Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.5 LAccepted-AOC | ₹21.5 L | L-1 | Accepted-AOC Award |
Tender Value
₹20.0 L
EMD Value
₹39,957
Closing Date
28 Dec 2021, 6:00 pmClosed
Executive Engineer
WSS Division No. 3, SAS Nagar
Providing and Installing one no. New Tubewell of size 250x200mm I/d upto 300 mtr Depth with Reverse Rotary Rig in place of failed Tubewell for Water Supply Scheme Barouli at existing water works site Block Derabassi, Distt. Sahibzada Ajit Singh Nagar
2021_WSS_79523_1
9192-93 dt 15.12.2021
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
90 days
SAS Nagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
₹39,957
Yes
11 Jun 2024
17 Dec 2021
29 Dec 2021
17 Dec 2021
28 Dec 2021
17 Dec 2021
Amount
Drilling of 550mm dia bore with reverse rotary rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. Complete in all respects (refer analysis)
Drilling of 550mm dia bore with reverse rotary rig upto 150 mtr depth BGL.
Drilling of 550mm dia bore with reverse rotary rig beyond 150 mtr depth upto 300 mtr depth
1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of Water and Water for drilling tube-well be arranged by the firm/ contractor at site at his own cost.
2. In case the bore is converted into a tube-well payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling.
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect.
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
250mm Nominal Diameter (Weight 52.3 kg/mtr) 8.00mm Thickness
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, fixing and lowering of stainless steel cage type wite wound screen as per , ISI 8110-2000 or latest ISI marked , duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore .
200mm internal diameter (slot size 0.75mm) 6.30 mm thickness
Supplying and fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects.
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Providing and fixing M.S. taper / reducer made out of 6 mm thick M.S. sheet complete in all respect.
Reducer 250mm x 200 mm
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.
200mm Internal Diameter
Supplying, lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respects.
200mm Internal Diameter
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
250mm Internal Diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments .( to be paid as per actual length of pipe)
Supplying of tibba sand /local sand over gravel packing & clayseal, upto G.Level between pipe assembly and bore including carriage . Complete job in all respect (upto 90 mt depth approx.) (as per IS 2800-2019)
Supplying and fixing sanitary seal having rubber tight on housing pipe . Complete job in all respect 250 mm dia (as per IS 2800-2019)
Supplying of clay to provide imprevious layer in between pipe assembly and bore above gravel packing including carriage of material. Complete in all respect. (as per IS 2800-2019)
Supplying and fixing Mild steel centering guide made out of 32mm x 6mm thick M.S. bar complete in all respects.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, uraniam pesticide etc.)
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 550 cfm at 600 PSI
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Provision for Sterilisation of tubewell with sodium hypochorlide/ chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well .The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time , the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water . IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce.
Rising Main
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation.
110mm o/d pipe of 10kg/sqcm
Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications.
Pumping Machinery
Supplying lowering of 80 mm dia GI D/F pipe ISI marked as per IS 1239 including of sepecial such as sockets , cuting , threading and welding etc.; Complete in all respects
Providing for automated Water Controller and connection with old control panel complete job
Repair of 160mm dia delivery main as per site coditions the repair consisting of the replacement of rubber, flange/nut bolts connection of new tubewell with old delivery main complete job
Credit for old 80mm dia GI column pipe complete job
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .