| 3 | L3₹33.9 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹33.9 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹37.7 CrRejected-Finance C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹37.7 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹39.0 CrRejected-Finance | ₹39.0 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
₹27.8 Cr
EMD Value
₹15 L
Closing Date
20 May 2025, 6:00 pmClosed
CE Delhi Zone
HQ CE Delhi Zone Delhi Cantt
PROVN OF CENTRE FOR ADVANCED SCIENCES OF JOINT DISEASES, PEDIATRIC AND SPORTS MEDICINE, PHYSICAL MEDICINE AND MAJ REHABILITATION FOR ARMED FORCES MEDICAL SERVICES AT ARMY HOSP (RR), DELHI CANTT-10
2024_MES_684461_2
CEDZ/TOKEN-08 OF 2024
Open Tender
Civil Works
545 days
Delhi Cantt
As per Tender documents
10 documents required · 10 mandatory
₹3,000
GE E/M (RR) Hospital
₹15 L
Yes
19 Jul 2025
20 Mar 2025
22 May 2025
20 Mar 2025
20 May 2025
13 May 2025
Amount
Lump sum price worked out by the contractor for Schedule 'A' Section-I (Bldg Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-II (Site Clearance) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-III (Exacavation and Earth Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IV (Internal Electric supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-V (Internal Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VI (Fire Alarm) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VII (Lighting Protection) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (External Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IX (External Electric Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-X (Boundary Wall and Gate) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XI (Sewage Disposal) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XII (Area Drainage) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIII (Road / Footpath) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIV (Hot Water Supply- Geyser) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XV (Hot Water Supply- Solar) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XVI (Summer Appliences) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XVII (Lift) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIV (Fire Fighting System) (Ref pre priced Schedule attached seperately)
Description of Work / Item(s)
Amount
INTERNAL ELECTRIC SUPPLY
S & F Blanking plates for modular cover plate, complete all as specified and directed.
S&F in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base including fixing accessories, complete all as specified and directed.
S&F Ceiling recessed mounting LED SKY Lights luminaire, printed customized design (design as approved by GE) of size 600 mm x 600 mm, (2' x2'), 36 Watts, luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting. The LEDs used should have a color consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 120 lumen / watt, PF ≥0.95, Surge Protection 3.5KV. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires, complete all as specified and directed
Supply and fix modular Telephone socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc as required on site, complete all as specified and directed
Supply and fix modular RJ 45 Internet socket outlet for Cat 6 on the existing modular plate & switch box including connections but excluding modular plate etc as required on site, complete all as specified and directed
Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc, complete all as specified and directed
Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc., complete all as specified and directed
Design, manufacture, supply , installation, inspection, handling, assembling, affecting proper connections, testing and commissioning of Main L.T. Panel, Indoor type, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP54/42 with the following Specifications :- (a) 1250 A, 4P, 50 kA, EDO, ACB - 01 (Incomer, Tfr-01) (b) 1250 A, 4P, 50 kA, EDO, ACB - 01 (Incomer, Tfr-02) (c) 1600 A, 4P, 50 kA, EDO, ACB - 01 (Incomer, DG) (d) 1250 A, 4P, 50 kA, EDO, ACB - 01 (Bus Coupler) (e) 800 A, 3P, 50 kA, EDO, ACB - 01 (O/G) (f) 630 A, 4P, 55 kA, TMD, MCCB - 02 (O/G) (g) 400 A, 4P, 36 kA, TMD, MCCB - 03 (O/G) (h) 250 A, 4P, 36 kA, TMD, MCCB - 01 (O/G) (i) 200 A, 4P, 36 kA, TMD, MCCB - 02 (O/G) (j) 160 A, 4P, 36 kA, TMD, MCCB - 02 (O/G) (k) 100 A, 4P, 25 kA, TMD, MCCB - 03 (O/G) (l) 63 A, 4P, 25 kA, TMD, MCCB - 03 (O/G) (m) 63 A, DP, 10 kA, MCB - 03 (O/G) (n) Fan & Filter - 04 Each Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'C' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, ACB , rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
Supplying, installation, testing and commissioning of Capacitor Panel, floor mounting, dust & vermin proof, complete all as per specifications and accessories mentioned at Technical Specifications :- (a) 630 A, TPN, 36 kA, TMD, MCCB - 01 (b) Capacitor Bank, 50 KVAR - 04 Each (c) Capacitor Bank, 25 KVAR - 03 Each (d) Fan & Filter - 04 Each Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'D' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
Supplying, installation, testing and commissioning of LT Panel, indoor type (for Lift), floor mounting, dust & vermin proof, complete all as per specifications and accessories mentioned at Technical Specifications :- (a) 200 A, 4P, 36 kA, TMD, MCCB - 01 (I/C) (b) 63 A, 4P, 25 kA, TMD, MCCB - 06 (O/G) Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'E' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
Supplying, installation, testing and commissioning of LT Panel, indoor type (for light load), floor mounting, dust & vermin proof, complete all as per specifications and accessories mentioned at Technical Specifications :- (a) 100 A, 4P, 25 kA, TMD, MCCB - 01 (I/C) (b) 63 A, 4P, 25 kA, TMD, MCCB - 01 (O/G) (c) 40 A, 4P, 25 kA, TMD, MCCB - 05 (O/G) Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex "F' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
Supplying, installation, testing and commissioning of LT Panel, indoor type (for UPS load), floor mounting, dust & vermin proof, complete all as per specifications and accessories mentioned at Technical Specifications :- (a) 100 A, 4P, 25 kA, TMD, MCCB - 02 (I/C) (b) 100 A, 4P, ATS Switch - 01 (c) 63 A, 4P, 25 kA, TMD, MCCB - 02 (O/G) (d) 40 A, 4P, 25 kA, TMD, MCCB - 05 (O/G) Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'G' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel
Supplying, installation, testing and commissioning of of LT Panel, indoor type (for Power load), floor mounting, dust & vermin proof, complete all as per specifications and accessories mentioned at Technical Specifications :- (a) 200 A, 4P, 36 kA, TMD, MCCB - 01 (I/C) (b) 63 A, 4P, 25 kA, TMD, MCCB - 05 (O/G) (c) 40 A, 4P, 25 kA, TMD, MCCB - 02 (O/G) Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'H' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 1600 Amps, 50 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 800 Amps, 50 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc., complete all as specified and directed. as required. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 400 Amps, 35 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required., complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 1600 Amps, 50 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 800 Amps, 50 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 400 Amps, 30 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking / rising mains, testing and commissioning of 200 Amps, 15 kA SC for 1 Sec, capacity Plug In / Tap Off Box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB (but without MCCB) complete etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking / rising mains, testing and commissioning of 125 Amps, 15 kA SC for 1 Sec, capacity Plug In / Tap Off Box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB (but without MCCB) complete etc. as required, complete all as specified and directed. Make : LK/ Legrand/ Schneider/ ABB /C&S
Supply and laying XLPE Cable, 35 Sqmm, 4 core, insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded Copper conductor, complete all as specified and directed
Supply and laying XLPE Cable, 16 Sqmm, 4 core, insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded Copper conductor complete all as specified and directed
Supply and laying XLPE Cable, 10 Sqmm, 4 core, insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded Copper conductor, complete all as specified and directed
Supply and laying XLPE Cable, 2.5 Sqmm, 2 core, insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded Copper conductor, complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 4 X 10 sq. mm (25mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 4 X 16 sq. mm (28mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 4 X 25 sq. mm (28mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 3½ X 35 sq. mm (32mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 3½ X 50 sq. mm (35mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 3½ X 70 sq. mm (38mm), complete all as specified and directed.
Supplying, fixing and making end termination with brass compression gland and aluminium lugs of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade, for 3½ X 300 sq. mm (70mm), complete all as specified and directed.
Supplying and laying of DWC HDPE pipe, 63 mm dia (OD-63mm & ID-51mm nominal), ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete all as specified and directed.
Supplying and laying of DWC HDPE pipe, 90 mm dia (OD-90mm & ID-76mm nominal), ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete all as specified and directed.
Supplying and laying of DWC HDPE pipe, 120 mm dia (OD-120mm & ID-103mm nominal), ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete all as specified and directed.
S & F cable junction box 200 x 160 x 98mm in size made out of thermoplastic sheet having IP 65 protection for out door installation fixed with 4 way bakelite cable terminals with one MCB SP 6 Amps to be fixed inside the box including 03 Each polynide gland with check nut (M-32 - 3 Each) fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer for iron clamps, complete all as specified and as directed.
Supply errection and testing of post top Modem 40 watt decorative spun aluminium housing with power LED,s and extruded aluminium heat sinks. A UV stbilized PC/PMMA diffuser is provided for glare free lighting with high visual comfort. Available in 3000k/6000k, complete all as specified and as directed.
Supply and errection of 4.00M Decorative pole with cast iron embellishment at bottem & middie with designer cast aluminum ribbed design double arm bracket. Pole is made of mild steel & galvanized complete with service window containing 6-amp MCB ,4- Way connector, complete all as specified and as directed.
Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor, complete all as specified and as directed. Note :Excavation & earth work shall be measured separately.
INTERNAL WATER SUPPLY
Supply & laying 65 mm dia GI Tubes, 'medium grade', random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed.
Supply & fixing 80 mm dia GI Gate valves (brass insert) as per requirement of the site, complete all as specified and directed.
Supply & fixing 65 mm dia GI Gate valves (brass insert) as per requirement of the site, complete all as specified and directed.
Supply & fixing Over head shower 200 MM DIA/square single flow ( ABS body chrome plated with grey face plate) with rubit cleaning system and flow restrictor 6.0 LPM at 3 bar pressure and with CP Shower arm 250 mm long , fancy type with wall flange, complete all as specified and directed.
Supply & fixing health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making conection and fixed in position, complete all as specified and directed.
Supply & fixing towel rail 600 mm long CP brass fixed with and including cromium plated brass screws and wooden/ plastic cleats, complete all as specified and directed.
S&F Liquid soap dish of CP brass fancy type fixed with, including cromium plated brass screws and wooden/ plastic cleats, complete all as specified and directed.
S&F Towel ring OF CP brass fixed with and including Chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
S&F glass corner shelf assembly cosisting of 5.5 thick sheet glass, shelf 30x30 CM corner with chromium plated bracket guard and railing necessary CP fiting, complete all as specified and directed.
Supply & fixing Urinal spreader of CP brass with and including cromium plated brass screws and wooden/ plastic cleats, complete all as specified and directed.
Supply & fixing luxury Towel Rack of size 600x450mm CP brass with and including cromium plated brass screws and wooden/ plastic cleats, complete all as specified and directed.
Supply & fixing luxury WHB Mixer of CP brass including all fitings, complete all as specified and directed.
PATIENT CALL SYSTEM
Supplying, installation, testing and commissioning of QMS as specified below complete with racks, patch panel, active components, cabling outlet, back boxes, cable pilling etc, complete all as specified for the following specifications :-
(a) Token display 4 Inch 3 digit - COUNTER DISPLAY Used to call a registered Token No - Display - Bright 7 Segment Digit Size - 2 Inches, No of Digits - Total 4 (3 Digits red color for token and 1 Digit green for counter), Interface - Wired Rs485 or Wireless 865 Mhz RF. Power Supply - 12V DC
(b) Token calling unit - Used to announce called token no in human voice in two predefined languages English and Hindi. Interface - Wired Rs485 or Wireless 865 MHz RF. Power Supply - 12V DC
(c) Media converter - MEDIA CONVERTER. All counters shown on LED tv screen with current token no. Connectivity :- 1x full size HDMI , 4x USB 2.0 , LAN Screen Size LED SMART TV 24"inch - 65"inch. Wireless RF /Rs485 connection interface. Input voltage - 230 AC, 50Hz
(d) Cat 6 wire
(e) RJ45 outlets in existing backbox
(f) Supply & laying of 20mm PVC Conduit
(g) Supply and installation of GI backbox for RJ45 outlets
(h) 2 Module Back Box
(j) Token Dispenser unit 58 mm paper width with direct thermal printing method type. Interface RS232-C and print speed of 50mm/sec and mechanical lifetime of minimum 50km. Sheet metal with Vinyl enclosure of approx size 77X77X44mm with LCD display of alphanumeric 16 characteristic, 2 lines with backlight with wireless 865 MHZ RF and 230V AC, 50 Hz
FIRE ALARM SYSTEM
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector with base as required, complete all as specified and directed.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required, complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM complete all as specified and directed, complete all as specified and directed.
Supplying, installation, testing & commissioning of addressable fire control module complete as required, complete all as specified and directed.
Supplying, installation, testing & commissioning of fault isolator, complete with base as required, complete all as specified and directed.
Supply, installing, testing and commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved, complete all as specified and directed
Supply, installation, connecting, testing and commissioning of Addressable Hooters cum strobe min. 80 db output and 110 candelas complete with modules. The strobes shall be synchronised for better evacuation, complete all as specified and directed.
Supplying, installation, testing & commissioning of fire fighter phone jack, complete as specified and directed.
Supplying, installation, testing & commissioning of fire fighter telephone handset, complete as specified and directed
Supplying & laying of 2 x 1.5 sqmm fire survival armoured cable, 600 / 1000 V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath, complete all as specified and directed.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker, complete all as specified, directed and as required. Makes : Actis / Honeywell / Bosch
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with integration facility with main fire alarm panel for voice evacuation, complete all as specified, directed and as required. Makes : Actis / Honeywell / Bosch
Supply, Installation, Testing & Commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection, complete all as specified and directed. Makes : Actis / Honeywell / Bosch
Supplying and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable, complete all as specified and directed. Makes : Polycab/ RR Kabel/ Paramount/ Parasheild/ Derwiser
TELEPHONE INTERCOM & TV CONDUIT
Supply, installation, testing & commissioning of Pure IP at core server Based voice solution with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,47 IP users License ,01 Each IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode, complete all as specified and directed. Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix/Nexxus
Supply, installation, testing & commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE, complete all as specified and directed. Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix/Nexxus
Supply, Installation, Testing & Commissioning of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh, complete all as specified and directed. Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix/Nexxus
Supply & Fixing Rigid non-metallic PVC conduit 25 mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
Supply and fixing of Modular White cover plate with frame, 2 module, complete all as specified and directed
Supply and fixing of Modular metal flush box 1/2 module, complete all as specified and directed
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required for Telephone Socket outlet, complete all as specified and directed.
DG SET
Supply, installation, testing and commissioning of 2 x 500 KVA SILENT D.G. SET WITH INBUILT SYNC PANEL AND LOAD MANAGER 415 Volts, 3 phase, along with AMF cum Synchronization Panel in-built and integrated inside canopy, PRIME Rated DG set rated at 1500 RPM, Radiator Cooled with associated accessories, having 10% overload capacity for 1 Hour in every 12 Hrs of operation as per relevant ISO & latest CPCB Norms. DG set along with Acoustic enclosure shall be provided and mounted on the common base frame and Genset shall be suitable to transport from one place to another without dismantling the Acoustic Enclosures. Genset shall be provided with inbuilt Fuel tank, mounted at the base frame of the Genset and all the specifications have been mentioned at Annexure 'A'. Notes: (a) Annexure 'A' has been uploaded along with the tender documents and is the part of BOQ for all purposes. (b) The DG Set and all accessories / fittings shall conforming to relevant IS with latest amendments. (c) Completion of the work shall be issued after precommisioning of DG Set inspection by Testing Officer. Necessary diesel, tools and equipment shall be provided by the contractor for testing / precommsioning without any extra cost.
NURSE CALL SYSTEM
Supply, installation, testing & commissioning of Main Display with 3 x 3 FND (3 digits X 3 displays), 20 call memory - Calls are stored from the 1st place (top left) - 2nd place (top right) - 3rd place (bottom right) . from the 4th calls are hidden in order (till 47 calls). If the cancel button is pressed from Call Point, the responding call is deleted regardless of the order of the call . If Cancel Only button is pressed, the 1st call is deleted, then the 2nd call display takes the place of the 1st call, the 3rd call display takes the place of the 2nd call and the hidden 4th call takes the place of the 3rd call. Make - Solt Memory :last 20 calls ,22 different sound, 7 Segment Alphanumaric Display, power Adaptor With 12 V/1.5 Amp DC power, complete all as specified and directed.
Supply, installation, testing & commissioning of software for PC Monitoring to display active calls on the computer screen and play different sound based on call type, different background colours for different call types complete with one PC with Windows 11 with speaker and working USB, complete all as specified and directed.
Supply, installation, testing & commissioning of Call-cancel - 6 buttons (5 call / 1 cancel or 3 call/3 cancel)..BK-black, Whwhite .transmit a radio signal for a distance of up to Indor up to 30 to 50 meters & open site 100 meters . They can work Lithium Coin Battery ( 3 V) up to 18 month without changing the batteries, complete all as specified and directed.
Supply, installation, testing & commissioning of cabled push-button 2X : call/cancel, 3X : 3 call/cancel With come spiral Cable & Push Button for tension free use .with required cable length as needs, complete all as specified and directed.
Supply, installation, testing & commissioning of Repeater - Transceiver (Receiver & Transmitter) max. output 10mW . Extending the signal range .Easy configuration .Avoid duplication of the same calls .Register up to 999 call buttons. Unit power Adaptor With 12 V/1.5 Amp DC power complete all as specified and directed
Supply, installation, testing & commissioning of Call / Cancel button (Transmitter) with pull-string(1 m) for Toilet Unit, complete all as specified and directed.
Supply, installation, testing & commissioning of Mounting cover for fixing SB6 series call points to the wall, complete all as specified and directed.
HAND DRIPER & SOAP DISPENSER
Supply and fixing stainless steel fully automatic "No Touch infra red activation" hand drier suitable to operate on 220 volts, single phase 50 hz., A.C. power supply, motor 550W, speed 25000 rpm dry time 20 sec, auto cut off 60 sec, complete all as specified and directed.
Supply and fixing stainless steel fully automatic "No Touch infra red activation" soap dispenser suitable to operate on 220 volts, single phase 50 hz., A.C. power supply, time 20 sec, auto cut off, complete all as specified and directed.
SIGN BOARD
Supply and fixing of hospital sign boards of different types and size i.e. illuminated and others for depiction of various wards, deptts, centres, services and other locations in the hospital including day and night signs and patient guidance system, complete all as specified and directed.
LIGHTENING PROTECTION
Supply, installation, testing and commissioning of Lightning Strike counter for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor, complete all as specified and directed. Make: ERICO, FURSE, OBO
Supply, installation, testing and commissioning of OBO make Encapsulated Class B+C surge arrester (V25-B+C) for three phase four wire system with nominal discharge current (In as per IEC 61643-1) 30KA (for 8/20ms) & Impulse current 7KA(for 10/350ms) per pole between phase to neutral. & 50KA (8/20ms) current for neutral to earth. Maximum continuous operating voltage should be 320V. Response time (ta) should be less than 25ns for phase to neutral. Voltage protection level should be less than 900V at 5KA (8/20ms) for phase to neutral & 1.2KV for neutral to earth, complete all as specified and directed.
Supply, installation, testing and commissioning of OBO make Encapsulated Class C surge arrester (V20-C) for three phase four wire system with nominal discharge current(In as per IEC 61643-1) 20KA (for 8/20ms) between phase to neutral & 50KA (for 8/20ms) between neutral to earth. Maximum continuous operating voltage is 320V. Response time (ta) should be less than 25ns for phase to neutral. Voltage protection level should less than 1.3KV at 5KA (8/20ms) for phase to neutral & 1.2KV for neutral to earth, complete all as specified and directed.
30KVA/30KW Online Modular UPS (In N+1 Mode): Supply, installation, testing and commissioning of min 30KVA/30KW or Higher rating True - On - Line, Energy Efficient, configuration double conversion UPS with DSP (Digital Signal Processor) / Microprocessor Based Control System using IGBT Based Technology and High Switching Frequency PWM (Pulse Width Modulation) with PFC controlled IGBT Rectifier with Active Power factor Correction (APFC). The Design of the UPS shall be Modular Type with Decentralized parallel Architecture. and the Power Module shall be upto 20KW Range to achieve high redundancy. UPS should be in N+1 mode for redundancy purpose so that at least one Module should be spare apart from 60KW capacity. In case of Overloading due to any reason the Total Load shall be transferable to Mains Source without affecting the working condition of equipment which are operational. Modular UPS with HOT Swappable Power Module upto 20Kw (No Module shall have different Rating it means all Modules shall be of same rating). The detailed specifications are mentioned at Annexure 'B'. Notes : (a) Annexure 'B' has been uploaded along with the tender documents and is the part of BOQ for all purposes. (b) The UPS and all accessories / fittings shall conforming to relevant IS with latest amendments.
SUMMER APPLIANCES
Supply, installation, testing and commisioning of refrigerator electric driven, single phase, direct cool capacity 215 Ltr ,BEE-5 star rating, complete all as specified and directed.
Supply, installation, commissioning of Water purifier having filtration capacity 50 LPH having purification storages RO+UV+UF+TDS technique, complete all as specified and directed. Make : Aquaguard, Kent, Livpure, Havells
(a) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim. (b) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size (c) Micro processor based VVVF type main controller with closed loop system. (d) Car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous. (e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other accessories. (f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being rescued. (g) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of beltwire rope and taking elevator nearest landing. (h) Provision of safety guarding equipments such as 02 Each pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches. (j) Door sensor not less than 74 beam, 2D infra red full length (k) Provision of fire man switch complete at ground floor fitted in box including SS face plate. (l) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown.
(m) Do's & Don’ts chart on stainless steel to be installed inside the car cabin. (n) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on. (o) Provn of 40 mm SS handrail on three side of the lift. (P) Provn of transparent space for highlights the imp instructions and mobile numbers. (q) Provn of RCCB/RCBO in SS enclosure.
Supply, installation, erection, testing and commissioning of lift electrically operated microprocessor controlled complete with power driven automatic stainless steel (SS) sliding doors and having SS car enclosure suitable to carry 20 passengers (1360 kg) at a speed of 0.5 m/sec to serve 4 floors (G+3) including automatic rescue device all as per description of item No. 107 above, complete all as specified and directed.
Supply and fixing 6 sqmm 4 core copper conductor PVC insulated sheathed cable, complete all as specifed and directed.
Supply and fixing sheet metal enclosure loadline DB VTPN, 4 way, double door in as incomer, IP-43 dust and vermin proof, vertical type suitable for MCCB as incomer duly fixed on wall on angle iron frame in and including following items complete all as specifed and directed:- (i) MCCB 100 Amps, TPN, 25KA, 50Hz, 415 volts with Thermal magnetic release- 01 Each (ii) RCBO, 40 Amps, 300mA, 4 pole-02 Each (iii) MCB, 25 Amps, 10 Ka, TPN-01 Each(Spare)
Supply, installation, erection, testing and commissioning of Dumbwaiter lift electrically operated microprocessor controlled complete with power driven automatic stainless steel (SS) sliding doors and having SS car enclosure ,suitable to carry 250 kg at a speed of 1.5 m/sec to serve 4 floors (G+3) including electrical panel with MCB 63 Amps, TPN, 25KA, 50Hz, 415 volts with Thermal magnetic release-01 Each,RCBO, 32 Amps, 300mA, 4 pole-01 Each,MCB, 16 Amps, SPN-01 Each for Lighting, complete all as specified & directed.
AIR CONDITIONING
Water Cooled Screw Chiller AC Plant Design, Supply, Installation, Testing and Commissioning of 260 TR (130 TR x 2 (Working) 1x 130 TR (standby) Water cooled screw type Single/ Multi Compressor, Single/ Multi Ref. Circuit water chilling machine with unit mounted factory fitted VFD each having a capacity as given hereunder at chilled water inlet/outlet temperature of 54°F / 44°F, condenser water inlet/outlet temperature of 87.8°F / 95.0°F, suitable for operation on factory charged refrigerant as per OEM recommendation. The Refrigerant shall be as per A1 safety classifiation only (Final approval of refrigerant will be done by GOI latest guidelines on HFC phase down in India as per kigli amendment) for screw type machine each, complete all as specified, directed and comprising of the followings :- Note : The compressor must be OEM manufacture only. Make:-Trane, York, Carrier Design Conditions :- -Wards/departments - 24±2°C and OTs- 18±2°C -Screw type compressor semi hermetic complete with automatic capacity control safety switches, forced feed lubrication system -The semi hermetic compressor should be twin type. Capacity control range of compressor shall be from 20% to 100% at constant condenser entering water temperature. -Suitable capacity squirrel cage induction motor with class 'B'/'H' insulation suitable for operation on 415 +- 10% volts 50Hz, A.C. supply.
(a) 1 No. suitable capacity unit mounted factory fitted Variable frequency drive for the above compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventers etc complete as required Necessary drive arrangement. (b) 1 set - Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. (c) 1 No. - Matching shell and tube water cooled condenser of M.S. shell and integrally finned copper tubes with Max Pressure Drop of 3-5 mtrs (d) 1 No. - matching shell & tube flooded type chiller for screw type units of MS shell and copper tubes with Max. Pressure Drop of 3-5 mtrs (e) 1 Lot - Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve. (f) 1 set - Microprocessor based control panel complete with accessories as per specifications. (g) Lot - Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc. (h) Lot - Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required. (j) Lot - Suction line and chiller factory insulated with minimum 19mm thick polyvinyl nitrile rubber insulation c (k) Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. omplete as required.
(v) PRIMARY CHILLED WATER PUMPS (2W + 1S) :- Design, Supply, testing and commissioning of Split Coupled Type Vertical In-Line Centrifugal pumping unit capable of delivering desired flow rate and head. The pumps shall be radially split, single stage centrifugal type with CI casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections, Bronze dynamically balanced impeller, stainless steel shaft, lower carbon throttle bushing, Outside Balanced type mechanical seal with Resin Bonded Carbon rotating face, Sintered Silicon Carbide stationary seat and Viton secondary seal. (i) The Vertical In-Line (VIL) pump single stage, single or double suction type, with pump characteristics which provide rising heads to shut off, shall be supplied with a IP 56 TEFC, 415/3/50 motor efficiency equivalent to IE2 motor, Vertical In-Line Pump working on Sensor- less technology. (ii) The VFD LCD should display the dynamic head & flow rate at any point of operation, As flow & head is directly available from pumps VFD. (iii) All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge or using sensorless alogorithms,( 1 flow meter and 2 pressure gauges to be supplied for each VFD driven pump). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head of each pump using sensorless alogorithms. (iv) Pump Casing - Cast Iron with PN16 flanges for working pressure to 12 bar at 65°C Suction and discharge connections shall be flanged and the same size and shall be drilled and tapped for seal flush and gauge connections (v) The pump is to be fitted with a factory installed flush line. The squirrel cage induction type motor, with TEFC enclosure and shall be connected to the pump through a high tensile aluminum, split type spacer coupling to permit Servicing of the mechanical seal without disturbing pump, motor or electrical wiring. Coupling shall be protected by a guard. (vi) Mechanical Seals - Shall be Stainless Steel multi-spring outside balanced type with Viton® secondary seal, carbon rotating face and silicon carbide stationary seat. Provide a 316 stainless steel gland plate. Provide factory installed flush line with manual vent to purge air prior to pump start-up. All split coupled pumps shall be provided with a lower seal chamber throttle bushing to ensure seals maintain positively cooling and lubrication. Seal flush line accessories, if required to improve seal chamber cleanliness
BLANK
(w) SECONDARY CHILLED WATER PUMPS (2W + 1S) for Hospital area and (2W + 1S) for OT area:- Design,supply, installation,testing and commissioning of PN16 split coupled pump capable of delivering desired flow rate and head. Pumps shall be split-coupled Vertical In-Line Pumps with rigid spacer type couplings. Pumps shall be supplied with high efficiency inverter duty motors. The secondary pumps shall be split-coupled Vertical In-Line Pump. Pumps shall be supplied with integral high efficiency inverter duty motors. The Pump submittals shall be complete with certified pump curves, pump performance characteristics with pump and system operating point plotted (i) The Vertical In-Line (VIL) pump single stage, single or double suction type, with pump characteristics which provide rising heads to shut off, shall be supplied with a IP 56 TEFC, 415/3/50 motor efficiency equivalent to IE2 motor, Vertical In-Line Pump The VFD LCD should display the dynamic head & flow rate at any point of operation, As flow & head is directly available from pumps VFD. (ii) All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge ( 1 flow meter and 2 pressure gauges to be supplied for each VFD driven pump). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head of each pump using sensorless alogorithms. (iii) Pump Construction: Pump Casing - Cast Iron with PN16 flanges for working pressure to 12 bar at 65°C, Suction and discharge connections shall be flanged and the same size and shall be drilled and tapped for seal flush and gauge connections. (iv) Impeller – Bronze/, fully enclosed type. Dynamically balanced. Two-plane balancing is required where installed impeller diameter is less than 6 times the impeller width. (v) Shaft - Provide Stainless Steel pump shaft. (vi) Coupling - Rigid spacer type of high tensile aluminium alloy. Coupling to be designed to be easily removed on site to reveal a space between the pump and motor shafts sufficient to remove all mechanical seal components for servicing and replacement without disturbing other components of the pump or motor. The coupling shall be provided with a fully enclosed guard complying with the Machinery Directive.
(vii) Mechanical Seals - Shall be Stainless Steel multi-spring outside balanced type with Viton® secondary seal, carbon rotating face and silicon carbide stationary seat. Provide a 316 stainless steel gland plate. Provide factory installed flush line with manual vent to purge air prior to pump start-up. All split coupled pumps shall be provided with a lower seal chamber throttle bushing to ensure seals maintain positively cooling and lubrication. Seal flush line accessories, if required to improve seal chamber cleanliness. Make:- Xylem ,Grundfoss, Armstrong (viii) BLANK
(x) CONDENSER WATER PUMPS:- Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump of suitable capacity (2W + 1S) each capable of delivering the specified flow rate comprising the following and complete as per specifications. (i) Casing (Volute) - Cast Iron. (ii) Impeller - 316 Stainless Steel - Statically and Dynamically Balanced (iii) Casing Gasket - Confined Non Asbestos Fiber (iv) Pump Shaft - SS 316. (v) Flush Line - Braided Stainless Steel (vi) Mechanical Seal - Outside Balanced (vii) Motor Type - Parmanent Magnet Motor , Efficiency Class - IE5 Pump Effi minmum 80% All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge or using sensorless algorithms,( 1 flow meter and 2 pressure gauges to be supplied for each VFD driven pump). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head of each pump using sensorless algorithms.VFD screen should be touch screen
BLANK
(y) COOLING TOWER (2W + 1S) :- Design, Supply , installation, testing and commissioning of Induced Draft counter flow Fibre glass-reinforced Cooling Towers of suitable size (2 cell) CTI Certified in accordance with the technical specification, Drawings and Schedule of Quantities. Tower shall be vertical , Induced Draft counter flow type in fibre-glass reinforcement plastic construction , complete with statically and dynamically balanced axial flow type fan, TEFC induction motor with efficiency class IE3, surface and spray section , eliminators , steel supports and its flow must be minimum 1.3 times of rated chilled water flow. The tower shall be CTI certified and meet energy efficiency per ECBC 2017 standards. The tower shall be complete in all respects inlcuding but not limited to base frame, mounting, Isolating devices, tanks, drift eleminator, make-up quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, steel/ masonary supporting structure, anti-vibration mountings etc and other accessories as mentioned in the specifications. The Unit shall be complete in all respect and shall be factory tested with reports submitted. The scope of work shall include Lifting, shifting & positioning of cooling tower at location with suitable size foundation. The dB levels shall be less than 80 dB(A) at 3 m distance. Make:- Delta, Paharpur,Mihir,POLO VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design. VFD shall be capable of operating in voltage ranges of 240V or 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The Cooling tower shall be capable to communicate effectively with BMS on open protocal modbus/Bacnet. WBT : at 83º F WB Approach : 2.80º C Maximum Hot water IN : 97.5 ºF Hot water OUT : 90ºF Drift loss < 0.005%
(aa) AIR HANDLING UNIT FOR OTs:- Design, Supply, Install,testing and commissioning of factory built weather Proof Floor mounted double skin type air handling units of suitable capacity AHRI/Eurovent Certified for 04 Nos. OT for min 20 no. air changes per hour with at least 4 of those air changes being fresh air, 50 mm thick double skin construction Floor Mounted Air Handling Units comprising of following parameter of - Casing Strength- D1, Thermal Bridiging Factor - TB2, Thermal Transmittance - T2, Casing Air Leakge - L1, Fillter By pass Factor- F9. Outer skin will be 0.8mm thick pre-coated GI & inner skin will be 0.8mm thick plain Aluminium. Each OT will have independent AHU system Make:- Zeco, Flaktgroup,Trane, Edgetech (i) LOWER TIER- WITH Min.20% FRESH AIR ARRANGEMENT INTAKE SECTION - Fresh Air intake section with GI louvers require to access the pre filter and EAC filter.Primary Filter Section - Pre filter section will be fixed along with EAC filters ( To maintain PM 2.5 level upto desired level) to work as a primary filteration.Coil Section- Coil section require with multi row deep chilled water, hot water & DX coil section. Sufficient space is require between both the coils for maintenance. Both coils will be on working condiiton togather. DX coil require with 3/8 inch IGT tube. Tube thickness must not be less than 0.5mm.UVGI require for both chilled water & DX coil with running hour meter. Hot water coil require after DX coil. Chilled water coil require AHRI certified only. (ii) EC fan Section -The Fans must required in (N+1) mode . The minimum efficiency class of the motor shall be equivalent to IE5. The motor shall be Permanent magnet external rotor motor with integrated electronics and suitable for continuous operation. The speed of the motor shall be varied with an external 0-10V/ PWM control signal. The fan in totality shall be of most efficient type so that the power Consumption and noise level is minimal. The motor shall be minimum IP54 protection class. Fan must be AMCA certified.Fine Fiter Section - EU-7 Rigid media type filter section require after fan section.Supply Air Damper require in AL construction.
(iii) Exhaust Air Damper Require in AL construction. Controller module with RS 485 port compatible with BMS, on board protocol following 1. Fan operation status 2. Chilled water valve operation status 3. AHU Airflow (CFM) 4. AHU power consumption Controller shall also have fire trip alarm compatibilty to shut AHU in case of signal from fire panel.
Instrumentation Kit to be provided to give out the following option 1. Supply air temperature / RH Sensor 2. Return air temperature / RH Sensor 3. Fresh air temperature Sensor 4. Chilled water in temperature Sensor 5. Chilled water out temperature Sensor 6. DP switch across filter for filter clog 7. Touch screen display-Min.7'' 8. DPT 9. UVGI status 10. CO2 Sensor The other than above following features/facilities are also required in AHU : 1) High efficiency air filtration for supply and extract air 2) Capable to control room air temperature and relative humidity throughout the year 3) Variable fresh air supply for OT/procedure room requirements. 4) Self-contained (controller) is an independent system, which is under the direct control of the authorised personnel where room temperature, relative humidity, room positive-negative pressurization levels etc. can be maintained. 5) Enabled to maintain positive or negative pressure per the requirement for the occupied area by providing independent supply air and exhaust air fans with inverter driven motor. 6) PLC unit (MICROPROCESSOR CONTROLLING SYSTEM) controls. 7) Enabling unit to work on positive pressure/negative pressure with the help of PLC as per the instructions of the Engineer-in-charge or as per the requirements supports Aseptic conditions in the operation theatre as well as in surroundings which is the foremost requirement for any medical operation. . System shall have provision to adjust the respective pressure (positive and negative Pressure) along with all required sensors etc. AHU's shall be provided with thermal brake profile and UV light & Pre-coated GI canopy (if required at site) and all dampers shall be of motorised type. Plenum to be designed for each OT having HEPA filter. Size of AHUs to be calculated considering pressure drop due to HEPA filter.
(ab) AIR SIDE WORKS/Site fabricated Duct-GI duct :- Design, Supply, installation, balancing and commissioning of Site fabricated GI sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of suitable sheet thickness or supply and return air ducts complete as required and shall also confirm to the BIS specifications. Plenum must be prepared with 20G GI sheet and any exposed duct with 22G GI sheet. (ac) S&F of thermal insulation on new ducts and plenum chamber, comprise of preparation of surface and fixing of new cross linked closed cell polythene, plane, fire retardant insulation of 25 mm thick nitrile insulation with aluminium foil of the duct and 30mm thick on exposed duct having K value of 0.027-0.029 Kcal/hr/m at 0-23°C with minimum density of 33 Kg/cum, fire retardant self extinguishing on dripping, good ozone resistance, including fixing the insulation to the duct surface with help of adhesive paste and closing the gap with self adhesive tape of 3mm thick, complete all as directed. Make - ARMFLEX / KFLEX /PARAMOUNT (ad) Factory Fabricated Duct - AL duct (Operation Theaters):- Design,Supply,Fabrication , Installation and testing of sheet metal ducts of suitable sheet thickness in accordance with the approved shop floor drawings and specifications , and shall also confirm to the BIS specifications. The hardware shall be chrome plated or of stainless steel.All lateral and transverse joints shall be sealed with silicon based mastic sealant.Plenum must be prepared with 20G GI sheet and any exposed duct with 22G GI sheet. (ae) Grilles/Diffusers ALUMINIUM :- Designing,Providing and fixing of Extruded aluminium supply and return air grilles/diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Supplying & fixing of powder coated extruded aluminium Supply Air Grills as per requirement (af) Dampers :- Each AHU must be provided with motorised fire dampers made up of 22G GI sheet with all electrical control cabling.
(ag) DUCT LINE ACOUSTIC TREATMENT:- Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications 15mm thick sound board for Floor Mounted AHU's 10mm thick sound board for Ceiling Suspended AHU's (ah) Hot Water Generator Designing,Supplying, Installing, Testing and Commissioning of multi step (min 3 no. steps) suitable capacity Horizontal Smoke Tube type factory supplied hot water generators each suitably rated for delivery including insulation as per manufacturer's standard and having following accessories. Location : Plant Room a. Built in electric panel, programmable timer, automatic MONOBLOC imported burner control, water pump assembly, oil filter, safety valve, strainers, valves, pressure / temp. gauges, pressure switches, flue gas sampling point. b. All other mounting, fittings and controls. c. Suitable for electric supply of 415 + 10% volts & 50 Hz. d.Thermometer at the outlet of each hot water generator. e. All interconnecting wiring / cabling between hot water generator and electric panel. f. The HWG shall have an in-built facility complete with temperature sensor to start / stop depending on variation in demand at different periods.
(aj) Hot water Pumps (2W + 1S) - OTHER HOSPITAL AREAS AND OPERATION THEATERS Design, Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. (i) Casing (Volute) - Ductile Iron. (ii) Impeller - 316 Stainless Steel - Statically and Dynamically Balanced (iii) Casing Gasket - Confined Non Asbestos Fiber (iv) Pump Shaft - SS 316. (v) Flush Line - Braided Stainless Steel (vi) Mechanical Seal - Outside Balanced (vii) Motor Type - Parmanent Magnet Motor , Efficiency Class - IE5,Pump Effi minmum 80% and rated capacity of 2.2 kW. (viii) All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge or using sensorless algorithms,( 1 flow meter and 2 pressure gauges to be supplied for each VFD driven pump). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head of each pump using sensorless algorithms.VFD screen should be touch screen Make:- Xylem,Grundfoss,Armstrong
BLANK
(ak) CHILLED/HOT WATER PIPING Design,Supplying, laying/ fixing, testing and commissioning of suitable sizes of chilled/hot water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.),cut to required length, and installed with welded joints (USE RECTIFIER AS SPECIFIED), duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. (al) CONDENSOR WATER PIPING Designing, Supplying, fixing, testing and commissioning of suitable size condenser water pipes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.Pipe must be painted with one coat of anti-rust paint and 02 coats of synthetic enamel paint ,all as specified and directed by engr-in-charge. Note:-i)The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. ii) For under ground pipe : The pipe will be covered by applying 2-4mm thick Tarfelt sheet with required Adhesive ,Accessories etc
(am) VALVES/CONTROLS - Design,supply,install,testing and commissioning of 2/3 way modulating valves with actuator, balancing valves, motorised balancing/modulating valves,NRVs, gate/globe valves,Y strainers,POT strainers, drain valve,water flow switch, air vent valve, pressure switch all to be provided in supply and return line as per requirement. AHUs having DDC Panel must be provided with motorised valve for precise control from BMS workstation. (an) ASSOCIATED ELECTRICAL WORKS Design ,Supply, Install, testing and commissioning of Main LT Panel Indoor type with suitable number of incoming and outgoings fabricated of size as per the existing IEC 60439 Part 1 norms, floor mounted, IP 55 grade, outdoor type double door type LT cubical panel made out of CRCA MS sheet 2.0mm thickduly powder coated Form 4a type with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar 1.5 times of rated incoming capacity, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted on PCC (1:4:8) type D2 of size on as per the panel dimensions such that there should be 600 mm offsets all around th panel complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with CRCA sheets at all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- (a) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link (b) All MCB’s shall be of minimum 10 KA breaking capacity or as metioned in BOQ. (c) The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic adjustable type microprocessor releases as per BOQ and following. i) MCCB rating upto 250 Amps with thermal magnetic releases ii) MCCB above 250 Amps with microprocessor releases. (d) All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic.
(e) Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. i) IP 42 for indoor panels. ii) IP 55/IP65 for ODU panel. (f) All MCCB’s shall be provided with rotary switch (g) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. (h) Providing cable clamps / supports within distribution boards cable alley. (j) Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars. (k) Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment (l) All meter shall be digital type. (m) Current Transfomer shall be resin cast. (n) All Panel Shall be BMS Compitable (m) Current Transfomer shall be resin cast.
(ao) Sub-Panels for AHUs :- Design,supply,install,testing and commissioning of Wall mounted sub panel boards for AHUs, Blower with switch, starters, lamps inter connections, current operated single phase preventer, A/M switch.etc. as per specifications and drawings and as required. (ap) CABLING :- Design,supply,laying on wall/ground/cable trays XLPE aluminium armoured cable/ copper cable/control cabling of equipments of suitable size as per load requirement of equipments from main panel to equipments all as specified and directed. Necessary excavation work is required to be done for cables laying underground min 0.5 m depth and sand min 0.18m(pressed) and PCC cover over it before returning/filling. (aq) TANKS :- Supply and fixing PVC Water tank insulated of 5000 ltr for Cooling Tower and expansion tank of 500L for chilled and hot water line. (ar) VRV/VRF ODU UNITs FOR OTs DesignSupply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.Vendors are allowed to quote only Japanese & Indian brands makes for outdoor units . VRF system to be designed for OTs only. Tonnage to be calculated based on heat load calculations of 04 nos. OT only.
(as) Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application including supply, installation, testing and commissioning of centralized remote control system for monitoring the parameters of entire system from a centralized location. (i) All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control, Refrigerant Cooled PCB, Automatic Refrigerant charge function All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor (ii) All units are Cooling & Heating both with Eco Friendly Refrigerant (R-410a). Unit should deliver 100% capacity without deration upto 43°C Ambient Temperature.Operating Outdoor Ambient Temperature Range Cooling 10°C to 49°C & for Heating 0°C to 24°C. VRF Installation work to be executed by OEM or OEM Authorised Vendor Only. (iii) The bidder is required to submit MOU certificate from the OEM duly signed and stamped for back to back support & Capacity Deration Rating Chart from OEM.
(iv) Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP 3.5 at 100% and minimum 6.5 at 50% Load, at 35 deg C ambient temperature in cooling conditions (To crosscheck COP orginal data sheet to be provided from OEM ) (v) Insurance of Units ,Unloading at site, placement of Outdoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned VRF/VRV by OEM. (vi)Refrigerant topup or charge and refrigerant copper piping of suitable thickness must be included in quoted price (at) BLANK
i) BLANK Notes:- (1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe.
Blank
Supply, Installation, Testing and Commissioning of electrostatic non-chemical scale preventor to prevent rusting of particles on condenser tubes of suitable size to be installed in each condenser pipe line of each chiller unit alongwith all necessary electrical connection, panel, control cabling, complete all as specified and directed.
Blank
FIRE FIGHTING SYSTEM
Supply and fixing fire hose cabinet of size 1000 x 1650mm weather proof fabricated from 18 SWG MS sheet with double front central opening partially glazed with 4mm thick glass with locking arrangement duly painted suitable to house incl 2x15Mtr (two length) of RRL house and hose reel drum with coupling, Branch pipe one firemans axe, first aid hose reel and hydrant outlet, complete all as specified and directed.
M&L construction of valve pit chamber of internal size 900x900x1200mm including necessary excavation, returning filling in, & removal of surplus soil to a distance not less than 250M, 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate ) in foundation, 23 cm thick brick work in cement mortar (1:4), PCC (1:2:4) type B1 (using 20mm graded crushed stone aggegate) for coping including necesary form work, 15mm thick plastering in cement mortar (1:4) including 5mm thick M S Sheet cover fixed on MS angle iron 50x50x6mm duly painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on all steel/iron surfaces and provision of suitable locking arrangement, complete all as specified and directed.
Supplying, installing and commissioning C.I.flanged "Y" type Strainer (PN-16) 80 mm dia with SS mesh, suitable flanges, nuts, bolts, gaskets etc., complete all as specified and directed.
Supply and fixing Pressure reducing valve for controlling the system pressure within specified limits of following sizes : -
Supply and fixing of Automatic air-vent having 15mm end connections, complete all as specified and directed.
Supply and fixing 6 kg capacity Multipurpose dry chemical powder (ABC) type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged, complete all as specified and directed.
Supply and fixing 9 kg capacity dry powder (ABC) type (IS-15683) fire extinguishers consisting of welded MS cylindrical body with valve. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged, complete all as specified and directed.
Supply and fixing CO2 type fire extinguisher of 4.5 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683. Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete with initial filled/charged, complete all as specified and directed.
Supply and fixing mechanical foam extinguisher (stored pressure type) of 9 ltr capacity with steel cylinder with a discharge valve and confirming to IS-15683. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged, complete all as specified and directed.
Supplying, installation, testing and commissioning of test drain assembly of 25mm dia, complete all as specified and directed.
Supplying, installation, testing and commissioning of 5kg automatic modular clean agent fire extinguisher capacity 5 kgs working pressure of 30 kg/cm with discharge time10-15 sec Heat Sensitive Gass bulb sprinkler head. Heat sensitive range 68 degree UL listed clean agent, complete all as specified and directed.
Supplying, installation, testing and commissioning of 2 KG Standalone Compact Automatic Linear pneumatic heat detection tube fire suppression system. Cylinder filled with UL listed clean agent. Cylinder shall be as per IS:15683 and fitted with the direct low pressure (DLP) Valve, Nickel Plated Brass, with integrated ball valve and integrated position control for ball valve. 1. EOL 2. Pressure Switch including suitable master control unit, complete all as specified and directed.
Supplying, installation, testing and commissioning of 4 KG Standalone Compact Automatic Linear pneumatic heat detection tube fire suppression system. Cylinder filled with UL listed clean agent. Cylinder shall be as per IS:15683 and fitted with the direct low pressure (DLP) Valve, Nickel Plated Brass, with integrated ball valve and integrated position control for ball valve. 1. EOL 2. Pressure Switch incl suitable master control unit ,complete all as specified and directed.
Supply and fixing Linear pneumatic heat detection tube for automatic fire detection and suppression system made by special modified Polyamide (PA)- CE APPROVED, complete all as specified and directed.
Supply and fixing fire bucket (Dry sand) of 9 ltr capacity, round shape, handle & floor mount and confirming to IS : 2546. Fire bucket shall be painted with red enamel paint & incription thereon as per relevant IS, complete all as specified and as directed.
Note: Before execution of work contractor shall submit drawings as per NBC norms for approval of Accepting Officer.
HOT WATER SUPPLY SOLAR
M&L for fabrication of stand and ladder arrangements for cold water storage tank from MS angle iron of size 50 x 50 x 6mm and 3.15 mm thick MS base plate including finished with two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer after prepration of new steel surface., complete all as specified and directed.
EMERGENCY LIGHT
Supply, installation & testing of of LED emergency lights rechargeable type including all accessories etc complete all as specified and directed.
SOLAR PHOTOVOLTAICS SYSTEM (SPV)
Supplying, erecting, installing, testing and commissioning of Grid connected Rooftop Solar Photo-voltic (PV) plant of 50 KWp, including mounting arrangements etc, PV output at STC comprising of following sub-components and meeting the specifications as given here-in-after:- Note : (a) Cumulative capacity of inverter shall be 50 KW. Design Structural drawings of module mounting structure along with design calculations shall be submitted by the contractor duly vetted from MNRE approved organisation/ NIT/ IIT/ Govt Research institute. The cost of same shall be deemed to be included in this item. (b) Minimal technical requirements/ standards for SPV systems/ Plants to be deployed as per MNRE are mandatorily to be complied within the design. Some of these are marrated here-in-after. For other details website of MNRE may be referred. (c) The detailed specifications are mentioned at Annexure 'K'. Aneexure 'K' has been uploaded along with the tender documents and is the part of BOQ for all purposes.
MODULAR OT & LIGHT
BLANK
BLANK
Supply, Installation, Testing and Commissioning of Surgeon Control Panel : It should be designed to cope with changing technology and equipment in operating environments. Control panel should be user friendly and ease of operating and maintaining purpose. It should be flush to wall touch screen application for operating theatres, protected by a glass surface that enhances its features and performance in a critical environment of an operating room, coplanar to the finish panel (with the exception of the panels with metallic finish. Touch Screen Surgeon Control panel is recessed box kit for screen 32" approx. 1 x Hardware and software kit for touch screen, with PC intel NUC, PLC and software. 1 x Capacitive touch screen 32" approx size with full HD resolution. It should have IPS alarm and memory for fault status report. The control panel should have feature for On and off and dimming of LAF Light, Peripherial Lights. The control panel should have feature for On and off of OT LED Ceiling Light. The control panel shall accommodate digital clock and the elapsed time display. The control panel should medical gas alarm low pressure display. The control panel should have temperature, humidity and HEPA filter indicator display, complete all as specified and directed. Make: Getinge/ Stryker/ Drager/ Western India Electromedical Systems Pvt Ltd/ Magnatek Enterprises
Supply, installation, testing and commissioning of Double arm moveable Pendant for Anesthetist with following specification :- (a) The Pendants should comply with NFPA 99C/HTM 02-01/DIN. The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position. (b) Double moveable arms (any combination) with total coverage of min 1800mm and 330 deg. Horizontal movements for each arm. Vertical movement should be motorized and the arm height should remain to a height greater than 6.5 feet above floor level. (c) Weight carrying capacity of the arm should not be less than 180 Kg. should have electromagnetic/pneumatic brakes. (d) Each arm should be capable of 300-340 degrees of rotation, which can be easily adjusted to suit the desired mode of operation. (e) The pendant should be European CE Certified or US FDA or BIS approved. (f) The Pendant Service Heads should be modular with minimum 800mm head. The heads should be capable of accepting a range of shelves, infusion poles, electrical switch / sockets, gas outlets other accessories as asked intender. The Pendant Heads should support the range of Physiological Monitor Mounting Solutions. (g) The Pendant Service Heads should be supplied with medical gas terminal units and 5/15 or 6/16 Amps hybrid Sockets (h) Double arm pendant anesthesiologist: Each pendant should be supplied with outlets and probes as mentioned below :- (i) Oxygen outlets - 02 Each, (ii) Vacuum Outlest - 02 Each, (iii) Nitrous Oxide - 01 Each, (iv) Air (4 bar) outlets - 2 Each (v) AGSS Outlest - 01 Each, (vi) Electrical Sockets - 10 Each, (vii) Adjustable Shelf with two rails one on each side - 03 Each, (viii) IV Fluid Pole with 4 hooks - 01 Each, (ix) Data Socket RJ-45 - 02 Each Note : Pendant Supplier should provide cutouts for Patch panes in intefrated OTs. Anaesthettist pendant shouldd havee NIST connectioon for aall gases to connect the MGPS System. Make: Getinge/ Stryker/ Drager/ Western India Electromedical Systems Pvt Ltd/ Magnatek Enterprises
Supply, Installation, Testing and Commissioning of Camera which should be mounted on light head for displaying real-time images during surgery with a Coaxial camera chip of 1.28 CMOS or more than with 2.10 Megapixels capability with at least 12X Digital Zoom and 30X Optical Zoom. Full HD 1080p (1920x1080) image capture and external recording. Camera control should have function like Zoom In / Out, White Balance, Focus In / out, Auto, Aperture In / out, Freeze. All function of HD camera should be controllable through Andriod Tablet PC / voice control & touch Panel. It should be in HD formats 1080i: 1920 x 1080 pixels / 60 frames / sec. Minimum Object distance 10 mm to 1200 mm. Focal Length 4.3 to 129 mm. Shutter Speed 1/1-1/10000 (22 Steps). Signal Noise Ratio 50Db. Output 3G HD-SDI, SMPTE 424M and 292M. Light and Integrated Camera should have a control through Touch Panel of the control equipment placed inside the operating room, complete all as specified and directed
Supply, Installation, Testing and Commissioning of HD LED Flat Panel Monitor (Only for non-integrated MOTs) : (a) It shall be 30”-32” medical grade high definition progressive scan flat-panel monitors with wall mounted to support high definition / HDTV progressive scan images and shall be able to support and display DVI / HDTV, RGBHV, S-video, composite video signals. Aspect ratio 16:9/16:10. Resolution: 1920x1080 or better. It shall meet IP54 regulations. (b) The flat panel shall be ready with the cables for integration of high definition digital (DVI/HDTV), RGBHV (high resolution), SVHS (S-video), composite video signals to travel from the various sources of video like endoscopic camera, room camera, in-light camera, high definition flat panel monitors, while assuring native resolution / signal.
Supply, Installation, Testing and Commissioning of Medical Recording Device with 5 inch touch screen preview of Video Recording and Archiving Device to capture HD photo (up to 1920x1080p) and medical session video recording (up to 1080p 60Hz). The system should simultaneously record to the 2 terabyte internal hard disk drive and an external USB flash drive. It should record 2 sources at once and play back 1 or 2 sources from the same video file. Files to be recorded through a Software for Digitizing and Archiving Data through a password protected to send images in HD-SDI Video Inputs. Simply Use Web Browser interface to access Data on Computer or Tablet Video Recording upto1080P at 60Hz. System controls can be managed using the touch screen and buttons on front of the unit.Should be suitable for storing HD videos from ultrasound, digital X-ray, endoscopic, laparoscopic and other compatible diag Eachtic and surgical imaging systems, complete all as specified and directed. Make: FSN/ Teac
Supply, Installation, Testing and Commissioning of Integrated Wiring from OT"s to Head of Department and Confrence Room for streaming the live video from OTs cameras, complete all as specified and directed.
Supply, Installation, Testing and Commissioning of X-Ray View Panel : The system should electrical safety codes for high & low voltage system. The theatre is to be equipped with a 2-plate X-Ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by 2 pieces of high frequency fluorescent lamps and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. Size of the unit should be not less than 940 mm width x 640 mm height x 50 mm depth. It should be CE compliance under medical devices directive class-1. Copy of CE certificate must be submitted, complete all as specified and directed.
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated materials like polyester or with epoxy powder coating and IP 43 & IK09 protection concealed/surface TPN 8 way 415 volt with bus bar rating 200 Amp dust & vermin proof with and including of MCB TPN 63 Amp and MCB SP 6-32 Amp etc and making all necessary connection, complete all as specified and directed.
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated materials like polyester or with epoxy powder coating and IP 43 & IK09 protection concealed/surface TPN 6 way 415 volt with bus bar rating 200 Amp dust & vermin proof with and including of MCB TPN 63 Amp and MCB SP 6-32 Amp etc and making all necessary connection, complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Operation Threatre (medical grade) Isolation Panel System as per specifications mentioned below: The panels shall be isolated panel system only, having critical (isolated) and non-critical circuits. Both circuits shall be monitored on the building management system. The monitoring parameters shall include On/Off status, load monitoring and shall generate alarms if any critical parameters such as isolation is anomalous. The panel shall enable electrical shock protection: according the IEC 60364-7-710 standard the solution is in compliance with the group 2 location through isolation transformer and associated monitoring system. The system shall be according the IEC standard, the switchgear is energy by 2 separate sourcing. The “Main incomer supply” is coming from the UPS system. The “Safety incomer supply” is coming directly from the other part of the main low voltage switchgear. An automatic change over shall transfer the energy sourcing from the “Main incomer supply” to the “Safety incomer supply” in case of outages in less than 30ms. The Utility and Genset sourcing should limit by 15 seconds at least any potential outage to re-energise the Main and Safety incomers. The wiring shall be in compliance with the recommendations of IEC 60364-4-4-44, IEC 61000-6-2 and IEC 61000-6-3. It shall be possible for the protective devices to be controlled by the maintenance staff, without risk of direct.
The power and communication circuit routing shall be completely separate. Pulse energy meters with inbuilt CTs shall be provided with incomers to the panel for getting the energy consumption data for operation theatre The system should be able to locate faults in case of tripping Communication auxiliaries, for communicating ON/OFF/Trip status shall be provided with all MCBs, RCCBs, RCBOs used for protection. The status shall be available over Modbus TCP/IP network. Smartlink or equivalent shall be used for communicating the status of protection devices.
The System Controller shall transfer all data to BMS room, shall include suitable number of DI/DOs to control and monitor the panels. The controller has 01 Each isolated RS 485 communication port, 1 Each Ethernet communication port with 10BASE-T/ 100BASE-TX, support : Modbus master/slave, BACnet, MBUS and DNP 3.0 protocols, and shall conform to ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007 standards, 230VAC with inbuild 4G modem and has DIDO Capability for adding upto 256 DI/DOs/AI/AOs. The controller sends data with TLS encryption and the data on controller shall be encrypted. The controller shall be able to store data till it is received by the BMS room to avoid any data loss. The system shall have the following components: 63A, FP, Isolator, Complies to IEC/EN 60947-3- 2Each Contactor 60A, FP AC-1 duty 230V 50/60Hz for 10 KVA- 2Each Mechanical interlock for LC1 D60- 1No. On delay Timer 2C/O, 230V AC- 1No. Miniature circuit breaker ACTI 9, C60, 2 poles, 2A, C Curve - 2Each Polybloc 160A 1P - 2Each Miniature circuit breaker ACTI 9, C60, 2 poles, 2A, D Curve- 1No. AC Residual Current Circuit Breaker, 40A, 100mA- 1No. Digital VAF Meter With RS 485 Modbus Port- 1No. Current transformer 40/5A Class 1 10VA- 3Each CT Shorting Links- 3Each
Auxiliary contact, 1 OC- 6Each Multiclip distribution block- 1No. Miniature circuit breaker ACTI 9, C60, 2 poles, 4A, C Curve- 1No. Universal Power Supply 24V DC 5A- 1No. Miniature circuit breaker ACTI 9, C60H-DC, 500Vdc, 2A, 2 poles, C Curve- 1No. IMD Vigilohm IM20-H a positive safety 220/240V AC, 50H- 1No. Current transformer 50/5A class 3 for cable - 1No. Insulation Fault detectors (12 channel)- 1No. Sensor Vigilohm TA30- 6Each Miniature circuit breaker ACTI 9, C60, 2 poles, 16A, C Curve- 6Each Auxiliary contact, 1 OC- 6Each Multiclip distribution block, 4P, 80A, 1 row- 1No. Smart Link Modbus TCP/IP Communicating I/O Module- 1No. Field Controller with Bacnet, Modbus, DNP3.0, MBUS protocols- 1No. Prefabricated Cables, Long: 870mm- 1No. 15KVA Isolation Transformer 3Phase, 415V/220 V AC- 1No. Prisma Panel Type Tested IEC 61349- 1No. Or equivalent of above
Supply, installation, testing & commissioning (SITC) of BSI Kite Mark Certified Copper Pipes : It should be confirm and meets with BS:EN:13348:2016 copper pipes: All medical grade degreased copper pipes. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW 024A ( Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2016, Degreasing of pipe shall be such that there is less than 20 mg / m2 (0.002 mg / cm2) of hydrocarbons on the degreased surface when tested by the method specified BS: EN: 13348:2016, complete all as specified, directed of the following sizes :-
(a) SITC of BSI Kite Mark Certified Copper Pipes of 54mm with thickness of 1.2mm.
(b) SITC of BSI Kite Mark Certified Copper Pipes of 42mm with thickness of 1.2mm.
(c) SITC of BSI Kite Mark Certified Copper Pipes of 28mm with thickness of 1.0mm.
(d) SITC of BSI Kite Mark Certified Copper Pipes of 22mm with thickness of 0.9mm.
(e) SITC of BSI Kite Mark Certified Copper Pipes of 15mm with thickness of 0.9mm.
Supply, installation, testing & commissioning (SITC) of Line Ball Valves: It should fully complies and meets with the requirements of the HTM 02-01 / NFPA -99 Recomendations All ball valves as per BS 1057 are rated at 400 psig, as well as full vacuum ( 29.9" Hg). Valves go from full ON to full OFF by turning the vinyl-gripped valve handle 90 ° Locking-type handles may be ordered separately when required. Copper tubing is factory installed to help prevent valve seat damage during soldering. Main and riser valves are not required to be installed in a box unless specially noted or required. It should be duly CE markd with 4 digit notified body number or UL /ETL listed whereever applicable. All line valves - Supplied with a mechanism to enable the unit to be locked in the fully closed or fully open position, complete all as specified, directed of the following sizes :-
(a) SITC of Line Ball Valves of 54 mm size with pipe stub on both sides
(b) SITC of Line Ball Valves of 42 mm size with pipe stub on both sides
(c) SITC of Line Ball Valves of 28 mm with pipe stub on both sides
(d) SITC of Line Ball Valves of 22 mm with pipe stub on both sides
(e) SITC of Line Ball Valves of 15 mm with pipe stub on both sides
Supply, installation, testing & commissioning (SITC) of Area Valve Service Units for 3 Service : It should fully complies and meets with the requirements of the HTM 02-01 or NFPA 99. Bidder must submitted third party CE certification I UL listed along with tender documents. Self attested certificate not valid. Adopter having opening by quarter turn of handle. The valve should be pneumatically tested as per BSEN 1057 for twice the working pressure and degreased for medical gas service before supply. Valve boxes should be equipped with components for shutting off and supervising individual /parts of central systems in hospital, laboratories and the like. They should be allowed the ward staff to allow isolating of the areas for maintenance and repair work. The pressure monitoring of the distribution system is done by pressure gauges. In case of emergency the door can be glass break opened or by un-locking using the key, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of Area Valve Service Units for 5 Service : It should fully complies and meets with the requirements of the HTM 02-01 or NFPA 99. Bidder must submitted third party CE certification I UL listed along with tender documents. Self attested certificate not valid. Adopter having opening by quarter turn of handle. The valve should be pneumatically tested as per BSEN 1057 for twice the working pressure and degreased for medical gas service before supply. Valve boxes should be equipped with components for shutting off and supervising individual /parts of central systems in hospital, laboratories and the like. They should be allowed the ward staff to allow isolating of the areas for maintenance and repair work. The pressure monitoring of the distribution system is done by pressure gauges. In case of emergency the door can be glass break opened or by un-locking using the key, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of Area Alarm for 3 Gas service: It should fully complies and meets with the requirements of the HTM 02-01 standards or NFPA-99 Standards recomendations and standards mentioned under these recomendations or applicable. . It shall be provided with a copy of the certificate of origin. Area Alarms are designed to include all necessary displays, factory wiring, transformers and circuitry requiring only 230 VAC primary powers. Internal voltage should be stepped down to S VDC and 1S VDC for control circuit Power. Voltage to external pressure or vacuum transducers should be 1S VDC. The Area Alarm should have digital display facility. Area alarm panels should be modular in design. Each gas monitored should have a light Emitting Diode (LED) display to continuously indicate actual line pressure. A vertical series of LED's should further indicate relative line pressure. The LED should show Normal pressure at SO psi. Apart from Normal it should also show low risk of 40 PSI as low-pressure and 60 psi as high. High risk of 30 psi as low pressure & 70 psi as High pressure. The back box should contain factory installed copper tube extensions 6" Long, 3/8" ID (1/2"0D) , to accept installer furnished lines form the medical gas system. Each inlet tube should accept gas - specific DISS fittings for transducers, to prevent cross-connection. The power supply should be installed in the back box Power supply should include an on I off rocker switch and a fuse holder. The audible alarm tone should pulsate, 90 dBa at 2 meters. The audible signal should be cancelled only by the alarm silence button or fault correction. The display should remain illuminated to indicate the presence of the alarm condition. The alarm should automatically reset with the correction of the fault condition. Should a new alarm occur while the panel is silenced, the audible alarm should reactivate. The area alarm should store the last four alarm conditions in memory at the alarm panel. These conditions can be indicated by using the buttons on the alarm panel control module, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of Area Alarm for 5 Gas service: It should fully complies and meets with the requirements of the HTM 02-01 standards or NFPA-99 Standards recomendations and standards mentioned under these recomendations or applicable. . It shall be provided with a copy of the certificate of origin. Area Alarms are designed to include all necessary displays, factory wiring, transformers and circuitry requiring only 230 VAC primary powers. Internal voltage should be stepped down to S VDC and 1S VDC for control circuit Power. Voltage to external pressure or vacuum transducers should be 1S VDC. The Area Alarm should have digital display facility. Area alarm panels should be modular in design. Each gas monitored should have a light Emitting Diode (LED) display to continuously indicate actual line pressure. A vertical series of LED's should further indicate relative line pressure. The LED should show Normal pressure at SO psi. Apart from Normal it should also show low risk of 40 PSI as low-pressure and 60 psi as high. High risk of 30 psi as low pressure & 70 psi as High pressure. The back box should contain factory installed copper tube extensions 6" Long, 3/8" ID (1/2"0D) , to accept installer furnished lines form the medical gas system. Each inlet tube should accept gas - specific DISS fittings for transducers, to prevent cross-connection. The power supply should be installed in the back box Power supply should include an on I off rocker switch and a fuse holder. The audible alarm tone should pulsate, 90 dBa at 2 meters. The audible signal should be cancelled only by the alarm silence button or fault correction. The display should remain illuminated to indicate the presence of the alarm condition. The alarm should automatically reset with the correction of the fault condition. Should a new alarm occur while the panel is silenced, the audible alarm should reactivate. The area alarm should store the last four alarm conditions in memory at the alarm panel. These conditions can be indicated by using the buttons on the alarm panel control module, complete all as specified and directed.
Supply and installation of BPC single type pipe line flow meter with humidifier bottle including pressure gauge, flow adjuster, screw cap, pressure reducing valve, safety vlave complete testing and commissioning, complete all as specified and directed.
Supply and fixing Ward vacuum unit incl Vacuum Jar capacity 600 ML with vacuum regulator including connected items, complete all as specified and directed.
Supply and fixing Theatre vacuum unit incl Theater vacuum unit shall be Analog type regulator with gauge (size 2 and 1/2 inches) with gauge accuracy + 1% of full scale color coded range. The unit shall have 3-Mode High feature and equipped with push to set technology which shall automatically establish vacuum. Limit with each vacuum level setting. The vacuum unit shall have a precision in the critical care range (0-200mm hg) and should provide fast adjustment with turns of the knob up to full wall vacuum thus should instantly facilitate regulated and continuous suction for tracheal and pharyngeal airway management, surgical procedure and continuous drainage which shall facilitate unrestricted full time vacuum for emergency. The unit shall be equipped with Positive Pressure Relief Valve to protect patient and unit both in case if accidentally connected to pressurized gas (O2, Air etc), complete all as specified and directed.
M&L for decorative bed side panel with outlet for Oxygen, Vacuum & air with outlets 06 gases with matching prob incl 06 Nos 15 Amp point incl. switch and socket provision excluding all connected accessories i.e BPC flow meter /humidifier bottle/Vacuum jar /Oxygen flow meter etc, complete all as specified and directed.
Supply, installation, testing & commissioning high pressure tubing as per CE certified / UL listed for oxygen, vacuum, air, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of oxygen manifold with 8 Nos pigtail pipes for 4 +4 cylinders and non return valves The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 8 cylinders in each Bank (means 4+4) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves conforming to IS 3234 (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4" I. D. x 15 swg, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of fully automatic oxygen control panel as per HTM-2022/02-01 The main source supply will be liquid tank Oxigen, control panel should be capable with auto switch over facility when ever required with all required fittings and accessories required for noraml running of the system. Gas Manifold should be fully automatic, self- shifting to reserve bank on exhaustion of the service bank without interruption of gas delivery to the system. Critical connections should be gas specific, non- interchangeable and should be designed to eliminate gas supply error. The manifold control system should supply a flow of 2000 L/ Min at 50 psi. The dual line regulator/single vent Medical Gas Manifold control unit should include right and left header bars and pigtails for the appropriate medical gas. The installed system should automatically switch over to the reserve bank when the primary bank is depleted. When the depleted cylinders are replaced with full cylinders the system should automatically reset itself in preparation for the next bank change. The primary side bank in use and the remaining side bank on reserve. This designation should automatically change from left to right and right to left as each bank is depleted and, in turn, refitted with full gas cylinders, complete all as specified and directed.
Supply, installation, testing & commissioning (SITC) of Oxygen Manifold Emergency for 8 cylinders, The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 2+2) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves conforming to IS 3234 (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold.Top frame comprising of high pressure copper pipes of size 1/2" I. D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4" I. D. x 15 swg. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation, complete all as specified and directed.
M&L for MS pipe 80 mm dia medium grade with continuous welding with necessary items for supporting MS structure including one primer coat or red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed as required at site, complete all as specified and directed.
S&F Hospital sign bd of different types and size i.e. illuminated and others for depiction of various wards, deptts, centres, services and other locations in the hospital incl day and night signs and patient guidence system, complete all as specified and directed. Note for all MGPS items : All items should be duly CE marked with 4 digit notified body number or HTM 02-01 or NFPA 99/ UL listed.
M&L for SS 304 wall panelling in OT complex including necessary GI profile formwork along the periphery & GI intelocking section with base runner framework with following Specifications: - The wall panel will consist of sandwiched wall panels. Front side of the panel shall be SS 304 sheet, 0.8 mm thick & back side PPGL sheet, 0.5 mm thick with core consisting of rigid polyurethane PUFF with 40 Kg/cum density. Standard panels shall have an overall thickness of 50mm to 60mm. The self-supporting internal walls are constructed with PPGL frame work. Partition to partition connections shall be maintained with precision with PPGL profiles that create uniform seams. No welding shall be allowed. It shall have minimum number of junctions. The Partition seams shall be sealed by silicone with a perfectly flush finishing. Stainless steel plate shall be finished to fine grain surface, and treated properly to take antifungal paint. Paneling shall be easy to maintain, durable, antistatic/conductive and fire retardant. Angular corners shall be made with a 130°-140° angular modular element with the same finish of the wall panels, complete all as specified and directed. Note :- Necessary openings if any required at site shall be provided by the contractor for fixing of switch boards / panels / equipment etc. and unit rate quoted shall be deemed to be inclusive of this aspect. Make/Manufacturer : Western India Electromedical Systems Pvt Ltd / Tanvi Enterprises/ Magnatek Enterprises/ Lifewise Healthcare.
M&L for Toughened glass wall panelling in OT complex incl necessary GI profile formwork along the periophery & GI intelocking section with base runner framework with following Specifications: - The wall panel consist of high quality 8mm thick back printed toughened glass. The printed toughened glass will use UV multicolor printing technology with PU glass coating . Front side of the panel shall be 8mm thick back printed toughened glass & back side PPGI sheet, 0.5mm thick with core consisting of rigid polyurethane PUFF with 40 Kg/cum density. Standard panels shall have an overall thickness of 50mm to 60mm. The wall panel should E section frame work with a sealed and PUFF insulated with 40 Kg/sqm density. Standard panels shall have an overall thickness of 50mm to 60mm. The self supporting internal walls are constructed with an interior of PPGI frame work. Partition to partition connections are maintained with precision with PPGI frame work partition to partition connections are maintained with precision with PPGI profiles that create uniform seams. The Partition seams are sealed by silicone with a perfectly flush finishing. PUF insulation material is sandwiched between the skin layers and sealed from the exterior by the PPGI frame work. (a) Panel Thickness: 50 mm to 60mm with inner skin is of Toughened Glass (8mm) and outer skin 0.5 mm PPGI thick sheets, complete all as specified and directed. Note :- Necessary openings if any required at site shall be provided by the contractor for fixing of switch boards/panels/equipment etc. and unit rate quoted shall be deemed to be inclusive of this aspect. Make/Manufacturer :Western India Electromedical Systems Pvt Ltd / Tanvi Enterprises/ Magnatek Enterprises/ Lifewise Healthcare.
M&L for SS 304 ceilling panelling in OT complex with following specifications:- Standard ceiling partitions with composite construction of SS 304 sheet of 0.8mm thick from side back sie 0.5mm thick PPGI sheet for construction of wall panel. The wall panel should E section frame work with a sealed and PUFF insulated with 40 Kg/sqm density. Standard panels shall have an overall thickness of 50mm. The self supporting internal walls are constructed with an interior of PPGI frame work. Partition to partition connections are maintained with precision with PPGI profiles that create uniform seams. The partition seams are sealed by silicon with a perfectly flush finishing. PUF insulation material is sandwiched between the skin layers and sealed from the exterior by the PPGI frame work. (a) Type:- Walkable (b) Panel thickness: 50mm with inner SS 304 (0.8mm) and outer skin 0.5mm PPGI thick sheets, complete all as specified and directed. Note :- Necessary openings if any required at site shall be provided by the contractor for fixing of switch boards/panels/equipment etc and unit rate quoted shall be deemed to be inclusive of this aspect. Make/Manufacturer: Western India Electromedical Systems Pvt Ltd/ Tanvi Enterprises/Magnatek Enterprises/Lifewise Healthcare
Supply installation testing commissioning of Anodized clip on type coverings for the entire wall to wall and wall to ceiling. 3D internal/external corner covers. Covering and coving of return air ducting lines inside OT, material to be used for covering should be SS-304, complete all as specified and directed. Make/Manufacturer : Western India Electromedical Systems Pvt Ltd/ Tanvi Enterprises/Magnatek Enterprises/Lifewise Healthcare
Supply, Installation, Testing and Commissioning of hermatically sealed automatic sliding doors: Size 1500mmX2100mm, MOC: SS 304 Hermatically sealed sliding door designed to fit flush into the wall on both sides. Door operations: Automatically operated door. The door runs on nylon wheels within an aluminium extrusion track, for smooth effortless sliding. Track- Aluminium anodised profile-90x110mm, Door blade-60mm with both side SS 304, Door panel insulation: PUF insulation 48mm @ 40Kg/m3, Controls & Safety features: Microprocessor based electronic automation for door controlling the direction of movements, acceleration and speed of the door, with a low noise level pulse generator motor. It includes a photocell for user's safety, Radar hand switch & foot switch. With 2mm Accessories-Vison Panel size 300mmx300mm, The lock can be locked and unlocked both sides by means of a euronom cylinder and should have hermatic sealing designed & tested on hermatically sealing an over pressure of 100 Pa. The air tightness should be 99.997% airtight. The door should be designed in consultation with doctors/Architects and technical bureau who design operation theaters and clean rooms, complete all as specified and directed. Make/Manufacturer: Western India Electromedical Systems Pvt Ltd/ Meta Flex/ Ribbon/ Geze
Supply, Installation, Testing and Commissioning of hermatically sealed automatic sliding doors: Size 1000mmX2100mm, MOC: SS 304, Hermatically sealed sliding door designed to fit flush into the wall on both sides. Door operations: Automatically operated door. The door runs on nylon wheels within an aluminium extrusion track, for smooth effortless sliding. Track- Aluminium anodised profile-90x110mm, Door blade-60mm with both side SS 304, Door panel insulation: PUF insulation 48mm @ 40Kg/m3, Controls & Safety features: Microprocessor based electronic automation for door controlling the direction of movements, acceleration and speed of the door, with a low noise level pulse generator motor. It includes a photocell for user's safety, Radar hand switch & foot switch. With 2mm. Accessories-Vison Panel size 300mmx300mm, The lock can be locked and unlocked both sides by means of a euronom cylinder and should have hermatic sealing designed & tested on hermatically sealing an over pressure of 100 Pa. The air tightness should be 99.997% airtight. The door should be designed in consultation with doctors/Architects and technical bureau who design operation theaters and clean rooms, complete all as specified and directed. Make/Manufacturer: Western India Electromedical Systems Pvt Ltd/ Meta Flex/ Ribbon/Geze
Supply and installation of storage unit in OT area 200x120x35cm deep having two shelves and Mounted flush wall with and including following:- (i) Each modular OT and passage area shall have flush mounted storage units. (ii) The storage is made of 0.8mm thick SS 304 on both side. (iii) shutter width of 45x50mm with a sealed & PUFF insulated with 40 Kg/Sqm density. (iv) The numbers of selves are 4 at the equal-distance. (v) View glass of size: 250mm x 1300mm x 5mm Thick (vi) Masonry work: Any masonry work required for installation of storage unit is included. Make/Manufacturer: Western India Electromedical Systems Pvt Ltd/ Tanvi Enterprises/Magnatek Enterprises/Lifewise Healthcare
S&F FLOOR MOUNTED AUTOMATIC SURGICAL SCRUB -2 BAY Floor Mounted Scrub Sink are constructed of 1.2 thickness, type 304 stainless steel with horizontal and vertical corners coved to ¼” radius. Front corners are to be welded and all welds ground and polished to MAT finish. Sinks shall have sloping basin to eliminate back splash. Each station shall be equipped with 1.5” stainless steel drain. Outer enclosure is constructed of 18 gauge stainless steel. Quality Requirement : - Material S.S 304-18 SWG - Scrub Dimension : 1300W X 883H X508D - Perfect Matt Finishing of product. - Operation -Automatic OR Foot operation - Taps- Jaguar Make- 2 No. - 2 liquid detergent container, Flashback and with nylon adjustable levelling bullets for legs. - Branded Piping Material using like Astral Pipe. - Easy to clean Surface . - Radius Chamber. Make/Manufacturer : Western India Electromedical Systems Pvt Ltd / Window Techs / Tanvi Enterprises/ Magnatek Enterprises/ CMP/ Lifewise healthcare
S&F Magnetic writing board with duster Colour - Pure white Size : 600mm x 800mm MOC : Magnetic laminated board bonded with 10mm high density fibre board sheet with magnetic duster Thickness - 1.50 mm thick Make/Manufacturer : Western India Electromedical Systems Pvt Ltd / Window Techs / Tanvi Enterprises/ Magnatek Enterprises/ CMP/ Lifewise healthcare
M&L for Antistatic conductive vinyl flooring Compliant to standards: EN 1081/IEC 613404, EN 1815 & EN 12466, TVOC as per AgBB / DIBt Certifications, ISO 16000-6. Thickness 2.00mm, polyurethane reinforced ,scratch resistant, fire resistant, chemical resistant , slip resistant, anti-fungi & bacterial growth , dimensional stability ≤ 0.40%, static electrical charger < 2Kv,. Flooring should be seamless with perfectly curved flush- coving, resistant to mechanical stress and dynamic loads and having protection characteristic, Conductive Washable vinyl in Roll form. Flooring should be laid on epoxy based self-levelling compound, complete all as specified and directed. Make/Manufacturer :Tarket/ Gerfloor/ HR Johnson/ Floormaster/ Accord Floors
S&F Doubled toughened glass window providing and establishing the view windows of size 1.00 m x1.00 m with following specifications: It should be provided with each operation theatre and should have double isolated fixed glazing with not less than 5 mm thick toughened glass on both sides with 12 mm air gap. Window frame should be of Stainless Steel of approved shape flush mounted with wall panelling should have dynamic control over amount of light and heat passed through the surfaces. Window (Size: - 1000 mm x 1000 mm) with both side glass with blinds sandwiched in between. The blinds should be openable from inside the O.T and shall be magnetic operated, complete all as speccified and directed.
SITE CLEARANCE
M&L for approved earth filling from outside of MOD land in floors or pavings , laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of distribution net work, 11 kv outdoor compact Sub Station totally factory assembled (non walk in type) consisting of RT2 RMU type, 1 No. 11KV/433V, 500 KVA with Mineral Oil type transformer, 1 set of LT device as under. Approved Makes- Schneider/ ABB/ Siemens Note: (a) Annexure 'J' has been uploaded along with the tender documents and is the part of BOQ for all purposes. (b) The CSS and all accessories / fittings shall conforming to relevant IS with latest amendments. (c) Completion of the work shall be issued after precommisioning of CSS inspection by Testing Officer. Necessary tools and equipment shall be provided by the contractor for testing / precommsioning without any extra cost
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 1600 Amps, 50 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 630 Amps, 50 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking, 400 Amps, 35 kA SC for 1 Sec, (3L+N+PE), with Multi Layer Class-F Insulation, 100% N, Totally enclosed with 1.6mm thick GI Sheet, Dust & vermin proof with IP-55 (Indoor Type) Ingress Protection, incl 90 degree bends / elbows etc, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Each aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 1600 Amps, 50 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 630 Amps, 50 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking/ rising mains, testing and commissioning of 400 Amps, 30 kA SC for 1 Sec, capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB / ACB (but without MCCB / ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking / rising mains, testing and commissioning of 200 Amps, 15 kA SC for 1 Sec, capacity Plug In / Tap Off Box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB (but without MCCB) as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S.
Supplying, installing, connecting to existing Air Insulated Compact Type bus trunking / rising mains, testing and commissioning of 125 Amps, 15 kA SC for 1 Sec, capacity Plug In / Tap Off Box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB (but without MCCB) as required, complete all as specified and directed. Make : LK / Legrand / Sudhir- Schneider / ABB / C&S.
S&F SITC of Street light control panel, outdoor type with the following :- (a) MCCB 100 A, 4P, 25kA, TMD - 01 No (Incomer) (b) MCB 40 A, 4P, 10 kA - 04 Each (O/G) (c) MCB 32 A, 4P, 10 kA - 03 Each (O/G) (d) MCB 32 A, DP, 10kA - 02 Each (O/G) (e) Contactor 63 A, 3P - 01 Each (f) Digital timer (Astronomical type) for auto on /off - 01 Each Notes : (a) Detailed Specification has been uploaded along with the tender documents at Annex 'I' and is the part of BOQ for all purposes. (b) All acccessories included in the panel cost such as MCCB, MCBs, rotary handles, and its accessories & metering etc. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel.
S&F Cable route indicator made out of stone patties size 10cmx15cmx60cm in lengths duly engraved and painted with (HT Cable) with projection of 30 cm above ground level and 30 cn grouted in foundation including PCC foundation etc, complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply, laying and testing of ductile iron pipe 100mm bore of class K9 with spigot and socket ends suitable for tyton jointing (push on rubber gasket joint) with cement mortar lining inside and bituminous coating outside, complete as per IS:8329, laid in trenches, testing after completion, complete all as specified & directed.
Supply, fixing including jointing and testing of cast iron butterfly valves of size 100 mm bore as per BS EN 593 body cast iron IS:210 Fg 260 type 410 saet nitrile/EPDM rubber ends, wafer type to suit mounting between flanges with hand lever, class PN-16 with nuts, bolts, washer, complete all as specified & directed.
Supply, fixing including jointing and testing of cast iron butterfly valves of size 80 mm bore as per BS EN 593 body cast iron IS:210 Fg 260 type 410 saet nitrile/EPDM rubber ends, wafer type to suit mounting between flanges with hand lever, class PN-16 with nuts, bolts, washer, complete all as specified & directed.
S&F Ductile iron fittings for spigot and socketed/flanged pipes upto and including 150mm bore such as bends (any type, radius and angle), Taper any type, (straight, bend, increasing, decreasing or double socket etc.), Tee pieces, single branch, `Y’ Junction, double branch, cross (all sockets or socket and spigot), collar, caps and plugs, complete all as specified and directed.
M&L for cutting of existing DI/MS pipeline of 150/100 mm dia bore/size in position for insertion of 01 No tee of required size and bore connecting pieces/flanged/socketed/ spigoted of suitable bore and making run lead/flanged joint, complete all as specified and directed.
SEWAGE DISPOSAL
M&L for RCC Septic tank conventional type design to carry sewage and sludge water ecxavation in any type of soil , PCC 1:4:8 in foundation and RCC M-30 Design Mix in walls base slab and Roof slab including Beam and vent saft complete with effective depth of 1.5 mtr and overall depth of 3.00 mtr for 150 users, complete all as specified, directed and shown on drawings.
M&L for Sockage well 3.60 mtr dia and 6.00 mtr effective depth in any type of soil , foundation in PCC 1:3:6, walls of hony comb masonry with top ring of M-25 concrete including intersepting chamber and screen chamber made of brick massonary, RCC cover slab in M-25/SFRC cover ,interconnecting pipe/ RCC / DWC complete filled with brick bats, complete all as specified, directed and shown on drawings.
AREA DRAINAGE
M& L for drilling 300 dia bore hole by DTH cum Rotary at any depth below the ground level any kind of rock/soil upto 100 m depth including disposal of surplus soil to a distance of not exc 50 m, complete all as specified and directed.
M&L for perforated 250 mm dia UPVC pipe of pressure rating 10 Kg/Sqcm fixed to wall/ceiling/floor, complete all as specified and directed.
Aalaya Engineering Project Private Limited (BID ID -3300066)
surendra infrastructure pvt ltd (BID ID -3300473)
Jeet Construction (BID ID -3300008)
SOOD ASSOCIATES PVT LTD (BID ID -3300884)
Ktech Engineer Builders Co. Pvt. Ltd (BID ID -3301023)
LUMOS INFRA PVT LTD (BID ID -3300842)
Pooja Singla Builders And Engineers Pvt Ltd (BID ID -3299412)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3300939)
AMIT ASSOCIATES (BID ID -3297780)
SOOD ASSOCIATES PVT LTD (BID ID -3300884)
Ktech Engineer Builders Co. Pvt. Ltd (BID ID -3301023)
LUMOS INFRA PVT LTD (BID ID -3300842)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3300939)
surendra infrastructure pvt ltd (BID ID -3300473)
Pooja Singla Builders And Engineers Pvt Ltd (BID ID -3299412)
Jeet Construction (BID ID -3300008)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid