Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.3 LAccepted-AOC | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹14.8 L+₹3.5 L (31.1%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹16.7 L+₹5.4 L (47.6%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical Rejected due to non submission of MRO |
Tender Value
₹19.8 L
EMD Value
₹39,540
Closing Date
3 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
REPAIR/ MAINTENANCE OF GEYSERS, FITTING AND FIXTURES, CONNECTED ACCESSORIES ETC AT PINTO PARK, CAMP AREA, MAUDE LINE, RV AREA AND TECH AREA UNDER GE (AF) PALAM, DELHI CANTT-10
2022_MES_543420_1
GENP-47/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹39,540
Yes
24 Apr 2023
4 Aug 2022
5 Sept 2022
4 Aug 2022
3 Sept 2022
20 Aug 2022
Amount
Taking down electric water heater/ geysers of capacity 25 ltrs from its mounting place for repair and deposit to MES complaint cell and re-fixing the same after repair and testing complete all as specified and as directed by Engr-in-charge. (NOTE : The spare parts/items required for repair will be measured and paid seperately).
All as per item No.1 here-in-before but geyser of capacity 35 ltrs.
All as per item No.1 here-in-before but geyser of capacity 50 ltrs.
S&F in replacement of heating element of 1.5 KW rating double tube type with cup type of circular/triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete.
S&F in replacement of heating element of 2 KW rating double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete.
S&F in replacement of complete set of round shape element holding assembly attached with heating element and thermostate made out of brass of capacity 2 KW rating 230V, 50 Hz, including rubber washers suitable to fit in the existing geyser without any water leakage complete.
S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacity geysers as per site requirement complete.
All as per item No. 7 here-in-before but suitable for capacity 35 ltrs.
All as per item No. 7 here-in-before but suitable for capacity 50 ltrs.
S&F in replacement of heavy duty element holding assembly with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement suitable for 25 litres capacity geysers.
All as per item No. 10 here-in-before but suitable for capacity 35 ltrs.
All as per item No. 10 here-in-before but suitable for capacity 50 ltrs.
S&F in replacement of appretus plate (Geysers assembly) suitable for existing geysers of capacity 25 ltrs of copper/brass complete with nuts and bolts and rubber washer complete all as specified and as directed.
All as per item No. 13 here-in-before but for 35 ltrs capacity Geyser.
All as per item No. 13 here-in-before but for 50 ltrs capacity Geyser.
S&F in replacement of vertical non return valve 15 mm dia GM including GI fitting such as union, nipple, elbow, socket etc as required at site complete.
S&F for glass coating stainless steel inner tank 24 gauge heavy duty including dismantling of existing stainless steel inner tank suitable for the existing 25 ltrs capacity geysers complete.
All as per item No. 17 here-in-before but for 35 ltrs capacity Geyser.
All as per item No. 17 here-in-before but for 50 ltrs capacity Geyser.
S&F in replacement of thermostate for the geysers 25 Ltrs. capacity as per site requirement complete.
All as per item No 20 here-in-before but suitable for 35 ltrs capacity geysers.
All as per item No 20 here-in-before but suitable for 50 ltrs capacity geysers.
S&F in replacement of safety valve/high pressure valve 15mm, as per site requirement complete.
S&F in replacement of insulating material i.e. glass wool complete.
S&F in replacement of chromium plated copper connecting pipe 450 mm long with two brass nut and nylon washer suitable for 15mm dia pipe and connecting up complete.
S&F in replacement of heavy duty PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engr-in-charge.
S&F in replacement of PVC insulated, PVC sheathed with stranded copper conductor cable 1100 Volt grade flexible 3 core of size 2.5 Sqmm.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 6-32 Amp complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of suitable fastener for geyser complete.
S&F in replacement of top cover made of MS sheet, 20 SWG duly painted with two coats of super enamel paint by spray painting complete suitable for 25 ltrs geysers.
All as per item No 30 here-in-before but 35 litres geyser.
All as per item No 30 here-in-before but 50 litres geyser.
S&F in replacement of bottom cover made of MS sheet, 20 SWG duly painted with two coats of super enamel paint by spray painting complete suitable for 25 ltrs geyser.
All as per item No 33 here-in-before but 35 litres geyser.
All as per item No 33 here-in-before but 50 litres geyser.
S&F in replacement of indicating lamp red or green as per geyser suitability complete.
S&F in replacement of outer body made/fabricated of 22 gauge MS sheet for Geysers of 25 Litres capacity duly painted with spray paint with clamps 2 Nos of size 15mm x 3mm thick with necessary nut and bolts complete.
All as per item No 37 here-in-before but for geyser of 35 ltrs capacity.
All as per item No 37 here-in-before but for geyser of 50 ltrs capacity.
S&F in replacement for submain wiring with two single core 4.0 sqmm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4 sqmm FRLS multistrand copper conductor cable as continuous earth wire complete.
S&F in replaccement of poreclain socket outlet 3 pin, 1 phase + 01 neutral suitable for metal clad socket complete.
S&F in repalcement of metalic plug top 3 pin, 2 phase + 01 neutal suitable for metal clad socket complete.
S&F in replacement of MCB, SP, 240V, AC, 10 KA of capacity 16-32 Amps.
M&L for painting of geyser of capacity 25 & 50 ltrs complete at site or in store with one coat super synthetic white paint by spray machine including filling cavities with filler after cleaning all dust etc complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of steel tubes, medium grade , galvanised with all fittings and fixture such as bends, tees, elbows, reducers, unions, plug and socket etc of 15mm bore all as specified and directed by Engr-in-Charge.
S&F in repalcement of stop cock, cast copper alloy, fancy type, long shank and cup, chromium plated, hot or cold marked , with crutch or butter fly handle, screwed down, high pressure for iron pipe/fittings or for brass ferrule of size 15mm dia all as specified and directed by Engr-in-Charge.
Grid Infratech Pvt Ltd
MAHABIR SINGH
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .