EE ENM M6
DELHI JAL BOARD MU BLOCK PITAMPURA, DELHI-34
Retrofitting replacement of Schneider make soft starter and allied works of pump set no 3 at MU Block Pitampura BPS
2024_DJB_253116_7
NIT NO. 18(M-6)
Open Tender
Miscellaneous Works
Item Rate
60 days
EE ENM M 6
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹10,700
Yes
16 Feb 2024
3 Feb 2024
9 Feb 2024
3 Feb 2024
9 Feb 2024
3 Feb 2024
Supply of soft starter of ATS22 model reference NO. ATS22C41Q Make-Schneider
Replacement /installation of one soft starter of ATS22 model as per the details of work below :-a) Dismantling of the existing starter from the panel chamber after disconnecting all the mountings, cable connections ,bus bar connections /joints control connections and other works .proper cleaning of the panel chamber after removing of the starter .B) installation of the new starter complete in along with providing all material required and carrying out complete fixing work as per site requirement . C) Making the required provisions for the incomer supply to the new soft starter Making joints etc . with nut bolts and providing all the material as per site requirement
Making the required outgoing connections, form the soft starter to the motor/ pumps by connecting cables including replacing defected bus bar links if any as per requirement and making joints etc. and providing all the material as per site requirement. Checking and tightening of the cable connections at the motor side as per site requirement before restoration of power supply.
Configuration / control wiring of the new soft starters as below :-a) making of required control wiring connections , restoration of wiring of starter operating system with copper flexible wires etc as per site requirement . B) making the configuration for the starters for the starters for setting up of tripping range and other calibrations etc . as per the load and site requirement.
Dismantling the existing MCCB form the panel chamber after disconnecting all the joints/ connections. Providing and fixing of the new 630 amperes 3 pole MCCB as required for providing incoming supply to the soft starter including modification, providing base and other material for mounting the MCCB as per site requirement.
Making the required incoming bus bar connections to the incoming and outgoing side of MCCB including dismantling of existing bus bars, rearrangement of bus bars as suitable for the new MCCB with modification of existing, addition of new bus bars for replacing any defected links as per requirement, making joints etc and including providing all the material as per site requirement.
Testing and commissioning charges for the new starter, MCCB and complete motor starting system after above works including testing for the above works including testing for the functioning and operation as per site requirement.
Reconditioning of power supply system for existing starters / motors by checking and tightening of the cable connections at incoming and outgoing side of the of the existing switchgears, panel, soft starters and also cable connection at the motor side as per site requirement.
M/S HABRICK COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .