Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹7.9 L Quoted ₹8.0 L | L1 | Accepted-AOC LOWEST TENDERER. |
| 2 | L2₹13.1 LRejected-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | ₹13.1 L | L2 | Rejected-AOC NOT LOWEST TENDERER. |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L2 | Shri Sai Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater, fixing new fpc panel of size 2 mtr X 1 mtr including necessary electrical/water connection complete all as specified asnd as directed.
Note: The items will be measured & paid for seperately as supply only | 7 | JOB | 1,000 ₹7,000 | 1,500 ₹10,500 |
| 2.00 | Supply only New FPC Panels. | 7 | EACH | 25,650 ₹1.8 L | 20,000 ₹1.4 L |
| 3.00 | Taking down Damaged panel & Supply new ,fixing ,testing & commissioning of toughen UV glass (1Mtr x 2Mtr) and as per existing size of glass for collector complete all as specified and directed | 9 | EACH | 22,530 ₹2.0 L | 8,000 ₹72,000 |
| 4.00 | Taking down U/S Hot water tank capacity 500 lpd & Supply and install ,Testing and commissioning of solar Hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, all as specified and as diected. Note Thickness tank should be existing size as per site
Make : V-guard/Farmson/Solar Hitech | 2 | EACH | 66,994 ₹1.3 L | 35,000 ₹70,000 |
| 5.00 | Taking down U/S Hot water tank capacity 300 lpd & Supply and install , Testing and commissioning of solar Hot water tank 300 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, all as specified and as diected. Note Thickness tank should be existing size as per site
Make : V-guard/Farmson/Solar Hitech | 2 | EACH | 53,134 ₹1.1 L | 25,000 ₹50,000 |
| 6.00 | Takiing down U/S steeel stand & and Material and Labour for steel stand for holding the panels / storage tank of capacity 500 LPD/300LPD /200 LPD solar water heater as required complete | 2 | EACHJOB | 2,500 ₹5,000 | 1,500 ₹3,000 |
| 7.00 | Taking out blockage GI pipe 20mm bore and cleaning the pipe including fitting , complete all as specified and as directed. (Note: Removing pipe checking for any blockage & Refixing the same after cleaning including necessary fittings required at site.) | 50 | RUNNING METRE | 100 ₹5,000 | 50 ₹2,500 |
| 8.00 | All as per serial item No. 7 above but of size 25mm bore | 55 | RUNNING METRE | 100 ₹5,500 | 70 ₹3,850 |
| 9.00 | Taking down U/S pipe & Supply and fix K-Tech pipe pf 15 mm bore dia for hot water including all fittings | 25 | RUNNING METRE | 350 ₹8,750 | 300 ₹7,500 |
| 10.00 | All as per item No 9 above but 20 mm bore dia | 40 | RUNNING METRE | 250 ₹10,000 | 350 ₹14,000 |
Updated dates
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Feb 2026, 6:00 pmClosed
LT COL RAVI KUMAR PATIYAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE OF SOLAR WATER HEATERS AND WATER PURIFIERS AT VAYUSENA NAGAR, NAGPUR
2026_MES_749936_1
8800/E8
Open Tender
Civil Works
240 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹20,000
26 Mar 2026
24 Jan 2026
28 Feb 2026
24 Jan 2026
26 Feb 2026
7 Feb 2026
Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater, fixing new fpc panel of size 2 mtr X 1 mtr including necessary electrical/water connection complete all as specified asnd as directed. Note: The items will be measured & paid for seperately as supply only
Supply only New FPC Panels.
Taking down Damaged panel & Supply new ,fixing ,testing & commissioning of toughen UV glass (1Mtr x 2Mtr) and as per existing size of glass for collector complete all as specified and directed
Taking down U/S Hot water tank capacity 500 lpd & Supply and install ,Testing and commissioning of solar Hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, all as specified and as diected. Note Thickness tank should be existing size as per site Make : V-guard/Farmson/Solar Hitech
Taking down U/S Hot water tank capacity 300 lpd & Supply and install , Testing and commissioning of solar Hot water tank 300 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, all as specified and as diected. Note Thickness tank should be existing size as per site Make : V-guard/Farmson/Solar Hitech
Takiing down U/S steeel stand & and Material and Labour for steel stand for holding the panels / storage tank of capacity 500 LPD/300LPD /200 LPD solar water heater as required complete
Taking out blockage GI pipe 20mm bore and cleaning the pipe including fitting , complete all as specified and as directed. (Note: Removing pipe checking for any blockage & Refixing the same after cleaning including necessary fittings required at site.)
All as per serial item No. 7 above but of size 25mm bore
Taking down U/S pipe & Supply and fix K-Tech pipe pf 15 mm bore dia for hot water including all fittings
All as per item No 9 above but 20 mm bore dia
Taking down U/S & Supply fixing , testing & commissioning of insulation for hot/cold water pipe 20/25 mm bore pipe complete all as speecified and directed.
Material and labour for descaling of heat exchanger inside of hot water tank of capacity 500LPD, including testing complete all as specified and directed.
Material and labour for gas welding of leaking joint in the flat panel collector and solar tanks complete all as specified and directed.
Supply and fixing Gun Metal gate valve for 20mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed.
All as per item No 16 above but 25mm bore pipe
Taking down U/S Supply and fix brass metal NRV ISI mark of size 20 dia complete with nuts,bolts,rubber gaskets etc including ,testing all as specified.
Taking down U/s and Supply and fix bib tap fancy type , cast copper alloy chromium coated , screwed down , screwed for iron pipe or for brass ferrule and fixed size 15 mm bore dia of pipe complete all as directed
Material and labour for PCC 1:3:6 with 20 mm aggregate for making foundation for placing of rotational moulded polyethylene water storage tanks of capacity 500 Ltrs all as specified and as directed.
Taking out of defective evacuated Glass tube from tube collector panel based on direct transforming heat of capacity 200 lpd and supply and install new evacuated Glass tube in to the direct transfer heat solar panel all as directed.
Taking down U/S Supply and fix solar hot water hose pipe 1" (25.4) mm dia ( 2 Mtr Each)conforming to IS (444) type 2 (WP) suitable for water pressure 3kg/cm2 including suitable size of clamps all as specified and as directed.
Material & Labour for removing damaged flat plate collector for repair from solar water heater after dismantling monkey guard,carryout necessary repair ,refixing the same and giving the monkey guard in original position after repair if any complete all as specified and directed.
Repair/Replacement of Heating element of capacity 3 KW, 230 V supply, with thermostat suitable for glass tube collector type solar water heater. Make : V-guard/Farmson/Solar Hitech
Material and labour Sub main wiring single phase using 2 Run of size 2.5 sqmm and 1 Run of PVC insulated PVC insulated and unsheathed multistranded FRLS copper conductor cable as earth wire using approved colour code as per IS drawing in and incl PVC Conduit medium grade with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed by Engr-in-charge of the following sizes of cables. Make Of cables: Havells/Finolex/Polycab PVC Conduit :Finolex/Polycab/Stardard. Note :- 2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including PVC Conduit heavy duty shall be measured as one unit
Material and labour for fabrication of staging for fixing of tank on roof for solar water heater , fabricated with mild steel angle, flat,etc including nuts, bolts, washers, welding, drilling holes for bolts, painting over all two coat synthetic enamel paint over one coat of primer, and taking down / dismantling of old staging complete all as specified & directed.
Comprehensive Maintenance for water purifier of any make / model including replacement of defective spare parts all as directed by the Enginer-in-charge and making the units functional as per requirement and emergency mainenance. Note: Spare parts will be measured and paid separately
Supply only PCB suitable for any make/model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Filter multilayer candle suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Sedimentiation Filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply and fixing PP 10 inch RO filter plant suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed.Make:- Aquaguard/Kent/Livpure
Supply only Carbon Filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Low/High Pressure Switch (LPC/HPC) suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only UV Choke suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Float valve sensor suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only UV barral suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only UF membrain suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Copper filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Alkaline filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only UF filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only NRV filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Far Infrared filter suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Elbow suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Taflon tape suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only PVC pipe 3/8 suitable for any make /model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Solonoid valve (SV) suitable for any make / model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Ultra violet lamp (UV) suitable for any make / model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only nozzle and nipple with connector suitable for any make / model of water purifier. Make:- Aquaguard/Kent/Livpure
Supply only Inlet /Outlet pipe 15 mm suitable for any make model of water purifier of existing system all as directed by Engr -in-charge Make:- Aquaguard/Kent/Livpure
Supply Only filter bowl including clamps suitable for any make / model of water purifier existing system all as directed by Engr -in-charge. Make:- Aquaguard/Kent/Livpure
Supply and fixing Booster pump including taking down old unserviceable booster pump all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixing transformer suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixing Member RO filter suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixing Member 40 x 40 RO filter plant suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixingof carbon 20 x 20 RO filter plant suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixing PP 20 x 2 RO filter plant suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Supply and fixing Control Panel for RO plant suitable for aquaguard alongwith taking down old unserviceable transformer all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Material and labour for painting RO plant skid and vassle for complete same colour as per site in officer mess and SNCOs Mess all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Material and labour for Pump set repair and servicing (High pressure pump and low pressure pump) RO plant officer mess and SNCOs Mess all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Material and labour for raw water Pump set repair and servicing RO plant officer mess and SNCOs Mess all as specified and as directed. Make:- Aquaguard/Kent/Livpure
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_839885.xls
BOQ • 0.46 MB
TD88800.pdf
Tender Documents • 0.36 MB
CRIEDIT8800.pdf
Tender Documents • 0.07 MB
Download all tender documents and submit your bid