Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC G C ROAD ABDUL LATIF ROAD PO TITAGARH P S RAHARA KOLKATA 700 119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹29.6 L+₹1.1 L (3.83%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.7 L+₹4.1 L (14.5%)Rejected-Finance 21 20 BT ROAD KHARDAH PO TITAGARH PS KHARDAH DIST NORTH 24 PARGANAS KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.2 L+₹4.7 L (16.4%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.6 L+₹5.0 L (17.6%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
13 Oct 2023, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF CERTAIN MISC B/R AND E/M WORKS TO ADV AIR FORCE HQ UNDER GE (FW) KOLKATA
2023_MES_619271_2
8174/E8
Open Tender
Civil Works
Item Rate
270 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹52,000
29 Nov 2023
6 Oct 2023
14 Oct 2023
6 Oct 2023
13 Oct 2023
6 Oct 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of Brick work / stone masonry built in cement mortar and removing the debris from MD land, complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4 sqm each and removing from the site complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and directed.
M&L for brick work with fly ash brick straight or curved on plan exc 6.0 mtr mean radius built in 1:6 cement mortar complete all as directed.
M&L for brick work with fly ash brick straight or curved on plan to any radius in half bricks thick walls, built in 1:4 cement mortar complete all as directed.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:4, using water proofing compounded, finished fair & even & smooth without using extra cement. complete all as specified and directed. (Note: WPC shall be measured and paid separately).
Supply only liquid water proofing compound of Make 2K, Pidilite or equivalent, all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:6, finished fair & even & smooth without using extra cement, all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work/ concrete on ceiling surfaces in CM 1:3, finished fair & even & smooth without using extra cement (up to ceiling height of 6 to 7 meters, including necessary scaffolding / arrangements for execution of work), complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 1 to 2 mm thick wall putty over plastered surfaces, finishing surfaces even and smooth and applying two coats of oil emulsion distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions, complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying two coats of oil emulsion distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions, complete all as specified and directed.
M&L for preparation of removed existing treated plastered surfaces of walls and applying 1-2mm thick wall putty over plastered surfaces, finishing surfaces even and smooth and applying two coats of oil emulsion distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions, complete all as specified and directed.
All as per item No.17.00 above, but on ceiling.
M&L for preparation of old decorated surfaces of walls (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) and applying two coats of oil emulsion distemper with roller complete all as specified and directed.
All as per item No.19.00 above, but on ceiling.
M&L for preparation of surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on new plastered surfaces complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces or un-plastered surfaces of wall and applying one coat of cement based paint with brush complete all as specified and directed .
M&L for preparation of old treated/painted surfaces of walls and soffit of chajjas, roof slab etc by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade / scrapper as applicable to make the surface free from loose paint, algae formation, dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5 mm with and including suitable elastomeric crackfill paste and applying one coat of weather proof exterior emulsion paint of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
All as per item No.24.00 above, but on steel surfaces
M&L preparing old decirated/treated brick, stone, concrete, asbestos cement surfaces or plastered surfaces of walls in any description and applying one coat of synthetic enamel paint complete all as directed.
M&L for 100mm thick cement concrete type B-2, 1:2:4, (using 40 mm graded aggregate) as in sub base for floor. complete all as specified and directed.
M&L non skid ceramic coloured digital tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles, laid over and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x 7mm / 450x 300 x 7 mm / 600x300x7mm thick as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
S&F Vitrified coloured (light shade) Ceramic tiles, 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 20mm thick in cement mortar 1:6 complete all as specified and directed.
All as per item No 30.00 here-in-before, but as in skirting on vertical surfaces, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed..
M&L 40mm thick cement concrete type B-1, 1:2:4, (using 20 mm graded aggregate) as in sub base for floor, finishing the surfaces of concrete (without using extra cement) even and rough to receive the top layer, complete all as specified and directed.
S&F 18-20 mm thick Granite slab, as in floors etc, machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing over and including 20mm screed bed in cement mortar (1:4) complete all as specified and directed.
S&F 18-20 mm thick Granite slab as in vertical surfaces machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing over and including 10mm rendering in cement mortar (1:3) complete all as specified and directed.
Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after laying of LT cable removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed. Note: Sand, if required for correction of cushioning level shall be measured and paid separately. Replacement of brocken paver blocks shall be separately as "Supply only"
Supply only Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
S&F steel water GI tubes "medium grade" with all fittings and fixed concealed to walls, ceilings or laid in floors complete with and including taking up or down of steel water tubing and connections complete all as specified and directed for the following sizes:-
15mm bore outer dia
20mm bore outer dia
25mm bore outer dia
40mm bore outer dia
50mm bore outer dia
M&L for cutting the existing GI pipe line of 50/40mm bore and refixing the suitable Tee 50x50x50/40x50x40mm bore, complete all as specified and directed.
S&F in repair chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed. (MAKE : JAQUAR, Cat No : ALD-573/ PARRYWARE, Cat No : T9941A1 / ESS ESS, Cat No: C-232D / CERA, Cat No: F8030301 / HINDWARE, Cat No: F160002)
S&F in repair vitreous china, white, counter top wash hand basin, including providing 32 mm dia chromium plated waste coupling and making all necessary connections complete all as specified and directed. (Make of Basin : Hindware, Cat No: 10038 / CERA, Cat No: S2030101 / Parryware, Cat No: C0431/Jaquar) (NOTE: Waste coupling and Waste pipe shall be measured and paid separately)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043)
S&F in repair Chromium plated brass Bib cock with wall flange (premium quality), fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: FUS-29037 / CERA, Cat No: F1015151/ ASIAN PAINTS, Cat No: ALBC101 / PRAYAG, Cat No: 9306-N/HINDWARE, CAT No: F360004 or equivalent model in PARRYWARE)
S&F fancy type chromium plated telephonic hand shower with flexible tube and hook screwed for iron pipe including frame complete all as specified and directed. (Make : PARRYWARE, Cat No: T9983A1/ Ess Ess, Cat No: HS 105) / PRAYAG, cat No: BHS-91S / CERA, Cat No: F7030502 / HINDWARE, Cat No: F160053 or equivalent model in JAQUAR)
S&F in repair 15mm dia fancy type chromium plated basin mixer foam flow screwed for iron pipe incl taking down old all as directed by Engr-in-Charge. (MAKE : ESS ESS, Cat No : C-211A / JAQUAR, Cat No : CON-167KNB / PARRYWARE, Cat No: G1414A1 / CERA, Model: OCEAN / PRAYAG, Cat No: 9250 / HINDWARE, Model: CONTESSA PLUS)
S&F in repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed. (Make : Ess Ess, Cat No: C-203 / JAQUAR, Cat No: CON-041KN/ PARRYWARE, Cat No: G1434A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP)
S&F in repair Chromium plated brass Towel ring (premium quality) complete all as specified and directed. (Make : Ess-Ess, Cat No: AC-502 / JAQUAR, Cat No: ACN-1121BN / PARRRYWARE, Cat No: T6002A1 / PRAYAG, Cat No: BA-11)
S&F in repairs toilet paper holder, surface type with flap incl taking down existing holder complete all as specified and directed. (Make : JAQUAR, Cat No : CAN-1153N / CERA, Cat No: F5007110 / PRAYAG, Cat No: BA-38 / ESS ESS, Cat No: AC-506 / HINDWARE, Cat No: F880003)
Supply & fix, as in repairs, brass chromium plated over head shower roses 125 mm size with or without swivel joint, including fixing to steel pipe or union all as specified and directed. (Make : CERA, Cat No: F7040103 (for arm) & F7020305 (for shower) / PARRYWARE, Cat No: T9802A1 (for arm) & T9986A1 (for shower)/ESS ESS, Cat No: OH-104A / HINDWARE, cat No: F160051)
S&F in repair Aluminium body ( extruded section ) door closer hydraulically regulated, designation No 3 , universal type suitable for door shutters of 851 to 1000 mmm in width and weight between 61 to 80 kg as directed by the Engr-in-Charge. (make : Godrej, Cat No. 1938 or equivalent as approved by Accepting Officer).
S&F in repairs, Tubular towel rail (premium quality), 20mm dia, 600 mm long between flanges including brass chromium plated, complete all as specified and directed. (MAKE : JAQUAR, Cat No : ACN-111SM / PARRYWARE, Cat No : T6401A1 / ESS ESS, Cat No: AC-101 / CERA, Cat No: F5004103 / PRAYAG, Cat No: BA-20 / HINDWARE, Cat No: F840013 )
S&F in repairs towel rack (premium quality) with lower hangar with hook incl taking down existing rack complete all as specified and directed. (Make : JAQUAR, Cat No: AHS-1581H / ESS ESS, Cat No: AC-308 / PARRYWARE, Cat No: T6008A1 / CERA, Cat No: F5003101 / PRAYAG, Cat No: BA-12)
S&F in repair vitreous china floor mounted coupled closet (Pedestal pattern) white including low level vitreous china valve less symphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittings including taking down existing water closet complete all as specified and directed. (Make : PARRYWARE, Model : Cascade NXT / CERA, Model : CLAIR / HINDWARE, Model: CONSTELLATION or equivalent model in JAQUAR)
S&F in repair White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Symphonic Action type with Inlet, Ball Valve, Float, flush pipe and Handle including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected items complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART or equivalent model in COMMANDER )
S&F in repair15mm bore heavy duty PVC connector pipe of length 450 mm with PTMT coupling at both ends, screwed down for pipe as directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON / CERA)
S&F in repair vitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including making good to floor, complete all as specified and directed. (MAKE : PARRYWARE, Cat No. C0117 / HINDWARE, Cat No. 20004 / JAQUAR, Cat No. CNS-WHT-OP01 / CERA, Model: COVY)
Supply and fixing chromium plated toilet tumbler holder in repairs (including with tumbler and chromium plated wall flange), fixing with stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. (Make : Jaguor cat No. CAN 1141 N or its equivalent in make. ESS-ESS / ESSCO)
S&F in repairs 15mm dia soap dish, square, acrylic body with chromium plated base complete all as specified and directed. (Make : Jaquar, Cat No : AKP-35731P / PARRYWARE, Cat No: T6403A1 / ESS ESS, Cat No: AC-103 / PRAYAG, Cat No: BA-35 or equivalent model in CERA /HINDWARE)
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long as in repair complete all as specified and as directed. Make : Ess Ess, Cat No AC207 or equivalent.
S&F in repair corner glass shelf 200 mm with brass brackets, as in repair complete all as specified and directed. (Make: PRAYAG, Cat No: BEA-44 / JAQUAR, Cat No: ACN-1173 / PARRYWARE, Cat No: T6010A1 / CERA, Cat No: F5005102)
S&F in repair CP bottle trap with internal portion 32mm size with 190mm long wall connection pipe complete all as specified and directed (Make: JAQUAR, Cat No: ALD-769L250x190 / ESS ESS, Cat No: C-231C / HINDWARE, Cat No: F850003 / CERA, Cat No: F8060302/ PRAYAG, Cat No: BEA-26)
Supply and fix in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON)
Cutting holes in brick walls in cement mortar for inserting holdfast or pipes and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick, etc complete all as specified and directed.
M&L mild steel bands and straps support or stays holdfast and similar articles conforming to Fe-290, Gde-165, complete all as specified and directed.
supply & fixing 35 mm thick 2nd class hard wood panelled shutters (any Nos of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers, fitted to chowkats complete all as specified and as directed by Engineer-in-charge.
S&F Aluminium door frame and operable shutter, windows and partitions and ventilators with one or more rebates including jointing cleat for fixing etc , complete all as specified and as directed.
S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (01 No) hinges type B-21 100 mm long (2 No) suitable handles etc. complete all as specified.
S & F Powder coated anodised aluminium window grills of size 100 x 100 mm having section width 6mm and 3mm thick fixed on aluminium section weighing not less than 0.55 kg / metre including necessary jointing fittings etc all as per manufacturers instruction complete all as specified .
Supply and fixing 4.8 mm thick sheet glass frosted on one side, area in squares exc 0.5 sqm in each pane and glazing with rubber gasket fixed to aluminium frame work / snap beading complete all as specified and as directed by the Engineer-in-Charge
S&F in stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as directed by Engr-in-Charge.
Supply & fixing 100mm mild steel butt hinges(medium weight) cold rolled complete all as directed by Engineer-in-charge.
S&F 600mm long Brass skeleton tower bolts of extruded section with cast brass plate and staples and rolled or drawn brass bolt and fixed complete all as specified and directed by Engr-in-Charge.
S&F 125mm long Extruded brass handles, fabricated type polished complete all as specified and directed by Engr-in-Charge.
S&F 250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and directed by Engr-in-Charge.
M & L in repairs 0.9mm thick decorative laminate type-1 (sunmica) of surface finish colour and pattern as approved fixed with approved adhesive as per manufacturer's instruction complete all as specified and directed by Engr-in-Charge.
S&Fin repairs 40mm dia cup board knobs, fancy type all as specified and directed by Engineer-in-Charge.
S&Fin repair Mild steel barrel tower bolts 75 mm long , stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair 12mm thick plywood grade BWR type B-B fixed with screws to timber frame works all as directed by the Engr-in-Charge.(Make : Greenply/Kitply/Alishan) or equivalent as approved by Accepting Officer
S&F in repair 19mm thick commercial faced plywood grade BWR type B-B fixed with screws to timber frame work as in pelmet boxes, cup board etcall as directed by the Engr-in-Charge.(Make : Greenply/Kitply/Alishan) or equivalent as approved by Accepting Officer
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap as in roof, wall fixed with L-type or J- type or cracked hook bolts in lieu screw complete all as directed by the Engr-in-Charge
S&F 125mm long Extruded brass handles, fabricated type polished complete all as specified and directed by Engr-in-Charge.
S&F 600mm long Brass skeleton tower bolts of extruded section with cast brass plate and staples and rolled or drawn brass bolt and fixed complete all as specified and directed by Engr-in-Charge.
S&F 250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and directed by Engr-in-Charge.
S&F Floor door stopper of brass body and tongue, anodised with hard drawn steel spring over all length of cover plate 140mm fixed in floor as in repair complete all as specified and as directed.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick in kitchen with plug washers, waste coupling, PVC waste pipe and fixing cantilever brackets connecting union to pipe, overall size of sink 914 mm x 460 mm and bowl size 405 mm x 354 mm x 203 mm complete all as specified and directed. (MAKE : CERA, Cat No: B4512201 /PRAYAG, Cat No. 1339D / PARRYWARE, Cat No: C855099 or equivalent model in NIRALI / ANJALI / JAYNA) (NOTE: Waste coupling and Waste pipe shall be measured and paid separately)
S&F in repairs continuous (piano) hinges mild steel bright finish width of flap 30mm when opened complete all as directed by the Engineer-in-Charge.
S&F in repairs 4 levers brass body, lock ,drawer graded 1 size 50 mm, complete all as directed by the Engineer-in-Charge.
S&F in repairs aluminium 'E' channel for sliding drawer shutter of cub board in two way 300 mm long complete all as directed by the Engineer-in-Charge.
S&F in repairs 100 mm double action spring hinges ( Hydraulic hinges) brass with phosphor bronze wire spring , bright polished complete all as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, steel window or stone concrete all as specified and directed by Engr-in-Charge.
S&F 3mm thick plain sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed by Engr-in-Charge.
S&F in repair Solar control film 25 micron reflective type (gareware sun control or equivalent)
S&F in repairs stainless steel wire cloth of 0.36 mm normal dia of wire and average width of apearture 1.40mm and fixed with stainless steel wire as directed by Engr-in-Charge.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
Supply and fixing Rolled mild steel in joist, channel, angle, or tee section fixed independently, upto a height of 6 metre from each floor level (cut to ordinary length i.e. within 20mm of the length indicated) of FE-410- W(Gde-E-250) quality-B including using iron props and steel plates to existing RCC overhead members like beams, slabs etc so as to ensure safety of existing structure and floor during repairing works complete all as specified and as directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as directed by Engineer - in - charge .
M&L for Providing Cement Concrete, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, of thickness as required on site, for making good depression/undulation, roof kerb etc, finished even and fair complete all as directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.20 litre per sqm over APP membrane.
Disconnecting existing water storage Tank of capacity exceeding 250 litres but not exceeding 500 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water tank and re-connecting and refixing all connections complete all as specified and directed.
Disconnecting existing water storage Tank of capacity exceeding 500 litres but not exceeding 1000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water tank and re-connecting and refixing all connections complete all as specified and directed.
Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole, for laying of UG Cable/poles/stays etc., not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed. Note: Quoted rate shall be deemed to include making good damaged road/hardstanding to match the existing specifications after laying cables / pipe lines as directed.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
Cutting of existing RCC hume pipe, any size and at any depth for construction of new manhole in existing line of size as per site requirement including repairing of edge of RCC hume pipe with cement mortar 1:1 and removal of cut portion of pipe from site complete all as specified and directed. (NOTE: Items for manhole & earthwork, excavation in hard surface/black top surface etc shall be measured and paid separately)
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 150 mm set in cement mortar complete all as specified and directed.
Supply and laying 150 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge.
M/L for PCC (1:3:6) type C2 using 40mm graded broken stone aggregates for bed concrete to drain pipe packing under haunching for sides for 150 mm dia pipe lines complete all as specified and as directed.
S &F as in repair cast iron Grade FG 150 grating, railing, frame manhole cover fire and stoot doors, dompers, stop valve box and similar articles etc (weight exc 3 Kg each ) including frame different size fixed in concrete cover as directed by Engr in Charge.
M & L cutting chases for concealed water tubing, pinning in, making good of facings where required and pointing in cement mortar 1:3 to ends or edges etc, cutting not exceeding 10 cm width or girth, complete.
M & L for PVC (SWR) multi floor trap with grating including jointing with solvent cement, dia of outlet 75 mm in repairs all as specified and directed by Engineer in Charge.
S&F in repairs 75mm bore PVC (SWR) waste pipes single socketed in any length with rubber ring joints laid in floors all as specified and directed by Engineer in Charge.
S&F in repairs 110mm bore PVC (SWR) soil pipes single socketed in any length with rubber ring joints laid in floors all as specified and directed by Engineer in Charge.
S&F in repairs 75mm bore PVC (SWR) waste pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed by Engineer in Charge.
S&F in repairs 110mm bore PVC (SWR) soil pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed by Engineer in Charge.
S&F in repairs 110mm bore PVC (SWR) junction single, (Single T) equal or unequal fixed to soil pipes all as specified and directed by Engineer in Charge.
S&F in repairs 75mm bore PVC (SWR) junction single, (Single T) equal or unequal fixed to waste pipes all as specified and directed by Engineer in Charge.
S&F in repairs 110mm bore PVC (SWR) bends any radius equal or unequal fixed to soil pipes all as specified and directed by Engineer in Charge.
S&F in repairs 75mm bore PVC (SWR) bends any radius equal or unequal fixed to waste pipes all as specified and directed by Engineer in Charge.
S&F in repairs 110mm bore PVC (SWR) vent cowl fixed to soil pipes all as specified and directed by Engineer in Charge.
S&F in repairs 75mm bore PVC (SWR) vent cowl fixed to waste pipes all as specified and directed by Engineer in Charge.
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
M&L cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate, 75 mm thick as in plinth protection, laid in alternate bays, finished even and smooth without using extra cement, complete all as specified and directed.
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 2000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
All as per item No.131.00 here-in-before, but 1000 Litre capacity
S&F in repairs 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms), complete all as specified and directed.
S&F in repair 25 mm bore gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repair 40 mm bore gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repair 50 mm bore gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc excluding light fitting for reuse or removing from site and making good disturbed surface of walls, floors etc. Complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No.138.00 above, but for one 5 Amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No.138.00 above, but for one 5 Amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No.138.00 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured separately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 142.00 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 142.00 here-in-before, but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 142.00 above, but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuity wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 16 Amp one way complete all as specified and directed.
S&F Bell push, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 and16 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete with all necessary electrical connection all as specified and directed.
S&F Stepped type ceiling fan regulator flush type, complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
S&F new Call bell, AC 230/240 Volts, Single Pole, all as directed.
S&F new Call bell, musical type, AC 230/240 Volts, Single Pole (as per sample as approved by GE), completed all as directed.
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6Amps, 1 module, complete all as specified and directed
S & F Modular Blank plate, 1 module complete all as specified and directed.
S&F Modular White cover plate with frame 2 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 1/2 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
All as per Item No.176.00 above, but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
Supply and Fix in repairs recess mounted LED luminaire suitable for 600 x 600 mm snap grid ceiling, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 30 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 6500 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Supply and Fix in repairs surface mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 6500 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
S&F in repair LED driver for 2'x2' LED ceiling light fitting 230 Volt 30 watt - 40 watt complete all as specified and as directed.
S&F in repair LED driver for LED strip light, 230 Volt 5 W complete all as specified and as directed.
NOTE FOR ITEM NO. 173.00 to 178.00 :- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete incl lamps from the date of completion of work. The product will be replaced free of cost in following cases :- (a) Manufacturing Defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 metre) below 90% of claimed value of lumen (or lux at 1 metre) of the LED/luminaire. (d) Decision of GE in this regard shall be final and binding. (3) All LED/luminaire shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/Section 13. (4) The contractor shall submit the LM-80 and LM-79 test report (except decorative fittings) as specified in Particular Specifications.
Repair/maintenance of ceiling fan of any sweep and any height by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed by Engr-in-Charge (Note: Capacitor of required capacity will be measured & paid under relevant item here-in-after)
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Repair/maintenance of exhaust fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Repair/maintenance of wall mounted fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed by the Engr-in-Charge.
Supply only capacitor (PVC body) of capacity 2.5 mfd
Supply only capacitor (PVC body) of capacity 3.15 mfd
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 190.00 above, but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 190.00 above, but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F MCB TPN DB 4 way double door, IP-43 protection, isolated natural bar, insulated busbar assembly 200 Amps, mechanical impact strength of IK08, complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB SPN DB 8 way double door, IP-43 protection, isolated natural bar, insulated busbar assembly 200 Amps, mechanical impact strength of IK08 complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB SPN DB 4 way double door, IP-43 protection, isolated natural bar, insulated busbar assembly 200 Amps, mechanical impact strength of IK08 complete all as specified and directed. complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCCB 160 Amps 25 KA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In complete all as specified and directed. complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
S&F in repairs PVC casing / capping of size 25 mm with all accessories all as directed by Engr-in- charge.
S&F in repairs PVC casing / capping of size 20 mm with all accessories all as directed by Engr-in- charge.
SCHEDULE 'A PART-III (EXTERNAL ELECTRIFICATION) Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
90 Sqmm to 120 Sqmm, 3.5 core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 2 Core
35 Sqmm, 3.5 Core
50 Sqmm, 3.5 Core
95 Sqmm, 3.5 Core
M&L for sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (NOTE: Punned thickness shall be measured for payment)
M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
M&L for replacement of pole mounted junction box 254x180x111mm having insulated and made out of thermoplastic pub carbonate with glass filter reinforced, rated for degree of in gross protection IP 66 in accordance with IEC60529, IK07, weather proof for outdoor installation (with knockouts for cable entry) having gasket matured shall be polyurethane and the gasket shall be internally embedded, tested at 6500 C with plastic mounting bracket, Din rail,, mild steel float, iron clamps, nuts, bolts and washes with MCB SP 6 Amp 'B' curve 10 KA complete all as specified and as disabled. (MAKE : CAPE ELECTRIC, Model No TKPS 2518-11MM or HENSEL, Cat No: KF 2525B or equivalent model.
S&F LED post top luminaire, 40 watt, with die cast aluminium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed. (Make : BAJAJ, Cat No: BGCT W4 LED WW / HALONIX, Cat No: HLPT-04-40-CW / SURYA, Cat No: SLE PT 40W-ETPP / Eveready, Cat No: LEDPOST045i3-01 / C&S, Cat No: CETUS-M/40W or equivalent model in other makes specified in particular specifications) NOTE: Wire for connection of luminaire shall be measured and paid separately.
S&F galvanised iron strip 32 mm X 6 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground, fixed on porcelain insulator @ 1.0 m spacing complete all as specified and directed. (Note: Porcelain insulators will be measured and paid separately)
S&F aluminium strip 25 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground, fixed on porcelain insulator @ 1.0 m spacing complete all as specified and directed. (Note: Porcelain insulators will be measured and paid separately)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Supply, installation, testing and commissioning of maintenance free Advance conductive based chemical earthing station using 17.2 mm dia, 3000 mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Underwriters Laboratories (UL) 467-2007 or latest, with 250 mm long copper strip of size 50 x 6 mm, exothermally welded on top of electrode complete including augering (boring) 100-125 mm dia hole as required for electrode in any type of soil and back filling with & incl carbon based ground enhancing compound (GEC) compound (with minimum qty 25 Kg per electrode) conforming to IEEE/BS standards complete all as specified and directed.
NOTE :- 1) The acceptable earth resistance at earth busbar/test point shall not be more than 01 Ohm. At certain locations, it may not be possible to achieve earth resistance of < 01 Ohm with one electrode/pit due to higher soil resistivity. In such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. The procedure mentioned below for one earth pit shall be repeated for other earth pits. Additional earth electrode pits and loop conductor shall be measured and paid separately under respective items. 2) The work shall be carried out by authorised trained rep of the OEM / Skilled person certified by GE.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of Power factor Improvement Static Condenser (Capacitor Banks) of capacity 35 KVAR indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.00 mm thick CRCA sheet of size 1000 mm x 900 mm x 500 mm, fabricated in CPRI approved factory with front and back operable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly powder coated over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 150 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle of size 50x50x6mm complete with legs not more than 450mm long including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
MCCB, 4 pole, 36 KA, Adjustable type, 100 Amps, Ics=100% of Icu, 415 Volts AC - 01 No
MCB, 10 kA, 'C' Curve, 3 Pole, 32 Amps - 01 No
MCB, 10 kA, 'C' Curve, 3 Pole, 20 Amps - 01 No
MCB, 10 kA, 'C' Curve, 3 Pole, 10 Amps - 03 Nos
MCB, 10 kA, 'C' Curve, Single Pole, 6 Amps - 03 Nos
Capacitor Heavy duty, Box type, 3 Phase, Capacity (15 KVAR x 1 +10 KVAR x 1 +2 KVAR x 2 + 1 KVAR x 1 & 10 KVARx1+5KVARx1)
Contactor 3 Phase, (MO C15-01 No, MO C10-01 No, MO C2-02Nos, MO C1 - 01 No, MO C10-01 No, MO C5-01 No)
APFC Relay 6 Stage with RS 485-01 No
CT's ratio 100/5A - 01 Set (Set of 03)
LED indicating lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
ON/OFF Indicating Lamp-06 Nos
Start/Stop Push Button - 06 Nos
PVC Exhaust Fan 230 Volts 50 Hz - 02 Nos
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of aluminium strip. (iii) All requisite accessories including spreader terminals shall be provided alongwith MCCBs and cost of the same shall be deemed to be inclusive in the quoted rates.
S&F in repairs LED Flood Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and toughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power factor not less than 0.95 (e) having in built short circuit and surge protection upto 5 kV (f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
70 Watt Flood Light Luminaire
100 Watt Flood Light Luminaire
S&F in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.95 (e) having in built short circuit and surge protection upto 5 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
35/36 Watt Street Light Luminaire
60 Watt Street Light Luminaire
SCHEDULE 'A' PART-IV (AIR CONDITIONING WORKS) Taking down for servicing of Split Type AC 1.5 TR Capacity, any make, including cleaning of cooling coil, air/plasma filters of indoor units and condenser, compressor, fan motor etc of outdoor unit with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits, relays, wiring kit, thermostat switches, knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. (NOTE: Replacement of parts, if required shall be measured and paid separately under respective items here-in-after)
All as per item No.219.00 above, but for 2.0 TR Split Type AC
Taking down for servicing of Window type AC 1.5 TR Capacity, any make including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and directed by Engineer-in-Charge. (NOTE: Replacement of parts, if required shall be measured and paid separately under respective items here-in-after)
All as per item No.221.00 above, but for 2.0 TR Window Type AC
S&F in repair starting relay for 1.5 TR compressor all as specified and directed.
S&F in repair starting relay for 2 TR compressor all as specified and directed.
S&F in repair Over load protector for compressor suitable for 1.5 TR compressor complete all as specified and directed
S&F in repair Over load protector for compressor suitable for 2.0 TR compressor complete all as specified and directed
S&F in repair thermostat switch for 1.5 TR split/window AC complete all as specified and directed.
S&F in repair thermostat switch for 2.0 TR split/window AC complete all as specified and directed.
S&F in repair Starting capacitor 80-100 Mfd capacity in metal container, all as specified and directed.
S&F in repair Starting capacitor 120-150 Mfd capacity in metal container, all as specified and directed.
S&F in repair running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 10 Mfd capacity in metal body pin type all as specified and directed.
S&F in repair running capacitor 6 Mfd capacity in metal body pin type all as specified and directed.
S&F in repair running capacitor 4 Mfd capacity in metal body pin type all as specified and directed.
S&F in repair running capacitor 2.5 Mfd capacity in metal body pin type all as specified and directed.
S&F in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 3/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 3/4'' dia complete all as specified and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and S&F new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
All as per item No.249.00 above, but for 2.0 TR Split Type AC
Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and S&F new blower motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and S&F new blower motor of AC as per OEM complete al;l a specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt condenser motor of 1.5 TR split AC (outdoor unit) and S&F new condenser motor of AC as per OEM incl replacement of bearing bushing etc complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt condenser motor of 2.0 TR split AC (outdoor unit) and S&F new condenser motor of AC as per OEM incl replacement of bearing bushing etc complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and S&F new swing motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue star/LG/Samsung)
Dismantling of burnt swing motor of 2.0 TR split AC (indoor unit) and S&F new swing motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue star/LG/Samsung)
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quantity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quantity complete all as specified and directed.
Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quantity complete all as specified and directed.
S&F in repair of suction valve size 1/2" complete all as specified and directed .
S&F in repair of discharge valve size 1/4" complete all as specified and directed.
S&F in repair of suction valve size 5/8" complete all as specified and directed .
S&F in repair of discharge valve size 3/8" complete all as specified and directed.
M&L for carrying out pressure leak test of Split Type ACs 1.5 capacity by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak, checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
All as per item No.264.00 above, but for 2.0 TR Split Type AC
M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
S&F in repair new PCB (printed circuit board) alongwith new cordless remote, visual eye demo plate and connected wiring of indoor unit of Split AC of capacity 1.5 TR complete all as specified and directed.
All as per item No.267.00 above, but for 2.0 TR capacity Split AC
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS-H) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipment's with terminal lugs / clips as per site requirement, complete all as specified and as directed.
Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable, drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 tonne reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc complete all as specified and directed. (Note :- Charging of gas refrigerant will be paid and measured separately
All as per Item No.272.00 here in before, but for 2.0 TR capacity reciprocating compressor
All as per item No.272.00 here in before, but 1.5 TR capacity rotary type compressor
All as per item No.272.00 here in before, but 2 TR capacity rotary compressor
S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed by the Engr-in-Charge. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ)
All as per item No.280.00 above, but for 2.0 TR capacity indoor unit
S&F in repair powder coated metallic stand (02 nos) for fixing outdoor units of Split Type Acs of 1.5/2.0 TR capacity complete all as specified and directed.
Taking down unserviceable blower motor base (2mm thick Mild Steel CRCA Sheet) of 1.5 TR/2TR capacity split AC and supply and fixing new blower motor base by welding / fixing by nut and bolt refixing the blower motor after completing the base and aligning the motor complete as directed by the Engr-in-Charge.
S&F Blower motor fan blade of existing make / model of window type Air Conditioner 1.5 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required in exc. Half Brick but not exc. one brick thick Walls and providing three coats white wash on finished surface complete all as specified and as directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer, cleaning and stacking bricks removing surplus serviceable bricks, hard-core and rubbish etc from site complete all as specified and as directed.
S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
S&F in repair power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed.
S&F in repair power contactor 3 pole, coil voltage 415 Volts of capacity 32 Amps Complete all as specified and as directed.
S&F in repair Timer Single Phase analogue type 230 Volts, Complete all as specified and as directed.
S&F in repair remote control hand set for 2.0 TR capacity split AC complete all as specified and as directed.
S&F in repair remote control hand set for 1.5 TR capacity split AC complete all as specified and as directed.
S&F in repair remote control hand set, suitable for 1.50 TR capacity window type AC complete all as specified and as directed.
M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit and descaling of condenser coil for Vertical type 3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed.
S&F in repair PCB kit complete for Vertical type Air Conditioner of any make and capacity complete all as specified and as directed.
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 2.50 TR by removing of old burnt compressor from outdoor unit and fixing as per manufacturer instruction complete all as specified and as directed. (Note :- Charging of Refrigerant gas will be measured and paid separately
Taking down unserviceable blower motor of existing make/model of Vertical type Air Conditioner 2.5/3.0/3.5/4.5 TR (Indoor) and refixing in proper position after rewinding and repair including providing all connections complete all as specified and directed.
Supply only PVC Flexible pipe 80mm dia complete with all fittings, complete all as specified and directed.
S&F PVC Cable trays with cover of size 75mm x 75mm on walls/Ceilings as per site requirement for proper fixing of Copper pipe with insulation alongwith fittings and fixtures arrangement, complete all as specified and directed.
GENERAL NOTES FOR SCH 'A' PART-IV :- (1) The works for repair of ACs and other connected refrigeration works shall be got carried out through experienced and qualified refrigeration mechanics. Necessary documents wrt qualification / experience shall be submitted by the contractor to Engineer-in-Charge before commencement of refrigeration works. (2) Defective spares for making the ACs, Refrigerators, Water Coolers, Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items. (3) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (4) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
KWALITY CONSTRUCTION
SRI BHOOMIJ INFRAPROJECTS & SERVICES LLP
M A ENTERPRISES
SK CONSTRUCTION SYNDICATE & ENGG CO
DEB AND COMPANY
ARATI TRADING CO
DGR CONSTRUCTION
SINHA ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .