| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAdmitted-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹4.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.1 Cr+₹16.8 L (4.24%)Admitted-Finance | ₹4.1 Cr+₹16.8 L (4.24%) | L2 | Admitted-Finance |
| 3 | L3₹4.2 Cr+₹27.1 L (6.84%)Admitted-Finance | ₹4.2 Cr+₹27.1 L (6.84%) | L3 | Admitted-Finance |
| 4 | L4₹4.3 Cr+₹38.3 L (9.69%)Admitted-Finance | ₹4.3 Cr+₹38.3 L (9.69%) | L4 | Admitted-Finance |
| 5 | L5₹4.5 Cr+₹50.2 L (12.7%)Admitted-Finance | ₹4.5 Cr+₹50.2 L (12.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DALAVAI INFRASTRUCTURE L5 | Anand Shree Infra Reality Pvt. Ltd L1 | DHARMENDRA KUMAR L3 | DAKSHNA MOORTHY D H L6 | SINGADE CONSTRUCTIONS AND INFRASTRUCTURE PRIVATE LIMITED L4 | CHINMAYE CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of Buildings, bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including all lead lift and other incidental charges setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking with in iisc premises the selected stuff for reuse in a radius of iisc and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m. | 920 | Cum | 243 ₹2,63,800.8 | 194.37 ₹2,11,011.2 | 310 ₹3,36,536 | 180 ₹1,95,408 Lowest | 229.22 ₹2,48,841.6 | 550 ₹5,97,080 |
| 2.00 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including including all lead lift and other incidental charges setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of iisc and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m. | 405 | Cum | 270 ₹1,29,033 | 207.96 ₹99,382.95 | 320 ₹1,52,928 | 180 ₹86,022 Lowest | 245.32 ₹1,17,239.4 | 550 ₹2,62,845 |
| 3.00 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead , and lift upto 1.5 to 3m m. Including all lead lift and other incidental charges cost of all labour complete as per specifications. | 1,325 | Cum | 126 ₹1,97,001 Lowest | 127.49 ₹1,99,333 | 160 ₹2,50,160 | 140 ₹2,18,890 | 151.55 ₹2,36,949.75 | 304 ₹4,75,304 |
| 4.00 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | 650 | Sqm | 180 ₹1,38,060 | 99.28 ₹76,147.5 | 100 ₹76,700 | 100 ₹76,700 | 333.77 ₹2,56,002.5 | 35 ₹26,845 Lowest |
| 5.00 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. | 165 | Cum | 4,680 ₹9,11,196 Lowest | 5,200 ₹10,12,440 | 5,700 ₹11,09,790 | 5,000 ₹9,73,500 | 5,080.78 ₹9,89,227.8 | 6,364 ₹12,39,070.8 |
| 6.00 | Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings | 165 | Cum | 450 ₹87,615 | 272.48 ₹53,052.45 | 450 ₹87,615 | 250 ₹48,675 Lowest | 406.46 ₹79,137.3 | 900 ₹1,75,230 |
| 7.00 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curingand all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately )M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | 255 | Cum | 6,300 ₹18,95,670 | 5,799 ₹17,44,919.1 Lowest | 6,350 ₹19,10,715 | 6,000 ₹18,05,400 | 5,955.99 ₹17,92,157.85 | 7,299 ₹21,96,269.1 |
| 8.00 | Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings | 255 | Cum | 1,170 ₹3,52,053 | 309.43 ₹93,108.15 | 900 ₹2,70,810 | 300 ₹90,270 Lowest | 476.44 ₹1,43,361 | 1,050 ₹3,15,945 |
| 9.00 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for Ground floor | 6 | Cum | 5,400 ₹38,232 | 5,785.76 ₹40,963.2 | 4,500 ₹31,860 Lowest | 5,500 ₹38,940 | 5,613.11 ₹39,740.82 | 7,926 ₹56,116.08 |
| 10.00 | Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings | 6 | Cum | 2,205 ₹15,611.4 | 299.29 ₹2,118.96 Lowest | 450 ₹3,186 | 350 ₹2,478 | 449.05 ₹3,179.28 | 850 ₹6,018 |
Tender Value
₹4.3 Cr
EMD Value
₹6.4 L
Closing Date
11 Apr 2024, 3:30 pmClosed
Registrar
IISc Bangalore
Construction of Additional Wing at Chemical Engineering Department at IISc Bangalore
2024_IISC_802055_1
IISc/Tender-CIV-01/2024-25
Open Tender
Civil Works - Buildings
Works
540 days
CCMD
As per Tender Document
2 documents required · 2 mandatory
₹0
₹6.4 L
MS Teams Online
16 Oct 2024
22 Mar 2024
12 Apr 2024
22 Mar 2024
11 Apr 2024
1 Apr 2024
27 Mar 2024
Amount
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead , and lift upto 1.5 to 3m m. Including all lead lift and other incidental charges cost of all labour complete as per specifications.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates.
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curingand all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately )M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for Ground floor
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for First floor
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, sunkens Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for Second floor
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, sunkens Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge.
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Retaianing wall
Providing and removing centering, shuttering, strutting, propping etc.,, for footings, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. for footings For Retaianing wall
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts,Admixtures ,Nitto bond cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesIn COLUMNS (Existing Building column Strengthing)
Providing and removing centering, shuttering, strutting, propping etc.,, for Columns, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. For Columns (Existing Building column Strengthing)
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesIn COLUMNS In Ground Floor
Providing and removing centering, shuttering, strutting, propping etc.,, for Columns, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. For Columns In Ground Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesIn COLUMNS In First Floor
Providing and removing centering, shuttering, strutting, propping etc.,, for Columns, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. For Columns In First Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesIn COLUMNS In Terrace Floor
Providing and removing centering, shuttering, strutting, propping etc.,, for Columns, Pillars, piers, Abutments, posts and struts, square/ rectangular/ polygon in plan including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. For Columns In Second Floor
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates In LINTELS ,Chejjas In Ground Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Lintels and chejjas including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In Ground Floor
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates In LINTELS ,Chejjas In First Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Lintels and chejjas including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In First Floor
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates In LINTELS ,Chejjas In Terrace Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Lintels and chejjas including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In Terrace Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) In BEAMS and plinth beam Ground Floor M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Beams and plinth beam, Beam haunchings, cantilever girders, bressumers not exceeding 1m in depth including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge.
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates In BEAMS First Floor M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Beams, Beam haunchings, cantilever girders, bressumers not exceeding 1m in depth including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In First Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates In BEAMS Terrace Floor M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for sides and soffits of Beams, Beam haunchings, cantilever girders, bressumers not exceeding 1m in depth including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In Terrace Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SLABS,Staircase In Ground Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200mm including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In SLABS,Staircase Ground Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SLABS,Staircase In First Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200mm including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. In SLABS,Staircase First Floor
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SLABS,Staircase In terrace Floor
Providing and removing centering, shuttering to withstand pumping of concrete, strutting, propping etc.,, and removal of formwork for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200mm including cost of all materials, labour with all lead and lift at all levels etc., complete as directed by the Engineer- in-charge. SLABS,Staircase terrace Floor
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)( Cost including welding charges wherever necessary ) In Ground Floor
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)( Cost including welding charges wherever necessary ) In First Floor
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)( Cost including welding charges wherever necessary ) In Terrace Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Terrace Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Second Floor
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.In Ground Floor
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.In First Floor
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.In Second Floor
Providing 15 mm cement plaster on brick / Concrete Block wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In Ground Floor
Providing 15 mm cement plaster on brick / Concrete Block wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In First Floor
Providing 15 mm cement plaster on brick / Concrete Block wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge In Terrace Floor
Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost ofmaterials, labour for fixing complete as per specifications. (length of mesh only be measured for payment – suitable plaster mesh 150mm wide Ground floor
Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost ofmaterials, labour for fixing complete as per specifications. (length of mesh only be measured for payment – suitable plaster mesh 150mm wide First floor
Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost ofmaterials, labour for fixing complete as per specifications. (length of mesh only be measured for payment – suitable plaster mesh 150mm wide Second floor
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In Ground Floor Including water proofing liquid
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In First Floor Including water proofing liquid
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In Second Floor Including water proofing liquid
Extra for providing throating or drip moulding to R.C.C. chejja with plastering as per specifications.in all floors at all levels
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Rough plaster for cladding works) Ground floor
ProProviding 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Rough plaster) First floor
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.In Ground Floor
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.In First Floor
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsIn Terrace Floor
Providing Honne wood wrought and putup for purlins, common rafters and similar work including for door and window cost of materials,plaining trimming,Beeding design as per architectural design and drawing labour, usage charges complete as per specifications. Ground floor
Providing Honne wood wrought and putup for purlins, common rafters and similar work including for door and window cost of materials,plaining trimming,Beeding design as per architectural design and drawinglabour, usage charges complete as per specifications. First floor
Providing Honne wood wrought and putup for purlins, common rafters and similar work including for door and window cost of materials,plaining trimming,Beeding design as per architectural design and drawinglabour, usage charges complete as per specifications. Second floor
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. FLUSH DOOR SHUTTERS 40mm THICK BOTH SIDE TEAK VENEERED. In Ground Floor
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. FLUSH DOOR SHUTTERS 40mm THICK BOTH SIDE TEAK VENEERED. In First Floor
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. FLUSH DOOR SHUTTERS 40mm THICK BOTH SIDE TEAK VENEERED In Terrace Floor
Providing & fixing Vision glass panes withTeak beading for required size as per user requirement , putty and glazing clips in doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge( All floor levels)
Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.
Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent In Ground Floor
Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent In First Floor
Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent In terrace Floor
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. In Ground Floor
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge In First Floor
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge In terrace Floor
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Ceiling AND WALLS Ground floor
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Ceiling AND WALLS In First floor
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Ceiling AND WALLS In Teracefloors
Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per directions of Enginee-in-chrge. In Ground Floor
Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per directions of Enginee-in-chrge. In First Floor
Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per directions of Enginee-in-chrge. In Terrace Floor
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(In second floor)including red oxide coat In Ground floor
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(In second floor)including red oxide coat In First floor
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(In second floor)including red oxide coat In Second floor
Providing and fixing factory made single leaft rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized Isopthalic Gelcoat and on layer of 45 gsm E-Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to RV/TIFAC Composites Design centre Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot.
Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-Glass Chopped Strand Mat (CSM) U.V- stabilized Isopthalic Gelcoat and Isopthalic resin. The thickness of the GRP skin shall not be less than 2.0mm. The doorframe consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement on 6 locations for high screw holding capacity for fixing metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of Paris with fibre reinforcement. Six Numbers of 260mmx25mmx5mm size S shaped M.S. flat hold fast shall be provided with the frame.
Providing & fixing of 3-track x 2-panel sliding windows/Balcony Doors made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -greycolour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system withtouch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made. In Ground Floor (Wooden colour)
Providing & fixing of 3-track x 2-panel sliding windows/Balcony Doors made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -greycolour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system withtouch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made. In First Floor (Wooden colour)
Providing & fixing of 3-track x 2-panel sliding windows/Balcony Doors made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -greycolour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system withtouch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made.In Terrace Floor (Wooden colour)
Providing & fixing of Split glazing ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (50% Ventilators will be with split type glazing) In Ground Floor
Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)In First Floor
Providing and fixing of stick type structural glazing using alluminium extrusions of 63.5mm X 58.00 mm X 2.25mm of 1.73 Kgs /mtr of vertical & horizontal members and 63.5mm X 38.1 X 1.33 mm of 0.759 kg/mtr ,as outer frame with electro Anodized paint coated block finishing ,using 6mm thick imported glass reflective hard coated mirror finish raw glass with all necessary accessories like ultra glass ,silicon sealant of space tape, masking tape ,galvanized anchor bolt ,machine screws, 6mm thick MS angle 50mm X 150mm X 6mm MS galvanized brackets, structural sealant setting locks, fasteners, wall connection etc., complete including cost of ACP panels where required as directed by the Engineer in charge..In First ,second ,terrace floor
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. In Ground Floor
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.In First Floor
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.In Terrace Floor
Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. In Ground,First and Second Floor
Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. for Deck slab, roof trusses and pulins and reapers. In Ground Floor
Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. for Deck slab, roof trusses and pulins and reapers In First Floor
Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. for Deck slab, roof trusses and pulins and reapers In Terrace Floor
Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.
Skylight roof /Door/SSHandrail/Door including Door fiitings with 12mm thick toughened glass including making the joints watertight using suitable sealant etc complete as per directions of the Engineer in charge. (Cost of supporting system will be paid seperatly)
Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. In Second Floor
Providing and fixing 1mm thick M.S. sheet door with outer frame of 45*45*6mm and inner frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.In Terrace Floor
Providing half nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification
Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) for toilet sunkens In Second Floor
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)In Second Floor and terrace floor
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing & fixing of Butch work /Sand stone cladding tiles of approved shade & size k on 12 mm thick cement plaster 1:3 and jointed with the required groutting material over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately ) using butch work tiles of approved make and size including cost of materials, labour, complete as per specifications. The rate shall be inclusive of all taxes and GST etc,. and work shall be carried out as per the technical specifications and instructions of Engineer in charge -
Providing and fixing 40mm thick machine polished Granite Stone Slab as per the direction of the Engineer In charge.(Black granite) including nosing
Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm (Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for:Cutting asphalt Road surface by Machine cutting to demarcate the trench width of the surface.
Demolishing cement concrete manually / mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Demolishing stone masonry in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge.In cement mortar.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer- in-charge. Of area beyond 3 Sqm.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge.(Loading , unloading and dispoasl of debris outside the iisc campus up to Bbmp limits)
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge.Asbestos cement sheet
Labour charges for works of loading and unloading works, tank shifting and for Cleaner
Tractor-Trolley for debris shifting and shifting of soil, and materials etc
Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent In Ground Floor (Ramp Flooring) Ruby red/Laka red
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland / Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.0 M depth & SFRC cover & frame.
Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland / Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia Circ. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.2 M depth & SFRC cover & frame.
Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland / Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia Circ. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.5 M depth & SFRC cover & frame.
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore.
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore.
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Providing and Placing on terrace (At all floor levels)polyethylene water storagetank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Providing and fixing nahini trap.110mm
Providing and fixing grating of VIKING Brand (Model No.ART39594CT)-125mm
Providing,Fixing,Testing and Commissioning of white vitreous Counter Wash Basin/Bottom Wash Basin:605 x 410 x 200 mm(Model No. FNS-WHT-40701) installed with marble/Granite Counter and brackets,Pillar Cock(Model No.ALI-85021),32mm Size Full Thread with 80mm Height Waste Coupling (Model No.ALI-705),Bottle Trap 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange(Model No.ALD-769L300 x 190),Angular Stop Cock with Wall Flange(Model No-FUS-29053).The Works shall include cutting and making good the walls & floors.
Providing, fixing, testing and commissioning of white colour vitreous china large flat back lipped urinals of size (MM) 480 x 300 x 740 mm, with one set robo automatic urinal flushing system, (with 220v power / battery operated) including electric control system and motorised solenoid valve, CP flush pipe with CP spreaders, 32mm dia CP brass bottle trap, etc., complete including cutting & making good the walls & floors. (Model No.-URS-WHT-13255) and Sensor Mini Concealed Type Flushing Valve(Model No-PRS-073)
Providing, fixing, testing and commissioning of SS Sink -Nirali(915 x 460 mm) stainless steel single bowl and Single Drain board made of 18 gauge sheet, waste coupling,Bottle Trap and Sink Cock Wall Mounted Swing Spout(Model No-FLR-CHR-5347N),Bib Cock With Wall Flange(COP-CHR-037PM) etc, complete.
Providing, fixing, testing and commissioning of Wall Hung WC with PP soft close seat cover, Hinges, Accessories Set,Size: 365x545x360 mm (Model No-CNS-WHT-961SPP) with Single piece Slim Concealed Cistern with Wall Mounting Frame, Installation Kit and “P-Type” Drain Pipe Connection Set for Wall Hung WC (Model No-JCS-WHT-2400W) (with Flush Control Plate- Model No-JCP-CHR-152415) and Health faucet HandShower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook(Model No-ALD-573),One Set of Angular Stop Cock with Wall Flange(Model No.-FUS-29053) etc, complete.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing Soap Dispenser with Glass Bottle(Model No.-AKP-35735P) Jaquar Make or equivalent Make.
Providing and fixing Towel Ring Round Flange, Jaquar Make,(Model No.ACN-1121BN)
Providing and fixing Toilet Roll Holder with Stainless Steel Flap,Jaquar Make(Model No. AKP-35753PS)
Providing and fixing Infrared Hand Dryer 1150 W-Jaquar Faucets(Model No. HDR-SSF-AK2803D)
Providing and fixing Curved Shaped Urinal Partition With frosted glass-8mm/10mm,Jaquar Make(Model No. JCR-CHR-110UC450X)
Providing and fixing Bib Cock with Wall Flange-Jaquar Make(Model No. VGP-CHR-81037)
Providing and fixing,testing and commissioning of Corner Wash Basin Hindware Make (Model No. VGP-10055) With Pillar Cok (Model No.F520001CP),Angle Stop Cock with wall flange,32mm dia CP waste coupling,32mm dia CP brass bottle trap.The works shall include cutting and making good the walls & floors.
Providing,Supplying and fixing Superior quality 6mm thick mirror with aluminium frame all round beeding and 6mm thick plywood backing including cost of Screws nail clamps for fixing etc., complete as per direction.
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work- Exposed on wall (25mm nominal dia Pipe)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work- Exposed on wall (32mm nominal dia Pipe)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work- Exposed on wall (40mm nominal dia Pipe)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work- Exposed on wall (50mm nominal dia Pipe)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in Charge.External Work-Terrace Header Line (65mm nominal dia Pipe)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work,including cutting Chases and making good the wall etc.(15 mm nominal dia pipes)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work,including cutting Chases and makinggood the wall etc.(20 mm nominal dia pipes)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work,including cutting Chases and making good the wall etc.(25 mm nominal dia pipes)
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work,including cutting Chases and makinggood the wall etc.(32 mm nominal dia pipes)
Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary a)19/20 mm dia 2 mm thick
b) 25 mm dia 2 mm thick
c) 32 mm dia 2.5 mm thick
d) 40 mm dia 2.5 mm thick
Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. a) 19/20 mm dia 2 mm thick
b) 25 mm dia 2 mm thick
c) 32 mm dia 2.5 mm thick
Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. a) 75 x 75 x 65 mm
b) 100 x 75 x 65 mm
c) 135 x 75 x 65 mm
d) 180 x 90 x 65 mm
e) 200 x 90 x 65 mm
f) 135 x 160 x 65 mm
g) 200 x 200 x 65 mm
Supplying and fixing PVC/metal conduit Deep junction box a) 19/20 mm deep Junction box
b) 25 mm deep Junction box
c) 32 mm deep Junction box
Supplying And Fixing Metal Fan Box with Round Hook.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point upto 3m from tapping point to out let via switch
b) Medium point above 3m upto 6m from tapping point to out let via switch
c) Long point above 6m upto 10m from tapping point to out let via switch
d) Three outlet in a row, above 6m upto 10m from tapping point to out let via switches
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a) 1.5 mm2
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. a) 3C x 2.5 mm2
b) 3C x 4 mm2
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 3 Way
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. a) 3 Module
b) 4 Module
c) 6 Module
d) 8 Module
e) 12 Module
f) 18 Module
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. a) 6A One Way Switch
b) 6A Two Way Switch
c) 6A Three Way socket
d) Stepped Fan Regulator Two Module
e) 16A One Way Switch
f) 6/16A Universal Socket
g) TV/Telephone Socket
Supplying and fixing of metal clad industrial plugs and sockets. 20A, 2pole+earth 250V Plug for AC
Supplying and fixing of 20A, 240volts SPN industrial type scoket outlet with 2 pole and earth, metal enclosed plug top along with 20A C- curve, SP MCB in sheet steel enclosure on surface or in recess, with chained metel cover for the socket outlet and complete with connections, testing and commissioning etc, as required
Supplying and fixing of 30A, 415volts TPN industrial type scoket outlet with 4 pole and earth, metal enclosed plug top along with 30A C- curve, TP MCB in sheet steel enclosure on surface or in recess, with chained metel cover for the socket outlet and complete with connections, testing and commissioning etc, as required
Supplying and fixing of 12 way (4 + 36), Double door, surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . With provision for 100 MCCB as incomer and SP/TP MCB's as outgoing.
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. a) 100 A 25 kA, FP
b) 250 A 35 kA, FP
Supplying and fixing regular Double Door Horizontal / Vertical MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. a) 6 Way SP & N
b) 8 Way SP & N
c) 16 Way SP & N
d) 4 Way TP & N
e) 6 Way TP & N
Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. a) 16A-25A 2 pole
b) 32-40A 2 pole
c) 32-40A 4 pole
d) 63 A 4 pole
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. a) 32-40 A 4 pole
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 400 A 4 x 50 x 10 mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. a) 50 x 50 x 6 mm
b) 75 x 75 x 6 mm
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 16 SWG
Surge protection devices type-2 SPD 3Phase + Neutral 40KA, 440V with safety reserve pluggable device, auxiliary contact quick safe technology and bottom wiring.
upplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6089. a) 16 - 32 A SP
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. a) 12" Sweep (300 mm)
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. a) 48" Sweep (1200 mm) Regular model
Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. a) 400 mm Sweep (Wall mounted fan)
Supplying and drawing UTP-CAT 6A LAN cable.
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 Pair
Supplying & Fixing of switch mounting rack with power manager & Cable manager. a) 4U with 450mm depth
b) 9U with 450mm depth
Supplying & Fixing of Power strip for Network rack power point.
Supplying & Fixing of exhaut fan for 4U and 9U rack
Supplying & fixing of Network Switches, 48 Port Gigabyte (manageable) - L2 Network switch
Supplying & fixing of 48 Port 10/100/1000 Switch
Supplying & fixing of I/O socket with back box a) Single I/O
b) Double I/O
Supplying & Fixing of ... ms Cat 6 Patch Cable a) 1 m
Supplying & Fixing of Patch panel for LAN cabling.48 Port 10/100/1000 patch panel
Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 50 pair
Supplying & Fixing of Wifi Extender
Supplying, erecting, testing & commissioning of ON-LINE UPS with 3phase input and output system suitable for operation on 415V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. (3phase input and 3 phase output) a) 20 kVA ON LINE UPS
Supplying, installation, testing & commissioning of 12V DC, 100 AH capacity batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.
MS Rack and DC interlink accessories set (cable,lugs, etc., as required).
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED light fitting 1 x 2' - 9/10 W
b) LED light fitting 1 x 4' - 20/22 W
Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @50/60Hz & Power factor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. a) LED square or round down light 15-18W
Supplying and fixing of surface / recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED modular down light 2'x2' /1'x4' 34-36 W
Earthing with GI earth plat 600mm x 600mm x 6mm thick including accessories, providing masonry enclosed with cover plat having locking arragement and watering pipe of 2.7 Meter long etc . with charcoal/ chok and slat as required .
Earthing with copper earth plat 600mm x 600mm x 3mm thick including accessories, providing masonry enclosed with cover plat having locking arragement and watering pipe of 2.7 Meter long etc . with charcoal/ chok and slat as required .
Supplying and laying 25mm x 5mm GI strip at 0.50 mtrs below ground as strip earth electrode, including connction/ termination with GI nut, bolt, spring , washer etc as required ( jointing shall be done by overlaping and with 2 sets of GI nuts bolt and spring whaser spaced at 50mm )
Proving and fixing 25mm x 5mm copper strip on surface or in recess for connections etc . As required.
Proving and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath aluminium armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 a) 3.5C x 240 sqmm, (30 GI Strips - 4 x 0.8 mm)
b) 3.5C x 25 Sqmm, (12 GI Strips - 4 x 0.8 mm)
c) 4C x 16 Sqmm, (11 GI Strips — 4 x 0.8 mm)
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. a) Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminum lugs for following size of pvc insulated and pvc sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 core 240 sqmm
b) 3.5C x 25 Sqmm
c) 4C x 16 Sqmm
Supplying and installing follwing size of perforated painted with powerder coating MS Cable tray with perporation not more than 17.5%, in convenient section joint with connector suspended from the ceiling with MS suspenders including bolts and nuts, painting suspenders etc as required. a) 150mm width x50mm deapth x 1.6mm Thickness
b) 300mm width x50mm deapth x 1.6mm Thickness
c) 450mm width x50mm deapth x 2.0 mm Thickness
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)
Supply and Fixing LED light fitting 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Part-B : Fire Alaram System Supply, installation, testing and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126 /240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system including battery charger and public address system interface system software, all as specified and or required etc., complete . (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. Make: Advanced (UK), Argus,( Uk) Simplex, Notifier 2 Loop Panel
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in –10°C to +55°C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/ Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54.
Supply, install, test and commissioning of Analogue addressable Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, designed for IP44 requirements and approved to operate in –10°C to +55°C temperature, complies with the essential requirement of the EMC Directive to be supplied with Barriers, Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS.
Supply, install, test and commissioning of analogue addressable Smoke Sensor detector and standard base (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54.
Supply, install, test and commissioning of analogue addressable dual heat detector and standard base, It shall have multiple modes with min five different heat sensitivity adjustment from 57 Degree to 90 Degree for static response while working on Rate of Rise response. 360° Visible Tri-coloured led for Normal, Fault and alarm condition, addressing shall be by means of Soft addressing or dip switches or decade switches, or suitable punched cards. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: UL/VDS /EN54.
Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in –10°C to +55°C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54.
Supply, installation, testing and commissioning of Short Circuit Isolator / fault isolator module all as specified and/or directed etc., complete
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
"FIRE EXIT " Autoglow ,fixed on the exit door(SINGLE SIDE)
"EXTINGUISHER Signages" - Autoglow, with suspension chains
"EMERGENCY EXIT "Autoglow, with suspension chains(SINGLE SIDE)
"EMERGENCY EXIT "Autoglow, with suspension chains(DOUBLE SIDE)
"MCP Signages" - Autoglow, with suspension chains
Preparation of drawing and providing, Autoglow Fire escape route map in clear acrylic glass and required glass studs supports etc. Indicating direction, Key plan, contact numbers etc. (The sample of the same need to be presented for approval before execution)…. (Maximum size of the board A2)
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply and installation in position of ABC Powder based MAP 50, 6Kg Fire Ex tinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, CE Marked
Part-C : Lift Design, supplying, erecting, testing and commissioning of Passenger cum Goods lift 1000 Kg (Minimum) 3 stop (G+2), with speed of 1 mtr. per second, variable voltage variable frequency drive, without machine room & Without gear for the available well size, min. one meter, center opening access, operating at 415 V 3 phase 50 cycles AC supply, Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan, central opening door operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with maintenance free batteries, voice announcing in regional/national languages, Braille button inside the car & at each landing complete complying with relevant IS codes & requirement of local authorities, getting approval of concerned state/ central government authorities including 12 months guarantee with free maintenance and replacements of equipment & spares. scaffolding and minor civil works like fixing of guide rail, shaft reduction channel, pit ladder, counterweight etc., Refer: Annexure for Lift detailed specifications
Design, supplying, erecting testing and commissioning of 10 passenger lift, 3 stop (G+2) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille button inside the car & at each landing complete complying with relevant IS codes & requirement of local authorities, getting approval of concerned state/ central government authorities including 12 months guarantee with free maintenance and replacements of equipment & spares. scaffolding and minor civil works like fixing of guide rail, shaft reduction channel, pit ladder, counterweight etc., Refer: Annexure for Lift detailed specifications
Part-D : Pump and Control Accessories Supplying, installation, testing and commissioning of Submersible Pump Set horizontal type of 150mm dia suitable for sump /open well and confirming to IS 8034-2000; 3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. (1 working +1stand by ) 5.00 HP - 245 LPM @ 56 m = 4 STG Outlet Dia - 2.50”
Supply, installation,testing and commissioning of Automatic water level control suitable for 5.0 HP motor from sump to over head tank including all accessories (1 working +1stand by ) (Sensor/realy, contactor, MCB, suitable float & wire connection, etc. as required).
CHINMAYE CONSTRUCTIONS
DHARMENDRA KUMAR
SINGADE CONSTRUCTIONS AND INFRASTRUCTURE PRIVATE LIMITED
DALAVAI INFRASTRUCTURE
DAKSHNA MOORTHY D H
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_843090.xls
BOQ • 0.62 MB
CivilDrawings.pdf
Additional Documents • 6.13 MB
TenderDocumentChemEngg.pdf
Tender Documents • 2.12 MB
ElectricalDrawings.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .