Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC | ₹1.6 Cr | 1 | Accepted-AOC Work Allotted |
| 2 | 2₹1.6 Cr+₹7,048.95 (0.05%)Rejected-AOC | ₹1.6 Cr+₹7,048.95 (0.05%) | 2 | Rejected-AOC Unallotted |
| 3 | 3₹1.6 Cr+₹6.3 L (4.07%)Rejected-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹1.6 Cr+₹6.3 L (4.07%) | 3 | Rejected-AOC Unallotted |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
8 Oct 2021, 3:00 pmClosed
Executive Engineer,
Executive Engineer, PHED No. 2 JIND
Padana Construction of independent water works and FHTC in village Padana
2021_HRY_189932_1
HO7361414092021
Open Tender
Civil Works
Works
365 days
Padana
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹3.2 L
15 Dec 2021
27 Sept 2021
8 Oct 2021
27 Sept 2021
8 Oct 2021
27 Sept 2021
Amount
Supply and erection of Horizontal spindle split casing type pumping sets of minimum Four (4) star rating duties directly coupled to Ac sqarrel cage induction type motor with 1440 RPM, 3 phase, 50 HP2 and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. A) Raw Water Pump Set. 700 LPM x 12 Mtrs. Head
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powered coated of approximate size 1200/900mm and 400mm deep having following items:- A) For Raw water pump sets for 700 LPM x 12 Mtrs. head = 2 Nos. (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB). (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS 1 No. & ASS 2 No. each of approved make (f) SPP 1 No. of approved make (g) Motor starter, star delta 2 No. for 700 LPM x 12 Mtrs. Head Motor (L&T Simens, AAB) (h) Capcitor of suitable capacity -2 Nos. (i) Indicating Lamp-One Set ( j) Change over switch 63 Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powered coated of approximate size 1200/900mm and 400mm deep having following items:- A) For Clear water pump sets for 700 LPM x 40 Mtrs. head = 2 Nos. (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB). (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS 1 No. & ASS 2 No. each of approved make (f) SPP 1 No. of approved make (g) Motor starter, star delta 2 No. for 700 LPM x 40 Mtrs. Head Motor (L&T Simens, AAB) (h) Capcitor of suitable capacity -2 Nos. (i) Indicating Lamp-One Set ( j) Change over switch 63 Amp. = 1 No.
Supply, erection, testing of ISI makred copper wire for 4 nos. motors with underground system in PVC and flexible pipes copper wire size 6 Sq mm complete in all respects with accessories like thimble etc. complete in all respects.
Supply, erection, testing of ISI marked copper wire for 2 Nos. panel boards from main switch to panel and wiring of panel with size 10 Sq. mm (copper wire) ISI marked complete in all respect with accessories like thimble etc. complete in all respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in all respects.
Supply, erection, testing of reputed make LED light 100 watts with fitting and accessories complete in all respects.
Operation and maintenance for the complete scope of work mentioned in the DNIT (Disinfection material supplied by the PHED) as per schedule -IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/Mtc. estimate). complete in all respects. Operation and maintenance during defect liability period (operation only) after 3 month trial run period.
For 1st year Operation and maintenance after defect liability period
For 2nd year Operation and maintenance
For 3rd year Operation and maintenance
For 4th year Operation and maintenance
For 5th year Operation and maintenance
Bidder Name
Amount
Sunil Kumar(GSTN-06BMGPK6616K1ZU)
Rajinder Parshad Jain Contractor Jind(GSTN-NA)
RAJ KUMAR SINGLA CONTRACTOR(GSTN-NA)
Rajinder Parshad Jain Contractor Jind
Sunil Kumar
Sunil Kumar
RAJ KUMAR SINGLA CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .