| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹63.2 L+₹13.8 L (28.0%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
7 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
PROVISION OF CERTAIN MAJOR REVENUE AND MINOR WORKS AT AIR FORCE STATION JALAHALLI AND AFTC
2024_MES_671796_1
8951/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
5 Nov 2024
4 Sept 2024
14 Oct 2024
4 Sept 2024
7 Oct 2024
18 Sept 2024
4 Sept 2024 - 11 Sept 2024
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl aii quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed.
M&L hard core broken stone of guage n exc 63mm deposited spread and levelled in llayers n exc 15 cm thick watered and rammed to a true surface all as specified and directed
M&L100 mm thick, Cement concrete 1:2:4, type B2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar work surface finished even and fair all as specified and directed.
M&L 75mm thick PCC type D-2 (1:4:8) using 40mm aggregate as in sub base to floor, surface finished even and fair complete all as specified and directed
Taking down cement plaster on stone wall etc including racking out of joints hacking for keys scrubbing down with water etc complete all as specified and directed.
M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with WPC 2%, finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specified and directed.
Supply only Integral waterproofing compound of approved make (ISI Maked) all as specified and directed.
M & L for preparation of new plastered surfaces and applying three coats of white wash on walls all as specified and directed.
M & L for preparation of new plastered surfaces of walls applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufactures instruction of required shade complete all as specified and directed.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4) complete all as specified and directed.
M & L for coloured Glazed ceramic tiles in vertical surface 350mmx250mm x7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering or bedding layer in cement mortar 1:3 complete all as specified and directed.
Material and labour for 25mm thick PCC (1:2:4) type B1 using 12.5mm graded stone agg as in levelling coarse under floor sub base surface all as specified & directed
M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of new steel surfaces of any description, not exc 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F for concertina coil of 610mm dia (in stretched position) hot deep galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed wire with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touch the bottom of barbed wire with the help of hog rings (14 SWG) complete all as specified and directed.
S&F in galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc complete all as specified and directed (each line wire to be measured)
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and including taking out old U/S steel/plastic/cpvc water tubing and connections including cleaning for refixing 15 mm/20mm dia all as specified and directed .
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down steel tubing complete all as specified and directed.
Supply and fixing 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe and all as specified and directed.
S&F in repairs of Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms) complete all as specified and directed.
Supplying and fixing of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified and directed.
Supplying and fixing of 20mm outer dia CPVC brass elbow all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St 240 complete all as specified and directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each all as specified and directed.
S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F Aluminium handles 150mm size, cast type, anodised all as specified and directed
S&F Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring fixed in floor overall length of cover plate 150mm long all as specified and directed .
S&F 100mm butt hinges stainless steel complete all as specified and directed.
M&L Preparation of new wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L Pre-cast PCC 1:3:6 type C1 (20 mm graded crushed stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 of any description as specified and directed.
M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed.
S & F mild steel work in framed brackets of angle or tees, C Channels, I sections with web flanges cut to shape, drilled and countersunk of screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc, 10 kg each bracket, and hanging also fastening and fixing complete conforming to Gde Fe 290, Gde E-165 complete all as specified and directed.
Cutting holes in stone/brick wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 all as specified and directed.
M&L submain wiring with two core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables size1.50 Sqmm and 1 run of 1.50 Sqmm PVC insulated multistrand Copper conductor cable (FRLS) of green colour for continious earthing drawn through surface PVC conduit of suitable size and with all accessories all as directed and specified.Make:- Havells/ Polycab/ Plaza
Supply and fix detector complying with and type certified to EN 45 addressable type multisensor detector with heat and smoke combination complete all accessories all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel)
Supply and fix addressable mannual call pointresettable type all accessories all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel)
Supply and fix addressable electronic sounder cum strobe type all accessories all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel)
Supply and installation ,programming and testing of fire control panel complying with BS EN 54 1 loop panel with max 40 detector Single loop Fire Alarm Control Panel 16X2 character blue crystal display complete all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel)
Supply and fixing of UPS 1000 VA minimum 30 min backup with wall mounted SS stand complete all as specified and directed.Make : APC / Microtech / Zebronics
Supply and Fixing wall mounted split units indoor/outdoor copper tubing in condenser unit including complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality 5 Star rating of capacity 1.5 TR all as specified and as directed.Make: Voltas/Bluestar/Hitachi
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA all as specified and as directed. Make :V-guard/Microtech/AE
Supply & Fixing of drain outlet PVC 15 mm dia pipe connected from rear side of AC upto drain with necessary clamp and fixtures on wall and floor all as specified and as directed.
Supply and fixing as of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and as directed.
Supply and fixing as of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and as directed.
Supply and fixing as of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and as directed.
Supply and fixing as of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and as directed.
Supply, errection, testing and commissioning raising and lowering type not less than 16 Mtr height high mast system shaft in two section suitable for 44m/s wind speed along with head frame, luminaire carriage suitable for upto 08 luminairies in symmetrical arrangement and other accessories manufactured in factory including raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box.HIGH MAST SYSTEM: Height of the mast not less than 16Mtr, Design standard PLG 07 of ILP, Basic Wind speed as per IS:875 Part III Design life - 25 yrs; Material construction as per S355 grade as per BSEN10 025; Base dia - 410mm & Top dia - 150mm; with plate thickness : Bottom - 3mm & Top - 3mm. Cross section of the mast shall be 20 side polygon with BS EN ISO 1461 standard galvanisation. With GI single spike lighting protection finial. The high mast shall have 8 nos of foundatino bolt with a PCD of 490mm of TS600 type with 30mm dia and 850mm length. Base plate with a dia of 570mm and thickness of 25mm LUMINAIRE CARRIAGE: Luminaire carriage shall be made of 50NB ERW class B MS Pipe with diameter of carriage ring at 535mm. Construction shall be with 8 arms which are welded and 2 sections capable of holding 08 luminairies. TRAILING CABLE: 5 core 2.5sq mm copper cable with EPR insulation and PCP sheathed. WINCH/POWER TOOL: Winch with double drum, SWL 750Kg integral motor with 1HP capacity with 6 pole, single speed. STAINLESS STEEL WIRE ROPE: Stainless Steel wire with AISI 304 grade and 7/19 construction with 2/3 wire rope of 6mm dia and a 2x2350Kg breaking load capacity including OEM recommendation electrical panel of both Auto and manual mode complete all as specified and directed. Make: Bajaj Model No: BHMRL16C or equivalent make in CG/Phillips.
Note: The rate quoted shall be inclusive of the following:- (a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set (b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings - 01 Job (c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer's design of foundation drawing as approved by GE. (d) Erection and commissioning of the high mast with the help of suitable equipment. (e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour. (f) Provision of Aviation obstruction light LED type. (g) Provision of lightening arrestor spike. (h) The Contractor shall submit OEM technical specification of High mast for approval of Accepting Officer before placing order. (j) The Contractor shall submit warranty & TC before claiming payments. (k) Provision of control panel for operation in both auto and manual mode, as per OEM specification..
Supply, errection, testing and commissioning raising and lowering type not less than 12 Mtr height high mast system shaft in two section suitable for 44m/s wind speed along with head frame, luminaire carriage suitable for upto 08 luminairies in symmetrical arrangement and other accessories manufactured in factory including raising lowering system comprising double drum winch, 5 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box.HIGH MAST SYSTEM: Height of the mast not less than 12 Mtr, Design standard PLG 07 of ILP, Basic Wind speed as per IS:875 Part III Design life - 25 yrs; Material construction as per S355 grade as per BS EN10 025; Base dia - 360 mm & Top dia - 100 mm; with plate thickness : Bottom - 3mm & Top - 3mm. Cross section of the mast shall be 20 side polygon with BSEN ISO 1461 standard galvanisation. With GI single spike lighting protection finial. The high mast shall have 4 nos of foundatino bolt with a PCD of 445 mm of TS600 type with 24 mm dia and 850mm length. Base plate with a dia of 520 mm and thickness of 25mm LUMINAIRE CARRIAGE: Luminaire carriage shall be made of 40 NB ERW class B MS Pipe with diameter of carriage ring at 450 mm. Construction shall be with 6 arms which are welded and 2 sections capable of holding 08 luminairies. TRAILING CABLE: 5 core 2.5sq mm copper cable with EPR insulation and PCP sheathed. WINCH/POWER TOOL: Winch with double drum, SWL 350 Kg integral motor with 0.75 HP capacity with 6 pole, single speed. STAINLESS STEEL WIRE ROPE: Stainless Steel wire with AISI 304 grade and 7/19 construction wire rope of 5 mm dia and a 2x1350 Kg breaking load capacity including OEM recommendation electrical panel of both Auto and manual mode complete all as specified and directed. Make: Bajaj Model No: BHMRL12B or equivalent make in CG/Phillips.
Note: The rate quoted shall be inclusive of the following:- (a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set (b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings - 01 Job (c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer's design of foundation drawing as approved by GE. (d) Erection and commissioning of the high mast with the help of suitable equipment. (e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour. (f) Provision of Aviation obstruction light LED type. (g) Provision of lightening arrestor spike. (h) The Contractor shall submit OEM technical specification of High mast for approval of Accepting Officer before placing order. (j) The Contractor shall submit warranty & TC before claiming payments. (k) Provision of control panel for operation in both auto and manual mode, as per OEM specification.
Note for Item No 54 & 56 here in above : (i) The earth work in any strata i.e. excavation,returning filling, removal , RCC foundation with foundation bolts manufactured from special steel with nuts, wahsers, anchor plate, template and Control panel deemed to be included in unit quoted rate. (ii) The M&L for LED flood light fittings will be measured and paid separately under relevant Schedule items.
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make : Philips/ Bajaj/CG
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponentSupply and fixing eatures :-
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor in and including rigid steel ERW concealed conduit and conduit accessories in wall, floors and ceiling including PTFE(Teailon) type sealing of joint along with continuous earth wire 1.5 Sqmm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including suitable standard accessories complete for one No. flame proof light point/ one fan point /one exhaust fan controlled by one way flame proof switch all as specified and directed. Make of Cable : Plaza/ Polycab/ Havells
S&F single pointed Copper Air Termination rod of 12mm dia 300mm long fixed to copper strip including drilling holes, nuts, bolts washers, insulating mounting pads for resting/supporting of air terminals etc.complete all as specified and directed.
S&F for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or on wall or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip (99.99 % molecularly copper) using porcelain clit/post insulators, complete all as specified and directed. Note: All Safety measure of technician to be responsible of the contractor.
S&F for test point terminal block made of copper strip of size 20 mm x 3 mm thick,of 200mm length (99.99 % molecularly copper) drilled and screwed , including required size of PVC junction box for protection of test point , complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6,16 A, single pole 250V all as specified and directed.Make : Sudhir/Bajaj/Baliga
Supply and fixing flame proof exhaust fan of sweep size 300 mm,single phase,230V including louvers and blades complete all as specified and directed.Make : Sudhir/Bajaj/Baliga
Material and labour for LED Flame proof junction box in LM6 upto 1" and upto 4 way complete all as specified and directed. Make : Sudhir/Bajaj/Baliga
Supply and install 4 Ton Tower AC units indoor and outdoor ,3 phase and twin roatry compressor complete with outdoor stand including cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality all as specified and directed.Make: Voltas/Blue star/Daikin
S&F Metal clad socket Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole 32-40 Amps and 415 volts MCB all as specified and directed.Make: L&T/Legrand/Indoasian
Material and labour for 25 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm fixed on walls, ceilings including all accessories for (Drain pipe ) all as specified and directed.
Supply and fixing of vertical TPN DB 6 Way with 63 Amps MCCB incommer,415 Volt conforms to IS 8623-1 & 3, IEC 61439-1 & 3 with provision for 3 pole and 4 Pole MCCB as incomer and SP/TP MCBs as outgoings IK 09-for double door DBs, Provided with insulated vertical phase bus-bars neutral bar with shroud,earth bar,sticking Saddles, cement spill protector,color-coded interconnecting wire set cable ties blanking plates and circuit identification labels etc all as specified and directed.Make: L&T/Legrand/Indoasian
Supply and fix MCCB 125 Amps, 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed.Make: L&T/Legrand/Indoasian
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 4 runs of 6 Sqmm cable along with two run of 6 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza
Supply and fixing 415V 10KA 'C' curve, 32-40 Amp TP miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning complete all as specified and directed.Make: L&T/Legrand/Indoasian
S&F for Fe 410-W (Gde E- 250) qualityA Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) for keep indoor unit all as specified and directed by Engineer in Charge.
Supply and fixing of copper tube with insulation for refrigerant of 3/4" dia suitable for tower ACs complete all as per OEM and all as specified and directed.
Supply and fixing of copper tube with insulation for refrigerant of 3/8" dia suitable for Tower ACs complete all as per OEM and all as specified and directed.
Material and labour for 4 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian
Supply and fix detector complying with and type certified to EN 45 addressable type smoker detector combination complete all accessories all as specified and as directed.Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)
Supply and fix detector complying with and type certified to EN 45 addressable type Heat detector combination complete all accessories all as specified and as directed.Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)
Supply and installation ,programming and testing of fire control panel complying with Morley DXc4 4 loop fire alarm per loop 198 addressable points 99 dectors plus 99 device per loop 6*40 charactor blue crystal display with backlight illumination 2 sounder circuit PT requires network card MOF795099 additionnally for network complete all as directed.Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)
Supply and fix loop driver card for morley IAS protocal 460 mA complete all accessories all as specified and as directed. Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)
Supply and fixing of 12 V 7AH Battery complete all as directed.Make Exide/Amron/SF Sonic.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit 20 mm dia or higher and conduit fittings and accessories including one green colour 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS grade as earth wire up to common earth and connected to earth dolly complete for for following all as specified and directed. Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note:- GI metal flush box for modular switches and inner plate and outer plate for modular switch , cutting chases for conduits and sinking's for boxes and making good to walls, floors etc. in recessed or concealed conduit wiring shall be include in the quoted rate.
a) One light point controlled by one switch one way 5 Amps
b) One switch socket 5 pin 5 Amps flush type on independent board.
c) One switch socket 5 pin 5 Amps flush type on same board.
d) One exhaust fan point controlled by one switch
All as per item No 85 above but with 2.5 Sqmm FRLS cable for one socket 5 pin 15Amps flush type on independent board with including earthwire.
All as per item No 85 above but with 4.0 Sqmm FRLS cable for one socket 5 pin 15Amps flush type/Metal clad switch on independent board with including earthwire complete.
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed.. Make :Legrand/ Crabtree/ Anchor
Supply and Fix modular Socket, 6A - 3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and Fix modular Socket, 16A - 3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply and fixing exhaust fan, heavy duty with steel louvers, double ball bearing. silent operation, steel body and blades with fixing arrangements of size 300 mm sweep, 1400 rpm, 230/240V single Phase . Make Havells / Bajaj/CG/Usha.
M&L for cutting of hole through cement mortar brick stone wall including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus,rubbish to a distance not exceeding 50 mtrs including fixing of exhaust fan of size 250-300 mm all as specified and as directed.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 32 Amps . Make: L&T/Legrand/Indoasian
Supply fixing, connection and testing MCB SP 6-32 Amps ,240 V , 10 KA ,'C' series all as speified and directed.Make: L&T/Legrand/Indoasian
M&L submain wiring with two single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables 4 sqmm and 1 run 4 Sqmm PVC insulated multistrand copper conductor cable (FRLS) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories all as all as specified and directed. Make:- Havells/ Polycab/ Plaza ( Note: Three runs of 4 sqmm copper conductor and one run of surface PVC conduit of suitable size with all necessary fixing accessories and making good disturbed surface shall be measured as one length.)
M&L Pedastal fan 500 mm sweep ,high velocity heavy duty metal body continuous duty , double ball bearing. silent operation, blades 1350 rpm, 240V all as specified and as directed. Make Havells / Bajaj/CG/Usha.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM will be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xix) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Material and labour for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Squre Bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone agreegate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 250X300X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black beground with white and complete all as specified and as directed by Engineer-in -charge.
Excavation in trenches for foundation laying under ground cable, errection of poles manholes, sewage pipe line and stays etc. in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed.
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for paymet.
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polythylene including coupler & bend with smooth internal profile external surface for non pressue under ground cable complete all as specified and as directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Material and labour for 3.5 core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian
M & L for UG cable route indicator made out of 100 mm dia MS plate with 20 mm dia 50cm long MS bar as legs for writing LT and name of feeder fixing with and including necessary PCC 1:2:4 in grouting route all as directed by Engr in Charge.
Supply and Fixing bracket made of GI pipe of size 32 mm dia and 60 cm long including two No. of GI clamp fixed on wall with GI flash nut of suitable size complete all as specified and as directed.
Supply and fix of 36 watts, 230 V LED building security light fitting with light sensor with connected items complete for made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance complete all as specified and as directed.Make: Bajaj/Phillips/CG
Taking down of indoor and outdoor unit of split type AC of 1.5/2 TR capacity from old place and fixing the same after servicing at New building and reconnect the suction and discharge refrigerant pipe line, electrical connection between indoor and outdoor unit making suitable fixing arrangement as required , necessary testing and commissioning complete all as specified and as directed.
Supply and fixing of Stand Condenser motor in outdoor unit for 1.5/2 TR AC of existing place complete all as specified and as directed.
S & F on load change over switch 4 pole 200 Amps in sheet metal enclosure complete all as specified and as directed. make :- Havells /L&T/Indoasian.
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 4 mm thick, by means of GI strip made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, cover slab 50 mm thick of required size with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering, funnels, wire mesh and provid charcoal or coke alternative layers of 15 cm including necessary earth work complete all as shown in electrical plated No 3 and tesing complete all as specified and as directed.
Supply and installation ,programming and testing of fire PLC control panel complying with BS EN 54 1 loop panel with 99 detector & 99 module DXc1 Single loop Fire Alarm Control Panel two loop card inbuild198 addressable points 99 detectors Plus 99 devices per Loop 6*40 character blue crystal display with backlight 11 devices per Loop 6*40 character blue crystal display with backligh illumination 2 Sounder circuits PT requires network card MOF795099 additionally for netwok complete all as specified and as directed.Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out ,returning,filling in and ramming earth or broken rubble mixed with earth, in layers n exc 25 cm in hard/dense soil,watering and removing surplus soil to a distance n exc 50 m and making good surface all as specified and as directed.
M&L Cement Concrete type C2 1:3:6 (using 40 mm graded stone aggregate) as in foundation, fillings, for posts and mass,concrete complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5 mtr depth for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 Sqm on plan for sewage pipe line and manhole etc and getting out in any type of soil all as specified and as directed.
S & F mild steel plate (plain or chequered) channels, square cut or notched (ordinary or counter sunk), forming holes with riveted, bolted or welded attachement etc. and hanging also fastening and fixing complete conforming to Gde Fe 410 W (Gde E-250 Quality A) complete all as specified and directed.
M&L 15 mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete etc finished even and smooth without using extra cement complete all as specified and as directed.
M&L Providing precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate, set in CM 1:4 as in cover slab and similar work incl necessary formwork complete all as specified and directed
M&L TMT bars 10 mm dia and above , cut to length ,bent to shape required , including cranking , bending , spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and directed
Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in soft/loose soil complete all as specified and directed
S & F PVC(SWR) pipe single socketed , in any length with rubber rings joints of 110 mm bore, laid in trench or in floors complete all as specified and directed.
S & F PVC(SWR) pipe single socketed , in any length with rubber rings joints of 75 mm bore,fixed to walls complete all as specified and directed.
S&F PVC bends of approved make of (any radius) with duck’s foot or heel rest of 75 mm bore complete all as specified and directed
M & L salt glazed stone ware drain pipes of internal dia 150 mm bore grade 'A' laid in trenches and jointed incl demolition and breaking up old drain pipe (salt glazed stoneware drain pipe) set in cement concrete, internal dia 150 mm complete all as specified and as directed.
M&L for concrete bed to drain pipe including packing under and hunching against the side of drain pipe after they are laid and tested in PCC 1:3:6 type C-2 for 150mm dia pipe all as specified and directed . Note :- An amount of Rs 250.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
ELAN ENGINEERS (BID ID -3131730)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .