Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.3 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹55.6 L+₹1.3 L (2.37%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹66 L
EMD Value
₹66,000
Closing Date
14 Feb 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer
Town Panchayat, Naranammalpuram.
Construction of 2.00 LL capacity of OHT 16.00 m Staging height, Replacement of branch pumping min to newly proposed OHT from Tapping point for Naranammalpuram Town Panchayat.
2024_DTP_421624_1
255/2023
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
Works
Naranammalpuram Town Panchayat
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹66,000
Yes
8 Oct 2024
9 Feb 2024
14 Feb 2024
9 Feb 2024
14 Feb 2024
9 Feb 2024
Amount
Earth work excavation in hard stiff clay, All soil murram, ordinary gravel stoney earth mixed with 50% fair sized boulders etc., I st depth of 2.00 m
Soft disintegrated rock and soft rock not requiring blasting II nd depth 2.00 m to 3.00 m
Supply and filling the foundation and basement with stone dust in layers complying with standard specification .
Plain Cement concrete 1:4:8 (one cement, four sand and eight course aggregate of 40mm size hard blue granite broken stone) for levelling course for foundation including the cost of mixing, placing the concrete in position, consolidating finishing
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete (i) below 1.50m to 4.50m depth from G.L
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Below G.L upto 1.50m depth
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above G.L upto 4.50m height
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above 4.50m to 7.32m ht., from G.L
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above 7.32m to 10.98m ht., from G.L
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above 10.98m to 14.64m ht., from G.L
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above 14.64m ht., to 18.30m ht.,
Reinforced cement concrete M30 design mix using 10mm and 20mm Hard Broken Stone. The rates excluding the cost of supplying, fabricating and placing in opposition of MS / RTS Grills for reinforcement and centering, strutting & shuttering, etc complete Above 18.30m ht., to 21.96m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) Upto 3.30m ht., from G.L
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 3.30m to 4.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 6.30m ht., to 7.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 10.30m to 11.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 11.30m to 12.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 15.30m to 16.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) Centering for square column - upto 3.30m ht.
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 3.30m to 4.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 4.30m to 5.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 5.30m to 6.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 6.30m to 7.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 7.30m to 8.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 8.30m ht., to 9.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 9.30m ht., to 10.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 10.30m ht., to 11.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 11.30m ht., to 12.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 12.30m ht., to 13.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 13.30m ht., to 14.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 14.30m ht., to 15.30m ht.,
Curved Surface Centering for curved surface From 14.30m to 15.30m ht., from G.L
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 15.30m to 16.30m ht., from G.L
Curved Surface Upto 0-3.30 m,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) 3.30 to 4.30 m,
Centering for circular column upto 3.30m ht., from floor level
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 3.30m to 4.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 4.3m to 5.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 5.3m to 6.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 6.3m to 7.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 7.3m to 8.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 8.3m to 9.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 9.3m to 10.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 10.3m to 11.30m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 11.3m to 12.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 12.3m to 13.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 13.3m to 14.3m ht.,
Centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3m ht., using MS sheet of size 90cm x 60cm and BG. 10 gauge stiffened with welded MS angles of size 25mm x 2mm x 3mm laid over silver oak (country wood) From 14.3m to 15.3m ht.,
Supplying, fabricating and placing in position of RTS grills for reinforcement for various members including cost of steel for all RCC works etc., complete as per standard specifications and as directed by Engineer-in-charge. The rate to include the cost
Painting two coats with approved cement paint best quality over the outer wall surface including cost of cement paint etc. complete complying with standard specification etc., complete as per standard specifications and as directed by Engineer-in-charge
|Supplying and fixing in position of RCC M30 in side access ladder of following size using 20mm size HBS jelly |including cost of all materials, centring, shuttering,strutting,fabrication and placing in position of steel finishing curing etc complete as directed by Department officers
Construction of RCC spiral staircase in RCC 1:1.5:3 (1 Cement : 1.5 Sand : 3 Coarse Aggregate) using 20 mm HBGS of 1.80 m diameter of required height for approach to the roof of Service Reservoir with RCC Handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer. The staircase shall be braced to the column of service reservoir at suitable interval. (in the BOQ, quantity column the exact height to be mentioned from GL to roof slab bottom to get total value of work to be done.
Supplying and fixing in position of 0.60 x 0.60m water tight CI manhole frame and cove of approved pattern at the roof slab and as directed. The manhole frame and cover should be of light duty and confirming to IS: 1726-1974
Supply and fixing in position of enamel water level indicator with all accessories of approved pattern and design etc., complete as per standard specifications and as directed by Engineer-in-charge
Supplying and fixing of Providing MS grill steel hand rail of 0.91 m height over the top of roof slab finishing etc complete
Providing and fixing of RCC 1:2:4 (one cement, two sand and four course aggregate of 20mm size hard blue granite broken stone) for ventilators of approved pattern including cost of cement, reinforcement, centering, shuttering, strutting etc., complete
PIPE CONNECTION INLET PIPE 100MMX2.75MCI D/FPIPE
PIPE CONNECTION INLET PIPE 100MMX1.00MCI D/FPIPE
PIPE CONNECTION INLET PIPE 100MMX0.5MCI D/FPIPE
PIPE CONNECTION INLET PIPE 100MMXCI D/F DUCK FOOTBEND
PIPE CONNECTION INLET PIPE 100MMXCI D/FBEND
PIPE CONNECTION INLET PIPE 100MMX2.00MCI D/FPIPE
PIPE CONNECTION INLET PIPE 100MMX1.5MCI D/FPIPE
PIPE CONNECTION INLET PIPE 100MMCI D/FSLUICE VALVE
PIPE CONNECTION INLET PIPE 100MMCI BELL MOUTH
PIPE CONNECTION OUT LET 100MMX2.75MCI D/FPIPE
PIPE CONNECTION OUT LET 10100MMX1.00MCI D/FPIPE
PIPE CONNECTION OUT LET 100MMX0.5MCI D/FPIPE
PIPE CONNECTION OUT LET 100MMXCI D/F DUCK FOOTBEND
PIPE CONNECTION OUT LET 100MMXCI D/FBEND
PIPE CONNECTION OUT LET 100MMX2.00MCI D/FPIPE
PIPE CONNECTION OUT LET 150 MMCI D/FSLUICE VALVE
PIPE CONNECTION OUT LET 150 MMCI BELL MOUTH
PIPE CONNECTION SCOUR 100MMX2.75MCI D/FPIPE
PIPE CONNECTION SCOUR 100MMX1.00MCI D/FPIPE
PIPE CONNECTION SCOUR 100MMX0.5MCI D/FPIPE
PIPE CONNECTION SCOUR 100MMXCI D/F DUCK FOOTBEND
PIPE CONNECTION SCOUR 100MMXCI D/FBEND
PIPE CONNECTION SCOUR 100MMX2.00MCI D/FPIPE
PIPE CONNECTION SCOUR 100MMX1.5MCI D/FPIPE
PIPE CONNECTION SCOUR 100MMCI D/FSLUICE VALVE
PIPE CONNECTION SCOUR 100MMCI BELL MOUTH
PIPE CONNECTION OVERFLOW 100MMX2.75MCI D/FPIPE
PIPE CONNECTION OVERFLOW 100MMX1.00MCI D/FPIPE
PIPE CONNECTION OVERFLOW 100MMX0.5MCI D/FPIPE
PIPE CONNECTION OVERFLOW 100MMXCI D/F DUCK FOOTBEND
PIPE CONNECTION OVERFLOW 100MMXCI D/FBEND
PIPE CONNECTION OVERFLOW 100MMX2.00MCI D/FPIPE
PIPE CONNECTION OVERFLOW 100MMX1.5MCI D/FPIPE
Civil works Earth work excvation for laying pipeline 100MMCI
Civil works Refilling for laying pipeline 100MMCI
Civil works Construction of valve pits 100MMCI
Civil works Vertical laying CIPipes 0-2
Civil works Vertical laying CIPipes 2to4
Civil works Vertical laying CIPipes 4to6
Civil works Vertical laying CIPipes 6to8
Civil works Vertical laying CIPipes 8to10
Civil works Vertical laying CIPipes 10to12
Civil works Vertical laying CIPipes 12to14
Civil works Vertical laying CIPipes 14to16
Civil works Vertical laying CIPipes 16to18
Civil works Horizontal laying 100MMCI
Civil works Jointing CI D/F 100MMCI
Supply and delivery of the following sizes of HDPE Pipes - PE 100 - PN6 conforming to IS:4984/2016, as specified in Technical specifications in standard lengths including labour charges for loading, unloading and stacking at site etc. complete as per standard specifications and as directed by the Departmental Engineer. 110 MM HDPE PN 6 PIPE
Jointing the HDPE pipes and specials with rubber gaskets (tyton joint) including cost of lubricants, cost of jointing materials and testing to the required pressure with water etc., complete as per standard specifications and as directed by the Departmental Engineer. 110 MM HDPE PN 6 PIPE
Lowering the following HDPEpipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer 110 MM HDPE PN 6 PIPE
Earth work excavation for pipe line including all cost of materials and labour cost etc.,
Refilling the excavated earth to site from site including all cost of material and labours cost etc.,
INDIRA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .