GEMC-511687758231427
Awarded to WARSI MEDICO SYSTEMS AND SERVICES
₹7.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| HORIZONTAL AUTOCLAVE | WARSI IMPEX | - | 1 NOS | ₹7.3 L | 729,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.3 LQualified Make: Esteem
Model: ESTA-108 10 122 KATRA MADARI KHAN MOTI KATRA AGRA AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | Make: Esteem
Model: ESTA-108 | ₹7.3 L | L1 | Qualified MSE, Category: General |
| 2 | ₹7.3 L 10 122 KATRA MADARI KHAN MOTI KATRA AGRA AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | - | ₹7.3 L | - | - |
| 3 | Not yet disclosed by govt. Qualified Make: WARSI
Model: WARSI IMPEX | Make: WARSI
Model: WARSI IMPEX | - | - | Qualified MSE |
| 4 | Not yet disclosed by govt. Disqualified Make: macro
Model: MAC-HORI-REC-SS-HD | Make: macro
Model: MAC-HORI-REC-SS-HD | - | - | Disqualified MSE |
| 5 | Not yet disclosed by govt. Disqualified Make: YATHERM
Model: Yatherm Scientific & Clavex 900 | Make: YATHERM
Model: Yatherm Scientific & Clavex 900 | - | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Sept 2018, 10:00 amClosed
Steam Sterlizer ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use
conforming to IS: 3829(part 1)/1999
fitted with Silicon door gasket( expansion type). Steriliser Chamber size (L x W x H): 1500 mm x 600 mm x 900 mm
Electric load of the unit shall be 36 KW. HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use
Electric load of the unit shall be 36 KW. Steam supply to Steriliser From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion Direct Steam Operation from an external source
From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 1/6 heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)] wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)]
Built-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system)
it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber
Jacket
Door
Door Ring and shall be made of SS 316 or SS 316L SS 304
SS 316 or SS 316L Type of control Manual through indt. switch based Manual through indt. switch based
Automatic: MICROPROCESSOR CONTROLLED
WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES * Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the Yes Yes
No 2/6 steriliser: Provision of Lock on Steriliser Chamber door: Manual Lock Manual Lock
Automatic Lock
Manual and Automatic Locks
both Installation The site ready for installation equipped with water supply
electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. * Type of Door: Radial Type Sliding type
Hinged type
Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature
Time and date
Alarm indicator
Low water indicator Chamber Temperature
Cycle number
Batch Number
Low water indicator Print facility for record generation of dates
time
load
identification number and operating parameters (temperature and holding time etc): Yes
port given to connect an external Printer Unit Yes
port given to connect an external Printer Unit
Yes
by an inbuilt printer unit Warranty Period 5 3
5 (or higher) No of Doors in Steriliser 1 1
2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is true true
false 3/6 available (If Yes
to be furnished by Seller to Buyer on demand) for the offered product? Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: Keyboard interface Keyboard interface
Touch screen interface
NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis true true
false Air removal from Sterilisation chamber
after loading the steriliser
by on for more pressure/vacuums pulsing for proper steam penetration YES * Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Not available Yes
with Microprocessor controlled
with Manually controlled Shredder unit
Not available Material: Shredder parts; SS 304 SS 304
SS 316 or SS 316L Power of Motor used for Shredding NA
no integrated Shredder unit offered Must be of >= 2 HP
>= 1000 RPM
220 V
50 HZ AC motor
and able to deal with shredding of bio medical waste land as per Steriliser capacity
NA
no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0
2 (or higher) Long Handle: 1 0
1 Sterilisation Carriages 1 0
1
2 (or higher) Pull out Trays/Tanks 2 0
2 Floor loading carts 2 0
2 (or higher) 4/6 Transfer carriages: 1 0
2 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indrapal Yadav 110033
BJRM Hospital
E- Block
Jahangir Puri 1 15
535998
GEM/2018/B/76022
GeM Contract
Steam Sterlizer ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use
GeM Contract
15 days
Delhi; North Delhi
PRODUCT
Awarded to WARSI MEDICO SYSTEMS AND SERVICES
₹7.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| HORIZONTAL AUTOCLAVE | WARSI IMPEX | - | 1 NOS | ₹7.3 L | 729,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Steam Sterlizer ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use | - | - | - |
| conforming to IS: 3829(part 1)/1999 | - | - | - |
| fitted with Silicon door gasket( expansion type). Steriliser Chamber size (L x W x H): 1500 mm x 600 mm x 900 mm | - | - | - |
| Electric load of the unit shall be 36 KW. HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use | - | - | - |
| Electric load of the unit shall be 36 KW. Steam supply to Steriliser From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion Direct Steam Operation from an external source | - | - | - |
| From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 1/6 heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)] wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)] | - | - | - |
| Built-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system) | - | - | - |
| it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber | - | - | - |
| Jacket | - | - | - |
| Door | - | - | - |
| Door Ring and shall be made of SS 316 or SS 316L SS 304 | - | - | - |
| SS 316 or SS 316L Type of control Manual through indt. switch based Manual through indt. switch based | - | - | - |
| Automatic: MICROPROCESSOR CONTROLLED | - | - | - |
| WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES * Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the Yes Yes | - | - | - |
| No 2/6 steriliser: Provision of Lock on Steriliser Chamber door: Manual Lock Manual Lock | - | - | - |
| Automatic Lock | - | - | - |
| Manual and Automatic Locks | - | - | - |
| both Installation The site ready for installation equipped with water supply | - | - | - |
| electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. * Type of Door: Radial Type Sliding type | - | - | - |
| Hinged type | - | - | - |
| Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature | - | - | - |
| Time and date | - | - | - |
| Alarm indicator | - | - | - |
| Low water indicator Chamber Temperature | - | - | - |
| Cycle number | - | - | - |
| Batch Number | - | - | - |
| Low water indicator Print facility for record generation of dates | - | - | - |
| time | - | - | - |
| load | - | - | - |
| identification number and operating parameters (temperature and holding time etc): Yes | - | - | - |
| port given to connect an external Printer Unit Yes | - | - | - |
| port given to connect an external Printer Unit | - | - | - |
| Yes | - | - | - |
| by an inbuilt printer unit Warranty Period 5 3 | - | - | - |
| 5 (or higher) No of Doors in Steriliser 1 1 | - | - | - |
| 2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is true true | - | - | - |
| false 3/6 available (If Yes | - | - | - |
| to be furnished by Seller to Buyer on demand) for the offered product? Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: Keyboard interface Keyboard interface | - | - | - |
| Touch screen interface | - | - | - |
| NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis true true | - | - | - |
| false Air removal from Sterilisation chamber | - | - | - |
| after loading the steriliser | - | - | - |
| by on for more pressure/vacuums pulsing for proper steam penetration YES * Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Not available Yes | - | - | - |
| with Microprocessor controlled | - | - | - |
| with Manually controlled Shredder unit | - | - | - |
| Not available Material: Shredder parts; SS 304 SS 304 | - | - | - |
| SS 316 or SS 316L Power of Motor used for Shredding NA | - | - | - |
| no integrated Shredder unit offered Must be of >= 2 HP | - | - | - |
| >= 1000 RPM | - | - | - |
| 220 V | - | - | - |
| 50 HZ AC motor | - | - | - |
| and able to deal with shredding of bio medical waste land as per Steriliser capacity | - | - | - |
| NA | - | - | - |
| no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0 | - | - | - |
| 2 (or higher) Long Handle: 1 0 | - | - | - |
| 1 Sterilisation Carriages 1 0 | - | - | - |
| 1 | - | - | - |
| 2 (or higher) Pull out Trays/Tanks 2 0 | - | - | - |
| 2 Floor loading carts 2 0 | - | - | - |
| 2 (or higher) 4/6 Transfer carriages: 1 0 | - | - | - |
| 2 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indrapal Yadav 110033 | - | - | - |
| BJRM Hospital | - | - | - |
| E- Block | - | - | - |
| Jahangir Puri 1 15 | - | - | - |
Exempted
2 Mar 2019
29 Sept 2018
contract_GEMC-511687758231427.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_535998.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .