| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.0 L+₹3,770 (0.34%)Rejected-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹11.3 L+₹37,180 (3.40%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹11.5 L+₹51,530 (4.71%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Jul 2020, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR/MAINT OF CEILING, EXHAUST FANS AND FRESH AIR FANS OF TOILETS AT LGJ MIL STN
2020_MES_337890_2
8931-05/20-21
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E cat (b) (i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹20,000
Yes
5 Sept 2020
11 May 2020
6 Jul 2020
11 May 2020
3 Jul 2020
19 May 2020
Amount
Material & Labour for dismantling the ceiling fan of sweep 1200 mm (48 inch) of any make/model, cutting and removing the old defective/burnt winding, cleaning the core of the fan motor, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation and re-assembling the fan including testing complete all as specified and as directed by Engineer-in- Charge. Make for winding wire :- Devidyal/HTP Thulax/Chetak Note:- All defective/ unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
Material & Labour for dismantling the ceiling fan of sweep 1400 mm (56 inch) of any make/model, cutting and removing the old defective/burnt winding, cleaning the core of the fan motor, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation and re-assembling the fan including testing complete all as specified and as directed by Engineer-in- Charge. Make for winding wire :- Devidyal/HTP Thulax/Chetak Note :- All defective/ unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
Material & Labour for dismantling the exhaust fan of sweep 450 mm of any make/model, cutting and removing the old defective/burnt winding, cleaning the core of the fan motor, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation and re-assembling the fan including testing complete all as specified and as directed by Engineer-in- Charge. Make for winding wire :- Devidyal/HTP Thulax/Chetak Note :- All defective/ unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
Material & Labour for dismantling the exhaust fan of sweep 375/380 mm of any make/model, cutting and removing the old defective/burnt winding, cleaning the core of the fan motor, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation and re-assembling the fan including testing complete all as specified and as directed by Engineer-in- Charge. Make for winding wire :- Devidyal/HTP Thulax/Chetak Note :- All defective/unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
Material & Labour for dismantling the exhaust fan of sweep 300 mm of any make/model, cutting and removing the old defective/burnt winding, cleaning the core of the fan motor, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation and re-assembling the fan including testing complete all as specified and as directed by Engineer-in- Charge. Make for winding wire :- Devidyal/HTP Thulax/Chetak Note :- All defective/unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
Supply and Fixing in replacement rubber reel including suitable size of bolt, nut and safety pin for ceiling fan of any make/size/model complete all as specified and as directed by Engineer-in- Charge.
Supply and Fixing in replacement ball bearing of No. 6201 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
Supply and Fixing in replacement ball bearing of No. 6202 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
Supply and Fixing in replacement ball bearing of No. 6203 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
Supply and Fixing in replacement ball bearing suitable for exhaust fan (any sweep and type) complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/INA/FAG/NSK
Supply and Fixing in replacement Gunmetal bush suitable for ceiling/ Exhaust fan (any sweep/make/model) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement mild steel clamp including rubber reel, steel nut bolt, split pin heavy duty and lock clamp suitable for ceiling fan of any type, make and sweep complete all as specified and directed by Engineer-in- Charge.
Supply and fixing in replacement threaded mild steel hanging shaft/rod (heavy duty, 30cm to 45cm long) suitable for ceiling fan of any type, make and sweep complete all as specified and directed by Engineer-in- Charge.
Supply and fixing in replacement capacitor/condenser of size 2.5 Mfd for fan motor including making necessary connections and testing complete all as directed by Engineer-in-charge. Make :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens
Supply and fixing in replacement capacitor/condenser of size 3.15 Mfd for any fan motor/exhaust fan motor including making necessary connections and testing complete all as directed by Engineer-in-charge. Make :- Epcos/Tesla/Asian/MTC/Usha
Supply & fiixing only in replacement of capacitor/condenser of size 4 Mfd for fan motor including making necessary connection and testing complete all as directed by Engineer-in –Charge. Make :- Epcos/Tesla/Asian/MTC/Usha
Supply and Fixing in replacement connection lead consisting of PVC unsheathed round, PVC insulated 03 ( three) core flexible copper wire of size 14/0.0076 for making the connection from ceiling rose to ceiling fan/exhaust fan complete all as specified and as directed by Engineer-in- Charge. Make of cable: Kalinga/Usha/Paragon/ Finolex / Standard/Havells/Plaza
Supply and Fixing in replacement bottom cover made of PVC suitable for ceiling fan of sweep 1200 and 1400mm of any make complete all as specified and directed by Engineer-in- Charge
Supply and Fixing in replacement fan blade set suitable for exhaust fan of sweep 450mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade set suitable for exhaust fan of sweep 300mm to 380mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade set suitable for ceiling fan of sweep 1200mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade set suitable for ceiling fan of sweep 1400mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Material and labour for painting to exhaust Fan of any sweep/size/make, checking nut bolts and replace if required, painting the fans (at store yard of AGE E/M or as per direction of Engineer-in-charge) complete including fan body, blades etc. with synthetic enamel Black/Grey paint by spray gun after cleaning all dust / spoil and greasy spots and including using filler for filling cavities. After painting, MES No. shall be marked with red colour synthetic enamel paint using stencil as per existing No. complete all as specified and as directed by Engineer-in-charge.
S&F in replacement if fan motor exhaust fan/ air fresher, cooper wound 300mm sweep, single phase 230v AC supply including replacement of rubber pads and making necessary connection complete all as specified and directed by Engineer in Charge. Make : Crompton Greaves/ GEC/Nelco/American universal/Khaitan/Cool home.
Material and labour for painting to ceiling Fan of any sweep/size/make, checking nut bolts and replace if required, painting the fans (at store yard of AGE E/M or as per direction of Engineer-in-charge) complete including fan body, blades, canopies etc. with synthetic enamel white/Black/Grey paint by spray gun after cleaning all dust / spoil and greasy spots and including using filler for filling cavities. After painting MES No. shall be marked with red colour synthetic enamel paint using stencil as per existing No. complete all as specified and as directed by Engineer-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Singla Electricals
Soma Enterprises
NATIONAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .