Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68,450Accepted-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | L1 | Accepted-Finance LOWEST | |
| 2 | L3₹86,100+₹17,650 (25.8%)Accepted-Finance | L3 | Accepted-Finance OTHER THAN LOWEST | |
| 3 | L2₹82,850+₹14,400 (21.0%)Rejected-Finance ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
Closing Date
16 Mar 2023, 6:00 pmClosed
GE DANAPUR CANTT
GE MES DANPUR CANTT
Soil investigation for Provn for construction of Modular operation Theatre , CSSD and ICU alongwith medical gas pipe line system of MH Danapur Cantt
2023_MES_582732_1
3049/JW/22-23/05/E3
Limited
Job Works
Works
30 days
DANAPUR CANTT
PLEASE REFVER IN TENDER DOCUMENTS
2 documents required · 2 mandatory
₹0
Exempted
22 Mar 2023
24 Feb 2023
18 Mar 2023
2 Mar 2023
16 Mar 2023
2 Mar 2023
Amount
Mobilisation of Mechanical drilling equipment / rig and shifting of entire arrange ment from one bore to another bore hole location and setting of boring/drilling rig as required/directed by Engineer-in-charge
Boring 150 mm dia bore hole, 10 mtr depth for BUILDING WORK : (A) Boring 150mm dia bore hole to 10 mtr through the following type of strata for building Note: Depth of bore holes may be taken 12m or N value reaches 50, whichever is earlier in any type of soil/soft disintegrated rock/hard rock for isolated /combined / raft foundation. To ensure that boulders or layers of cementeous soil is not mistaken for bed rock, core drilling to be done to a depth of atleast 3.0m in bed rock in areas where boulders are found & collection/ preparation of rock samples and determination of bulk density, water absorption and compressive strength is done. However the maximum depth of bore hole is 10m in any case.
(i) Any type of soil
(ii) Hard Rock
(A) Collection of undisturbed soil sample at 1.5m intervals or at any change in strata in 150mm bore thin walled tube including waxing, sealing, packing and transporting to the lab. B) Carrying out Standard Penetration test(SPT) including collection of disturbed soil samples in bore holes at every 1.5m depth or any change in strata and submit the report with all requisite data. (C) Conducting necessary tests as per relevant IS codes :-1892/NBC 2005/SP36 on all collected samples which include the determination of:-(a) Atterberg limits- Liquid limit, Plastic limit , Shrinkage limit(b) Wet and dry density, degree of saturation of soil.(c) Unit weight(Bulk density), Natural Moisture content, Plasticity index, Specific gravity (d) Grain size analysis, Identification and classification of soil, Soil particle size distribution using sieve/hydrometer analysis(e) Shear parameter (C-Phi Analysis), Tri-axial shear test and C-Phi determination.(f) Consolidation test and permeability test(g) Specific gravity test for sand/rock (h) Crushing strength, Degree of weathering(CR value) and RQD of rock samples(j) Permeability test(k) Chemical analysis of ground water sample (min 02samples) (water to be obtained from the bottom of bore hole) (l) Free swelling Index and Swelling pressure if expansive soil encountered.(m) Depth of water table below Ground level (maximum and minimum)(n) Presence of loose soil if any and its depth(o) If weak soil with lesser N value as specified in Table-I of IS 1893(Part-I):2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified.(p) Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation.(q) Recommendation for filling under floors and filling under protection including plinth protection.
Boring 150 mm dia bore hole, 06 mtr depth for BOUNDARY WALL : (A) Boring 150mm dia bore hole to 06 mtr through the following type of strata for baffle range (i) Any type of soil (B) Collection of undisturbed soil sample at 1.5m intervals or at any change in strata in 150mm bore thin walled tube including waxing, sealing, packing and transporting to the lab. (C) Carrying out Standard Penetration test(SPT) including collection of disturbed soil samples in bore holes at every 1.5m depth or any change in strata and submit the report with all requisite data. (D) Conducting necessary tests as per relevant IS codes :-1892/NBC 2005/SP36 on all collected samples which include the determination of:- (a) Atterberg limits- Liquid limit, Plastic limit , Shrinkage limit(b) Wet and dry density, degree of saturation of soil.(c) Unit weight(Bulk density), Natural Moisture content, Plasticity index, Specific gravity(d) Grain size analysis, Identification and classification of soil, Soil particle size distribution using sieve/hydrometer analysis(e) Shear parameter (C-Phi Analysis), Tri-axial shear test and C-Phi determination.(f) Consolidation test and permeability test(g) Specific gravity test for sand/rock(h) Crushing strength, Degree of weathering(CR value) and RQD of rock samples(j) Permeability test(k) Chemical analysis of ground water sample (min 02samples) (water to be obtained from the bottom of bore hole)(l) Free swelling Index and Swelling pressure if expansive soil encountered.(m) Depth of water table below Ground level (maximum and minimum)(n) Presence of loose soil if any and its depth(o) If weak soil with lesser N value as specified in Table-I of IS 1893(Part-I):2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified.(p) Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation.(q) Recommendation for filling under floors and filling under protection including plinth protection.
Submission of report in four sets giving site plan showing the test points, sub soil profile, results of field investigations, laboratory test results, calculation of SBC, Comprehensive type of foundation.
RAJ AND SONS
Sunder Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .