| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 126 NARANG COLONY JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | ₹2.6 Cr | L1 | Accepted-AOC Being lowest and reasonable tender |
| 2 | L2₹2.9 Cr+₹24.4 L (9.23%)Rejected-Finance | ₹2.9 Cr+₹24.4 L (9.23%) | L2 | Rejected-Finance Being L2 bidder |
| 3 | L3₹2.9 Cr+₹24.8 L (9.36%)Rejected-Finance | ₹2.9 Cr+₹24.8 L (9.36%) | L3 | Rejected-Finance Being L3 bidder |
| 4 | L4₹3.3 Cr+₹68.1 L (25.8%)Rejected-Finance | ₹3.3 Cr+₹68.1 L (25.8%) | L4 | Rejected-Finance Being L4 bidder |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
26 Sept 2022, 6:00 pmClosed
CWE AF PALAM
CWE(AF) PALAM DELHI CANTT-10
ADDN/ALTN OF SMQs (PHASE-II) AT HQ WAC (U) UNDER GE(AF) SUBROTO PARK DELHI CANTT-10
2022_MES_543384_1
CWE/PM/SP-18/2022-23
Open Tender
Civil Works
Item Rate
450 days
GE AF SUBROTO PARK
As per tender documents
10 documents required · 10 mandatory
₹2,000
GE AF SUBROTO PARK
₹3.9 L
17 Nov 2022
4 Aug 2022
30 Sept 2022
4 Aug 2022
26 Sept 2022
12 Sept 2022
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Demolition of cement concrete (unreinforced) in ground floor and paving n. exc. 15 cm thickness( below or above ground level) complete all as specified and as directed
M&L for PCC (1:5:10) type E-2 using 40 mm graded aggregate as in sunken portion complete all as specified and as directed
Cleaning the sunken floor surfaces by wire brushes, brooming, removing dust by dismantling of floor, lime terracing complete all as specified and as directed and applying following :- (a) 10mm thick screed bed in cement mortar 1:3 complete mixed with water proofing compound as per manufacturer instructions complete all as specified and directed. (b) Bitumen primer confirming to IS-3384-1986 (Reaffirmed 2010) @ 0.50Kg Per Sqm. (c) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm confirming IS-702-1988 (latest amended) for water proofing membrane. (d) Applying of polymeric water proofing membrane, weight not less than 3 Kg/Sqm over entire area with overlaps and sealed all as specified directed . (e) Again applying a tack coat of hot blown bitumen 85/25 @ 1.2Kg/Sqm over water proofing membrane. (f) Dusting dry sand @ 0.75 Kg Per Sqm over water proofing membrane.
Supply only integral water proofing compound complete all as specified and as directed.
S&F in repair 32 mm dia galvanised iron spout light grade for sunken portion including cutting and making good the wall/surface complete all as specified and as directed.
S&F in repair vitreous china squatting pan ORISSA pattern size of 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe etc including making good to floor complete all as specified and as directed.
Taking down cement or cement lime plaster etc. on brick wall or stone walls etc including raking out joints, hacking for key, scrubbing down with water, etc and disposing off unserviceable materials to outside MOD land complete all as specified and as directed.
M&L 10 mm thick cement mortar 1:6, on fair faces of brick work or concrete surfaces on wall surface even and smooth without using any extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling, complete all as specified and as directed
M&L 15 mm thick cement mortar 1:4 on other than fair faces of brick work or concrete surfaces on wall surface even and smooth without using any extra cement complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
M&L 25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base of floor etc.complete all as specified and as directed
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but n. exc 0.11 sqm, in floors or dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
M&L Non skid ceramic coloured tiles 10 mm thick (square/rectangular) area of each tiles exc 0.18 sqm but n. exc 0.38sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
M&L Glazed coloured ceramic tiles in vertical surface/ dado 450 mm X 300mm X 7 mm to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L 15 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of marble stone complete all as specified and as directed.
M&L Green marble 18-20 mm thick machine cut , bedded jointed and pointed with grey cement slurry including cutting and polishing complete all as specified and as directed.
S&F in repair kitchen sinks with drainage board made of stainless steel 1 mm thick with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410mm x 330 mm x 160mm complete all as specified and as directed
Taking down door chowkhats or frames with shutters, any type (without taking off shutters from the frame) area not exceeding 1.50 sqm complete all as specified and as directed
Taking down door chowkhats or frames with shutters, any type (without taking off shutters from the frame) area exceeding 1.5 sqm but n.exc 4.0 sqm ) complete all as specified and as directed
Taking down shutters of any description exc 1 sqm but n.exc 2.0 sqm each including removing to store complete all as specified and as directed
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., of size 105 x 60mm including frame back filling with PCC 1:3:6 with 12.5 mm aggregate complete all as specified and as directed.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., of size 165 x 60mm including frame back filling with PCC 1:3:6 with 12.5 mm aggregate complete all as specified and as directed.
S&F 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 2nd class Hard wood glazed and skeleton 35mm thick shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze etc complete all as specified and as directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor ,150 mm overall length of cover plate complete all as specified and as directed
M&L for 18/19 mm thick pre-laminated particle board interior grade pre-laminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to angle frame work for cupboard shutter and shelves including taking down old one complete all as specified and as directed .
M&L for 18/19 mm thick pre-laminated particle board interior grade both sides balancing white lamination fixed with screw to angle frame work for cupboard shutter and shelves including taking down old one complete all as specified and as directed .
M&L for external teak wood lipping 12 mm thick fixed with nails on external edges of pre-laminated particle boards complete all as specified and directed
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanised of width of flap (when open) 30mm complete all as specified and as directed
M &L for 125 mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and as directed .
S&F for 125 mm size of hasp & staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed at site
S&F for galvanised rigid steel conduit 20 mm external dia pipe for hanger rods in repairs including necessary arrangement to fixed in cup board complete all as specified and directed at site
Supply and fixing in repair windows/ ventilators fabricated from 0.60 mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for dual shutter i.e. inner and outer shutter with grill, glazed and wire mess shutter and all fitting, fixtures accessories including 6mmx12mm flat iron with 10mm square bar M.S. grills complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(4000 series) with latest revision NOTE: (i) Glazed shutter with 4.00 mm thick glass, mesh shutter with 32 gauge stainless mesh and MS grill as per srl no 10,11 and 13 of notes of above mentioned drawing is deemed to be inclusive in the rate quoted for unit (ii) Glass, stainless steel mesh will be fixed to window by authorised representative of manufacturer of window only. (iii) Rate including taking down of any type of windows frame with shutter & guard bar etc. and making good the surface are deemed to be included in quoted rate.
Supply and fixing in repair windows/ ventilators fabricated from 0.60 mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for single shutter with grill, glazed shutter and all fitting, fixtures accessories incl 6mmx12mm flat iron with 10mm square bar M.S. grills complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(3000 series) with latest revision NOTE: (i) Glazed shutter with 4.00 mm thick frosted/plain glass, mesh shutter with 32 gauge stainless mesh and MS grill as per srl no 10,11 and 13 of notes of above mentioned drawing is deemed to be inclusive in the rate quoted for unit (ii) Glass, stainless steel mesh will be fixed to window/ventilator by authorised rep of manufacturer of window/ventilator only. (iii) Rate including taking down of any type of windows frame with shutter & guard bar etc. and making good the surface are deemed to be included in quoted rate.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with SS wire staples complete all as specified and as directed ..
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube complete as per manufacturer’s specification & drawing complete all as specified and as directed
S & F Factory Made Solid PVC Moulded Door shutter, 28 to 30 mm thick (Stiles) ,with 2,4 or 6 raised panels design with 2 mm thick Moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification complete all as specified and as directed.
S & F Butt hinges,medium weight, cold rolled mild steel of size 100mm complete all as specified and as directed .
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F 200 mm length aluminium anodized, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size aluminium handle, cast type anodized complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 15 mm bore steel tubing galvanized medium grade with all fittings and fixed concealed to walls and ceiling or laid in floors complete all as specified and as directed.
S&F 20 mm bore steel tubing galvanized medium grade with all fittings and fixed concealed to walls and ceiling or laid in floors complete all as specified and as directed.
S&F in repair brass chromium plated shower rose 125 mm size with swivel joints including fixing to pipe complete all as directed
S&F in repair 15 mm dia bib taps, cast copper alloy chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F 15 mm dia stop valves cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, concealed type, screwed both ends for iron pipe or for union and fixed complete all as specified and as directed.
S&F CP grating in repairs round 100mm dia complete all as specified and as directed.
S&F in repair PVC flushing cistern, valveless, syphonic action type, 10 Ltr capacity, low level, white, with inlet, ball valve, float and handle including bracket complete all as specified and as directed.
S&F PVC connection of 45 cm long with 2 Nos PTMT side nuts screwed with iron pipe of 15 mm dia complete all as specified and as directed.
S&F stainless steel soap dish, any type, fixed to plugs with chromium plated brass screws embedded in wall complete all as specified and as directed.
S&F in repair vitreous china WHB white, flat back, size 550 x 400mm including brackets ,coupling and all accessories etc complete all as specified and as directed
S&F C.P tubular Towel rail 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S&F in repair pillar taps cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed 15mm bore dia complete all as specified and as directed .
S & F 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed
S&F in repairs 32mm bore and 75cm long PVC flexible waste pipe for WHB complete all as specified and as directed
Dismantling of CI pipe including all fittings from wall/trenches of any type & any size complete all as specified and as directed
S & F for 75 mm dia cast iron soil/waste pipe in any length with or without ears with cement joints laid in trenches or in floors etc including dismantling complete all as specified and directed
S & F for 100 mm dia cast iron soil/waste pipe in any length with or without ears with cement joints laid in trenches or in floors etc including dismantling complete all as specified and directed.
S&F in repair bends any radius for 100 mm bore CI pipe with cement joints complete all as specified and as directed.
S&F in repair bends any radius for 75 mm bore CI pipe with cement joints complete all as specified and as directed.
S&F in repair Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed.
S&F in repair CI vent cowl 75 mm complete all as specified and as directed.
S&F in repair CI vent cowl 100 mm complete all as specified and as directed.
S&F in repair CI gully trap 125/110 mm setting and jointing with solvent complete all as specified and as directed.
S&F in repair CI floor trap 75mm with grating including jointing with solvent complete all as specified and as directed.
S&F in repair 20 mm dia Aluminium anodised alloy decorative type curtain rod with fixing of brackets complete all as specified and as directed . ( Note : brackets shall be paid separately)
S&F in repair bracket of curtain rod of aluminium anodised complete all as specified and as directed .
M &L two coats of synthetic enamel paint over a coat of pink primer including preparation of newly wooden surfaces complete all as specified and as directed .
M&L one coat of synthetic enamel paint including preparation of old wooden surfaces complete all as specified and as directed .
M&L two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surfaces complete all as specified and as directed .
M&L one coat of synthetic enamel paint including preparation of old steel surfaces complete all as specified and as directed .
M & L Preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion over a one coat of primer on walls complete all as specified and as directed .
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coats of distemper including a coat of primer on walls complete all as specified and as directed .
M & L preparation of newly plastered surface and applying three coats of white wash on ceilings complete all as specified and as directed .
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coats of white wash on ceilings complete all as specified and as directed .
M&L for preparation of newly plastered or concrete surfaces of wall and applying two coat of cement base paint over a coat of lime wash complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coats of cement base paint over and including a coat of primer complete all as specified and as directed (Note:The work is to be carried out up to 8th story of building)
M & L for PCC 1:2:4 type B1 (20 mm graded aggregate) as in bed for PVC water tank, roof kerbs benching rounded or chamfered on edge complete all as specified and as directed
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm graded stone aggregate including making joints & filling with sand bitumen mastic complete all as specified and as directed .
M & L framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work conforming to Fe 290,Gde - E-165 complete all as specified and as directed . .
S&F SS 900x800mm plate rack fixed in position including all necessary fittings complete all as specified and directed
S&F PVC (SWR ) for branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches (Supplied and fixed bore of pipe in 110mm) complete all as specified and directed
S&F Door vision eye (Magic eye ) complete all as specified and directed
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S & F Mild TMT steel bars 6 to 8 mm dia TMT bars cut to length , bent to shape required including cranking ,hooking end and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed
M & L Form work to chajja, fins, parapet wall & roof projection complete all as specified and directed
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide fair finished surface complete all as specified and directed
M & L RCC 1:2:4 as in chajja, fins, parapet wall & roof projection complete all as specified and directed
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M & L for machine cut kota stone one piece on slab , landing ,steps, flooring etc. 18-20 mm thick over 15 mm thick cement screed in CM (1:6) based laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish including moulded the edges complete all as specified and as directed
M&L for machine cut kota stone slab 18-20 mm thick in one piece as in riser of steps, skirtings, dados etc over 10 mm thick cement screed in CM (1:6) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish complete all as specified and as directed
Taking down rainwater pipes (any Size or pattern), including all fittings, cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed
S&F PVC (SWR) pipes of 110 mm bore single socketed, in any length with rubber ring joints, fixed with walls or trenches complete all as specified and as directed .
S&F PVC (SWR) bends any radius for 110 mm bore PVC pipe with cement joints complete all as specified and as directed.
M & L for complete removal of existing any type of existing roof treatment including bedding layer of concrete/mud any thickness in cement mortar and disposing off from MOD land complete all as specified and as directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of APP membrane finished even and fair using WPC complete all as specified and as directed ..
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polyester non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 / kg at 25 degree and viscosity of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface torch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest.APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane tourch. This treatment shall be done by the approved authorised applicator. Guarantee of treatment shall be for 10 years. Thereafter, APP membrane shall be painting with two coat of water proofing paint with aluminium finish. (ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
M & L for PCC 1:2:4 type B0 (12.5 mm graded aggregate) as in levelling course over RCC roof surfaces complete all as specified and directed.
M & L for PCC 1:2:4 type B0 (using 12.5mm graded aggregate) for roof kerbs, benching rounded or chamfered on edges with necessary form work etc complete all as specified and directed.
S&F in repair to rotational moulded vertical water storage tanks triple layer of 500 litre capacity ( White colour) with closed tops ( cylindrical ) hoisted and fixed in position including disconnecting and refixing the existing GI fitting and pipe complete all as specified and directed
S&F in repair of gun metal, gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2, for iron pipe of size 20 mm bore complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, precast concrete blocks etc.complete all as specified and as directed
M & L for brick work with sub-class `B' bricks , straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and as directed
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for post Anti Termite Treatment of soil under existing floors using emulsion @ 01 litre per hole, 300mm apart including drilling & plugging 12mm dia holes with CM(1:2) (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Anti Termite treatment by treating the soil under plinth protection @ 5 litres of emulsion per Sqm of surface area complete all as specified and as directed
M &L post Anti termite treatment along the external wall below concrete or masonry apron and wooden joinery using chemical emulsion @ 2.25 litres per linear metre including drilling & plugging holes etc. in apron complete all as specified and as directed .
Removing of IGL gas meter and pipe line from the current position after stopping the gas supply, for tiling/civil work & refixing the IGL gas meter and pipe line and restarting supply of gas after completion of work complete all as specified and directed. Note :- 1. The work for removal/refixing of IGL gas meter and pipe line shall be carried out through IGL and payment & all necessary arrangement for the same shall be carried out by the contractor. Cost towards payment of charges to IGL personnel shall be deemed to be included in quoted rate. 2. Contractor shall be solely responsible for safe execution of work from shutting down the gas supply till resuming the gas supply properly after completion of tiling work. Any damages caused during execution shall be borne by the contractor.
Taking down of old /unserviceable kitchen cabinet / Cupboard including all fixture and fittings complete all as specified and as directed . Note: For measurement superficial area in elevation will be measured.
S&F factory made 18mm(+ 0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company, one side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabinet shutter complete all as specified and as directed
S&F factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company,Plain 18mm thick Celuka PVC Ply for Shelves/Partitions/Drawers complete all as specified and as directed
S&F factory made 5mm thick PVC sheet of density 600kg/cbm manufactured by an ISO-900-2008 certified company, Plain 5mm thick PVC sheet paneling for back side(wall side) complete all as specified and as directed
S&F 100 mm size Stainless Steel handle complete all as specified and as directed.
M &L for 50 mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F 38mm size Stainless Steel Piano hinges complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness( below or above ground floor) complete all as specified and as directed..
M&L for PCC (1:4:8 ), Type D2, using 40mm graded mechanically crushed store aggregates as in foundations, filling, sub base and mass concrete complete all as specified and as directed.
M&L for sand filling under floor cushioning for interlocking tiles including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block with grey cement and no pigment of any shape and size conforming to IS-15658-2021 of 60 mm thickness, M-35 grade complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light ,fan, light fittings,socket or power) complete, such as switches, ceiling roses, pendants, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
For one light point controlled by one SP switch
For one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
For one light point controlled by two 2 - way SP switches
For one bell point controlled by one No bell push
All as per item No-126 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size complete all as specified and directed .
All as per item No-126 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 2.5Sqmm size complete all as specified and directed .
All as per item No 126 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100V grade IS -694 FRLS cable for continuous earth wire connected to gang box of required size all as specified and directed
S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed
S&F socket outlet flush type 5 pin 6 amps suitable for 240 volt AC complete all as specified and directed
Supply and fix switch piano 5 Amps flush type single pole two way suitable for 240 volt AC complete all as specified and as directed
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC complete all as specified and directed
Supply and fix bell push flush type 5 Amps suitable for 240 volt complete all as specified and as directed
Supply and fix bell AC 240 volt ding dong type complete all as specified and as directed
Supply and fix electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete all as specified and as directed .
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed
Supply and fixing LED security light fitting 35 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant toughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suitable GI Pipe light grade 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc complete all as specified and directed
Taking down including disconnecting the electric connection of ceiling fan and dismantling for reuse complete all as specified and directed
Hanging / fixing only ceiling fan received from item No 142 above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed
Taking down including disconnecting the electric connection of exhaust fan and fixing of exhaust fan for reuse complete all as specified and directed
M & L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable complete all as specified and directed .
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable complete all as specified and directed .
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed Note :- MCB shall be measured and paid separately
Taking down old unserviceable MCB DB of any size complete all as specified and as directed .
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 3 of SSR Part I and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply complete all as specified and directed
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'B' Series complete all as specified and directed
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'B' Series complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Minimum air delivery 210 CFM with minimum service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, Copper winding of sweep 250 mm complete all as specified and directed
Supply and fixing in replacement of factory fabricated sheet steel enclosure phosphatised powder painted single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps C curve 240 Volts 10KA complete all as specified and directed
M&L for refixing for wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed
M&L for refixing for wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed
Taking down existing geyser carefully of any capacity without damaging from bathroom and to be kept in safe custody until completion of finishing work and refixing the same with connection pipe after completion of work complete all as specified and directed . Note : Any damage has to be made good by the contractor to make the item functional after testing.
Supply and fix vertical type electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pieces etc.complete all as specified and directed
Shiv Shankar Nirman Co.
Ashish Sehgal and Co.
CHOPRA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .