| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹6.1 L+₹17,834.45 (3.01%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹6.5 L+₹54,762.25 (9.23%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹6.6 L+₹62,569.55 (10.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹8.6 L+₹2.7 L (45.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.7 L
EMD Value
₹19,300
Closing Date
15 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/ REPLACEMENT AND MAINT OF LT OH CONDUCTOR/ CABLE, LT PANEL AND CONNECTED WORKS FOR AOR OF HQ 6 AND 13 SECT, THANAMANDI, MANJAKOTE, POTHA AND DARABA UNDER AGE(I) CIF (R)
2024_MES_688789_1
AGE(I)/R-56/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
AGE (I) CIF(R)
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,300
Yes
10 Feb 2025
16 Dec 2024
22 Jan 2025
16 Dec 2024
15 Jan 2025
31 Dec 2024
Amount
M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 150 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
All as per item No. 1 here-in-before but cross-sectional area 50 sqmm, 3.5 core complete.
All as per item No. 1 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete.
All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete.
All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 2 core complete.
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, cable, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed.
All as per Item No: 6.00 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-31, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid separately.
Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety, testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed.
S&F in replacement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed.
S&F for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by the Engineer-in-charge.
All as per item No. 17 here-in-before but rating 160Amp & breaking capacity 36KA.
All as per item No. 17 here-in-before but rating 200Amp & breaking capacity 36KA.
All as per item No. 17 here-in-before but rating 250Amp & breaking capacity 36KA.
S&F in replacement of alluminium cable thimbles of size 185 Sqmm UG Cable including complete connection and crimping, complete all as specified.
All as per Item No.21 above but 150 Sqmm.
All as per Item No.21 above but 120 Sqmm.
All as per Item No.21 above but 95 Sqmm.
All as per Item No.21 above but 70 Sqmm.
All as per Item No.21 above but 50 Sqmm.
S&F in replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL90CWEGLA or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of Integral LED security light luminaire 120W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL120CWEGLA or equivalent cat part of make as specified in list of make here-in-after.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 36,382.50 during AOC Note:- Tenderers shall not quote for this Schedule
narayan construction (BID ID -3214981)
M/s Chopra Constructions (BID ID -3213773)
KRISHNA ENGINEERING ENTERPRISES (BID ID -3209265)
M/S KHAN ENTERPRISES (BID ID -3209311)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .