| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.0 L+₹75,170 (2.13%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.5 L+₹1.2 L (3.51%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.3 L+₹5.1 L (14.4%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.2 L+₹6.0 L (17.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
5 Nov 2022, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-69/2022-23 SPECIAL REPAIR / REPLACEMENT OF LT UG CABLE AND CERTAIN OTHER SANCTIONED WORKS AT AF STN PALAM UNDER GE( P) AF GURGAON.
2022_MES_555409_1
GE (P) AF/Gur-69/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹80,000
Yes
6 Dec 2022
30 Sept 2022
8 Nov 2022
30 Sept 2022
5 Nov 2022
21 Oct 2022
Amount
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
Supply and laying 100 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed.
Supply and laying 80 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed.
Supply and laying 50 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed.
Supply and laying 40 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed.
M & L for MS cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified.
Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Supply and fixing of steel tubular swaged poles type 410 SP-31 (9.00 mtr long) with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil for foundation of stay, laying of cable etc complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out hard/Dense soil for foundation of stay, laying of cable etc complete all as specified and as directed.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated material (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection complete all as specified and as directed
M&L for sand filling in trenches for cushioning of cable complete all as specified and directed. Note:- Compacted / punned sand shall be measured and considered for the purpose of payment.
Taking up old serviceable/unserviceable UG cable from trench for replacement , repair and re-laying or re-routing of size :- Earth work shall be measured and paid separately under appropriate items of Sch-'A')
10 Sqmm 2 Core to 35 Sqmm 3.5 Core
50 Sqmm 3.5 Core to 150 Sqmm 3.5 Core
185 Sqmm 3.5 Core to 400 Sqmm 3.5 Core
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade with cross sectional area of the following size :-
10 Sqmm 2 Core
16 Sqmm 2 Core
16 Sqmm 4 Core
25 Sqmm 3.5/4 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
150 Sqmm 3.5 Core
185 Sqmm 3.5 Core
240 Sqmm 3.5 Core
300 Sqmm 3.5 Core
400 Sqmm 3.5 Core
Re-laying/re-routing serviceable cable upto 35 Sqmm 3.5 core as obtained from item No. 18.1 here-in-before.
Re-laying/re-routing serviceable cable from 50 Sqmm 3.5 core to 150 Sqmm 3.5 Core as obtained from item No. 18.2 here-in-before.
Re-laying serviceable bricks as obtained from here-in-before.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Boring of holes under road, pavement, hard standing, drain etc by conventional method not exceeding 5 mtr in length for laying of cable for protection of pipe etc complete all as specified and as directed.
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth and 5 cm width complete all as specified and as directed.
Supply and fixing in repair LT UG cable aluminium lugs of following size including disconnection of U/S lugs from panel and making electrical connection complete all as specified and directed by Engr-in-Charge.
M& L for Indoor/outdoor cable end terminal joints (Resin cast type kits ) any type complete suitable for LT PVC insulated, sheathed UG cable for aluminium conductor cable and testing after joining of 4 core 35 to 50 Sqmm complete all as specified and as directed
All as per item No 28 here-in-before but 4 core 70 to 150 Sqmm size
All as per item No 28 here-in-before but 4 core 150 to 240 Sqmm size
All as per item No 28 here-in-before but 4 core 300 to 400 Sqmm size
M& L for straight through cable end terminal joints (Resin cast type kits) any type complete suitable for LT PVC & XLPE insulated, sheathed UG cable for aluminium conductor cable and testing after joining of 4 core 35 to 50 Sqmm complete all as specified and as directed.
All as per item No 32.0 here-in-before but 4 core 70 to 150 Sqmm size
All as per item No 32.0 here-in-before but 4 core 150 to 240 Sqmm size
All as per item No 32.0 here-in-before but 4 core 300 to 400 Sqmm size.
Machine pressed precast concrete interlocking paver block in repair of any shape and size confirming to IS 15658- 2006 of 80 mm thickness, M-35 grade, with grey cement and no pigment over 25mm thick sand cushioning complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm, 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion .
Supply & Installation of Smart Three Phase Meter with the following Specification: . AC Three Phase four Wire, Tamper Proof Static Meter of class 1.0, 240 v, 50Hz, 10A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display billing data genration facility anti- tamper features, Microprocessor and LED/LCD based circuitry. . Meter Should support the following data 30min instantaneous dada for voltage current, power, cumulative energy, cumulative apparent energy and frequency, 30 load survay data for energy, monthly billing survay for Cumulative Energy and Max Demand . Meter should have connect /disconnect functionality operable from billing software MAKE: Secure, L&T, Schineder
Supply and Installation of IP-67 protection data concentrator units (DCU)compatible for remote automatic metering Ifrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Enternet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network. Make: Secure, L&T, Schneider, CyanConnode
Supply and Configuration of the Web based software with following modules: (i) Meter data management Module. The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters -Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current,voltage, Power Factor and Feequency (b) Monthly billing survay data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module. The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billinge determinant and make energy data / billing data available to admin and end users. The billing module would includes functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.
(iii) Occupation and Vacation Module The system would support occupation /vacation and billing reports.the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated websiite for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to application. The MES staff would also have the access of the key information on an android mobiles app (for admin use) (v) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy /billing data. There would be android and iOS mobile apps for the user to moitor its own data and balance on regular basis.
(vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculation of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export The system would support export of metering and billing data in excel formet.
Supply and fix ceiling fan complete with electronic type regulator and accessories 20 volt having 3 blade of 1400 mm sweep, metalic finish complete all as directed.
Note:- The amount of Rs 2,42,147/- against Schedule of Credit on Page No 136 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S Anand Enterprises
Sumit Enterprises
H.B. Traders
S.R. Constructions
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .