Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.1 L+₹3.6 L (14.0%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹31.4 L+₹5.8 L (22.8%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹32.2 L+₹6.7 L (26.1%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹32.8 L+₹7.2 L (28.2%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
20 Mar 2021, 6:00 pmClosed
ARJUN PATRO IDSE
GE U ELECTRIC SUPPLY DELHI CANTT
REPAIR AND MAINTENANCE OF STAND BY DIESEL ENGINE PRIME POWERED ALTERNATORS ALONG WITH CONNECTED SWITCH GEARS AT HQ DELHI AREA ARJAN VIHAR C COMD HUT W COMD HUT S COMD HUT ARTY MESS SCADA CENTRE N COMD HUT RRRC MES IB STN WKSP 1 WEC 1WEEEETSU AND CA
2021_MES_422436_1
GE ELECT/D-107/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE U ELECTRIC SUPPLY
₹96,400
Yes
10 Apr 2021
19 Feb 2021
22 Mar 2021
20 Feb 2021
20 Mar 2021
5 Mar 2021
Amount
Manning & opreation and general Daily / weekly maintenence of Diesel Engine driven Alternators of any make/brand having out put of different KVA (manning, running, opreating round the clock in shift continously including Sunday & holidays unless stated otherwise against individual items) installed at the under mentioned locations. (a) HQ Delhi Area (DG set of capacity 62.5 KVA-2 No & 75 KVA -1 No) Cassel Road (DG set of Capacity 160 KVA) and MES IB (DG set of capacity 62.5 KVA & 30 KVA 1 No Each) - 03 shifts (i) 1 st shift from 0600 hrs to 1400 hrs one skilled FGM (ii) 2nd shift from 1401 hrs to 2200 hrs one skilled FGM (iii) 3rd shift from 2201 hrs to 0600 hrs one skilled FGM (b) WEE /1 WEC/EETSU (DG set of capacity 30 KVA , 250 KVA -02 No Each, 80 KVA-01) - 03 shifts (i) 1 st shift from 0600 hrs to 1400 hrs one skilled FGM (ii) 2nd shift from 1401 hrs to 2200 hrs one skilled FGM (iii) 3rd shift from 2201 hrs to 0600 hrs one skilled FGM
Note : (i) The contractor will ensure suitable replacement of Gent Operator while on leave/weekly rest. (ii) The Operator should have preferably working experience, educational & Technical/working experience certificate of Tradesman should be submitted and shall ensure that 01 Gent Operator always be present in each shift. In case of absence of any Gent Operator penalty @ Rs 100.00 per Hour per Gent Operator shall be imposed on the contractor. (iii) The contractor shall ensure that all stations (as mentioned Srl item No. (1.10) to (1.40) are in proper working/functioning condition. if any item is required for proper functioning of the system the contractor shall inform to concerned JE/AGE/GE immediately via telephone and in wiriting, and shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , lawn, garden, outside the bay yard , hard standing , footpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegetation will be arranged by contractor without any extra cost. (iv ) The contractor shall provide dress with jacket – 02 Nos to all the electricians employed by him as per sample approved by GE,First Aid box including required Medicines,necessary log books and other stationeries as per installation manning demand the cost of the same shall deemed to be included in the unit rates of item Srl No. 1 here- in- before.
Worker's wage per person per day (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
M&L for carrying out "B" check for the following Diesel Engine Driven Generator sets of Make: Cummins/Kirlosker/Ruston/Graves/M&M/Ashok leyland as per manufacturer recommendation/ particular specification including replacement of required necessary spares and Replacement of Filters such as Fuel filter ,SLO By Pass Filter and lub oil filter complete sets along with rectification of minor defects, and cleaning of air filters/ breather,coolant tank with Blower and labour for filling/topping up and replacement of Engine oil/coolant and tuning of engine for DG set as listed below all as specified and directedr Note (i) Rate Quoted includes the cost of distilled water for batteries,and minor acessories such as nuts and bolts O rings (ii) Engine Oil and Coolant shall be measured and paid under relevant Item.
200 KVA Capacity Make:Cummins Model QSB 6.7G at NCC Parade Camp
200 KVA capacity Make: Kirloskar at Arty Mess
200 KVA capacity Make:Graves Model GP W11-200 at HQ Delhi Area mess
250 KVA capacity Make:Kirloskar Model KG-284L1 at 1 WEC
160 KVA capacity Make:Graves Model GP W11-160 at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Cassel Road
125 KVA capacity Make:cummins Model 6BTAA59-613 at Cassel Road.
100KVA Capacity Make:Kirloskar at Stn WKSP EME
100KVA Capacity Make:Greaves model as per existing at RRRC
80 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at EETSU
75 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at Delhi HQ Area
62.5 KVA Capacity Make: Greaves Model 4G11TGI at Delhi HQ Area.
62.5 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at 1WEE.
62.5 KVA Capacity Make: Kirloskar Model 4R1040T at CC Hut/WC Hut.
40 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at Scada.
30 KVA Capacity Make: Kirloskar at 1WEC
30 KVA Capacity Make: Cummins ar Model at NC Hut
30 KVA Capacity Make: Greaves Model at MES IB
7. 5 KVA Capacity Make: Kirlosker Model as per existing at RRRC
Labour Only for Replacement/ Topup of engine oil 15w 40 make: Servo/volvoline/Castrol Note : Engine Oil shall be issued under Sch 'B'
Supply only the coolant 5 liter container for cummins engines Cat No. 3167217 of Cummins / Fleet guard / approved make of OEM
Supply only pre mix coolant 5 liter container Cat No. CC2653 of Fleet guard / Cummins approved make of OEM
Supply only K cool super plus engine coolant of 5 liter can for kirloskar /M&M/Greaves Engine Make:K cool super plus or recommended by the OEM
Disconnecting and taking down unserviceable battery terminal and S&F battery terminal brass heavy duty.complete suitable for fixing on battery poles with nuts and bolts complete all as specified and directed.
M&L for carrying out "D" check for the following Diesel Engine Driven Generator sets of Make: Cummins/Kirlosker/Ruston/Graves/M&M/Ashok leyland as per manufacturer recommendation/ particular specification including replacement of required necessary minor spares such as'o' Ring, washer to avoid leakages spares and Replacement of Filters such as Fuel filter ,SLO By Pass Filter and lub oil filter along with top head gaskit,roker head gaskit adjustment of the Rockar arms runnuing, tappets setting with ferule guage complete sets along with rectification of minor defects, and cleaning of air filters/ breather,coolant tank with Blower and labour for filling/topping up and replacement of Engine oil/coolant and tuning of engine for DG set as listed below all as specified and directed Note (i) Rate Quoted includes the cost of distilled water for batteries,and minor acessories such as nuts, bolts O rings and gaskits of the engine.
200 KVA Capacity Make:Cummins Model QSB 6.7G at NCC Parade Camp
200 KVA capacity Make: Kirloskar at Arty Mess
200 KVA capacity Make:Graves Model GP W11-200 at HQ Delhi Area mess
250 KVA capacity Make:Kirloskar Model KG-284L1 at 1 WEC
160 KVA capacity Make:Graves Model GP W11-160 at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Cassel Road
125 KVA capacity Make:cummins Model 6BTAA59-613 at Cassel Road.
100KVA Capacity Make:Kirloskar at Stn WKSP EME
100KVA Capacity Make:Greaves model as per existing at RRRC
80 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at EETSU
75 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at Delhi HQ Area
62.5 KVA Capacity Make: Greaves Model 4G11TGI at Delhi HQ Area.
62.5 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at 1WEE.
62.5 KVA Capacity Make: Kirloskar Model 4R1040T at CC Hut/WC Hut.
40 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at Scada.
30 KVA Capacity Make: Kirloskar at 1WEC
30 KVA Capacity Make: Cummins ar Model at NC Hut
30 KVA Capacity Make: Greaves Model at MES IB
7. 5 KVA Capacity Make: Kirlosker Model as per existing at RRRC
M&L for supply and fixing aganist repairs stop soleniod/ shut off valve of capacity 250 KVA DG Sets of any MAKE along with screen Filter including wiring connecting to panel circuit, starting and testing on load complete all as specified and directed. Make: As Per OEM Recommendation
Reapirs/ servicing to the stop Solinoid coil of capacity 12/24 Volt connected to the DG set of varoius capacity 200 to 30 KVA / any Makes including replacement of defective parts including winding complete all as specified and directed.
M&L for to carry out repairs to self starter by replcement of defective armature , field coils carbon brushes, soliniod, bearings reassembling the same and testing complete suitable for 24 volts/12 volts operation all as specified and directed
M&L for to carry out repairs to 12/24Volt Alternator/dynamo by replacement of carbon brush, electronic regulator / rectifier, bearings reassembling the same and testing complete all as specified and directed.
M & L for complete replacement of Governor gaskit for 250 KVA Dg set of Kirloskar engine complete testing and commissioning complete all as specified and directed
Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture's guide lines for DG Set of various capacity any make form 30 KVA any makeincluding replacement of worn out and unserviceable Ó'rings /shutt off valve/Plungers complete all as specified and directed
M & L for complete replacement of Governor Barrle plunger for 250 KVA Dg set of Kirloskar engine complete testing and commissioning complete all as specified and directed
M & L for complete replacement of Turbo repair kit for 250 KVA Dg set of Kirloskar engine complete testing and commissioning complete all as specified and directed
Supply and fixing in replacement of Motorized Change Over for AMF panel of Dg set capacity 30 KVA to 100 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets of Make: Cummins/ Kirloskar /M&Mahindra /Greaves
Supply and fixing in replacement of Motorized Change Over for AMF panel of Dg set capacity 125 KVA to 320 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets of Make: Cummins/ Kirloskar /M&Mahindra /Greaves
Supply and fixing in replacement of the defective power contactors of the DG sets Panal of 220V, 50Hz supply, 4 pole 125A.
Supply and fixing in replacement of the defective power contactors of the DG sets Panal of 220V, 50Hz supply, 4 pole 200A.
Supply and fixing in replacement of the defective power contactors of the DG sets Panal of 220V, 50Hz supply, 4 pole 315A.
Material and labour for complete replacement of Flexible Metal / Reinforced Rubber House Sets comprising of engine oil lubrication house, fuel houses and Coolent.water House for DG set of Capacity 30 KVA -125KVA Make : Kirloskar /Greaves/M&M /Cummins complete with necessry acessories, O rings and connectors complete set all as specified and direcetd.
Material and labour for complete replacement of Flexible Metal / Reinforced Rubber House Sets comprising of engine oil lubrication house, fuel houses and Coolent.water House for DG set of Capacity 160 KVA - 250 KVA Make : Kirloskar /Greaves/M&M /Cummins complete with necessry acessories, O rings and connectors complete set all as specified and direcetd.
M & L for cleaning radiator intercooler by checking and removing the deposted dusts, oil welt and carbons and cleaning with forced water with cleaning chemicals and testing from leaks at inter connectors / couplers / flexible connectors/ flexi clamps and making necesssry minor repairs to avoid leakages of coolent in the following DG sets all as specified and directed by Engineer-in-charge
200 KVA Capacity Make:Cummins Model QSB 6.7G at NCC Parade Camp
200 KVA capacity Make: Kirloskar at Arty Mess
200 KVA capacity Make:Graves Model GP W11-200 at HQ Delhi Area mess
250 KVA capacity Make:Kirloskar Model KG-284L1 at 1 WEC
160 KVA capacity Make:Graves Model GP W11-160 at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Arjan Vihar
160 KVA capacity Make:Cummins Model QSB5.9 G at Cassel Road
125 KVA capacity Make:cummins Model 6BTAA59-613 at Cassel Road.
100KVA Capacity Make:Kirloskar at Stn WKSP EME
100KVA Capacity Make:Greaves model as per existing at RRRC
80 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at EETSU
75 KVA Capacity Make: Cummins Model 4TBAA3.9G4 at Delhi HQ Area
62.5 KVA Capacity Make: Greaves Model 4G11TGI at Delhi HQ Area.
62.5 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at 1WEE.
62.5 KVA Capacity Make: Kirloskar Model 4R1040T at CC Hut/WC Hut.
40 KVA Capacity Make: Cummins Model 4TBAA3.3G11 at Scada.
30 KVA Capacity Make: Kirloskar at 1WEC
30 KVA Capacity Make: Cummins ar Model at NC Hut
30 KVA Capacity Make: Greaves Model at MES IB
7. 5 KVA Capacity Make: Kirlosker Model as per existing at RRRC
Supply and fixing in replacement of V belts for radiator fan / main shaft/ cam shaft for the DG set of capacity 30 KVa -125 KVA as per existing .size and model complete all as specified and direceted.Make dunlop/yule
Supply and fixingin replacement of V belts for radiator fan / main shaft/ cam shaft for the DG set of capacity 160 KVa -250 KVA as per existing .size and model complete all as specified and direceted Make dunlop/yule
M & L for supply and fixing against repairs Automatic Voltage Regulator suitable for 250 KVA Kirloskar DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Megnetic pickup Sensor suitable for 250 KVA Kirloskar DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Oil Pressure Sensor suitable for 250 KVA Kirloskar DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Coolant Tempetarure Sensor suitable for 250 KVA Kirloskar DG Set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Automatic Voltage Regulator suitable for 62.5-200 KVA Cummins/Kirloskar/M&Mahindra /Greaves DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Megnetic pickup Sensor suitable for 62.50-200 KVA Cummins/Kirloskar/M&Mahindra /Greaves DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Oil Pressure Sensor suitable for 62.5-200 KVA Cummins/Kirloskar/M&Mahindra /Greaves Cummins DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing against repairs Coolant Tempetarure Sensor suitable for 62.50-200 KVA Cummins/Kirloskar/M&Mahindra /Greaves DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing in replacement of electronic Governor with adjustment options for spped/voltage /field exicatation output module for 30-125 KVA Cummins/ Kirloskar/ Greaves/ M&Mahindra DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing in replacement of electronic Governor with adjustment options for spped/voltage /field exicatation output module for 160-200 KVA Cummins/ Kirloskar/ Greaves/ M&Mahindra DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for supply and fixing in replacement of electronic Governor with adjustment options for spped/voltage /field exicatation output module for 250 KVA Kirloskar DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
Material and labour in Repair for complete checking the controller of DG set from 250- 30 KVA ,3 phase 440 volts Make : Cummins/ Kirloskar/ Greaves/ M&Mahindra along with wiring and checking and rectifing the defects confirmation if required rectifing the set complete with checking of all sensors and protection including programming of the Controller and making the DG set operational for switching ON and Off through controller with safety features complete all as specified and directed.
Supply and fix against repairs automatic battery charger heavy duty 240 V input , 12 V / 5- 10 Amps output with auto cut off and floating complete all as spcified and directed by Engineer-in-charge
Removal of rusted MS sheet at any portion of canopy and supply and fixing new sheet of 14 gauge with fitting/ welding and painting complete as erquired.
Material and Labour for complete fixing in repairs for DG set Echostic enclosure door Hinges /Aldrops/ locks with keys -02 sets including carring out necessary repirs/modifications complete all as specified and directed
Repair of door by removing and replacement of demage hinges,acoustic material and providing / fixing of glass wool,tissu paper, MS perforated sheet with painting complete.
M & L for Earthing in Replacement complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m depth below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised earth strip of size 25x4mm by mean of bolt, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 3 of SSR Part - I, connected earthing test point and testing on complete all as specified and directed
Supply & fiXing in replacement of earth continuity conductor GI strip 25x4 mm.
Taking out and replacement of unservicable/blocked/rusted MS pi[pe heavey duty 3” dia.(NB) duly ISI marked , includung thermal insulation with 50 mm thick glass wool of 48 kg .per cubic meter denisity , chiken wire mesh and cladding with 24 gauge aluminium sheet for exhaust of smoke of DG set including fixing the cladded pipe on MS support structure on the wall / celling including cutting ,welding etc complete all as directed.
Supply and fixing Steel work in tubular trusses including special shaped washer etc,complete using ERW or induction butt welded tubes ,including one coat of zinck chromate primer paint including prepration of surface at contractor's workshopbefore fabrication complete allas specified and directed.
Material and labour for galvanised sheet 0.50 mm thick power pre coated in roof fixed with 'L' type or 'J' type or cranked hooked bolt complete all as specified and directed
Material & laboure for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply and fixing in replacement of water pump complete of existing make suitable for DG set 30 KVA to 250 KVA all as specified and directed.
Labour for attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc . Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in three hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
Material & labour for opening / taking down radiator of DG set of any type / make and capacity 30 KVA to 500 KVA from base mounting, cleaning / descaling using air compressor and cleaning with detergent etc and examining of water leakage of the same after cleaning , descaling and repairing of leakage, if any, using welding/brazing etc including replacement of all connecting parts i.e. radiator hose pipe with clamp, bolt, nut, washer, rubber bush, packing material etc and re-assembling the radiator, fitting with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed. Note : 1. The cost of replaced spares / parts is deemed to be included in quoted rates . 2. The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect.
Fixing only against Sch 'B' Free for Fixing gnerator Batteries.
BTY 12 V 100 AH
BTY 12 V 150 AH
BTY 12 V 180 AH
Removal of the defective change over switch of the DG sets and Supply fixing in repairs Manual onload change over switch with auxilary contacts operatable at 220V, 50Hz supply with enlosure operatable handle, 4 pole 200 A make L&T cat No.CO21600OSOO or equivalent SoComec/Schnider
Removal of the defective change over switch of the DG sets and Supply fixing in repairs Manual onload change over switch with auxilary contacts operatable at 220V, 50Hz supply with enlosure operatable handle, 4 pole 320 A make L&T cat No.CO11000OSOO or equivalent SoComec/Schnider
M & L for complete removal of unserviceble worn out Worn/ Spun grears,spindle lock adjustment of check plate,flag gat,servicing to safety brake unit, aligement of curtain,removal & dents and bends of bottom rail,adjustment to the spring load for the easy lift of the shutter by fexing of the locking colar & shaft colar to correct position and appling complliteone coat of synthetic enamal paint all over the metal surface of the shutter and refixing the same location complete all as specified and directed. NOTE:- Spare of shutter shall be measured and paid under relevant Item.
Supply only Spun Gear
Supply only Spindle Lock
Supply only Saft brake
Supply only Hood Cover
M & L for supply and fixing rotating rectifier diode set ( forward - 3 nos & reverse - 3 nos) along with surge arrestors suitable for the following DG set of make: CUMMINS/ M&Mahindra/Graves/ Kirloskar/Laysomer/ Perkins/Jyothi/stamford/crompton fixing and connecting in the circuit, starting and testing on load all as specified and directed by Engineer-in-charge
For Alternator of Capacity 250 KVA to160 KVA
For Alternator of Capacity 125 KVA to 30 KVA
Material and labour for complete servicing Auto Mains failure system for operation , control and protection of DG set by complete servcing/ carring out repairs of the power contctors/ACB'S , control contactors, timer units, SMPS units, rectifier units, PLA relays including replacement of worn out controll wiring , fuses and testing out out for complete operation of the dg set and AMF system. Note: Spares shall be paid under relevent item
Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs Make:L&T/GE /Seimens
Automatic Float cum Boost Charger 12V/10-15A with protection Fuse and LED indications Make:recomended by the OEM
Automatic Float cum Boost Charger 24V/15-25A with protection Fuse and LED indications Make:recomended by the OEM
Auxilary control Contactors /relays with Add On's Make: L&T/Schnider/ABB/Indoasian/PLA
Supply only of the following power contactors Coils operatable at 110V/230V/440V 50Hz Supply Make:L&T Model MNX / MCX of rated capacity /Schnider
Power Contactor Coil For 250 KVA Alternator AMF
Power Contactor Coil For 200-100 KVA Alternator AMF
Power Contactor Coil For 62.5 -30 KVA Alternator AMF
Supply only Control relay contactors of MXO type operatable at AC/DC supplies with NO/NC add ON as per the existing Site requirement complete all as specified and directed.
Material and labour for complete replacement of The Valve, shunt off item cat No 3017993 for Cummins Make engine of 250 dg sets.
Note (i)Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge In case of failure the penalty of Rs 1000 per day will be recovered from the contract.
M/s Adhikari construction co.
MV Engineers And Contractors
Buddham Builders
mayur enterprises
M/s Saravat and Company
Vijay Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .