Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.4 L+₹30,560 (3.38%)Rejected-AOC | L2 | Rejected-AOC Other Than Lowest | |
| 3 | L3₹9.4 L+₹34,340 (3.79%)Rejected-AOC | L3 | Rejected-AOC Other Than Lowest | |
| 4 | L4₹9.9 L+₹84,540 (9.34%)Rejected-AOC | L4 | Rejected-AOC Other Than Lowest | |
| 5 | L5₹10.7 L+₹1.7 L (18.4%)Rejected-AOC | L5 | Rejected-AOC Other Than Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Oct 2020, 6:00 pmClosed
GE (N) Mamun
GE (N) Mamun C/O 56 APO
Repair/Replacement Of Ceiling Fan, Exhaust Fans, Wall Mounted Fans, Geyser, Electric Energy Meter And Connected Works At Different Locations Under Age E/M-I Of GE(N)
2020_MES_373866_1
GE(N)/M- /2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (N) Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) Mamun
₹30,000
Yes
6 Nov 2020
1 Sept 2020
7 Oct 2020
1 Sept 2020
5 Oct 2020
16 Sept 2020
Amount
Taking down carefully Ceiling fan /Wall Mounted fan/ Exhaust fan of any rating / capacity from site (as directed by JE/Engr-in-Charge) and after repairing complete again refixing in same position complete. (Note-: Spares parts will be measured and paid separately under respective items).
Dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm/1400mm sweep any make with super enameled colour copper winding wire of gauge 35SWG and weight not less than 200gms and not more than 350 gms including, sleeve work, varnishing with F class insulation paper with threading, including blade screws of suitable size and ensuring all blades screwed properly before refixing or issuing to concerned unit complete all as specified and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used. (ii) Motor shall be wound with machine only. (iii) Super enameled copper winding wire shall only be used. Make of copper winding wire: BIC, HTP or DEVIDYAL
All as per Srl item No 02 above but weight more than 350 gms but less than 500 gms complete all as specified and directed.
All as per Srl item No 02above but weight above 500 gms complete all as specified and directed.
S&F in Replacement of old unserviceable gun metal bush of ceiling fan of size 1200/1400mm sweep as per existing size complete all as specified and directed.
Dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of AC wall mounted fan motor 400mm/600mm sweep with super enameled colour copper winding wire of gauge 35SWG and weight not less than 250gms including, sleeve work, varnishing with F class insulation paper with threading, including blade screws of suitable size and ensuring all blades screwed properly before issuing to concern unit complete all as specified and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used. (ii) Motor shall be wound with machine only. (iii) Super enameled copper winding wire shall only be used. Make of copper winding wire: BIC, HTP or DEVIDYAL
S&F in Replacement of old unserviceable capacitor AC 440 volts 2.5 mfd with copper wire terminal complete all as specified. Make:Havells/Epcos/Matrix
S&F in Replacement of old unserviceable capacitor AC 440 volts 3.15 mfd with copper wire terminal complete all as specified. Make:Havells/Epcos/Matrix
S&F in Replacement of old unserviceable capacitor AC 440 volts 4.0 mfd with copper wire terminal complete all as specified. Make:Havells/Epcos/Matrix
S&F in Replacement of old unserviceable ball bearing of size 6201 & 6202. Make:- SKF or NBC or any other equivalent make.
S&F in Replacement of old unserviceable ball bearing of size 6203. Make:- SKF or NBC or any other equivalent make.
S&F in Replacement of old unserviceable ball bearing of size 608/629. Make:- SKF or NBC or any other equivalent make.
S&F in Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp -02 Nos, nut ,check nut,spring washer, bolt not less tha 6.0mm dia & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
S&F in Replacement of old unserviceable ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.5mm suitable for 1200mm sweep ceiling fan complete all as specified & directed .
All as per Srl Item No 14 above but suitable for ceiling fan 1400mm sweep ceiling fan of any make complete all as specified and directed .
S&F in Replacement of old unserviceable ceiling fan down rod of length 30cm made of MS tubing 15mm dia heavy duty complete with split pin, hanging clamp and rubber real, complete all as specified.
S&F in Replacement of old unserviceable ceiling fan down rod of length 45cm made of MS tubing 15mm dia heavy duty complete with split pin, hanging clamp and rubber real, complete all as specified.
S&F in Replacement of old unserviceable ceiling fan down rod of length 60cm made of MS tubing 15mm dia heavy duty complete with split pin, hanging clamp and rubber real, complete all as specified.
S&F in Replacement of old unserviceable ceiling fan down rod of length 90cm made of MS tubing 15mm dia heavy duty complete with split pin, hanging clamp and rubber real, complete all as specified.
Supply and fix in replacement ceiling fan canopy of suitable size complete all as specified and directed.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing and making electrical connections complete all as directed. (Unserviceable parts other than specified in this item if any will be measured seperately).
Supply and Fix cable FRLS PVC insulated and overall sheathed with flexible copper conductor 3 core of size 0.50 Sqmm cut to size all as required at site for connection from ceiling rose to connector block of ceiling fan.
Servicing of Exhaust fans of capacity 450/350/300/250mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing and making the electrical connections complete all as directed . (Unserviceable parts other than specified in this item if any will be measured seperately).
Dismantling and Re-winding of exhaust fan motor 250-300mm sweep with super enameled copper winding wire of gauge 35SWG and weight not less than 250gms including cutting and getting out old brunt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexbile wire of size 23/0.0076mm of length not more than one mtr with each fan complete all as specified and directed. (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used. (ii) Motor shall be wound with machine only. (iii) Super enameled copper winding wire shall only be used. (iv) Copper winding weight shall not be less than old existing repaired fan. Make of Copper winding wire: Devidayal, BIC, HTP
All as per Srl item No 24 above but above 300mm and upto 450mm sweep and weight upto 500 gms complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filler and applying two coats of super enamelled synthetic paint to complete ceiling fan of size 1200/1400mm sweep at site incl, writing CA No, MES No or Srl No & location on the ceiling fans as directed or required at site.
Removing old paint by scraping with sand paper including washing and filling cavaties with filler and applying two coats of super enamelled synthetic paint to complete exhaust fan of size any size upto 450mm sweep at site incl, writing CA No, MES No or srl No & location on the ceiling fans as directed or required at site.
S&F in Replacement of old unserviceable fan blades made of MS sheet duly powder coated, of type make and colour as of existing exhaust fan suitable for fans up to 300mm sweep any make complete all as specified.
Supply and fix in replacement screws of suitable size for fixing ceiling fan blade complete all specified and directed.
Supply and fix in replacement of old unserviceable exhaust fan blades made of MS sheet duly powder coated, of type make and colour as of existing exhaust fan suitable for fans above 300mm and upto 450mm sweep any make complete all as specified and directed.
Taking down carefully geyser 35 to 50 ltrs capacity from wall after unscrewing nuts/bolts etc and again refixing in position after repair & replacement of spare-parts, descaling of rust and rubbish material from the inner tank testing complete after replacing the unserviceable spare parts all as specified and directed. Note:- 1.Spare parts/ items required will be measured and paid separately under respective items.
All as per Srl Item No 31above but capacity upto 25 ltrs.
Supply & Fix in replacement of thermostat ISI marked suitable for geysers upto 50 Ltrs Capacity any make or type as per site requirement. The adjustable range shall be 0 - 75 degree celsius complete all as specified and directed.
Supply & Fix in replacement of fusible plug made of brass with fusible lead suitable for geyser of capacity upto 50 ltrs complete all as specified and directed.
Supply & Fix in replacement of spring loaded air release valve ISI marked suitable for geysers upto 50 ltrs capacity complete all as specified and directed.
Supply & Fix in replacement of safety valve dead wt. type ISI marked suitable for of capacity upto 50 Ltrs complete all as specified and directed.
Supply & Fix in replacement of old unserviceable 6 Hole syphon assembly made out of Stainless steel suitable for 25/50 ltrs capacity geyser including necessary studs, screws and rubber gasket/washers complete all as specified and directed.
Supply & Fix in replacement of old unserviceable 9 Hole syphon assembly made out of Stainless steel suitable for 25/50 ltrs capacity geyser including necessary studs, screws and rubber gasket/washers complete all as specified and directed.
Supply & Fix in replacement of heating element titanium coated ISI Marked of 1.5 KW rating round or triangular suitable for water heater storage as required at site including rubber washers complete all as specified and directed.
Supply & Fix in replacement of heating element titanium coated ISI Marked of 2.0 KW rating suitable for water heater storage as required at site including rubber washers complete all as specified and directed.
Supply & Fix in replacement of old unserviceable stainless steel Internal tank for vertically mounted geyser 25 Ltr capacity complete all as specified and directed. Notes: (i) The tank shall be tested at site and shall be able to withstand requisite pressure.
All as per Srl item No. 41 above but 50 Ltr capacity complete all as specified make and approved.
Supply & Fix in replacement of old unserviceable stainless steel Internal tank with inbuilt assembly for vertically mounted geyser 50 Ltr capacity of make Crompton Radiant/Racold complete all as specified and directed. Notes: (i) The tank shall be tested at site and shall be able to with stand requisite pressure.
Supply & Fix in replacement of old unserviceable stainless steel braided flexible connection pipe with brass hexagonal adopters/nuts on both sides, 15mm bore (300mm long) complete ISI marked, suitable for cold & hot water upto 0-80 degree celcius complete all as specified and directed make as approved.
Supply & Fix in replacement of old unserviceable stainless steel braided flexible connection pipe with brass hexagonal adopters/nuts on both sides, 15mm bore (450mm long) complete ISI marked, suitable for cold & hot water upto 0-80 degree celcius complete all as specified and directed make as approved.
Supply & Fix in replacement of non return valve 15mm dia of brass ISI Marked all as specified and directed make as approved.
Supply & Fix in replacement of old unserviceable thermal insulation material non hygroscopic, fire resistant fiber glass wool for 25-50 ltrs capacity geyser complete all as specified and directed make as approved.
S & F in replacement Outer container made out of 14 guage CRCA sheet duly painted for water heater storage type of capacity 25 ltrs incl bottom cover complete all as specified and directed make as approved.
All as per Srl Item No 48 above but for 50 ltrs cap.
Supply & Fix in replacement of neon indicator lamp as persite requirement for geyser of cap upto 50 Ltrs any make and type.
Supply & Fix in replacement PVC insulated and PVC sheathed cable 3 core 2.5 Sq.mm flexible stranded all as specified and directed.
Supply & Fix in replacement 3 Pin Plug Top 16Amps stranded all as specified and directed.
Supply and Fix in Replacement of MCB SP 20 Amps.
Supply and Fix in Replacement of Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S & F stepped type electronic fan regulator Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type.
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as spd and directed.
Fixing only of sheet metal enclosure with plug socket and MCB 20A SP and making connection with sub main wire with suitable size of thimbles including Cutting chases of suitable size on existing wall and making connection to the submain wire and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface including testing on connected load complete all as specified and directed. Note: 1. Sheet metal enclosure with plug socket will be issued under Schedule 'B' free for fixing 2. Rate of MCB SP 20Amp, 10kA is deemed to be included in the quoted rate.
Fixing only Single Phase/three Phase Electronic energy meter by drilling on wall and fixing meter by means of suitable size of screw and making connection to existing MCBs in DB Box including flexible PVC pipe of suitable size and testing complete incl taking down old unsv meters and deposting in MES store yard all as specified and directed. Note: 1. 1Phase/3 Phase Electronic energy meter to be issued under Sch 'B' free for fixing.
Supply and fixing carbon steel anchor bolts, nut and washer of size 12mm dia & 80mm length by grouting in wall complete for mounting Geyser of any size all as specified and directed
S & F of angle valve/cock with flange chromium plated suitable for 15 mm dia GI Pipe complete connection all as directed.
M&L for fixing Ventillating fan of sweep 250mm sweep incl cutting hole or square section of suitable size on existing wall fixing ventillating fan with suitable size of nuts bolts, connecting with 3core flexible copper conductor of 0.50 sq mm and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed .
Supply and fix in replacement Exhaust fan louver round or rectangular shaped made of MS steel sheet for exhaust fan of size 250mm to 300mm sweep and fixing on wall by means of suitable size of screws incl taking down old unsv louvers complete all as specified and directed.
Supply and fix in replacement Exhaust fan louver round or rectangular shaped made of MS steel sheet for exhaust fan of size 380 to 450mm sweep and fixing on wall by means of suitable size of screws incl taking down old unsv louvers complete all as specified and directed.
Supply and fixing in replacement 2Pole 20Amps metal clad plug top complete all as specified.
v k engineers and builders
M/S NILESH ENTERPRISES
KULBHUSHAN AGGARWAL
Paramjit Singh and Co
vivek and co
Vijay Kumar Contractor and Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .