Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹2.8 L
Closing Date
17 Mar 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have minimum eligibility criteria as given below: Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any of the following (by any Government organizations) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turn over of Rs.500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Any Relay Interlocking or Electronic Interlocking or Automatic Block Signalling or Intermediate Block Signalling/Intermediate Block Hut work involving Indoor and Outdoor Work (Cable laying and Termination).Note1:Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40/60 as the case may be) criterion of similar nature of work.Note2:a. Submission of 'Undertaking by the tenderer' that the equipment for EI or Axle Counter or AFTC or UFSBI shall be procured from RDSO approved sources and installation, testing and commissioning of EI or Axle Counter or AFTC or UFSBI shall also be got done from the same source including after sales support required during the warranty period. AND b.The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extent RDSO guidelines and to meet contract specific requirements.
27 conditions · 17 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Care In Submission of Tender : (In terms of Railway Board letter NO : 2017/CE-I/CT/4/GST dated : 23.06.2017)
(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/Integrated Goods and Services Tax Act, 2017 (IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderer will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under CGST/IGST/UGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UGST/SGST Act to railway immediately after the award of contract without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority
In case the successful tenderer is not liable to be registered under CGST/IGST/UGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority
Balance Outdoor and Indoor Works of EI (M/s Medha Make) including part supply of materials i.c.w Replacement of signaling gears with Electronic Interlocking at Delhi Shahdara station of Delhi division on Northern Railway
Project_DLI_SNT_04
Project_DLI_SNT_04
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹2.8 L
17 Mar 2026
23 Feb 2026
3 Mar 2026
147 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,61,25,377.41 | ||
| — | 2.00 | — | — | ||
| Supply installation and testing of IOCOM CPU card. Inspection: RDSO | — | — | — | 1,32,782 | |
| — | 2.00 | — | — | ||
| Supply installation and testing of IOCOM VOLTAGE and HEALTH MONITORING Card. Inspection: RDSO | — | — | — | 51,708 | |
| — | 5.00 | — | — | ||
| Supply installation and testing of INPUT WFM CPU CARD. Inspection: RDSO | — | — | — | 1,60,080 | |
| — | 3.00 | — | — | ||
| Supply installation and testing of OUTPUT WFM CPU CARD. Inspection: RDSO | — | — | — | 1,25,979 | |
| — | 3.00 | — | — | ||
| Supply installation and testing of WFM RELAY DRIVER CARD. Inspection: RDSO | — | — | — | 87,894 | |
| — | 1.00 | — | — | ||
| Supply installation and testing of OCM VITAL CUT-OFF CARD. Inspection: RDSO | — | — | — | 47,696 | |
| — | 2.00 | — | — | ||
| Supply installation and testing of POWER SUPPLY CARD TYPE B. Inspection: RDSO | — | — | — | 39,184 | |
| — | 2.00 | — | — | ||
| Supply, installation and testing of POWER SUPPLY CARD TYPE C. Inspection: RDSO | — | — | — | 67,212 | |
| — | 2.00 | — | — | ||
| Supply, installation and testing of SINGLE MODE RS485-OFC BI-DIR. CONVERTER | — | — | — | 1,87,514 | |
| — | 2.00 | — | — | ||
| Supply, installation and testing of 24V EMI FILTER. Inspection: RDSO | — | — | — | 15,704 | |
| — | 1.00 | — | — | ||
| Supply, installation and testing of OC Cardfiles, Enclosure with mounting arrangement, consisting of OC TOP & BOTTOM BACKPLANES (Two object controllers are accommodated in single enclosure) | — | — | — | 3,42,390 | |
| — | 200.00 | — | — | ||
| Supply of Relay vital complete with base and connectors etc. Q Series Relays with base (All Type relays Q- series relays QN1/QNA1/QSPA1/QBCA/QECX as per the Station Requirement. Inspection : RDSO | — | — | — | 16,58,600 | |
| — | 20.00 | — | — | ||
| Supply, installation and testing of DC-DC CONVERTER. Inspection: RDSO | — | — | — | 5,61,520 | |
| — | 25.00 | — | — | ||
| Supply of QTA2 relays AC immunized plug in type DC 9 Ohm neutral track relay miniature tractive armature with 2F/1B contacts as per BRS : 939A or latest amendments if any, BRS :966-F2, IRS-S-34 & IRS-S-23 (as applicable) (Inspection: RDSO) | — | — | — | 1,20,864.5 | |
| — | 50.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. ( Inspection: RITES) | — | — | — | 12,67,425 | |
| — | 50.00 | — | — | ||
| "Casting, concreting and curing of foundation and erection of App. Cases (Single) of size (1160 mm x 760 mm) at surface and 650mm deep as per drg. No.NR/S&T/CON/2.7/97. A layer of 3mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All materials such as cement, sand, aggregate and anchor bolts etc shall be supplied by the contractor. App. Case (Single) will be supplied by railways. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. (Inspection: Site Incharge )" | — | — | — | 3,35,894 | |
| — | 20.00 | — | — | ||
| Preparation & fixing of Bakelite (Hylum Grade P2) sheet 910x800x6mm and teak wooden shelf 900x450x25mm duly fixed by angle iron piece of different size inside App. Case single involving wiring of relays. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts.Fixing of fuses, ARA terminal, shelf type Q series relays and other type relays on square bars and wiring, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled for each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Size of lettering will be 100mm or as per instructions of Engineer at site. Painting from out side as well inside with red oxide and aluminium paint is covered separately. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses, bases, nuts, bolts and other items shall be supplied by the contractor. Relays and ARA terminals only shall be supplied by the railways.(Inspection: Site Incharge ) | — | — | — | 1,38,785.2 | |
| — | 30.00 | — | — | ||
| Preparation & fixing of Bakelite (Hylum Grade P2) sheet 910x800x6mm and teak wooden shelf 900x450x25mm duly fixed by angle iron piece of different size inside App. Case single not involving wiring of relays. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts.Fixing of fuses, ARA terminal, shelf type Q series relays and other type relays on square bars and wiring, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled for each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Size of lettering will be 100mm or as per instructions of Engineer at site. Painting from out side as well inside with red oxide and aluminium paint is covered separately. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses, bases, nuts, bolts and other items shall be supplied by the contractor. Relays and ARA terminals only shall be supplied by the railways.(Inspection: Site Incharge ) | — | — | — | 1,71,088.8 | |
| — | 6.00 | — | — | ||
| Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement :- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes , terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joinEs complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included.(d) Fixing of TL 3Bs as per drg. No. (NR/SandT/CON/3.2/97) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL3Bs with provision of M- 6 terminals. TUB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 30 Ohms, track relays, choke B type (at Feed End and Relay End) and batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays.Supply of TF battery charger, batteries, relays will be done by the Railway.(f) Commissioning of track circuits as per prov.of para of IRS specn. 5- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. (Inspection : By Site Incharge) | — | — | — | 86,061.06 | |
| — | 2000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1. 1/97-A) so as not to form a drain, 0.3 Mtrs. Wide & 1 Mtr. deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser/deeper depth for more number of cables will be paid proportionately. (Inspection: Site Incharge) | — | — | — | 1,69,360 | |
| — | 100.00 | — | — | ||
| Excavating and refilling of trench 0.3 Mtr. Wide and 0.8 Mtr. Deep on pitched/Stone/bricks paved surface, road crossing/platform etc. and restoring the surface to its original conditions. Lesser depth of the trench is to be paid proportionately. (Inspection: Site Incharge) | — | — | — | 13,247 | |
| — | 16000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per drg. No. (NR/S&T/CON/1. 1/97 A) as per instructions of the site Engineer. Per unit means per brick. (Inspection: Site Incharge) | — | — | — | 1,44,160 | |
| — | 5000.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011 or latest, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level.(Inspection : RITES for DWC pipe and Site Incharge for Site Work. ) | — | — | — | 1,09,68,050 | |
| — | 100000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per drg. No. (NR/S&T/CON/1.1/97) and as per cable route plan approved by Railways. Meggering of cable before and after its laying of all type of outdoor cables. (Inspection: Site Incharge) | — | — | — | 9,68,000 | |
| — | 7000.00 | — | — | ||
| "Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately after termination of cable. This also includes dressing & lacing of cable on both ends. Performa for testing & material for lacing to be supplied by the contractor. (Inspection: Site Incharge)" | — | — | — | 1,09,480 | |
| — | 50.00 | — | — | ||
| Supply and installation of RFID electronic Marker for S&T underground cables with programmable memory for saving the user specific data inside the RFID Electronic Marker Memory chip later recordable by Electronic Locator which can be burried up to depth of 5 feet. (Inspection: RITES for Supply, Installation by Site Incharge) | — | — | — | 1,17,265.5 | |
| — | 1.00 | — | — | ||
| Supply of Integrated Electronic Cable route locator with high power 12W transmitter for effective long distance locating, 4 active locative frequencies (577Hz, 8kHz, 33kHz, 200kHz) depth range up to 3 meter passive power frequency, current and resistance measurement in both- transmitter and receiver, super induction mode with capability of electronic marker locating (both passive ad RFID) and sheath fault locatting in a single equipment, allows software to be downloaded from website, weight less than 2.5Kgs for transmitter as well as receiver, signal current measurement in cable. ( Model 2273 Mid, 3M India Ltd or Similar) Inspection: Consignee | — | — | — | 4,23,030 | |
| — | 50.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. (Inspection: Site Incharge) | — | — | — | 1,77,115.5 | |
| — | 100.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary ) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Site Incharge) | — | — | — | 3,74,846 | |
| — | 50.00 | — | — | ||
| Earth work around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. . The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes shall be upto the plaster level and for width sufficient for the maintainer to attend the box both from front & back side). (Inspection: Site Incharge) | — | — | — | 7,578 | |
| — | 2.00 | — | — | ||
| Supply of power wires 1x6sqmm. (Red & black), IS 694/1990 or latest. (Inspection: RDSO) | — | — | — | 1,23,128.58 | |
| — | 1.00 | — | — | ||
| Supply of power wires 1x16sqmm. (Red & black), IS 694/2010 or latest. (Inspection: RDSO) | — | — | — | 1,70,994.9 | |
| — | 1.00 | — | — | ||
| Supply of power wires 1x25sqmm. (Red & black), IS 694/2010 or latest. (Inspection: RDSO) | — | — | — | 2,68,113.04 | |
| — | 2.00 | — | — | ||
| Supply of Flexible , PVC sheathed, PVC insulated Copper wire 16/.20 sq mm (wiring materials) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest. (Inspection: RDSO) | — | — | — | 17,967.3 | |
| — | 2.00 | — | — | ||
| Supply, installation & wiring of Earth leakage detector, 12 channels, for monitoring different AC and DC supplies including all accessories as per specifications No.RDSO/SPN/256/2002 or latest and stipulations of tender document. (Inspection of ELD by RDSO and Installation by Site incharge) | — | — | — | 3,60,717.08 | |
| — | 5.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angle iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide,painting & description etc. with ISI mark paints. Per unit means per board. (Inspection: Site Incharge) | — | — | — | 1,10,868.9 | |
| — | 12.00 | — | — | ||
| Supply fixing and wiring of fuse auto changeover system (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor (Inspection :RDSO for supply portion and site work by Site Incharge) | — | — | — | 5,11,056.84 | |
| — | 1.00 | — | — | ||
| Fabrication, wiring & supply of Simulation panel as per drawing no. SSTE/ PS/1562 dt. 5.3.2001. This includes wiring from Relay room to the simulation panel. ARA terminals and fuse bases shall be supplied by Railway. All materials such as on/off/2way switches, wires, strips & tag blocks etc. to be supplied by the contractor. (Only indoor cables for wiring between relay room and simulation panel shall be supplied by Railways.). (Inspection: Consignee/Site Incharge) | — | — | — | 6,499.97 | |
| — | 1.00 | — | — | ||
| "Fabrication, wiring & supply of lamp board as per drawing no. SSTE /PS / 1563 dt. 5.3.2001. This includes wiring from Relay room to the lamp board. All materials such as wires, strips, tag blocks, lamps & holders etc. including sufficient lamps for testing to be supplied by the contractor. (Only cables for wiring between relay room and lamp board shall be supplied by Railways). (Inspection: Consignee/Site Incharge)" | — | — | — | 11,010.36 | |
| — | 8.00 | — | — | ||
| Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site Engineer. It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm with end cap to be provided along with the drum at both ends (RDSO specs No. RDSO/SPN/TC/45/2013 rev 2.0) ( Inspection: Supply portion by RITES and execution portion by Site Incharge) | — | — | — | 5,71,185.6 | |
| — | 11.00 | — | — | ||
| Blowing/drawing of OFC Cable in the HDPE Duct by Mechanical System (Inspection: Site Incharge) | — | — | — | 1,27,579.76 | |
| — | 1.00 | — | — | ||
| Supply, Installation, commissioning of fault locator for short circuit detection in fire alarm loop required as per UL listed solution and RDSO/SPN/217/2016 ver 2.0 or latest. (Inspection: RDSO/RITES for supply portion and Site Incharge for execution) | — | — | — | 5,947.55 | |
| — | 20.00 | — | — | ||
| Supply,installation, Commissioning Heat and Smoke Multi sensor detector with automatically Adjusts sensitivity levels without the need for operator intervention or programming sensitivity increase with heat varying and floating Sensitivity from 0.5 to 4% /Ft and shall be plug in type facility and address through switch.The baseshould also be supplied as per RDSO/SPN/217/2016.Ver 2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 1,22,857.8 | |
| — | 1.00 | — | — | ||
| "Supply, Installation, commissioning of Analogue addressable UL listed fire alarm control panel with 80 character display with battery charger and battery backup for 24 Hr normal operation and addressable power and alphanumeric keypad for installation for the FAS panel and 1000 event recording facility without GSM RDSO/SPN/217/2016 Ver.2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution)" | — | — | — | 5,83,168.88 | |
| — | 150.00 | — | — | ||
| Supply, Installation, commissioning of Analogue Type linear Heat Sensing(LHS) cable which is self restorable after the fire event as its temperature do not exceed specified resettable temperature limit of 120 degree activation temperature of 70 degree Celsius as per RDSO/SPN/217/2016 Ver.2.0 or latest (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 2,72,223 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Commissioning of UL listed glass break manual call point as per RDSO/SPN/217/2016,Ver 2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 11,788.52 | |
| — | 2.00 | — | — | ||
| Supply, Installation, commissioning of audio visual alarm unit as per RDSO/SPN/217/2016 Ver.2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 23,313.68 | |
| — | 1.00 | — | — | ||
| Supply, Installation, commissioning of end of linear Heat sensing interface module as per RDSO/SPN/217/2016 Ver.2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 1,51,085.88 | |
| — | 1.00 | — | — | ||
| Supply, Installation, commissioning of end of line box for linear Heat sensing interface module as per RDSO/SPN/217/2016 Ver.2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 5,341.8 | |
| — | 150.00 | — | — | ||
| Supply, Installation, commissioning of circuit integrity cable 2 core 1.5 Sq.mm as per RDSO/SPN/217/2016 Ver.2.0 or latest. (INSPECTION: RDSO/RITES FOR SUPPLY PORTION and Site Incharge for execution) | — | — | — | 44,278.5 | |
| — | 10.00 | — | — | ||
| Supply and fixing of ISI marked Carbon di Oxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS: 2878 from seamless cylinder confirming to IS: 7285 with IS marked control value conforming to IS: 3224 high pressure myr. Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer. (Inspection : Consignee) | — | — | — | 1,09,228.9 | |
| — | 10.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad cable for straight through joints as per IRS: TC-77/2012 (Rev.2) with latest amendments. (Inspection Consignee) | — | — | — | 77,202.3 | |
| — | 10.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad cable and PIJF cable for Derivation/ Termination joints at LC Gates/Pump House/different locations as decided by the site Engineer as per IRS: TC-77/2012 (Rev.2) with latest amendments. This includes all materials required for joints. (Inspection: Consignee) | — | — | — | 77,520 | |
| — | 1.00 | — | — | ||
| "Supply of SM/SI/ESM furniture of Godrej or similar make consisting of the following :- 1. Executive revolving bearing series low back floating chair with normal arms cushioned chair: 1 No. 2. Executive Table size 72x36x30"" with 3 drawers one side, lockers cabinet on other side: 1 No. 3. Visitors chair seat & back cushion with high density Foam with plastic PVC handle capsule type flat pipe duly painted black: 3 Nos.4. Almirah steel with locking arrangement size 48""x30""x17""=1No. (Inspection: Consignee/Site Incharge)" | — | — | — | 48,529.18 | |
| — | 1.00 | — | — | ||
| "Supply of tool kit for JE/SE/SSE for Maintenance as per tech spec. given below: (1) Digital Multi Meter suitable for axle counter ranges 20 Amp AC/DC make protek 506 or similar- 1 no. (2) Digital clamp Multi Meter range up to 100 Amps for AC/DC current make SEW or similar - 1 no. (3) Leather Tool Bag for keeping tool kit -1 no. (4) Plier Sealing with sealing code bit -1 no. (5) Plier Wire Cutting 8"" make Taparia or similar -1 no. (6) Nose Plier 4"" make Taparia or similar -1 no. (7) Wire Stripper - 1 no. (8) Screw Driver set multi port type -1 set (9) Track shunt resistance .5 ohm -1 no. (10) Soldering Iron 230V AC/65 watt -1 no. (11) Soldering Iron 230V AC/35 watt with different type replacement soldering head - 1 no. (12) Soldering Iron 110V AC/35 watt -1 no. (13) Measuring Tape steel 30 meters - 1 no. (14) Measuring Tape steel 3 meters - 1 no. (15) Rechargeable Torch Superior quality -1 no. (16) File Flat 8"" long - 2 nos. (17) File Round smooth 8"" long - 2 nos. (18) File Flat Bestirred 8"" long - 2 nos. (19) Electric Drill Machine Portable 6mm make wolf or similar -1 no. (Inspection: Consignee)" | — | — | — | 59,981.08 | |
| — | 12000.00 | — | — | ||
| Supply of 4 conductor disconnect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- RITES). | — | — | — | 13,08,600 | |
| — | 250.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee) | — | — | — | 34,782.5 | |
| — | 500.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee). | — | — | — | 8,685 | |
| — | 500.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee). | — | — | — | 7,625 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing and commissioning of Electrically Operated lifting barrier assembly as per RDSO Spec no. RDSO/SPN/208/2012 (version 2.0) or latest consisting of 2 nos. of electrically operated lifting barriers, 2 pedestals, 8 contact circuit controller with limit switches of RDSO approved firm, hand cranks, 2 electric motors, 110V AC, without centrifugal switch, 2 GI Boom in 4 sections of 8 feet each with 2 retroreflective stop boards, boom light boxes, NHS counter weight, 2 nos. of boom support for resting boom etc. The item also consists of following iEems: a. Supply of motorized boom locking /unIocking assembly with electrical coil complete (1 no. each) b) Supply of level crossing gate control panel floor mounting type with swithches and buttons sheet metal fabricated, (1 No) c) Supply of push button for operating the gate wiEh 2 NO/NC contact, green colour-close & Amber-open, Siemens or Kaypee or similar make (1 no. ) d).Supply of solid state electronic flasher 24V DC operated (1 no. each). e) Supply of dual tone warning bell with 20W horn & 15W amplifier (2 no.each). Inspection : RDSO Installation & Commissioning of LC gates includes excavation & casting of foundation of 1:3: 6 for pedestal and boom rest with contractor's own material including cement, anchor bolts, erection of lifting barriers assembly right hand/left hand boom complete on the pedestal, fixing of boom support for lifting barrier boom, installation of boom locking devices & control panel, flasher, warning bell with associated warning. This includes power supply connections, wiring and other outdoor Works etc. All materials for installation & wiring shall be supplied by the contractor. Installation to be done by OEM or its authorised dealer. A certificate to this effect to be submitted by contractor. " | — | — | — | 5,43,749.44 | |
| — | 1.00 | — | — | ||
| Supply of spare electric operated lifting barrier GI Boom as per latest RDSO Drg S- 11600 in maximum 4 sections of 8feet each. Inspection : RDSO/RITES | — | — | — | 35,129.02 | |
| — | 1.00 | — | — | ||
| "Design and preparation of wiring diagram for Level-Xing MACLS on the basis of approved interlocking plan, typical circuit diagram and as per Railway practice and latest rules prescribed by the Railway and obtaining approval of the competent authority. Preparation of locking tables and dog charts to suit colour light signalling plan and obtaining the approval of the competent authority. Drawing shall be supplied as per following:- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software backup of complete set in the form of CDs. (iii) The complete set of tracings. (iv) Design through CAD. (v) Drawing in A3 & plans in bigger size (6 sets). Inspection: SSE/D&D" | — | — | — | 24,185.25 | |
| — | 1.00 | — | — | ||
| Fabrication and installation of illuminated indication Diagram Board of salwood with white sunmica top having aluminum angle of size 1"x1"x1/8" on all 4 sides duly painted for station working rule diagram in Level Crossing. Board of size 1.2m x 0.6m x 20 mm thick shall be provided. The indications for signal, slot etc shall be provided near the signal painted on the yard diagram. It includes of all materials like LED, Holders ,wires etc will be supplied by the contractor. | — | — | — | 5,578.09 | |
| — | 10.00 | — | — | ||
| Suly and fixing of 50 mm wide red/yellow coloured retro reflective highlighter marker tape mad eof non metalised poly carbonate micro-prismatic lenses confirming to AIS specification for fixing on BSLB/SLB boards/Stop signals/LC gates. Make 3M india lTd or equivalent. Inspection : Consignee | — | — | — | 5,515.9 | |
| — | 1.00 | — | — | ||
| Supply, installation, wiring and commissioning of Secured L.C. Gate electronic 1+6 nos Telephone System with inbuilt voice recorder in 1+6 configuration with central supply as per . Specification No. RDSO/SPN/TC/51/2011 Rev.3.0 or IatestSupply of L.C. Gate Telephone System with inbuilt voice recorder in 1+6 configuration with central supply as per . Specification No. RDSO/SPN/TC/5 1/2011 Rev.3.0 or latest. Inspection : RDSO | — | — | — | 76,490.76 | |
| — | 1.00 | — | — | ||
| "Supply, installation and wiring complete KLCR and its box in ASM office /LC Gate or fixing in L-Box. Supply of Key Lock Relay(KLCR) type TMA 24V DC with 2F/2B contact configuration with different wards combinations as per RDSO Specificatins RDSO/SPN/2 19/2016 Ver 1.0, Amd.-1. Supply, installation, wiring of heavy duty push buEton, LED indicator on MS sheet as per N.R. practice for Crank handle locking. This work includes fixing and wiring of magneto telephones with all accessories including standard Battery Box and 3 Nos. of 6 I cells as per instructions of the Site Engr. This includes all materials such as heavy duty push button, LED indicator (1Omm), MS sheet of 4. Smm thick, nuts and bolts, fixing materials for the magneto telephone including standard Battery Box and 3 Nos. of 6 I cells and wiring materials to be supplied by contractor. (Inspection : RDSO for supply portion and Installation by Site Engineer)" | — | — | — | 16,843.96 | |
| — | 1.00 | — | — | ||
| Supply of emergency sliding boom complete with all accessories for LC gate. Inspection : RITES | — | — | — | 2,42,899.23 | |
| — | 1.00 | — | — | ||
| Casting , concrete, curing of foundation for (installation and commissioning) sliding boom gate, fixing of sliding boom & Lock as per Railway engineer at site. All materials such as anchor bolts, cement, & aggregate to be supplied by the contractor. Inspection : Site Incharge | — | — | — | 41,475.31 | |
| — | 500.00 | — | — | ||
| Supply, laying and fixing of HDPE double wall corrugated (DWC) duct as per RDSP spec no. RDSO?SPN/204/2011 Ver 1.1 with Amdt 1 (outer dia 120 mm in 6 m st length with one coupler for every 6m length). All the materials cement, sand etc are to be supplied by the contractor. This include brick work and other arrangments required to secure the pipe as per specifications ,d rawings and stipulations of tender documents and as per approved cable route plan including road crossing /platform /track crossing and for bridges and culverts etc. Inspection: RITES for DWC pipe. | — | — | — | 2,22,290 | |
| — | 1.00 | — | — | ||
| Installation, testing & commissioning of HASSDAC/SSDAC System complete by OEM or its authorised dealer.This also includes integration with existing SGE/TokenIess/Token block instruments were required as per instructions of site engineer. The wire and other wiring material will be arranged by contractor at site. PPCL to be filled by OEM authorized / representative. Inspection : Site Engineer | — | — | — | 77,397.92 | |
| — | 1.00 | — | — | ||
| Installation and commissiong of block proving with digital axle counter as per IRS: S- 105/2012 using UFSBI and block panel for Single line / Double line operation. Wiring material (16*0.02mm flexible wire etc) and any other signaling material for installation and commissioning of system shall be supplied by the contractor. PPCL to be filled by OEM authorised /representative. Inspection : Site Engineer | — | — | — | 69,314.55 | |
| — | 2.00 | — | — | ||
| Supply & installation of DAC- E-1 : E-1 interface for Digital Axle counter (SSDAC & HASSDAC) as per instruction of site engineer. Inspection : Consignee | — | — | — | 2,27,184.82 | |
| — | 1.00 | — | — | ||
| Supply of OFC integrated acess device IU height or 1.5 U height / 19 " rack mountable for LVCD / Digital axle counter purpose ; optical module integrated in the unit supporting dual core OFC and one 100Mbps Ethernet port for survilance / smoke detector ; optical distance support to be 20 kms ; unit to support one E & M module supporting four 2W / 4W ( each port configurable ) to support axle counter / UFSBI / Control phone / EC / RTU / and one TELNET / SNMP port ; unit to support DC / AC power supply ; unit to support change over mechanism between quad and optical fiber for E & M option ; one number cable to be provided along with unit for E & M ; FABIO / 2CX / OFC / DC & Module 2W / 4W four port : Make : TEAM ENGG / FABIO / WAVES or similar / TANSY. Inspection : Consignee | — | — | — | 2,35,527.7 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
Tender_docuement_Balance_DSA.pdf
ATTACHMENT
SIP_Shahdra_EI_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .