Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹42.9 L+₹2.9 L (7.34%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder |
Tender Value
Refer Docs
EMD Value
₹88,700
Closing Date
25 Sept 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) AGRA
HQ CWE (AF) AGRA PIN-282008
PROVN OF SOUNDPROOF DOORS AND WINDOWS OF 159 HU COMPLEX AT AF STN SONEGAON
2021_MES_471411_1
80021-17/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) AF SONEGAON NAGPUR
please refer tender document
7 documents required · 7 mandatory
₹500
AGE (I) SONEGAON NAGPUR
₹88,700
Yes
13 Oct 2021
28 Aug 2021
27 Sept 2021
28 Aug 2021
25 Sept 2021
11 Sept 2021
60 days
Amount
Taking down chowkat or frame area exc 1.50Sqm but nexc 4.00 Sqm with shutter (without taking off shutters from the frames) including iron mongery complete all as specified and directed.
Dismantling of False ceiling (Fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed.
S&F Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc complete all as specified and directed.
S&F second class soft wood in scantlings (timber framed and fixed) of required shape and size complete all as specified and directed.
S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed (2nd class hard wood) complete all as specified and directed.
S&F mild steel work as in frame work such as grills and frame guard bars, in windows including securing bolts including all necessary drillings, bolting or riveting and Rack including MS plate, angle iron etc. and similar work all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar (1:6 ) to be finished even smooth with out using extra cement complet all as specified and directed.
Preparation to new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coat of Synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
M&L for preparation of new plastered surface and applying two coat of oil bound distemper white or any tint over a coat of primer after preparation of wall surface with Birla/Asian wall Putty complete all as specified and directed
Dismantling boarding, any description, fixed in any position with skrew complete all as specified and directed
M&L for PCC (1:3:6) type C1 (Using 20mm graded stone aggregate) as in hold fast block or similar work and finished the surface with existing and including form work.
M&L for laying and fixing of rockwool insulation of 50 mm thick with modest density 50d brought in roll form with necessary cutting and fixing with approved adhesive like Fevicol SR 998 or equivalent and. Provision of GI wire at a suitable interval if required shall be provided with out any extra cost complete all as specified and directed.
All as per item No 12 here in before but in double layer in ceiling. One layer at RCC slab and other layer above frame work of suspended false ceiling complete all as specified and directed.
M & L for providing and fixing GI channel 50mm having web of 25 to 27mm on both sides X 0.5mm thickness with required fitting like anchor bolt, nut bolt etc and placing at 600mm x 1800 mm c/c in grid form. After fixing rock wool GI Flat strip 25mm wide shall be fixed complete all as specified and directed.
M & L providing and fixing 12mm cement bonded fibre reinforced partical board on wooden frames (item taken separately) complete all as specified and directed.
M & L providing and fixing suspended false ceilings as per design at any height which includes GI perimeter channel MF 6 of size 0.4 mm thick having flanges of 20 mm and web of 27 mm along with perimeter of wall . Thereafter suspending GI intermediate channel MF7 at 600 mm c/c of size 45 mm with 12 to 15 mm flange ceiling section MF5 of 0.5 mm thickness having knurled web of 51 mm and two flanges 25 mm each on both side are to be connected each other with connecting clips at 450 to 600 mm c/c suspended with GI angle 25x25 mm with anchor fastners and 12.5 mm thick tapered gypsum board shall be fixed with required fitting and finishing with paper tapes at joints with jointing compound etc complete all as specified and directed.
M & L for providing and applying plastic emulsion paint in two coats with cement based primer including preparation of surfaces with putty etc complete all as specified and directed.
Supply only Green glue synthetic resin complete all as specified and directed.
M& L providing and fixing armstrong make acoustic panelling with 600x600x25 mm size glass fibre jute fabric finish optra wall panel with class 1 fire ratinf and NRC of 0.9 including fixing with all necessary fittings etc complete all as specified and directed.
M & L for providing and laying 12 mm thick woolen carpet by using quality adhesive with approved colour complete all as specified and directed.
M & L for providing and fixing 6 track sliding windows with one shutter in each track with standard specification of Jindal or Hindalco window section 19 mm thick with 5mm thick plain glass with UPVC rubber profile all around the glass, including locking arrangement with handle along with neccessary fitting complete all as specified and directed .
S&F of acoustic soundproof door of thickness of following parameters complete all as specified and directed. Profile System : SYSTEM GOLD ASEA CASEMENT DOOR, Glass : 19 mm Dgu - 1, Profile Color : White Outer : CASEMENT OUTER 58MM X 52MM-2060 Outer RI : REINFORCEMENT 30MM X 16MM-V226-1.2MM Mullion : CASEMENT FLOATING MULLION 58MM X61MM Mullion RI : REINFORCEMENT 35MM X 20MM Casement Sash : CASEMENT OUTWARD SASH 58MM X 93MM Casement RI : REINFORCEMENT 45MM X 30MM Accesories : Handle : Casement Double Side Door Handle Hinge : 3D Hinges
S&F of acoustical soundproof curtains for windows and door along with curtain rod and neccesary fittings complete all as specified and directed.
Taking down carefully copper/aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,s/socket, or power) complet fittings such as switches,ceiling rose,pendents,regulators,sockets etc complete all as directed.
Taking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB's/MCB SP/SPN/TPN complet all as directed.
Taking down old unserviceable tube light/cfl light/recessed mouted light or any type of light fittings complete all as directed.
Taking down old unserviceable Sub Main wiring any type any capacity including conduits from its location & making good of distrube surface all as directed.
Taking down old unserviceable surface mounting fixed cable of size 3.5 core16/35/50/70 Sq mm or any capacity all as directed.
Taking down and refixing ceiling fan/cabin fan/ air ceculating fan/ exhaust fan after cleaning & painting of ceiling fan complete with synthetic enamel paint by spreaying including filling cavities with filler complete all as directed.
M &L for PVC concealed conduit point wiring with 1.5 Sq mm nominal area stranded copper conductor PVC insulated multistranded cable1100 Volts grade conforming to IS694 part-I draw in 20 mm size PVC conduit in concealed including 600 volts grade 1.5 Sq mm copper Multi stranded cable green color PVC insulated for contineous earthing wire with complete chess cutting of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/ junction boxes etc covered the conduit with cement mortor after drawing of electric cables and making good of distrubed surfaces and match with existing shade of wall/roof all as directed for the following:-
(a) One light point controlled by one switch
(b) One Fan/Exhaust Fan controlled by one switch
(c) One three pin 5 Amps switch socket outlet on independent board
(e) One three pin 5 Amps switch socket outlet on same board
(f) One Bell/buzzer point controlled by one switch
All as per item No.30 here in before but point wiring with 2.5 Sq mm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 2.5 Sq mm multistranded copper cable green colour for earth continuity conductor complete as directed.
Refixing of switch piano, flush type single pole,5 Amps, 240 Volts AC obtained from items No 24 complete as directed.
S&F switch piano, flush type single pole,5 Amps, 240 Volts Ac complete as directed.
S&F Bell switch piano, flush type single pole,5 Amps, 240 Volts Ac complete as directed.
S&FBuzzer, Ding Dong AC. 230 volts,single pole, Ac complete as directed.
Refixing of ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC retrived from item No 24 as directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC as directed.
Refixing of switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete retrived from item No 24 as directed.
S&F switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete.
Refixing of switch socket combination 2 IN 1, 3 PIN,5 and 15 flush type universal ,240 Volts, complete retrived from item No 24 as directed.
S&F switch socket combination 2 IN 1, 3 PIN,5 and 15 flush type universal ,240 Volts, complete .
Refixing of Tube light fitting /cfl/LED light fitting/2X2 LED luminaire wall mounted or recessed mounted any type any make any capacity after taking down complete retrived from item No 26 as directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector complete rewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cableMake CG CAT No-CCS-100-20-65-HL2-DP-NWH/Havells/philips/Bajaj.
Refixing of cable any size any cap upto 70 Sqmm fixed on wall/trench with clamps & saddle properly as directed by E-in-charge retrived from item no 28.
Refixing of fan step regulator,120 W,220/230 V AC.retrived from item No 24
S & F Fan regulator electronic stepped type on the phenolic laminated sheet as directed.
S & Lay sub main wiring with 4x10 Sqmm PVC insulated , PVC sheathed , 1100 volt grade as per IS 694, with multistranded copper conductor in and including supply and fixing PVC conduit concealed with all joint , elbow, Tee ,Junction and Bend with necessary ches cutting and filling with cement mortor etc, and provision of one run of PVC insulated , multistranded copper conductor cable of size 2 x 4 Sqmm for earth continuty complete all as directed.
S & Lay concealed sub main wiring with two single core cable of 6 sqmm PVC insulated , 1100 volt grade as per IS 694, with multistranded copper conductor in and including rigid PVC conduit (ISI Marked) including earthing wire of pvc insulated stranded 4 sq mm cable ,chess cutting including S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and makig good of distrubed surfaces and match with existing shade of wall/roof all as directed.
S&F sheet metal enclosure DB triple pole and neutral link double door 415 volts AC 12 way semi concealed type with necessary connection DB with incoming slot for MCB as incomer Make-legrand,Havells,Indoasian.
S&F sheet metal enclosure DB SPN 4 way 240Volt with 200 amps rated bus bar semi concealed type with necessary connection model no-Legrand DB with incoming slot for MCB as incomer Make-egrand,Havells,Indoasian.
S&F sheet metal enclosure DB SPN 8 way 240Volt with Bus bar semi conceled type with necessary connection model No-Legrand DB with incoming slot for MCB as incomer Make-Legrand, Havells,Indoasian.
Disconnecting outer & inner unit of Split Air-conditioning including Voltage stablizer Unit Of any Capacity including Cutting of Copper Tubes & shifting of Outer unit from roof/wall of building with provision of angle iron anchor picket madeout of 25MMX25MMX5MM angle iron with suitable size of MS plate with reinstallation of Outer & inner unit of AC on sound proof wall with Minor repair & the suitable space for further Maintenance including necessary gas charging /topping up R-22/410C with brazzing of copper tubes complete all as specified & directed.
Refixing of DB's including all existing isolator/MCCB,s/MCB,s safly as per the directed by E-in-Charge retrived from item No 25.
S&F MCB 6 Amp with necessary connection in DB box complete all as specified and directed .
S&F MCB 10 Amp with necessary connection in DB box complete all as specified and directed .
S&F MCB 20 Amp with necessary connection in DB box complete all as specified and directed .
S&F MCB 20 Amp DP with necessary connection in DB box complete all as specified and directed .
S&F isolator TPN 63A with necessary connection in DB box complete all as specified and directed .
S&F isolator DP 40A with necessary connection in DB box complete all as specified and directed .
S&Fsemi grouting industrial socket & plug powder coated made of CRCA sheet complete box comprised with MCB, SP 20 AMP 10 KA reputuring cap complete all as specified and directed .
Meet Road Lines
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .