Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected. In adequate experience. Requisite documents not uploaded / submitted |
Tender Value
₹40.0 L
EMD Value
₹80,100
Closing Date
19 Jan 2024, 4:00 pmClosed
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
Additional Electrical Works along Batamaloo-Qamarwari Road falling under the jurisdiction of Sub-Division Street Lights, ED-3rd (Turnkey Basis)
2024_PDD_241925_1
ED-III/19 of 2023-24, Dated - 04/01/2024
Open Tender
Electrical Works
Turn-key
30 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Technical Specification, Drawings
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-3rd srinagar
₹80,100
1 Feb 2024
4 Jan 2024
20 Jan 2024
4 Jan 2024
19 Jan 2024
8 Jan 2024
8 Jan 2024 - 15 Jan 2024
Amount
Additional Electrical Works along Batamaloo-Qamarwari Road falling under jurisdiction of Sub-Division Street Lights, ED-3rd (Turnkey Basis)
Supply,installation, testing and commissioning of 100 KVA, 33/0.433 kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Level-1 of BIS, (Copper wound) including integration with system by way of providing Clamps/ Jumpers/ necessary items required for commissioning. (Specification enclosed)
Supply,installation, testing and commissioning of 33 kV, Lightening Arrestor,(33 kV ,10 kA ,Station class,ZnO, Polymer) gapless
Supply, installation, testing and commissioning of 33 kV Isolator, with Earthing Blade (36kV,800 A, Outdoor, 3 poles, 25 kA) (Incl all allied material)
Supply, installation, testing and commissioning of 33 KV Drop Out Fuse set
Supply, installation, testing and commissioning of Galvanised iron of sorts
Supply, installation, testing and commissioning of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole, provided at height of 300mm above the planting depth which should be 1.5 mtr (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, installation, testing and commissioning of 120 mm² XLPE LT Cable 1 Core, armoured, FRLS including lugs/clamps/thimbles.
Supply and Fixing of 33 KV Polymeric composite Disc Insulator 36 KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply and Fixing of 33 KV Polymeric composite Pin Insulator 36 KV, 10 KN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply, installation, testing and commissioning of Dust/rain/snow-proof canopy type mini-outdoor LT feeder panel of size 450X300mm with front door opening duly powdered colour coated with inbuilt 2 No. TPN 16-32 Amp MCCB,TPN busbars of same capacity installed on cement concrete block with 4 angle iron legs grouted in the cement concrete of termination of main 25 sqmm cable and outgoing 25/16 sqmm cable circuits.
Providing of material and laying of Earthing of 100 kVA SubStation--Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, along with Baby insulators, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply & Fixing of Danger Plates with Clamps
Supply & FIxing of PG Clamps for 100 mm² ACSR Conductor
Supply & FIxing of GI Barbed Wire for Anti Climbing
Supply & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2 Nos.), anchor plate (200x 200 x 6 )mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply, Laying, installation, testing and commissioning of 100 mm² ACSR Conductor (Dog)
Supply & Fixing of Galvanized Nuts and Bolts
Providing and painting of poles with single coat of red oxide an two coats of Aluminum Paint
Supply,installation, testing and commissioning of 415 V, 3 Phase, 60 KVA Servo Stabilizer oil Cooled (including Oil- 400 Ltrs), Output Voltage Accuracy ± 1%, HV cut-off set. LV cut-off set. O/L trip set.Time delay set Operating mode (auto/manual), Response time of 10 ms, Input Voltage Range from P-P: 173-480 V P-N: 100-277 V including interconnection with system by way of providing thimbles/clamps/Nuts & Bolts etc. (Specification enclosed)
Supply of material & Laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.5 M3 per Pole)
Providing & Laying of Construction of Cement concrete bed 6 x 4 x 6 ft above ground in the ratio mix of mix 1:1.5:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) including curing but excluding the cost of centring and shuttering
Providing & Laying of Centering and shuttering including strutting, propping etc.
Providing & Laying of Cover Shed & foundation for Servo-Stabilizer including wire mesh fencing around the equipment of size upto 8'x4' made out of wire mesh 1"x1"square including fixing in cement 1:2:4 including welding cutting etc. Complete in all respect
Ali Mohammad Baba and Sons
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .