Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC H NO 11 1 MATHRU NILAYA 7TH MAIN 3RD CROSS NEAR GAUTHAM COLLEGE OF PHARMACY BHUVANESWARINAGAR RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.0 L+₹24,318.04 (1.37%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹18.2 L+₹41,508.92 (2.33%)Rejected-AOC NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹19.1 L+₹1.3 L (7.20%)Rejected-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹19.2 L+₹1.4 L (7.89%)Rejected-AOC 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L5 | Rejected-AOC NOT LOWEST |
| Sl No | Description | Qty | Unit | VIKAS CONSTRUCTIONS L4 | Eeguchi Constructions L3 | S SUDHAKAR L1 | AMR CONSTRUCTIONS L2 | MAA ENGINEERING SERVICERS L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including roots after ensuring complete de-germification of palnt / weed and cutting down the plant/trees off from roof / top sides of external walls of buildings, on chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC (1:2:4) type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered in CM(1:4) including painting to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process for plants / trees located in the buildings with necessary scaffolding up to First floor, removing the material to a distance exc 500mm but not exc 1000m complete all as specified and directed.
NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge. | 70 | Per plant | 30 ₹2,100 Lowest | 70 ₹4,900 | 50 ₹3,500 | 30 ₹2,100 Lowest | 50 ₹3,500 |
| 2.00 | All as per Item No. 1 herein before but from first floor to second floor | 100 | Per plant | 35 ₹3,500 Lowest | 100 ₹10,000 | 60 ₹6,000 | 35 ₹3,500 Lowest | 50 ₹5,000 |
| 3.00 | All as per Item No 1 herein before but from second floor to third floor | 30 | Per plant | 40 ₹1,200 | 115 ₹3,450 | 70 ₹2,100 | 38 ₹1,140 Lowest | 50 ₹1,500 |
| 4.00 | Material and labour for cleaning of Roof at any height (on accessible / in-accessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus , leaves etc deposited over slab and making good the distrurbed surfaces if any with and including making good the surface using PCC (1:2:4) type B-1 or cement mortar (1:2) or brick work in CM(1:4) plastered in CM(1:4) to match with existing surface and removing the material to a distance exc 500mm but not exc 1000m complete all as specified and directed. | 3,000 | Sqm | 10 ₹30,000 | 12 ₹36,000 | 10 ₹30,000 | 10 ₹30,000 | 7 ₹21,000 Lowest |
| 5.00 | Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessible/in-accessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letter / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc 250ltrs but not exc 500 lit capacity all as specified and as directed. | 250 | Each | 250 ₹62,500 | 185 ₹46,250 | 150 ₹37,500 Lowest | 180 ₹45,000 | 350 ₹87,500 |
| 6.00 | All as per Item No 5 herein before but exc 500 litre & not exc 1000 ltr capacity | 80 | Each | 275 ₹22,000 | 235 ₹18,800 | 175 ₹14,000 Lowest | 280 ₹22,400 | 400 ₹32,000 |
| 7.00 | All as per Item No 5 herein before but exc 1000 litre & not exc 2000 ltr capacity | 5 | Each | 280 ₹1,400 | 300 ₹1,500 | 185 ₹925 Lowest | 320 ₹1,600 | 550 ₹2,750 |
| 8.00 | All as per Item No 5 herein before but exc 2000 litre & not exc 3000 ltr capacity | 10 | Each | 300 ₹3,000 | 350 ₹3,500 | 200 ₹2,000 Lowest | 330 ₹3,300 | 1,500 ₹15,000 |
| 9.00 | Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed. | 400 | Sqm | 30 ₹12,000 | 55 ₹22,000 | 10 ₹4,000 Lowest | 20 ₹8,000 | 20 ₹8,000 |
| 10.00 | M&L for Rendering 15mm thick cement mortar (1:6) on brick or concrete surfaces , finished even and smooth without using extra cement all as specified and as directed. | 140 | Sqm | 180 ₹25,200 | 250 ₹35,000 | 180 ₹25,200 | 130 ₹18,200 Lowest | 340 ₹47,600 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
10 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101 DICKENSON ROAD, BANGALORE-560042
CLEARING OF VEGETATION, CLEANING OF SERVICE TANKS AND PERIODICAL SERVICES AT OTM ACCN OF PRTC AND TA BN UNDER GE (NORTH) BANGALORE
2025_MES_740480_1
86501/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹58,000
13 Mar 2026
19 Nov 2025
17 Dec 2025
19 Nov 2025
10 Dec 2025
3 Dec 2025
19 Nov 2025 - 26 Nov 2025
Amount
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including roots after ensuring complete de-germification of palnt / weed and cutting down the plant/trees off from roof / top sides of external walls of buildings, on chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC (1:2:4) type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered in CM(1:4) including painting to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process for plants / trees located in the buildings with necessary scaffolding up to First floor, removing the material to a distance exc 500mm but not exc 1000m complete all as specified and directed. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
All as per Item No. 1 herein before but from first floor to second floor
All as per Item No 1 herein before but from second floor to third floor
Material and labour for cleaning of Roof at any height (on accessible / in-accessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus , leaves etc deposited over slab and making good the distrurbed surfaces if any with and including making good the surface using PCC (1:2:4) type B-1 or cement mortar (1:2) or brick work in CM(1:4) plastered in CM(1:4) to match with existing surface and removing the material to a distance exc 500mm but not exc 1000m complete all as specified and directed.
Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessible/in-accessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letter / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc 250ltrs but not exc 500 lit capacity all as specified and as directed.
All as per Item No 5 herein before but exc 500 litre & not exc 1000 ltr capacity
All as per Item No 5 herein before but exc 1000 litre & not exc 2000 ltr capacity
All as per Item No 5 herein before but exc 2000 litre & not exc 3000 ltr capacity
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed.
M&L for Rendering 15mm thick cement mortar (1:6) on brick or concrete surfaces , finished even and smooth without using extra cement all as specified and as directed.
M&L for Rendering 15 mm thick cement mortar (1:4) on other than fair faces of brick work or concrete surfaces, mixed with WPC, finished plastered surface even and smooth without using extra cement all as specified and as directed. Note :- WPC will be measured and paid separately
Supply only liquid water proofing compound, ISI marked, all as specified and as directed.
M&L for Rendering 5 mm thick cement mortar (1:3) on RCC ceiling surfaces , finished even and smooth with out using extra cement all as specified and as directed.
M & L for Preparation of newly plastered wall surfaces and applying two coats of Acrylic emulsion distemper over one coat of alkali resistant primer on 1mm thick wall care putty etc complete all specified and as directed.
M & L for Preparation of newly plastered wall surfaces and applying two coats of cement base paint over one coat of self primer etc complete all specified and as directed.
M & L for Complete removal of existing treatment on wall surfaces including chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc., including filling the minor cracks etc with crack filling material all as per manufacturers instructions and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of exterior weather proof primer complete all as specified and as directed.
M & L 4 mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for Sheet glass 4mm thick, ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane including Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for Preparation of new plastered ceiling surfaces including in narrow widths/ bands etc and applying three coats of white wash complete all specified and as directed.
M & L for Preparation of old decorated wall surfaces and applying one coat of white wash complete all specified and as directed.
M & L for Preparation of old decorated wall surfaces and applying two coats of white wash etc complete all specified and as directed.
M & L for Preparation of old decorated ceiling surfaces and applying one coat of white wash etc complete all specified and as directed.
M & L for Preparation of old painted/treated steel surface over 10cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed.
M & L for Preparation of old painted/treated wood and wood based surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
M & L for Preparation of old decorated/treated wall surfaces including washing, rubbing down and stopping and applying one coat of Acrylic emulsion distemper all as specified and directed.
M & L for Preparation of old decorated wall surfaces including washing, rubbing down and stopping and applying two coats of Acrylic emulsion distemper all as specified and directed.
M & L for Complete removal of existing treatment on walls including in narrow widths/ bands of any description and applying two coats of Acrylic emulsion distemper over one coat of alkali resistant primer on 1mm thick wall care putty finished to smooth surfacesetc complete all specified and as directed.
M & L for Preparation of old decorated ceiling surfaces including washing, rubbing down and stopping and applying one coat of acrylic emulsion distemper etc complete all as specified and directed.
M & L for Preparation of old treated wall surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying one coat of cement base paint etc complete all as specified and directed.
M & L for Preparation of old treated wall surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc and applying two coats of cement base paint etc complete all as specified and directed.
S & F in repair PVC (SWR) pipes 75 mm dia bore, single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed.
All as per item No 31 herein before but 110 mm dia bore.
S&F in repair PVC (SWR) Bends 75mm dia with access door of any radius all as specified and as directed.
All as per item No 33 above but 110mm dia bore
S&F in repair PVC (SWR) junction single(single T) equal or unequal 75mm dia with access door all as specified and as directed.
All as per item No 35 above but 110mm dia
S&F in repair 110mm dia PVC(SWR) brach piece, single(single Y) equal or un equal with access door all as specified and as directed
All as per item No 37 herein before but 75mm dia
S&F in repair 110mm dia PVC(SWR) brach piece,(double Y) equal or un equal with access door all as specified and as directed
All as per item No 39 herein before but 75mm dia
S&F in repair 75mm dia PVC(SWR) vent cowl all as specified and as directed
All as per item No 41 herein before but 110mm dia
Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile,Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirts etc over roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete all as specified and as directed Note : Rate includes for removing debris outside defence land distance exc 500m but n. exc 1000m
M & L for demolition & removal of cement concrete/padding concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed Note : Rate includes for removing debris outside defence land distance exc 500m but n. exc 1000m
M&L for Plain cement concrete (1:2:4) type B-0 using 12.50mm graded stone aggregate in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. directed
M & L for water proofing treatment over RCC roof slab with following specification all as specified & directed :- (i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Screed bed/rendering 10mm thick in CM (1:3) mixed with and including water proofing compound liquid as per manufacturers instructions. (iii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m (iv) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 75mm side overlap and 100mm end lap complete as per manufacturer's instructions (v) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m
Disconnecting existing tanks exc 250 & n exc 500 ltrs capacity, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified & directed. (Note : Cleaning repairing etc. measured separately)
Disconnecting existing tanks exc 500 & n exc 1000 ltrs capacity, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified & directed. (Note : Cleaning repairing etc. measured separately)
Supply & laying CPVC pipes 20 mm outer dia SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified & directed.
Supply & laying CPVC pipes 25 mm outer dia SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified & directed.
S&F in repairs CPVC gate valves, with lever , screwed both ends for iron pipe 20mm and fixed complete all as specified & directed.
S&F in repairs CPVC gate valves, with lever , screwed both ends for iron pipe 25mm and fixed complete all as specified & directed.
M & L for rotational moulded water storage tank 500 litres capacity, triple layered polythylene (cylindrical vertical with closed top) hoisting and fixed in position on roofs including PTMT ball valve 20 mm dia and fittings including dismantling existing water storage tank complete all as specified & directed.
M & L for rotational moulded water storage tank 1000 litres capacity, triple layered polythylene (cylindrical vertical with closed top) hoisting and fixed in position on roofs including PTMT ball valve 25 mm dia and fittings including dismantling existing water storage tank complete all as specified & directed.
S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20mm dia bore and fixed all as specified & directed..(Minimum weight 2 0 m m - 2 1 0 g m s)
S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 25mm dia bore and fixed all as specified & directed.(Minimum weight 25mm-455gms) all as specified and as directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint with thick paint, so that they stand out boldly and solidly without showing signs of brush marks, if necessary, they shall be repainted until the desired result is obtained all as specified & directed.
S & F in repair cover suitable for PVC water tank 500/1000 litre capacity all as specified & directed.
AMR CONSTRUCTIONS (BID ID -3494378)
Eeguchi Constructions (BID ID -3491544)
VIKAS CONSTRUCTIONS (BID ID -3490672)
MAA ENGINEERING SERVICERS (BID ID -3500121)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_829155.xls
BOQ • 1.85 MB
tender86501.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .