| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹25.0 L+₹2.8 L (12.4%)Rejected-Finance C 49 B RADHA GARDEN MEERUT 250001 UP | MEERUT | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹26.5 L+₹4.3 L (19.2%)Rejected-Finance MURSTEY COLONY PLOT NO 16 LEH 194101 LADAKH | LEH LADAKH | LADAKH | 194101 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹27.3 L+₹5.1 L (22.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹27.9 L+₹5.7 L (25.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹38.4 L
EMD Value
₹77,000
Closing Date
9 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
SPL REPAIR TO BLDG NO P 175 AT LSRC UNDER GE 865 EWS AT LEH
2022_MES_568366_1
865/EWS(NIT-94)/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹77,000
Yes
23 Feb 2023
10 Dec 2022
17 Jan 2023
10 Dec 2022
9 Jan 2023
25 Dec 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down shutter of any description exc 1 sqm but not exc 2 sqm each complete all as specified and directed by Engr-in-Charge.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as directed by Engr-in-Charge.
S&F for 35mm thick 2nd class hard wood plain framed factory made paneled shutters (any number of panels) with panels of 12mm thick veneered plywood commercial face complete all as directed by Engr-in-charge.Make as per PS.
S&F for 35 mm thick 2nd class hard wood plain framed factory made glazed and skeletion shutter shutters , open rebated and prepared to receive glass , gauze etc (without sash bars) edges of framing plain , chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR part I, Section 8 , clause 8.24(a) supplied and fitted to chowkats , complete all as specified and directed by Engr-in-charge.Make as per PS.
S&F for 30 mm thick 2nd class hard wood plain framed factory made glazed and skeletion shutter shutters , open rebated and prepared to receive glass , gauze etc (without sash bars) edges of framing plain , chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR part I, Section 8 , clause 8.24(a) supplied and fitted to chowkats , complete all as specified and directed by Engr-in-charge.Make as per PS.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung/top hung type without sash,aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long (1 Nos) hinges type B-21 100mm long (2 Nos) suitable handle (1 Nos) etc. complete all as specified and directed By Engr-in-Charge.
S&F of powder coated aluminium grill of 6 mm thick design as approved with F/U type channel for windows complete all as specified and directed by Engr-in-Charge.
M&L for plain sheet glass 4.80mm thick ordinalry quality and glazing with oil putty or wooden beads in square or fixed with aluminium section including rubber beads not exc 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
S&F in repair 100mm mild steel medium weight , cold rolled, butt hinges of extruded section complete all as specified and as directed by Engr-in-Charge.
S&F in repair Aluminium, anodized, barrel tower bolts, ISI Marked, of extruded section 150 mm long, complete all as specified and directed by Engr-in-Charge.
S&F for Aluminium, anodized, barrel tower bolts, ISI Marked, of extruded section 100 mm long, complete all as specified and directed by Engr-in-Charge.
S&F for 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed by Engr-in-Charge.
S&F in repair 150 mm size extruded aluminium alloy, anodised handles, fabricated type complete all as specified and directed by Engr-in-Charge.
S&F in repair 100 mm size extruded aluminium alloy, anodised handles, fabricated type complete all as specified and directed by Engr-in-Charge.
M&L for Mild Steel Bands, nut abd bolts, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engr-in-Charge.
Material & labour PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in hold fast , bed block and like complete all as specified and as directed by the Engr-in-Charge.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks, and setting in cement mortar 1:6 all as Specified by Engr-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick rendering in cement mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick rendering in cement mortar 1:4 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for 5 mm thick rendering on ceiling finished even and smooth without using extra cement in cement mortar 1:3 complete all as specified and directed by Engr-in-Charge.
M&L for two coats cement base paint on newly plastered surfaces of wall including preparation of surfaces including curing before and after applying each coat complete all as specified and directed by Engr-in-Charge.
M&L for preperation of new concrete /plastered surface of wall any description including 3mm thick wall care putty applaying two coat of distemper oil emulsion over a coat of primer complete all as specified and as directed complete all as specified and as directed by Engr-in-Charge.
M & L for Preparing new or previously untreated plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer on ceiling surfaces of any description complete all as specified and directed by Engr-in-Charge.
M&L for preperation of new or previously untreated wooden surface any description of any description over 10cm in width or girth and applying two coat of synthetic enamal paint over a coat of Pink primer complete all as specified and as directed complete all as specified and as directed by Rngr-in-Charge.
M&L for preperation of old Steel / CGI Sheet surface any description over 10cm in width or girth and applaying one coat of synthetic enamal paint complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old painted wooden surfaces of any description, not other wise described, over 10 cm width or girth and applying one coat of synthetic ememal paint complete all as specified and directed by Engr-in-Charge.
M&L for old decorated surfaces o wall by complete removing of existing treatment and applying roller application two coats of oil emulsion distemper incl applying 3 mm thick brila/JK wall care putty over a coat of primer of surfaces to be smooth and filling holes, cracks etc complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated plastered/unplastered surfaces of walls of any description by washing, rubbing down and applying two coat of cement base paint complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated plastered/unplastered surfaces of walls of any description by washing, rubbing down smoke, moulds,and efforescent salts and reoving of oil greasy spots and applying two coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for two coats of white wash on old surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and as directed by Engr-in-Charge.
M&L for plain sheet glass 4mm thick ordinalry quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for vitrified tilees light shade of 10 mm thick (square/rectangular) polished bright, area of tiles not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thich screed bed or bedding layer in cement mortar 1.4 compelte all as specified and directed by Engr-in-Charge. Make as per PS.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 and nexc .18 sqm in floor etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match the 15mm thick screed bed with CM (1:6) laying floor tiles complete all as specified and directed by Engr-in-Charge.
M&L Glazed ceramic coloured tiles in vertical surfaces (350 X 250X7mm ) / (450x350x7mm) /(300x200x7) thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over rendering 10mm thick in CM (1:4) , for dado/skirting tiles.complete all as specified and as directed by the Engr-in-charge. Make as per PS.
Demolition of stone slab laid bedded and pointed in mortar and tiles of any description as specified and directed by Engr-in-Charge.
M&L Machine cut pre polished Kota stone slab flooring 20-25 mm thick over 20mm thick cement screed bed or bedding layer in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for 20 mm thick granite stone (any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting, etc and screed bed with CM (1:4) 20mm thick laying floor tiles complete all as specified and as directed by Engr-in-Charge.
Demolition of un reinforced cement concret as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement including making proper joints as per specification at an interval of 3m and change of direction complete all as specified and as directed by Engr-in-Charge.
Taking up or down 20 mm bore steel tubing and connections and set aside for reuse or removal to store complete all as specified and directed by Engr-in-Charge.
Taking up or down 25/32 mm bore steel tubing and connections and set aside for reuse or removal to store complete all as specified and directed by Engr-in-Charge.
S&F 20 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&F 25 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&F in repair Viterous china wash basin, white flat back size 630x450mm including waste coupling CP 32mm dia and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1, fixed complete all as specified and as directed by Engr-in-Charge. MAKE: CERA/HINDWARE/PARRYWARE
S&F in repair sinks stainless steel with drainage board made of 1.0 mm thick kitchen or laboratory with plugs, washers and wastes; including fixing contilever brackets and connecting union to pipe overall size 495mm x 420 mmmm bowl size 410mm x 330mm x 160mm, complete all as specified. Make : NIRALI/NEELKANTH/JAYNA/SILVERSHINE/JINDAL
S&F in repair 15mm bore, chromimum plated brass, Bib tap screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15mm bore, piller tap chromimum plated fancy type high pressure with or without letter Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. MAKE: PARYAG/POLYTUF/SUPREME
S&F in repair 15 mm bore, fancy type Stop valve/cock, cast copper alloy, screwed down, high pressure with handle, chromium plated, screwed end for iron pipe or for union and fixed, complete all as specified by Engr-in-Charge.
S&F in repair, 15 mm bore, PVC connection pipe 450 mm long with PTMT nuts at both ends complete all as specified by Engr-in-Charge.
S&F in repair Gratings 125 mm dia with waste holes of PTMT complete all as specified and directed by Engr-in-Charge.
S & F in repair towel rail 600mm long of aluminum 20 mm dia, D type fixed with and including chrominium plated brass screws and wooden/plastic cleatscomplete all as specified and directed by Engr-in-Charge.
S&F Rotational moulded polyethylene water storage tank, inner and out white, two layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I of Capacity of 1000 litr each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, including taking down of old broken water tank complete all as specified and as directed by Engr-in-Charge.
S&F 25 mm bore ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in PP-R 25mm bore Gate valve (with brass ferrule as per site reqirement antimicrobial fusion welded having thermal stability for hot & cold water supply . complete all as specified and directed by Engr-in-Charge. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&Fin Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, incl bedding with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate complete all as specified and as directed by Engr-in-Charge. Make: Cera/Hindware/Parryware
S&F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete, all as specified and as directed by Engr-in-Charge. MAKE: Cera Model Combiflush twin flush as per Cat Part No. B1020101 (Old Cat Part No 2603) or equivalent in HINDWARE/PARRYWARE
S & F in 32 mm waste coupling brass chromimum plated for sink and wash hand basin (Half or full threaded ) (Minimum Weight 45 grams) complete all as specified and directed by Engr-in-Charge.
Dismantling of upto 150 mm dia cast iron drain pipes, salt glazed ware, AC or reinforced concrete including fitting, jointed in cement mortar or taking out from trenches complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bent 110 mm bore fixed to pipes of any description complete all as specified and directed by Engr-in-Charge.
M&L for 110 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge. MAKE: SUPREME/ASHIRWAD/FINOLEX/ SFMC/ASTRAL
S&F PVC (SWR) vent cowl 110 mm bore fixed to pipes of any description complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC SWR floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete type B1 in cement concrete (1:2:4), 20 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
Demolition of un reinforced cement concret as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete (Nominal mix) 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engineer-in-Charge.
S&F mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
M&L for use & waset of form work for rough finished to sides and soffits of suspended slabs such as roof, floor slabs, beams, roof beams, columns concrete surfaces complete all as specified and directed by Engr-in-Charge.
M&L for french polishing on new or old untreated surfaces of wooden one or more coats of any description width or girth including cleaning and preparing the surfaces including a coat of wood filler and laker complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed by Engr-in-Charge
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 82.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 82.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 82.00 here-in-before but using 4 Sqmm complete all as specified and directed by Engr-in-Charge.
S&F in replacement for lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
S&F in replacement for switch piano flush type one way single pole 5/6 Amp 240 volts complete all as specified and directed by Engr-inCharge.
S&Fin replacement for switch socket combination 2 in 1, 5 pin, 5/6 Amps flush type universal complete all as specified and directed by Engr-in-Charge.
S&Fin replacement for switch socket combination 2 in 1, 5 pin, 6 Amps, 15 Amps, 230 volts flush type universal complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 of Legrand (Ekinoxe) or equivalant make as per PS.
Supply and fixing in replacement of MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 of Legrand (Ekinoxe) or equivalant make as per PS.
Supply and fixing in replacement for MCB, SPN, 63 Amps, 'C' series, 240 V A/C ISI marked complete all as specified and as directed by Engineer-in-Charge.Make as per PS.
Supply and fixing in replacement for MCB, SPN, 40 Amps, 'C' series, 240 V A/C ISI marked complete all as specified and as directed by Engineer-in-Charge.Make as per PS.
Supply and fixing for MCB single pole 6 to 32 Amps, 'C' series, 50 Hz, 240 V A/C complete all as specified and directed by Engineer-in-Charge.Make as per PS.
S&F in repalcement and testing of LED Luminare 600mm x 600 mm, 35/36 watt, 220 V, AC recessed type with high efficeiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge
Supply and fixing of exhaust fan/Air ciculator, PVC body, AC single phase 230 volts of size 450 mm sweep with blades and frame and louvers complete all as specified and as directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, t complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Sub main wiring with two run of 6 Sqmm (2x6sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6 Sqmm (1x6Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6 sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB
S&F in repalcement decorative ultra slim round profile LED lighting fixtures with extruded polycarbonate, environmental frendly energy efficient ready to use pack 18/20 Watt LED 6000K with connections 3 core copper wire from ceiling rose to fitting with complete accessories complete all as specified and directed by Engr-in-Charge. Make : HAvells/Bajjaj/CG or equivalant make in PS.
S&F in repalcement decorative ultra slim round profile LED lighting fixtures with extruded polycarbonate, environmental frendly energy efficient ready to use pack 1x9W/1x10 Watt LED with connections 3 core copper wire from ceiling rose to fitting with complete accessories complete all as specified and directed by Engr-in-Charge. Make : HAvells/Bajjaj/CG or equivalant make in PS.
Supply and fixingin replacement of sheet mental enclosure with 20 Amp, 240 V, socket plug top and MCB complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement and testing connecting street light LED type suitable for working on 230 Volts, 50 Hz, AC of 60 watts complete including all electrical connection complete all as specified and directed by Engr-in-Charge.
S&F street light brackets in repalcement 1.50 mtr long, 40 mm bore, GI light grade with MS clamps complete all as specified and directed by Engr-in-Charge.
S&F PVC insulated, PVC sheathed copper conductor cable 1.5 Sqmm 3 core complete all as specified and directed by Engr-in-Charge
S&F in repalcement of flood light and testing of LED 70 W, 230 V, AC out door type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
M/S Praveen Kumar and Sons
M/S SHAMSHER ALI SUFI
M/S SHUBHAM ENGINEERS & BUILDERS
PARIDHI CONSTRUCTION
Mehar Enterprises
R B TRADERS
M/S INDUS HIMALAYAN EXPLORERS
SUMEET TRADING CORPORATION
M/S MUNEER HASSAN AKHON
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .