 swg GI wire (30x2x25x.195=) | 291 | Kg | 90 ₹26,190 Lowest |
| 1.10 | Erection of cradle guard | 375 | nos | 105 ₹39,375 Lowest |
Tender Value
Refer Docs
EMD Value
₹18,500
Closing Date
4 Nov 2025, 1:00 pmClosed
PE(EnM),KGOCP
Office of the Project Officer ,KGOCP
Estimate for the work of Power supply arrangement to batching plant and pumping system for ongoing work of 7 MTPA Karo CHP
2025_CCL_346145_2
PE(EnM)/KGOCP/Tender/25-26/07
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kargali OCP, BnK Area
as per NIT
6 documents required · 6 mandatory
₹18,500
23 Jun 2026
24 Oct 2025
5 Nov 2025
24 Oct 2025
4 Nov 2025
25 Oct 2025
24 Oct 2025 - 2 Nov 2025
Amount
Supply and providing 9 meter RCC electrical pole
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 8.0 metre and upto 11.0 metre
Erection of All Aluminium conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required 14 x 4 x30 x.214 + 26x2x30x.214=
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required
Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required
Supply and erecftion of 6 swg GI wire (30x2x25x.195=)
Erection of cradle guard
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
light fitting , installation testing of departmentally supplied light fitting
Handling of RCC cement poles /dismantale pole site and transporting of pole at working site.
supply of street light auto timer with protection from voltage fluctutation , MCB based overload trip, IP 54, transformer /battery free operation , operating voltage 150 V to 280V , single phase , all mechanisum in single SS enclosure-5000 watt
Providing of Clamp insulated double core wire 4 sqmm of 20 meter and other accessories with fixing arrangement on pole
onsite installation and checking fixing and calibrating at regular interval upto warrenty period
Installation of 100-160 KVA transformer with all accessories including cable connection and laying
clearing jungle including uprooting of rank vegitation , grass , bush ,wood , treesand samplings of grith upto 30 cm measured at a height of 1 m above ground level and removal of rubbish rubbish upto a distance of 50 m outside the periphery of the area cleared.
Dismantling of pole /strut embedded in cement concrete foundation etc. as required
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
2.58 MB
BOQ
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .