GumBoot TechnicalSpecificationProduct:ElectricalInsulatingFiremanBootSize range Euro: 36 – 50 UK:3½-14½US:4½-15½ Typeof construction VulcanizedRubberUpperandSole Recommendation Structuralfirefighting,Generalfirerescue,BushfirefightingEuropeanStandardCEApprovedsuitableforfirerescue,firesuppression, property conservation & etc. HighElectricalResistanceOutsole,HeatInsulation ColdInsulation SlipResistanceonceramictilewithSodiumLaurylSulphateFuel Oil Resistant Outsole Heel Energy AbsorptionNailPenetrationResistanceToeProtection Resistant to hot contactToeprotectionCompressionresistanceNailpenetrationresistance 18kVElectricShockResistanceprotection LiningMaterial Extracomfortwithwovencottoncanvas Upperconstruction FlameretardantupperwithheatinsulationWaterproofReinforcedrubber Highvisibilitywithblackandyellowcontrast Sole/Heel Flameretardantrubberoutsole Fueloilresistantsolesuitableforinimicalenvironment SlipresistantvulcanizedrubberoutsoleExcellentabrasionresistantforextradurability HeelenergyabsorptiondesigntominimizeheelimpactCatered to enter high temperature Coldinsulationsoleconstruction SteelToeCap Epoxycoatedtoecapsforanti-corrosionMeetsimpactandcompressiontests Metaltoecapprovidesreliableprotectionincold&hotenvironmentsSteelMidsole Non-corrosive stainless steelWithstandspin& sharpobjectsChemicalResistance Sole&Upper–Resistanttowardsstrongacidsandalkali Finishing Lacquercoatingforweatherprotection
Helmate New, modern design and excellent protection properties. Optimalrelationshipbetweenprotectionandcomfortwithabroadspectrumofoptional upgrades. Structural fi refi ghting has never been safer. PERFORMANCE Extremetemperatureresistance (upto1,000°Cina10secondflashoverfl ames) Long-termtemperatureresistance(radiantheattest14kW/m2) HighresistancetomechanicalimpactsLow-temperatureclassification–30°CSAFETY Electricalinsulationcapacityheadprotection(includingneckandface)Interior shock absorber Reflectiveelementsforbettervisibilityinlow-lightconditions Neckprotector(availableinaluminisedfibre,Nomex,genuineleatheror wool for Holland style) 3pointchinstrap(testedtopreventskinirritation,fireretardantaramidtape) Chemical resistance COMFORT Lightweight Integratedadjustmentsystem Oneshellsizeforheadsizesfrom52to64cmWiderangeofaccessoriesand high level of personalisation HIGHTECHMATERIALS FlameretardantandhightemperatureresistantcompositeAnti-scratchand anti-fog coated integrated visorAnti-scratch and anti-fog coated integratedgoggle
Gloves ProductDescriptionFirefightingHandGlovesMake-Flaredefend Theuppermaterialisbeefhidesplitwithspecialtreatmentagainsthightemperature, penetration of water and oils. Another function of this leather treatment is resistance againstmechanicalrisks.Thenextlayeriscompositionthatincreasesresistanceagainst heat, abrasion TheglovesaretestedandcertifiedaccordingtoProtectionfor Firefighters.
SelfcontaincomprasairBASat A)The breathing apparatus should accept a range ofcompressed air cylinders( B) BA set shall contain air cylinder,back plate, facemask, lung demand regulator, pressurereducingvalve,pressuregauges,hoses,carryingcase,etc.(C)Theminimumdurationofuseofthesetshallnotbelessthan45minutes. ISOprovidesperformancespecificationsoftheselfcontainedair-breathingapparatus (SCBA)(notusingstoredoxygen)
Highledsearchlight55WMATERIAL ThebodyismadeofhighstrengthbutlightweightABCplastic,lendingitrigidity and toughness even in situations of rough handling. Whateverthe situation, you can laways bank on this solidly built, rain-proof FOSLED Search Light. LEDPOWER Featuring a high power 20W branded LED coupled with a big parabolicreflector,thisFOSrechargeabletorchoffersunmatchedluminosityofupto 1800 lumens with a focesed beam range visibility of up to 2 kms. BATTERYPOWER Powering the LED is a high-performance 2400 mAh, 7.4V Lithium-ionbattery which offers a battery backup of up to 5 hours. The packagecomeswith2batterychargers,anACWallChargingAdapterandaCarCharging Adapter, both with 9 V-1 Amp. Output. LIGHTMODES This heavy duty ewchargeable handheld torch comes with 2 lightbrightnessmodes,i.e.superstrongandstrong,whichcanbeusedasperyour lighting needs. UserApplication Heavydutyoutdoorultra-long-rangelighting applicationsas commercial searchoperationsforArmedForces,Industries,SecurityAgencies.
Multi Purpose branchConnection-21/2”,2”,11/4”Application-FIREFIGHTING Material-Aluminum,Alloy,StainlessSteelSize-63mm, 40mm, 50mm Flow-600LPM,800LPM,900LPM,1200LPM Pressure-7KG/CM2Hydrulic Test- 30KGWarranty- 5 YEARPressureBar-7KG/CM2 InletConnections-63MM,40MM, 50MM
MultiPurposeNozzel Flow 600Ipmto950LPM(110to210GPM) Inletsize:2½”(63mm)orasperRequirmentMeterial : Light weight hard coat anodized ALUMINIUMMaterial:StainlessSteel,BrassandAllTypeManufacturingSpary Angle : 120 Degree & 130 Degree Bumper:Rubberbumperwithteeth.Mode : Jet, spray and shut off Throw:Above35Mtr. FireHoseReelNozzle,PVCNozzlePlastic,FireHoseReelNozzleAllType.Specifications: DCGunType:OrdinaryDCGunNozzle Material : Nylon WorkPressure:12 BarSize:1 1/2”,2”,2 1/2” Flow:600,900,1200LPM Pressure:3to7BAR WarrantyGuarantee:5YEAR
LowerPressureApplicator Inlet– Pipe – Aluminum AlloyNozzle–BrassExtrudedRod Size–63mmMaleinstantaneousinletTest Pressure – 21 Bar WorkingPressure–7Bar DischargePattern–WaterCurtainPatternFlow Rate – 130 LPM @ 7 Bar DischargeRange–ThrowRange:7mMinimum Finish–NaturalSSFinishPolished
FireResistantDangries • 100% COTTON Fire Retardant Premium Fabric in 230 GSMadhering to ISO 11612:2015 A1 and A2. • 2 Front pockets with Quality Ring Buttons, 2 side pockets, 1tool pocket, 1 sleeve pocket and 2 back pockets. • For high visibility, 2 inch Fire retardant 3M reflective tapeshave been stitched on the shoulder, sleeves and on theknees. • Fire retardant YKK zippers front closure, ring buttons onsleeves for closure All thestress points have been bartacked. • The size is as per actual and gives a smart fit look however ifyou need a lose fit or if worn above work clothes then go 1sizebigger. FABRIC SPECIFICATION- Premium 100% Cotton per-shrunk FireretardantpremiumFabricin230GSMadheringtoISO11612:2015A1 andA2.
FireProximitySuit A. Coat/Jecket 1. GeneralDescription:Coatwithahighcentralzipclosure,coveredwithsuitable storm flap. The coat should have full-length sleeves and a standup collar with adjustable throat tab. 2. Standard:ThecoatmustmeettheNFPA1971:2007or 3. Construction a. Thecoatshouldhaveathree-layer construction: b. Outer Cloth: The outer shell fabric should be made from inherentlyflame resistant fiber with requisite blend of antistatic fibers. The colourof the outer shell be Dark Navy Shade . c. Moisture Barrier: Moisture Barrier shall be Fire resistant andbreathableinnature.Theconstructionshouldbemicroporousin nature likenonwovensubstrate/felt/PU/spunlacearamid–suitably laminated with PTFE / PU like membrane or treated with compound toensure that no water ingress from outside besides allowing perspirationand heat to escape from inside. d. ThermalBarrier:TheThermalBarriershould consistoftwo integratedorquiltedlayers.Theinnermostlayer facingthe MoistureBarrier shouldbe made from inherently flame resistant fibres in non wiven felt /corded lane construction. e. The should be detachable i.e., it should be able to be used as a singlelayered Coat or multiple layered Garment and should be detachable bybuttons from inside. f. Seams: All sewing to be done using para-aramid or equivalent stronginherently FR thread. The seams on the outer layer should be stitchedwith strong thread overlock. g. Pockets: Coat should be provided with 3 pockets as standard. 2 waistpockets on the lower fronts with flap closure and 1 patch pocket insidethecoat. h. Collar: The collar of the Coat should be designed so that the neckportion is doubley secured and covered by means of a throat tab, fittedwith fire retardant Velcro for secure fastening across the neck. A hangerloop, centrally placed on outer collar or inside section to be provided tofacilitatehanging. i. FrontClosure The coat should have a heavy-duty moulded zip beneath a full lengthcatch flap, closing with fire retardant Velcro. j. Sleevs & Cuffs: The sleeve should be designed to have an additionalgusset (all 3 layers) in the underarm or any other design innovation toallow the arms to move freely without raising the hem of the coat. Anaramid rib-knitted internal cuff to be provided for suitable wristprotection. k. Reflective Tape: The Coat should have a high quality reflective tapeprovided at the following places. - Single row 50 mm width, around hem / waist (including across frontflap) - Singlerow50mmwidth,aroundlowersleeves The tape should be premium quality and the quality should comply withthe length and test parameters stipulated in the corresponding NFPA /Enstandreds. l. Sizing: Size chart should be provided along-with the offer. The sizeshould be suitable for fitting on person of 5’10” & 5’ 8” height. m. Labels: A large clear label should be permanently attached (sealed)or stitched inside the lining of the fire suit. This label should give fulldetailsofcompliancetointernationalstandards,manufacturers’contactdetails, sizing, wash/care information, style and date of manufactureand traceability coding.
B. TROUSER 1. General Description: Trouser should have standard 36 inch &32 inch waist size and adjustable crossover braces, with theknees suitably padded and reinforced with an extra layer ofouter cloth. The waistof the Trousershould be elasticized atboth sides to provide a comfortable flexible fit. 2. Standard: The fire Trouser must meet the NFPA 1971 : 2007or their latest applicable version. The Suit should bear UL marking(for NFPA certified suit)with supporting certification. 3. Shape – Construction: Thetrousers should fit on the naturalwaistline (36 inch), ankle length and constructed withfollowing 3 layers:- (1) Outer Cloth: The outer shell fabric should be made frominherently flame resistant para aramid fibre material withrequisite blend of antistatic fibre. The colour of the outershell fabric shall be Dark Navy shade. (2) Moisture Barrier: Moisture Barrier shall be Fire resistant andbreathable in Nature. The Construction should be microporous in nature like non woven substrate/ felt / PU / spunlace aramid – suitably laminated with PTFE / PU likemembrane or treated with compound to ensure no wateringress from outside besides allowing perspiration and heatto escape from inside. (3) ThermalBarrier:TheThermalBarriershouldconsistoftwo integratedorquiltedlayers.Theinnermostlayerfacingthe Moisture Barrier should be made from inherently flameresistant fibers in non woven felt / corded laneconstructiong. The Trouser should be detachable i.e., itshould be able to be used as a single lovored coat multiplelovoredGormentandshouldbedetachablebybuttonefrom. 4. Seams Allsewing tobedoneusing para-aramidorequivalentstrong inherently FR thread. The seams on the outer layershould be stitched with strong thread overlock, 5. Knee Construction The knee should have an extra layer ofouter cloth as reinforcement or alternately an aramidenforcement. The knee region should be shaped or designedsuitably for comfprt and flexibility. 6. Pockets The Trouser should have I internal patch pocketinside the right or left hip. 7. Reflective Tape: The Trouser should have single row of 50mm wide reflective tape around lower leg. The tape shouldbe premium quality and should comply with test parametersstipulated in the corresponding NFPA/EN standards. 8. Sizing size chart should be provided alongwith the offer. Thesizeshouldbesuitableforfittingonpersonof5’-10”height&36 inch waist. m. Labels A large clear lable should be permanently attached( sealed) or stitched to the inside pocket/ section of theTrouser. This label should give full details of compliance tointernational standards, manufacturer’s contact details,sizing, wash/care information, style and date of manufactureand traceability coding.
C.ANTIFIRE HOODS STANDARDS:CertifiedtoNFPA1971FEATURES: The Hood should be offwhitecolour. ThefaceopeningshouldbeFitandFlat The NeckProtectorshouldbe fit andproperlycoveringtheshoulders. The Hood should be double layeredhaving each layer of the Fabric ofabout230GSM,insetcollarandfaceopening with elastic.
CHEMICALRETARDANTSUITS
FOAMMAKINGBRANCH: 1. FB5X 2. FB10X 3. FB20X 4. InlineIndusterFoam generater
ADAPTORS 1- Male to Male 2- Female to Female 3- Male to Female
DANGARIES Size M,L,XL, XXL
SHREE KARNI ENTERPRISES (BID ID -3185844)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .