Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹25.7 L+₹1.8 L (7.69%)Rejected-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹27.3 L+₹3.4 L (14.4%)Rejected-AOC NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹28.4 L+₹4.5 L (19.0%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹47.1 L+₹23.2 L (97.3%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
| Sl No | Description | Qty | Unit | PRIYADARSHINI CONSTRUCTIONS L3 | M/S JANAKI ENTERPRISES L5 | GS TRADERS L2 | Vasavi Electricals L1 | RAMSON TRADERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including making good the disturbed surfaces to match with adjoining surfaces complete all as specified and as directed. | 1,077 | Per Point | 15 ₹16,155 | 630 ₹6,78,510 | 15 ₹16,155 | 10 ₹10,770 Lowest | 20 ₹21,540 |
| 2.00M & L for Point Wiring with single core PVC insulated unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including M S terminal boxes fabricated with 1.6 mm thick M S sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed :- | ||||||||
| 2.10 | One light / fan point controlled by one switch | 165 | Per Point | 725 ₹1,19,625 | 50 ₹8,250 Lowest | 575 ₹94,875 | 550 ₹90,750 | 800 ₹1,32,000 |
| 2.20 | One light point controlled by two way switch | 20 | Per Point | 825 ₹16,500 | 65 ₹1,300 Lowest | 650 ₹13,000 | 650 ₹13,000 | 890 ₹17,800 |
| 2.30 | One 3 pin socket out let 5 Amps on independent board | 145 | Per Point | 725 ₹1,05,125 | 50 ₹7,250 Lowest | 575 ₹83,375 | 500 ₹72,500 | 800 ₹1,16,000 |
| 2.40 | One 3 pin socket out let 5 A on same board | 24 | Per Point | 200 ₹4,800 | 55 ₹1,320 Lowest | 100 ₹2,400 | 100 ₹2,400 | 160 ₹3,840 |
| 2.50 | One Bell / Buzzer Point controlled by bell push | 6 | Per Point | 750 ₹4,500 | 230 ₹1,380 Lowest | 575 ₹3,450 | 500 ₹3,000 | 800 ₹4,800 |
| 3.00 | M & L for Point Wiring with single core PVC insulated unsheathed FRLS multi stranded with copper conductor 2.5 Sqmm cable 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including M S terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. | 74 | Per Point | 800 ₹59,200 | 710 ₹52,540 | 700 ₹51,800 Lowest | 750 ₹55,500 | 890 ₹65,860 |
| 4.00 | S & F in repairs Sub main wiring with 2 runs single core 6 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.
(Note : Three run of 6sqmm cable and one run of conduit pipe altogether measured as one unit) | 1,080 | RM | 180 ₹1,94,400 Lowest | 350 ₹3,78,000 | 290 ₹3,13,200 | 250 ₹2,70,000 | 360 ₹3,88,800 |
| 5.00 | S & F in repairs Sub main wiring with four runs single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.
(Note : Five run of 4sqmm cable and one run of conduit pipe altogether measured as one unit) | 160 | RM | 140 ₹22,400 Lowest | 410 ₹65,600 | 185 ₹29,600 | 220 ₹35,200 | 520 ₹83,200 |
Tender Value
₹33.7 L
EMD Value
₹67,400
Closing Date
23 Feb 2026, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101 DICKENSON ROAD, BANGALORE-560042
SPECIAL REPAIR TO INTERNAL WIRING OF BLDG NO P-341 (400 MEN) KANKAYYA COY AT TRG BN-I MEG AND CENTRE AND PROVN OF GEYSER IN BATHROOM OF JCO AND OR LIVING ACCN UNDER GE (NORTH) BANGALORE
2026_MES_750991_1
86480/E8
Open Tender
Civil Works - Others
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹67,400
21 May 2026
2 Feb 2026
2 Mar 2026
2 Feb 2026
23 Feb 2026
16 Feb 2026
2 Feb 2026 - 9 Feb 2026
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including making good the disturbed surfaces to match with adjoining surfaces complete all as specified and as directed.
M & L for Point Wiring with single core PVC insulated unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including M S terminal boxes fabricated with 1.6 mm thick M S sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed :-
One light / fan point controlled by one switch
One light point controlled by two way switch
One 3 pin socket out let 5 Amps on independent board
One 3 pin socket out let 5 A on same board
One Bell / Buzzer Point controlled by bell push
M & L for Point Wiring with single core PVC insulated unsheathed FRLS multi stranded with copper conductor 2.5 Sqmm cable 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including M S terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
S & F in repairs Sub main wiring with 2 runs single core 6 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed. (Note : Three run of 6sqmm cable and one run of conduit pipe altogether measured as one unit)
S & F in repairs Sub main wiring with four runs single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed. (Note : Five run of 4sqmm cable and one run of conduit pipe altogether measured as one unit)
S & F in repairs Sub main wiring with four runs single core 10 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 10 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed. (Note : Five run of 10sqmm cable and one run of conduit pipe altogether measured as one unit)
Note for Item No 2 & 6 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the quoted rate (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in the quoted rate (v) Cost of a cutting chases deemed to be included in the quoted rate
All as per item No 2 herein before but concealed wiring drawn through existing PVC conduit :-
One light point controlled by one switch
One fan/Exhaust point controlled by one switch/regulator
One light point controlled by 2 way switch
One 3 pin socket out let 5 Amps on independent board
One 3 pin socket out let 5 A on same board
S&F LED batten with luminaire suitable for indoor applications 20 Watts, 4 feet long with extruded aluminium housing & integrated LED channel with all accessories all as specified and directed.
S & F Switch Piano flush type, single pole, one way 5Amps all as specified and directed.
S&F Switch piano flush type, single pole, two way 5Amps all as specified and directed.
S&F stepped type electronic fan regulator, flush type Switch / socket type all as specified and as directed
S&F Switch socket combination 2 in 1 , 5 Amps flush type all as specified and as directed
S&F switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
S&F in repairs MCB SPN 240 volts 32/40 Amps, C curves complete all as specified and as directed
S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps, C curves complete all as specified and as directed
S&F in replacement of MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F Storage type electric water heater 25 Ltrs capacity, steel body with copper inner tank and heating element upto 2 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let water etc., testing for smooth functioning at site including taking down of old unserviceable geyser and deposited to MES yard complete all as specified and directed
S&F in repairs MCB Distribution board, TPN 4 way, double door type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in replacement of MCB Distribution board, VTPN 4 way double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F in replacement of MCB TPN 415 volts 10 KA, 'C' curves 100 Amps capacity complete all as specified and as directed
S&F in replacement of MCB TPN 415 volts 10 KA 'C' curves 40 Amps capacity complete all as specified and as directed
S&F in replacement of MCB Distribution Board SPN 4 way, double door type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals 240 volts all as specified and as directed
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in Reincorced cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point etc including dismantaling old unserviceable earthing etc., complete all as specified and as directed
Supply and fixing in repairs LED bldg security light fitting 30 Watts capacity with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection with and including GI Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc duly applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix Exhaust fan 300mm sweep, steel body, AC single Phase 230Volts with, blades and frame, louvers complete including necessary core cutting in block/brick masonary for installation all as specified and directed .
Supply and fix Exhaust fan 450mm sweep, steel body, AC single Phase 230Volts with, blades and frame, louvers complete including necessary core cutting in block/brick masonary for installation all as specified and directed .
S&F Storage type electric water heater 25 Ltrs capacity, steel body with copper inner tank and heating element upto 2 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let water etc., testing for smooth functioning at site complete all as specified and directed
S&F Storage type electric water heater 50 Ltrs capacity, steel body with copper inner tank and heating element upto 3 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let water etc., testing for smooth functioning at site complete all as specified and directed
M & L for Galvanised iron tubes 15mm dia bore, Medium grade, with all fitting, laid in trenches complete all as specified and directed
Cutting existing steel tubing for alterations or additions of size 15mm/20mm complete including screwing etc all as specified and directed (Each cut measured)
M & L for Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm dia bore or for brass ferrule and fixed all as specified and directed
M & L for Stop valves fancy type, cast copper alloy chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe15mm dia bore or for unions and fixed all as specified and directed
S&F Singl epole neutral enclosure 20 Amps 240volts with two pin & earth plug & socket wit one MCB SP 20Amps, C curves complete all as specified and as directed
S&F MCB SPN 240 volts 32/40 Amps, C curves complete all as specified and as directed
S&F MCB single pole 240 volts 32 Amps, C curves 230volts complete all as specified and as directed
S & F in repairs Sub main wiring with two runs single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed. (Note : Three runs of 4sqmm cable and one run of conduit pipe altogether measured as one unit)
S&F MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning under and above the cable for protection all as per Para 19.75 SSR Part-I complete all as specified and as directed (Note : Punned thickness will be measure for payment)
Supply & Laying sub class 'B' burnt bricks for cable protection complete all as specified as directed
Supply & Laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor cable connected with suitable legs including taking out the existing unserviceable cable for following size :-
3.5 C x 25 Sqmm
3.5 C x 35 Sqmm
3.5 C x 120 Sqmm
Supply, testing and commissioning of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size,
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and including galvanized iron strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in Reiforced cement concrete (1:2:4) type B1 with 8 mm TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_841104.xls
BOQ • 3.22 MB
tender86480.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .