Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹33.0 L+₹2.4 L (7.97%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹33.5 L+₹2.9 L (9.33%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹34.9 L+₹4.3 L (14.0%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹36.0 L+₹5.4 L (17.5%)Rejected-AOC 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-AOC L5 Bidder |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
10 Aug 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
PROVISION OF FOUR HIGH MAST LIGHTS IN CFEES COMPLEX UNDER GE I RND DELHI
2020_MES_358959_1
GE/RND-33/DLI/2020-2021
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class- D, Cat b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹94,600
Yes
11 Sept 2020
7 Jul 2020
12 Aug 2020
7 Jul 2020
10 Aug 2020
29 Jul 2020
Amount
Supply, installation, testing & commissioning of Galvanised steel high mast lighting system of 16 Meter high mast shafts in two sections Top dia 200mm and bottom dia 460mm suitable for 47m/s wind speed, with latching type head frame, winch mounting bracket, lumanaries, carriages suitable to install 08 Nos 180 W LED lumanaries in symmetrical arrangement including with 6 core 2.5 Sqmm multistranded copper conductor wire for connection of LED light filltings and Aviation light complete including RCC foundation work as per manufacturer design and provision of raising lowering system comprising double drum SWL of winch and 6 pole single speed 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor 1 HP , manual handle, junction box including necessary GI Strip/ Copper wire separate earthing connection for lightening finial and fixing of foundations bolts 08 Nos of size 850mm long 30mm dia manufactured from special steel along with nuts, washers, anchor plate and common template and fixing Aviation light comprising of aluminium housing with polycarbonate enclosure including necessary excavation & earth work in any type of soil, foundation etc as per OEM inspection complete all as specified and directed at site. Make: BAJAJ/CROMPTON GREAVES/WIPRO NOTE :(i) Technical specifications for 16 Mtr High Mast Pole & Drg for foundation of pole is enclosed. (ii) Wind Tunnel Test certificate carried out successfully by reputed institutes should have with the manufacturer. (iii) LED shall be measured and paid seperately
Supply, laying, connecting and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cross sectional area or size 16 Sqmm 4 Core complete all as specified and directed.
Supply, laying, connecting and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cross sectional area or size 25 Sqmm 4 Core complete all as specified and directed.
S&F LED Flood light 180 watt with pressure die cast aluminium housing lumanaries complete with all accessories. Make: Model No. JETAPROPLUSFL180WLED757LTG of Havells or equivalent CG/Philips.
S&F LED street light 120W watt with pressure die cast aluminium housing luminaries complete with all accessories complete all as specified and directed. Make:Model No. ENDURACITYLINERNEOSL120WLED757SASYBOTG of Havells or equivalent CG/Philips.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width for laying of LT UG cables etc complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mmX 150mmX 40mm in trenches for cable protection keeping width of the cover parallel to the length of the cable all as specified and directed.
Excavation in tranches in hard/dense soil not exceeding 1.5m depth not exceeding 1.5m in width for laying of UG cable complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique/mannually/mechanically suitable for 100 mm dia GI pipe and necessary machine complete all as specified and directed.
Supply and laying GI pipe light grade of 100mm dia laid in trenches for protection of UG cable complete all as specified and directed.
All as per ser item No. 13.00 above but 80mm dia.
All as per ser item No. 13.00 above but 50mm dia.
Supply, installation testing and commissioning of outdoor type LT Panel inner sheet made out of 3.15 mm thick CRCA mild steel sheet factory made polycarbonate approx size 1000x600x300mm (shock proof, rust free, corrosion free, dust proof, dust proof (heat ventilation) acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free, recyclabel material) UV resistant, having high grade gasket made of polyurethane, should withstand glow wire test at 96 degree Centigrade shall be flame retardant. The LT panel shall be as per CPRI certification with switchgear assemblies as per IEC 60439-1. The LT Panel mounted on angle iron frame of size 40mmx40mmx6mm thick upto 60 cm height including necessary excavation & PCC 1:2:4 type B-1 foundation for grouting of LT panel complete with multifunctional meter, Phase indicator LED Lamp for RYB phase having front opening Door with locking arrangements and suitable to accommodate the following :-
Dismantling and taking down existing steel tubular /PCC pole 9 mtr long including necessary earth work, breaking of PCC and shifting to new location complete all as specified and directed.
M&L for fixing of pole retrieved serviceable from ser item No. 17.00 above including fixing of Junction box SMC KIOSK box water proof IP-54 of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed. Note: Eartwork, PCC will be measured and paid separately.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for pole foundation etc including filling in road cuts etc all as specified and as directed.
M&L for PCC (1:2:4) type C2 (using 40mm graded crushed stone aggregate) as in base foundation/Copping of pole including 10 mm thick plaster in CM 1:4, necessary form work complete all as specified and directed.
Supply, installing, testing and commissioning factory made panel approx size 1200x500x1700mm and tested LT indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 800 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm x 5 mm thick duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for heat dissipation. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, complete all as specified and as directed.
BUS BAR CHAMBER :- (a) 800 Amps 3 phase & Neutral 800 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 3 Phase - 01 Set. (ii) C.T's of capacity 600/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. (Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY:- (i) MCCB 400 Amps, breaking capacity 35 KA 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100%ICU = 01 No., OUTGOING SUPPLY :- (i) MCCB 160 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU= 02 Nos., (ii) MCCB 100 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 05 Nos. (iii) Onload Change over switch 320A= 01 No
Supply, installing, testing and commissioning factory made panel approx size 1200x500x1375mm and tested LT outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 800 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of MS angle iron 75X40 mm X 5 mm thick duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for heat dissipation. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 800 Amps 3 phase & Neutral 800 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, , 3 Phase - 01 Set. (ii) C.T's of capacity 600/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY :- (i) MCCB 400 Amps, breaking capacity 35 KA 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100%ICU = 01 No., OUTGOING SUPPLY :- (i) MCCB 160 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU= 02 Nos., (ii) MCCB 125 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 02 Nos. (iii) MCCB 100 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 02 Nos. (iii) Onload Change over switch 320A= 01 No Note for ser item no. 16, 21 & 22 (i) Before fabrication of panel the contractor shall submit detailed general arrangement drawing and single line diagram of all panel for approval. A drawing shall also show foundation details, list of components in the manufacturers reference and bill of materials. (ii) Panels will be manufactured by CPRI approved and manufacturer CPRI test certificate to be produced.
M&L for earthing complete with Galvanised iron plate electrode 600 mmX600mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below normal GL) with top edge of earth plate not less than 1.5 mtr below GL connected to GI strip 25 mm X 4 mm by means of GI nuts, bolts, check nut & washers GI strip protected with & including 40mm dia medium grade ISI marked GI pipe & connected to main switch board all as shown in electrical plate No 3 of MES schedule part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm watering arrangements with 20 mm dia GI pipe medium grade ISI marked, GI funnel with GI mesh, filling with mixture of common salt & charcoal with alternate layers including, necessary excavation and earth work in any type of soil, including test point, testing & commissioning complete all as specified & directed
M&L for Earthing with Galvanised iron earth plate electrode 600 mmx 600 mmX 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top edge of earth plate not less than 1.5 metre below GL connected to GI wire 4 mm connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm watering arrangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal with alternate layers including, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and as directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm dia GI wire complete all as specified and directed
Leo Air and Power Solution pvt Ltd.
Commercial Traders
jay maa engineers
Gupta Automobiles
Surjit and Sons
M/s KUNDU CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .