| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC 156 INDIRA COMMERCIAL COMPLEX TRANSPORT NAGAR KORBA CHHATTISGARH 495677 | KORBA | CHHATTISGARH | 495677 | ₹4.4 Cr | L1 | Accepted-AOC the quoted rate of L-1 bidder is reasonable and acceptable |
| 2 | Rejected-Technical NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | - | - | Rejected-Technical THE BIDDER IS TECHNICALLY REJECTED DUE TO NON COMPLIANCE OF WORKING CAPITAL CRITERIA AS PER NIT |
Tender Value
₹4.2 Cr
EMD Value
₹5.2 L
Closing Date
27 Jul 2024, 5:00 pmClosed
GM EnM HOD Div I
1st Floor EnM Department Alakhnanda Building CCL HQ Darbhanga House Ranchi Pin - 834001
Planning, Design, Engineering, Construction, Fabrication, Supply, Erection, Installation, Testing, Trial Run and Commissioning of Renovation of Surface Belt Conveyor Consisting of all Electrical. Civil, Structural at CHURI UG NK AREA
2024_CCL_311650_1
GM(ENM)/E-TENDER/24/845 DATED 01.07.2024
Open Tender
Miscellaneous Works
Item Rate
180 days
CHURI UGP NK AREA CCL
Refer Tender Documents
7 documents required · 7 mandatory
₹5.2 L
14 Nov 2024
2 Jul 2024
29 Jul 2024
2 Jul 2024
27 Jul 2024
3 Jul 2024
3 Jul 2024 - 16 Jul 2024
Amount
A. WORK & SERVICES
Detailed survey of the area within the battery limit & submission of reports
Sub soil exploration, field and laboratory testing of samples and submission of reports.
Design Engineering Cost
Preparation and submission of system engineering drawings
G.A. & detailed engineering designs and drawings of all civil and structurals included in system & Scope of works
G.A. & detailed engineering designs and drawings including working and maintenance manuals of : i) all individual equipment ( Mechanical & Electricals) ii) Dust Control & Pressurisation system. iii) Fire-fighting system. iv) Chutes & Liners v) Communication system vi) Illumination system. vii) Plant control system
Documentation as per tender specification, complete as per scope of works
B. CIVIL, STRUCTURAL, INFRASTRUCTURAL AND DEVELOPMENT WORK
Conveyor Gantry/Gallery with supporting structures
Strengthening of CHP Bunker / Truck Hopper (5x125Te)
Pump house
Electrical Switch Room Building
Dismantling Cost
C. PLANT & MACHINERY ( SUPPLY)
C.(a) SUPPLY : MECHANICAL
Replacement of Surface Main belt conveyor & Shuttle belt conveyor/Trolley belt conveyor as mentioned in "Scope of Supply"
Belting for Surface main Belt Conveyor & Shuttle Belt Conveyor/Trolley Blet Conveyor, as per "Scope of Supply".
EQUIPMEMT
Cross Belt Magnetic Separator in Surface Main Belt conveyor
Metal Detector in Surface Main Belt conveyor
3 T Electric Hoist at discharge end and 2T Electric Hoist at tail end of Surface Main belt conveyor.
1 T Manual Hoist/ chain pulley block above shuttle / Trolley conveyor
Safety & Fire Fighting (Hydrant, MVWS,sprinkler, Portable Type & detection system)
Dust Suppression system,Service water system,potable water system & service air
Sump pump
Replacement of Miscellaneous items such as chute liners, chute block switch etc.
C.(b) SUPPLY : ELECTRICAL
415 V sectionalized Motor Control Centre comprising 1 no. of Incomer ACB,1 no of outgoing ACB for capacitor bank, and 7 nos. of outgoing Feeders for supply of powerto Conveyor motor and trolley conveyor, Electrical Hoist, Dust Suppression/ Extraction, Fire-fighting system, etc . and 1 number outgoing ACB as spare-1No
415 V Capacitor Bank of required capacity with APFC panel for improvement of Power Factor complete set-1No
1.1kV grade, XLPE, double wire armoured copper conductor FRLS cables of different sizes as per requirement
1100 V grade, XLPE insulated, PVC sheathed, single wire armoured, Copper conductor, FRLS cables of different sizes as per requirement
1100 V grade, single/multi core XLPE insulated, PVC sheathed, Copper conductor, FRLS, control and signaling cables of 2.5 sq. mm cross-section having different no. of cores as per requirement.
Cable trays/cable racks (separate trays shall be used for power and control cables), cable trenches & cable vaults etc. as per technical specification
110V Lead Acid Battery , 120 AH complete with Battery Charging unit and racks-1No
415/110V control transformer for AC control supply -1No
Galvanized earthing strips / wires / conductors for main earthing grid, sub earthing grid of buildings and structures, earthing of light fittings, welding sockets, pull chord switches, belt sway switches, zero speed switches and various electrical equipment, Ground electrodes and earthing pits with chemical compound as per technical specification
Equipment and accessories for Lightning protection system for building and structures having height of 10m and above with separate earth pits
Portble CO2 type Fire extinguishers(4.5kG)
C1. ERECTION, INSTALLATION & COMMISSIONING
Erection of mechanical equipment
Erection of electrical equipment
Erection of other plant and machining etc.
Trial run, and commissioning of the plant
C2 . OTHERS ITEM
Any other item left out for completion of the project
C3 . MAINTENANCE AND TRAINING
Training of the employer personnel as per tender document
Total impact of GST for the purpose of CTC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .