Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.0 L+₹998.16 (0.07%)Rejected-AOC NOT FOUND | L2 | Rejected-AOC L2 | |
| 3 | L3₹18.1 L+₹3.1 L (20.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹19.7 L+₹4.7 L (31.7%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
28 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad
PROVISION OF STAND BY POWER SUPPLY TO AFPMU AND PW PECHORA AT AF STN TUGHLAKABAD UNDER GE (AF) TUGHLAKABAD
2021_MES_409057_1
CA NO. CWE/TKD/TOKEN-48/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Tughlakabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Tughlakabad
₹33,000
Yes
12 Feb 2021
2 Jan 2021
30 Jan 2021
2 Jan 2021
28 Jan 2021
16 Jan 2021
60 days
Amount
Supply, installation, testing and commissioning of 40 KVA with consideration of derating factor, Diesel engine driven generating set with acoustic enclosure suitable for outdoor installation complying to CPCB norms and with a proper ventilation using axial flow fan fitted in the acoustic cabinet complete with safety control and metering equipments mounted on common base frame on new PCC foundation all as recommended by the manufacturer and comprising the following :-
(j) ACOUSTIC ENCLOSURE : Floor mounted totally enclosed acoustic enclosure of suitable size as per CPCB norms duly epoxy painted, installed asPCC 1:2:4, type B-2, using 40mm graded sone aggregate platform 300mm above GL according to size of generator. It should be made out of min 2mm thick CRCA sheet gasket of door should be of high quality one door shall have glass window for control panel. Sound level of acoustic enclosure shall not more than 75 dba measured 1.00m away from DG set canopy panel and doors shall have inside of fire retardant foam conforming to IS-81283/BS-4735. Lockable fuel filling arrangement to be provided externally to the canopy. Note : The engine of DG set suitable be derated to suit the climate condition of so as to give desired output including 10% over load for continuous one hour operation. Make : Kirloskar / Cummins/ KOEL GREEN (E) OTHER FITTINGS. (a) Battery charger. Trickle Battery charger for one battery consisting of electric circuit consisting of triodes, rectifiers, capacitors, transformer, Ampmeter, indicator and Off/ON switch including power cable of size 1.5sqmm 3 core 230 volts with 3 pin top plug complete.make ELAK (c) The contractor shall supply two years maint spares for the above Gen Set :- (i) Fuel filter -06 Nos (ii) Lub oil filter -06 Nos (iii) Element air cleaner outer -03 Nos (iv) Element air cleaner inner -03Nos (v) V Belt - 02 Set
Supply, installation testing and commissioning of 62.5 KVA with consideration of derating factor, Diesel engine driven generating set with acoustic enclosure suitable for outdoor installation complying to CPCB norms and with a proper ventilation using axial flow fan fitted in the acoustic cabinet complete with safety control and metering equipments mounted on common base frame on new PCC foundation all as recommended by the manufacturer and comprising the following :-
(j) ACOUSTIC ENCLOSURE : Floor mounted totally enclosed acoustic enclosure of suitable size as per CPCB norms duly epoxy painted, installed as PCC 1:2:4, type B-2, using 40mm graded sone aggregate platform 300mm above GL according to size of generator. It should be made out of min 2mm thick CRCA sheet gasket of door should be of high quality one door shall have glass window for control panel. Sound level of acoustic enclosure shall not more than 75 dba measured 1.00m away from DG set canopy panel and doors shall have inside of fire retardant foam conforming to IS-81283/BS-4735. Lockable fuel filling arrangement to be provided externally to the canopy. Note : The engine of DG set suitable be derated to suit the climate condition of so as to give desired output including 10% over load for continuous one hour operation. Make : Kirloskar / Cummins/ KOEL GREEN (E) OTHER FITTINGS. (a) Battery charger. Trickle Battery charger for one battery consisting of electric circuit consisting of triodes, rectifiers, capacitors, transformer, Ampmeter, indicator and Off/ON switch including power cable of size 1.5sqmm 3 core 230 volts with 3 pin top plug complete.make ELAK (c) The contractor shall supply two years maint spares for the above Gen Set :- (i) Fuel filter -06 Nos (ii) Lub oil filter -06 Nos (iii) Element air cleaner outer -03 Nos (iv) Element air cleaner inner -03Nos (v) V Belt - 02 Set
Supply and laying in or fixing or passing through pipe cable FRLS, XLPE xable with aluminium conductor with heavy duty stranded,1100 volts of the following size. Note :-XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for PVC insulated cables. Make of cable : Havells/Polycab/Gloster
120 Sqmm, 3½ Core .
95 Sqmm, 3½ Core .
Taking out heavy duty MS duct cover 1.2 mx0.7 mx0.008mm or weighing upto 80 kg for laying of cable and refixing the duct cover after taking laying cable and refixing the same of any size and capacity in the duct complete all as specified and as directed.
Supply and fixing wall mounted off load changeover 100 Amp 415V AC, 50 Hz capacity including all connection as required at site complete all as specified and as directed.Make:- INDOASIAN/ HAVELLS/ HPL
Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for laying cable complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed Note : 18 cm thick only will be considered for payment purpose.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed.
M & L for excavation by trench less boaring technology for holes under road pavement, hardstanding using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 150 mm suitable for .4 Mpa working pressure complete all as specified and directed. Note: HDPE pipe and making good the disturbed surface shall be deemed to be included in unit rate quoted by contractor.
M & L for supply, installation and testing for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to but using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
shiv shanker enterprises
M/S S.K.Electricals
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .