| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹28.6 L+₹2.7 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.3 L+₹3.4 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹30.1 L+₹4.2 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Repair/Maint of Roof, Roof sheet, tiles and certain B/R works at Mil Stn Beas and Jandiala Guru under GE Kaprthala.
2024_MES_683656_1
GE KPT- /2024-25
Open Tender
Civil Works
Item Rate
180 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹70,000
Yes
1 Feb 2025
13 Nov 2024
18 Dec 2024
13 Nov 2024
11 Dec 2024
27 Nov 2024
Amount
Dismantling Asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings, complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of colour as approved having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Dismantling of wall paneling and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed by Engr-in-Charge.
Material and labour for ceiling using 9mm thick gypsum based ceiling tiles with weather resistance face on back side and vinyl finish including framework on the front fixed in 24mm GI Armstrong frame work of grid 600x600 mm size, the members of snap grid frame work of GI/Steel section of 24mm wide with T-flanges, channels etc of white colour having rotary stiching on all members, i.e main runner, 1200x600mm cross tee galvanised with minimum thickness of 120 gms per/sqm passed through 500 hrs test and hanging the same with existing roof members such as rafters, purlins or other wooden members particularly provided for hanging purpose using 8mm dia mild steel bar of required length fixed with nut bolt of 50mm long and 10mm dia of neck with washer flat iron 50x6mm thick clamps etc to steel members, complete all as specified and directed by Engineer-In-Charge.
Supply and fix 6mm thick PVC hollow wall paneling plain/coloured/printed fixed with screws to wall and corner, edges of panels be sealed with appropriate arrangement, colour and pattern as approved by GE, complete all as specified and directed by Engineer-In-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge.
Material and labour for rendering 15mm thick cement plaster in cement mortar (1:6) on any of brick work or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof exterior emulsion paints over and including a coat of primer, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of birla putty 1mm thick preparatory to distempering complete all as specified and directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames), complete all as specified and directed by Engr-in-Charge.
S&F powder coated anodised aluminium frame (thickness of powder coating not less than 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply and fix aluminium door with chowkhat of section 80mm x 40mm of wall thickness 1.58mm and bottom rail 160 x 40mm of wall tick ness 1.58mm including glazing with 5.5mm thick sheet glass including fittings such as aluminium tower bolt-2 No, handle-2 Nos, glazing pins, clips, beading and hydraulic door closure regulated designated 3 universal type complete all as specified and directed by Engineer-in-Charge. The shutter frame shall be tied at top (internally) with screw of round bar 10mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium window with chowkat of 89x32mm with wall thickness 2.75mm (weight 1.81 kg/RM) including double shutter of section 50 x 35 with wall thickness 1.5mm including double shutter (glazed and gauzed shutter) including 5.5 mm thick glass tinted, wire cloth 0.45 mm nominal dia of wire cloth and average width of aperture 1.25mm including aluminium grills, fitting such as aluminium tower bolt and handles complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engineer-in-Charge.
Supply only 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick frosted sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including hacking out old broken glass complete all as specified and directed by Engineer-in-Charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with Overall length of cover plate 140mm, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed complete all as specified and directed by Engr-in-charge.
S&F Aluminium anodised barrel tower bolts of extruded section of 200mm size etc, complete all as specified and directed by Engr-in-Charge.
M&L for aluminium mortice lock of 2 levers, vertical type, size 100 mm complete all as specified and directed by Engr-in-Charge.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wooden beads to steel windows/wooden doors complete all as specified and directed by Engr-in-Charge.
Dismantling mild steel work of any description, complete all as specified and directed by Engr-in-Charge.
S&F framed work such as grills, grating, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bar, barred iron boors, ladders, framed blausters, walk ways, railings, framework of water tanks and similar works confirming to Fe-290 Gde-E165 complete all as specified.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L for Light Shade Vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed (1:4) complete all as specified and directed by Engr-in-Charge.
M&L for Light Shade Vitrified ceramic tiles 10mm thick (square/rectangular) polished ,area of each tiles exceeding 0.42 sqm but not exc 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed (1:4) complete all as specified and directed by Engr-in-Charge.
M&L for Coloured Non-skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement match the shade of tile including 15mm thick screed bed (1:4) complete all as specified and directed by Engr-in-Charge.
M&L for Coloured Glazed Ceramic tiles in vertical surfaces 450x300x7/300x250x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour with 15mm thick cement screed bed (1:4) complete all as specified and directed by Eng-in-Charge.
M&L for Dholpur stone with hammer dressed facework (with maximum depression from a straight edge held against the dressed surface not exc 20mm), about 40mm high, 75mm deep in straight courses, laid and jointed in cement and stone dust mortar 1:3, recess pointed (10mm x 20mm) with an admixture of white cement and Dholpur stone dust 1:1 complete all as specified and directed by Engr-in-Charge.
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving not exceeding 15cm thickness (below or above ground level) etc complete all as specified and directed by Engineer-In-Charge.
M&L for 75mm thick PCC as in floor Type D2, 1:3:6 (40mm graded stone aggregate) complete all as specified and directed Engr-in-charge.
M&L for 25 mm thick Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed Engr-in-charge.
M&L for Machine pressed precast concrete interlocking paver block of M-35 grade any shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and no pigment complete all as specified and directed Engr-in-charge.
M&L for Machine pressed precast concrete interlocking paver block of M-35 grade any shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and with pigment complete all as specified and directed Engr-in-charge.
M&L for PCC 100mm thick type D-2, (1:3:6) using 40mm stone aggregate as in sub base of floors for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L for Screed bed or bedding layer of mortar 15 mm thick cement mortar (1:6) for laying floor finishing complete all as specified and directed by Engr-in-Charge.
M&L for chequered cement concrete tiles 20cmx20cmx 25mm thick, set jointed and pointed in neat cement slurry in floors with pigment complete all as specified and directed by Engr-in-Charge.
Material & Labour for PCC type B-0 (1:2:4) (using 12.5mm graded crushed stone aggregate) as in parapets walls, benching, as in roof, kerbs, rounded or chamfered edges coping and filling at junction of brickwork and the like including weathering, slightly rounded or chamfered angles and throating as directed complete including use of forwork (straight or curved) complete all as specified and directed by Engr-in-Charge.
Uprooting of tree roots from walls/roof of any girth at any height/location, of any depth by dismantling brick work/PCC by treating it with Ferro herbicide chemical agent of affected area making good the damaged portion as existing by PCC 1:2:4 type B-0 and finished with 15mm thick plaster in 1:4 all as specified and directed by Engr-in-Charge.
Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed by Engr-in-Charge.
Demolition of mud in roof any thickness incl plastering & leeping removed complete all as specified and directed by Engr-in-Charge.
M&L for Screed bed or bedding layer of mortar 15 mm thick as cement mortar 1:4 with WPC for laying floor finishes complete all as specified and directed by Engineer-In-Charge. Note :- Supply only of water proofing compound shall be measured and paid for separately under revelant items of this schedule.
Supply only integral water proofing compound (W.P.C) ISI marked complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multi polymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed by Engr-in-Charge.
M&L for PCC padding 1:2:4, type B-1 (using 20mm graded stone aggregate) of average thickness 75mm to be provided in Slope complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick Brick tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 with Jointing & Pointing in cement mortar (1:3) mixed with 5% of crude oil by wt of cement complete all as specified and directed by Engr-in-Charge.
All as per item no 49 above but except brick tiles complete all as specified and directed by Engr-in-Charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting exceeding 10cm girth but not exceeding 20cm girth complete all as specified and directed by Engr-in-Charge.
Taking down rain water pipes (any size and pattern), including all fittings, heads, shoes bends, swan necks etc removal form site (measured overall as fixed along the centre line or fittings and accessories) complete all as specified and as directed by Engr-in-Charge.
S&F PVC rain water pipes (SWR) 110mm dia (single socketed, in any length with rubber joints, fixed to walls with flat iron clamps complete all as specified and as directed by Engr-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) bend complete all as specified and directed by Engr-in-Charge.
Taking up or down, steel tubing 15mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 15mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall/making concealed including cutting through wall and making good, ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Taking up or down, steel tubing 20mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 20mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall/making concealed including cutting through wall and making good, ceiling or laid in floors, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix in repair 15mm bore pillar taps, cast copper alloy with capstan heads chromium plated, fancy type, screwed down high pressure with or without lettered Hot or Cold with long screwed shank and fly nuts, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix in repair 15mm bore long body bib tap with wall flange, cast copper alloy, chromium plated and screwed to iron pipes or union fittings complete all as specified and as directed by Engineer-in-Charge.
S&F in repair fancy type chromium plated stop valves, cast (angle cock) copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for bore of size 15mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs 15mm bore PVC connection and 450mm long with two Nos of brass check nuts and washers complete all as specified and directed by the Engineer-in-Charge.
Supply and fix in repairs shower rose of chromium plated with shower arm 195mm long with bend of 45 degree 15mm dia complete all as specified and as directed by Engineer-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) and cleaning and removing all scales and dust from PVC water tank manually and cleaning, scraping inner surfaces of tank by means of brush and then washing with clear water and cleaning of mouths of circulating pipes of capacity of tank exceeding 500 litre but not exceeding1000 litre including writing date of cleaned outer body of the tank with 100mm high by synthetic enamel paint (white/black colour) and reconnecting and refixing in position complete all as specified and directed by Engr-in-Charge.
S&F brass chromium tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous China Wash Basin with full pedestal, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc complete all as specified and directed including 15 mm dia Pillar taps, cast copper alloy with capstan heads Chromium Plated, screwed down high pressure, with or without lettered with long screwed shanks and fly-nuts, screwed for iron pipe but fancy type and fixed etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash down water closet, "Orissa pattern", size, 580x440mm white, with integral foot rest (excluding flushing cistern and flush pipe) but including provision of cement concrete bedding complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devices with recessed bottom, jet spray, etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china Urinal, Half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engr-in-Charge.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radous built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
S & F in repair Vitreous china premium/1st quality wash down water closet floor mounting EWC (One piece) P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, anti syphonage pipe, etc, with flush pipe PVC 32mm dia and including plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc, and including all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, including 100mm dia cast iron sanitary connections short connections pipe of length upto 600mm and Cutting holes in or through walls, packing with PCC 1 : 2 :4 complete and taking down existing of any description/size complete all as specified and as directed by Engr-in-Charge.
G M BUILDERS 36 (BID ID -3178207)
COSMO BUILDERS (BID ID -3186447)
ESS KAY BUILDER (BID ID -3180236)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .